• Title/Summary/Keyword: Collection Efficiency

Search Result 949, Processing Time 0.032 seconds

Characteristics of particulate matter collection efficiency and ozone emission rate of an electrostatic precipitator by thickness of high-voltage electrode and distance of collection plates (고전압 전극 두께와 집진판 간격에 따른 전기집진기의 미세먼지 집진효율 및 오존발생 특성)

  • Lee, Jae-In;Woo, Sang-Hee;Kim, Jong Bum;Lee, Seung-Bok;Bae, Gwi-Nam
    • Particle and aerosol research
    • /
    • v.14 no.4
    • /
    • pp.171-180
    • /
    • 2018
  • To optimize the shape of the electrostatic precipitator for the removal of particulate matter in subway environments, the wind-tunnel experiments were carried out to characterize collection efficiency and ozone emission rate. As a standardized parameter, power consumption divided by the square of flow velocity, was increased, the $PM_{10}$ collection efficiency increased. If the standardized parameter is higher than 1.0 due to high power consumption or low flow velocity, increase in thickness of electrodes from 1 to 2 mm, or increase in distance of collection plates from 5 to 10 cm did not change the $PM_{10}$ collection efficiency much. Increase in thickness of high-voltage electrodes, however, can cause decrease in $PM_{10}$ collection efficiency by 28% for low power consumption and high flow velocity. The ozone emission rate decreased as distance of collection plates became wider, because the ozone emission rate per unit channel was constant, and the number of collection channels decreased as the distance of collection plates increased. When the distance of collection plates was narrow, the ozone emission rate increased with the increase of the thickness of electrodes, but the difference was negligible when the distance of collection plates was wide. It was found that the electrostatic precipitator having a thin high-voltage electrodes and a narrow distance of collection plates is advantageous. However, to increase the thickness of high-voltage electrodes, or to increase the distance of collection plates is needed, it is necessary to increase the applied voltage or reduce the flow rate to compensate reduction of the collection efficiency.

A Study on Prediction of Collection Efficiency of Electrostatic Precipitator Using Eulerian Numerical Analysis (오일러리안 수치해석법을 이용한 전기집진기의 집진효율 예측에 관한 연구)

  • Park, Jeong-Ho;Chun, Chung-Hwan
    • Proceedings of the KSME Conference
    • /
    • 2001.06d
    • /
    • pp.618-623
    • /
    • 2001
  • The transport of charged particles in electrostatic precipitator is investigated by Eulerian numerical analysis. Collection efficiencies are calculated using various combinations of the assumptions about flow field, turbulent diffusivity and boundary condition at collecting electrode. The characteristics of calculated collection efficiencies are compared with the trends of published experimental results. It is found that the collection efficiency for the case using nonuniform turbulent flow field, nonuniform turbulent diffusivity and zero concentration boundary condition at collecting electrode is the most suitable for the prediction of collection efficiency of electrostatic precipitator.

  • PDF

An Experimental Study for Designing Electrostatic Precipitator: Focused on Collection Efficiency Variation per Area and corona Power

  • Kim, Jong-Ho;Cho, Yong-Kyun;Bong, Choon-Keun;Yun, Joong-Sup;Kim, Shin-Do
    • Journal of Korean Society for Atmospheric Environment
    • /
    • v.16 no.E2
    • /
    • pp.79-84
    • /
    • 2000
  • The Electrostatic Precipitator is one of the most favorable device of particulate control systems because of the relatively higher collection efficiency and easier operation/maintenance. However, it requires very high initial coat especially for discharging electrodes and collecting plates. In dealing with such problems, development of optimum design can be one of the solutions. In this study, a bench-scale electrostatic precipitator was operated in terms of collection area and corona power, and its performances were analyzed focusing on collection efficiency. A result of this study, a more advanced approach for designing cost-effective precipitator by promoting corona power at a minimized collection area was proposed.

