• Title/Summary/Keyword: Collector System

Search Result 538, Processing Time 0.023 seconds

Analysis of Long-term Thermal Performance of Solar Thermal System Connected to District Heating System (지역난방 적용 태양열시스템의 장기 열성능 분석)

  • Baek, Nam-Choon;Shin, U-Cheul
    • Journal of the Korean Solar Energy Society
    • /
    • v.27 no.4
    • /
    • pp.167-173
    • /
    • 2007
  • This study analyzed by simulation using TRNSYS as well as by experiment on the solar district heating system installed for the first time for the district heating system in Bundang. Simulation analysis using TRNSYS focused on the thermal behavior and long-term thermal efficiency of solar system. Experiment carried out for the reliability of simulation system. This solar system where the circuits of two different collectors, flat plate and vacuum tube collector, are connected in series by a collector heat exchanger, and the collection characteristics of each circuit varies. Therefore, these differences must be considered for the system's control. This system uses variable flow rate control in order to obtain always setting temperature of hot water by solar system. Specifically, this is a system that heats returning district heating water (DHW) at approximately $60^{\circ}C$ using a solar collector without a storage tank, up to the setting temperature of approximately $85{\sim}95^{\circ}C$ To realize this, a flat plate collector and a vacuum tube collector are used as separate collector loops. The first heating is performed by a flat plate collector loop and the second by a vacuum tube collector loop. In a gross collector area basis, the mean system efficiency, for 4 years, of a flat plate collector is 33.4% and a vacuum tube collector is 41.2%. The yearly total collection energy is 2,342GJ and really collection energy per unit area ($m^2$) is 1.92GJ and 2.37GJ respectively for the flat plate vacuum tube collector. This result is very important on the share of each collector area in this type of solar district heating system.

Development of a Small Waste Appliance Collection System (소형 폐가전 수거 시스템 개발)

  • Cha, Hyun Chul
    • Journal of Korea Multimedia Society
    • /
    • v.24 no.12
    • /
    • pp.1653-1662
    • /
    • 2021
  • In this paper, we propose a small waste appliance collection system that can be used for efficient waste appliance collection, and implement an unmanned automatic small waste appliance collector system. First, we collected cases related to the collection of waste home appliances, compared and analyzed methods, and arranged the characteristics. We analyzed at the requirements for the collection and management system of waste appliances by dividing it into the aspect of the discharger and the recycling business company. The collection system consists of a client-server structure, which is a collector system and a collection management server. The unmanned automatic collector system is divided into a control unit and a machine/mechanical unit. We identified the functions that the collector system must perform and the hardware required to perform these functions. Based on this, the collector system was implemented as an embedded system. The hardware and software used in the implementation are described and the implementation results are described. The collection system developed in this paper will contribute to the development of urban mining industry by enabling the efficient collection of waste appliances.

Modeling Analysis for Thermal Performance of Solar Flat Plate Collector System Through a Year (평판형 태양열 집열기의 연중 열적 성능의 모델링 해석)

  • Kim, Gew Deok;Park, Bae Duck;Kim, Kyoung Hoon
    • Transactions of the Korean hydrogen and new energy society
    • /
    • v.25 no.5
    • /
    • pp.541-549
    • /
    • 2014
  • The monthly-average meteorological data, in particular, the monthly average daily terrestrial horizontal insolation are required for designing solar thermal energy systems. In this paper, the dynamic thermal performance of a flat plate solar collector system is numerically investigated through a year from the monthly average insolation data in Seoul. For a specified data set of solar collector system, the dynamic behaviors of total solar radiation on the tilted collector surfaces, heat loss from the collector system, useful energy and collector efficiency are analyzed from January to December by a mathematical simulation model. In addition, the monthly average daily total solar radiation, useful energy, and daily collector efficiencies through a year are estimated. The simulated results show that the average total radiation is highest in March and the useful energy is highest in October, while the total radiation and the collector efficiency are lowest in July.

The study on the comparison of the operation performance of different type of solar collectors (여러 가지 종류의 태양열 집열기 작동성능 비교 분석 연구)

  • Kim, Huidong;Baek, Namchoon;Lee, Jinkook;Joo, Moonchang
    • 한국신재생에너지학회:학술대회논문집
    • /
    • 2010.11a
    • /
    • pp.64.2-64.2
    • /
    • 2010
  • The objective of this study is to make a comparative study of the operation performance of different type of solar collectors. A flat-plate collector, a single-glazed evacuated collector and a double-glazed evacuated collector are used in this study. These 3 type of collectors are connected in series in the order of a flat-plate collector, a single-glazed evacuated collector and a double-glazed evacuated collector. This experimental facility is a kind of a solar system with a controller, a heat exchanger, a storage tank and a circulation pump. Each collector has a different collection area(flat-plate collector-$6.00m^2$ total area/$5.61m^2$ aperture area, double-glazed evacuated collector-$6.04m^2$ total area/$4.92m^2$ aperture area, single-glazed evacuated collector-$7.65m^2$ total area/$5.61m^2$ aperture area) and its performance characteristic respectively. The experiments have been demonstrated at around $70^{\circ}C$ operating temperature(flat-plate collector inlet temperature). The thermal collecting efficiencies of each collector are obtained under the different insolation and operation condition as a result.

  • PDF

Study on Thermal Dewatering of Sludge Using the Parabolic Through Collector(PTC) Solar Collector (PTC태양열 집열기를 이용한 슬러지 열탈수 연구)

  • Lee, Jung-Eun
    • Journal of the Korean Solar Energy Society
    • /
    • v.34 no.3
    • /
    • pp.49-56
    • /
    • 2014
  • A fiat-plate or vacuum tube solar collector have been mainly used for hot water supply of house because of some being difficult to get uniform energy density, so little applied into industrial field. This study is to apply the PTC(parabolic trough collector) solar collector into industrial field such as sludge dewatering system for energy reduction. The real scale system which composed of PTC Solar Collector and Thermal Dewatering (TDW) is established. PTC solar collector is designed to produce a hot water with $80^{\circ}C$ of temperature. And size of TDW is $630{\times}630mm$. Hot water produced from PTC solar collector is supplied into heating plate of TDW, and sludge like waterworks or wastewater is dewatered. PTC solar collector with $10m^2$ of area produce energy of average 5,618 kcal. As according to results from real scale performance, solar collector takes charge 94 % of the amount that TDW consume energy which is so large part if compare with boiler. It means that PTC solar collector is useful to apply industrial field under the condition of sufficient solar radiation. And it is analyzed that TDW by PTC solar collector has an economical validity.

Thermal Performance Analysis of Compound Parabolic Collector (CPC) System Employing Storage Tank Through a Year (축열조를 채용한 복합 포물형 태양열 집열기(CPC) 시스템의 연중 열적 성능 해석)

  • LIM, SOK-KYU;JUNG, YOUNG GUAN;KIM, KYOUNG HOON
    • Transactions of the Korean hydrogen and new energy society
    • /
    • v.30 no.4
    • /
    • pp.376-383
    • /
    • 2019
  • This paper presents of thermal performance analysis by using mathematical models for a compound parabolic collector (CPC) system employing heat storage tank. The thermal performance including insolation energy, heat loss from collector system, useful energy, collector efficiency, and temperature of storage tank were theoretically investigated through a year using monthly-average meteorological data at Seoul. The simulated results showed that the CPC systems are suitable for the applications of higher temperature than flat plate collector (FPC) systems.

The Analysis of Optimum Design Parameters for a Flat-Plate solar Collector Through Computer Simulation (컴퓨터 시물레이션 에 의한 太陽熱 集熱器 의 最適設計 에 관한 硏究)

  • 조수원;김종보
    • Transactions of the Korean Society of Mechanical Engineers
    • /
    • v.8 no.1
    • /
    • pp.1-9
    • /
    • 1984
  • In the utilization of solar energy most often a flat solar collector is used for solar heating, system. Since solar energy is absorbed through this solar collector, it is considered to be a most important part in the whole solar heating system. The purpose of the present investigation is to evaluate the influence of varying design parameters for thermal performances of flat-plate solar collector. By analysing these parameters, optimum design of solar collector would become possible. Specification of the existing solar collector are utilized in calculation as a starting point. Analysis is carried out numerically for "Unit Solar Collector" which is composed of fin and tube. Among design parameters. such parameters as mass flow rate per unit area, tube spacing and fin thickness are selected as variables in the computer simulation model. Results are presented for thermal performances of flat-plate solar collector for each important design parameters, so that predictions become possible through numerical analysis without performing experiments whenever it is required. required.