  • PDF

Study on improvement of submicron particle collection performance in 2-stage parallel-plate electrostatic precipitators (2단 평행판 전기집진기의 서브마이크론입자 집진성능 개선 연구)

  • Yoo, K.H.;Oh, M.D.;Lee, J.S.
    • Korean Journal of Air-Conditioning and Refrigeration Engineering
    • /
    • v.9 no.3
    • /
    • pp.323-332
    • /
    • 1997
  • It was reported by some researchers that two-stage parallel-plate ESPs, commonly called electronic air cleaners, show decreasing behavior of collection efficiency as particle size decreases below about $0.03{\mu}m$. This phenomenon is attributed to partial particle charging characteristics, where some of incoming particles are not charged in the charging cell of 2-stage parallel-plate ESP. One way to improve the decreasing collection efficieny in that particle size range is to enforce particle charging quantity in the charging cell. In the present study, in order to do this a 2-wire series-type charging cell modified from a 1-wire normal-type one was suggested and investigated theoretically and experimentally concerning improvement of the collection efficiency. It was confirmed from the experimental and theoretical works that the collection efficiency was apparently improved.

  • PDF

Optimization analysis on collection efficiency of vacuum cleaner based on two-fluid and CFD-DEM model

  • Wang, Lian;Chu, Xihua
    • Advances in Computational Design
    • /
    • v.5 no.3
    • /
    • pp.261-276
    • /
    • 2020
  • The reasonable layout of vacuum cleaner can effectively improve the collection efficiency of iron filings generated in the process of steel production. Therefore, in this study, the CFD-DEM coupling model and two-fluid model are used to calculate the iron filings collection efficiency of vacuum cleaner with different inclination/cross-sectional area, pressure drop and inlet angle. The results are as follows: The CFD-DEM coupling method can truly reflect the motion mode of iron filings in pneumatic conveying. Considering the instability and the decline of the growth rate of iron filings collection efficiency caused by high pressure drop, the layout of 75° inclination is suggested, and the optimal pressure drop is 100Pa. The optimal simulation results based on two-fluid model show that when the inlet angle and pressure drop are in the range of 45°~65° and 70Pa~100Pa, larger mass flow rate of iron filings can be obtained. It is hoped that the simulation results can offer some suggestion to the layout of vacuum cleaner in the rolling mill.

Characteristics of Electrostatic Cyclone-Bag Filter with Upper Inlet (상부유입식 전기 Cyclone-Bag Filter의 특성)

  • 여석준
    • Journal of Korean Society for Atmospheric Environment
    • /
    • v.16 no.2
    • /
    • pp.179-190
    • /
    • 2000
  • The main object of this study was to investigate experimentally the characteristics of electrostatic cyclone-bag filter with upper tangential inlet in order to overcome the low collection efficiency for the submicron particle and high pressure drop which were main problems of general fabric bag filters. The experiment was carried out for the analysis of collection efficiency and pressure drop of electrostatic cyclone-bag filter comparing to those of fabric bag filter with various experimental parameters such as the inlet velocity(filtration velocity) and applied voltage etc. In the results the upper tangential inlet type showed higher collection efficiency for submicron particles below 2 ${\mu}{\textrm}{m}$ in diameter than that of center inlet and over 99.9% for overall collection efficiency. Pressure drop reduction ratios were shown as 40-50% for the applied voltage 0kV by centrifugal force and 70-90% for 20k V by the centrifuga and electrostatic force with the tangential inlet velocity (12-21m/s)

  • PDF

The Device Allocation Method for Energy Efficiency in Advanced Metering Infrastructures (첨단 검침 인프라에서 에너지 효율을 위한 기기 할당 방안)

  • Jung, Sungmin
    • Journal of Korea Society of Digital Industry and Information Management
    • /
    • v.16 no.1
    • /
    • pp.33-39
    • /
    • 2020
  • A smart grid is a next-generation power grid that can improve energy efficiency by applying information and communication technology to the general power grid. The smart grid makes it possible to exchange information about electricity production and consumption between electricity providers and consumers in real-time. Advanced metering infrastructure (AMI) is the core technology of the smart grid. The AMI provides two-way communication by installing a modem in an existing digital meter and typically include smart meters, data collection units, and meter data management systems. Because the AMI requires data collection units to control multiple smart meters, it is essential to ensure network availability under heavy network loads. If the load on the work done by the data collection unit is high, it is necessary to allocation new data collection units to ensure availability and improve energy efficiency. In this paper, we discuss the allocation scheme of data collection units for the energy efficiency of the AMI.