A Study on the Establishment of Optimum Design Conditions and Economic Evaluation for Rot Water Heating Solar Energy System (태양열(太陽熱) 급탕(給湯)시스템의 최적설계(最適設計) 조건(條件)의 설정(設定)과 경제성(經濟性) 평가(評價)에 관한 연구(硏究))

  • Lee, Young-Soo;Lee, Ki-Woo
    • Solar Energy
    • /
    • v.6 no.1
    • /
    • pp.47-59
    • /
    • 1986
  • This paper presents the establishment of optimum design conditions and economic evaluation for solar hot water system. The aim of this study is to present thermal performance of solar heating systems and to determine their performance as a function of collector size, storage capacity, tilting of collector and other factors. By analyzing its performance under the various conditions, optimum design of solar heating system can be obtained. System performance are obtained monthly and yearly basis respectively. At the same time the economics of various systems are evaluated. For the computer simulation Mokpo, Kangnung, Chupungnyong and Seoul are selected for particular installation places. As a result, the optimal design condition of solar heating system considering the following factors such as installation angle of collector, capacity of storage tank, collector size in each place can be obtained as follows; (1) Installation angle of collector Tilt = lattitude (2) Capacity of storage tank Solar domestic hot water system : $45\;1/m^2$ Multifamily solar domestic hot water system : $35\;1/m^2$ (3) Collector size i) Solar domestic hot water system Seoul & Chupyungyong area : $11.52\;m^2$ Mokpo area : $8.64\;m^2$ ii) Multifamily solar domestic hot water system Seoul, Chupyungyong & Mokpo area : $345.6\;m^2$ Kangnung area : $259.2\;m^2$

  • PDF

Optimum Design of Thermosyphon Solar Hot Water System (자연 대류형 태양열 온수기 최적 설계에 관한 연구)

  • Kang, Y.H.;Kwak, H.Y.;Lee, D.G.;Kang, M.C.
    • Solar Energy
    • /
    • v.18 no.4
    • /
    • pp.59-66
    • /
    • 1998
  • It was compared with experimental data to verify TRNSYS Model of the thermosyphon hot water system and the various simulations were conducted to optimize the component parameters of the system. To obtain consistent simulation results the system model, which could accurately describ the thermal storage tank temperature stratification and the friction head for mass flow rate, was used. The optimization of collector parameters(collector aspect ratio, riser numbers per header unit length), thermal storage tank parameters(ratio of tank length to tank diameter, heat exchanger type), system parameters(ratio of tank volume to collector area) was simulated by TRNSYS program. The simulation results indicate that the system performance is more effected by collector aspect ratio and the ratio of tank volume to collector area than the othor parameters.

  • PDF

An experimental study on the operating performance of facade installed natural circulation type solar thermal system (수직벽면형 무동력 태양열 시스템 작동성능에 관한 실험적 연구)

  • Baek, Nam-Choon;Lee, Wang-Je;Lee, Jin-Kook;Lee, Soon-Myung
    • Journal of the Korean Solar Energy Society
    • /
    • v.35 no.4
    • /
    • pp.1-7
    • /
    • 2015
  • The operation of the natural circulation type solar heating systems with facade integrated collector was analyzed by experiment. Two different types of flat plate solar collectors were used for these experiments. One was for the normal flat plate solar collector with the size of 1m*2m and the other was for the large size solar collector with $4m^2$(1m*4m). The experiments were carried out to investigate the effect of the series or parallel connection method on the performance of the collectors. As a result, the solar thermal system which is installed on the wall or facade would be applicable for the natural circulation type if the system design reflects various parameters, including collector connecting method(series or parallel), to provide enough vertical height between collector and storage tank, and to reduce pressure loss due to collector and piping network, etc. The natural circulation type of solar thermal system as proposed in this study can increase the system reliability by removing or minimizing the use of the components such as pump, controller, sensors which may cause serious troubles of the system for a long-time operation