Performance of Automotive Cabin Air Filter for Passenger Cars (승용차용 Cabin Air Filter의 성능)

  • 박영옥;구철오;임정환;김홍룡;손재익
    • Journal of Korean Society for Atmospheric Environment
    • /
    • v.12 no.3
    • /
    • pp.279-287
    • /
    • 1996
  • Pressure drop and fractional collection efficiency of automotive cabin air filters were examined to obtain the basic data for the development of high performance domestic cabin air filters. Pressure drop of MA-V100 was higher than that of VF-V100, and it increased with the air flow rate. VF-V100 had longer time to rise the critical pressure drop than that MA-V100 had. Total collection efficiency of MA-V100 for initial and dust loaded conditions was higher than that of VF-V100. Also, fractional collection efficiency of MA-V100 for the fine particles was higher than that of VF-V100. Particla size distribution for the minimum collection efficiency ranged from 0.02 $\mu$m to 0.04 $\mu$m for MA-V100 and it ranged from 0.02 $\mu$m to 0.15 $\mu$m for VF-V100.

  • PDF

A Study on Collection Efficiency of Pilot Electrostatic Precipitator (연소장치를 이용한 소형 전기집진장치의 집진 효율에 관한 연구)

  • 한재균;최금찬
    • Journal of Korean Society for Atmospheric Environment
    • /
    • v.9 no.2
    • /
    • pp.125-131
    • /
    • 1993
  • Electrostatic Precipitator has been widely used to get high efficiency which is required for collection of fine particles. In order to provide collection efficiency and size distribution data for a pilot electrostatic precipitator, a pilot study has been conducted on fly ash from pulverized coal burning apparatus. The aims of this study are to investigate characteristics of electric charge, to measure collection efficiency varied with the applied voltage, to get an optimum current and current density. Optimum current density was obtained to 0.7mA/$cm^2$ at the average electric field strength 2.33kV/cm in this experiment. Maximum particle collection efficiency was indicated 99.21% at the applied voltage 7kV. Finally, particle size distribution is also compared with photographic results. Both coarse and fine particles at the range of 0.5$\sim$2$\mu$m and 3$\sim$10 SEM $\mu$m were clearly removed by increasing applied voltage.

  • PDF

Relationship between the Outer Vortex and the Collection Efficiency with respect to Temperatures in the Cyclone Dust Collector (사이클론 집진장치의 내부온도에 따른 외부 소용돌이와 집진효율의 관계)

  • Hyun, Daegeun;Chang, Hyuksang
    • Particle and aerosol research
    • /
    • v.11 no.2
    • /
    • pp.47-55
    • /
    • 2015
  • This study compares the results of collection efficiency of difference gas temperature in cyclone dust collector. The previous researcher's experiment results were used to confirm the reliability of CFD(Computational Fluid Dynamics) model. Based on this verified CFD model, we extended the analysis on the cyclone dust collectors. In CFD study, we used RNG k-epsilon model for analysis of turbulence flow, fluid is air, the velocity at inlet is 10 m/s, the temperature of air is $20^{\circ}C$, $100^{\circ}C$, $200^{\circ}C$, $300^{\circ}C$, $600^{\circ}C$ and $1000^{\circ}C$. As the temperature decreases, the average velocity of outer vortex and collection efficiency is increased, showed the highest collection efficiency at $20^{\circ}C$. It can be inferred smooth flow in cyclone dust collector is difficult because air viscosity increases as temperature increases. The power required at $1000^{\circ}C$ is almost 18 times greater than that of $20^{\circ}C$ to get the similar collection efficiency.