• 제목/요약/키워드: Collarless metal ceramic crown

검색결과 8건 처리시간 0.027초

도재전장주조관의 순측 치경부 변연 적합도에 관한 주사전자현미경적 연구 (FITNESS OF THE COLLARLESS METAL-CERAMIC RESTORATIONS AT LABIAL MARGINS: A SCANNING ELECTRON MICROSCOPE STUDY)

  • 김영한;이선형
    • 대한치과보철학회지
    • /
    • 제23권1호
    • /
    • pp.113-123
    • /
    • 1985
  • The purpose of this study was to evaluate the marginal fitness of collarless metal-ceramic crown formed with direct lift technique using wax compared with metal-ceramic crown with metal butt margin. Twenty crowns, ten were collarless metal-ceramic crowns and ten were metal-ceramic crowns with metal butt margins, were made and cemented on epoxy resin dies, and their marginal openings were measured on scanning electron microphotographic prints at x200 magnification. The results were as follows; 1. In the case of collarless metal-ceramic crowns, the mean marginal opeining was $43.78{\pm}17.67{\mu}m$, the mean maximum marginal opening was $52.81{\pm}19.81{\mu}m$, and the mean minimum marginal opening was $34.99{\pm}16.58{\mu}m$. 2. In the case of metal-ceramic crowns with metal butt margins, the mean marginal opening was $47.62{\pm}25.55{\mu}m$, the mean maximum marginal opening was $61.90{\pm}24.39{\mu}m$, and the mean minimum marginal opening was $34.86{\pm}24.92{\mu}m$. 3. There was no significant difference between two types of crowns at the 99% confidence level. 4. The marginal fitness of collarless metal-ceramic crown formed with direct lift technique using wax was clinically acceptable.

  • PDF

Collarless도재소부전장금관의 제작방법에 따른 치경부 변연적합도에 관한 실험적 연구 (AN EXPERIMENTAL STUDY ON THE CERVICAL MARGIN FITNESS IN THE COLLARLESS METAL CERAMIC CROWNS FORMED BY DIFFERENT TECHNIQUES)

  • 이재혁
    • 대한치과보철학회지
    • /
    • 제28권1호
    • /
    • pp.203-216
    • /
    • 1990
  • The purpose of this study was to evaluate the cervical margin fitness in the collarless metal ceramic crowns formed by different techniques. Specimens were divided as follows : the metal ceramic crowns with metal butt margin as group I, the collarless metal ceramic crowns formed with resin binder technique as group II, and the collarless metal ceramic crowns formed with shoulder powder mixed with phosphate-bonded investment liquids on a refractory die as group III. Each group was made of five specimens, and their marginal fitness on each epoxy die was evaluated under scanning electron microscope of x200 magnification at three measuring points : mesial, central, distal. The following results were obtained. 1. The metal ceramic crowns with metal butt margin exhibited significantly better marginal fitness than the collarless metal ceramic crowns. The marginal fitness in descending order was group I, III, II. 2. The collarless metal ceramic crown formed with resin binder technique had the worst marginal fitness & showed cervical color variation and dermacation between the corrected porcelain & the dentin porcelain. 3. The collarless metal ceramic crowns formed with shoulder powder mixed with phosphate-bonded investment liquids on a refractory die exhibited significantly better marginal fitness & sharper marginal configuration than the other collarless group.

  • PDF

금속코핑 설계에 따른 Collarless Metal Ceramic Crown의 파절강도에 관한 연구 (A STUDY ON FRACTURE STRENGTH OF COLLARLESS METAL CERAMIC CROWN WITH DIFFERENT METAL COPING DESIGN)

  • 윤종욱;양재호;장익태;이선형;정헌영
    • 대한치과보철학회지
    • /
    • 제37권4호
    • /
    • pp.454-464
    • /
    • 1999
  • The metal ceramic crown is currently the most popular complete veneer restoration in dentistry, but in many cases, the metal cervical collar at the facial margin is unesthetic and unacceptable. Facial porcelain margin has been used in place of it. But this dose not solve the problems, such as dark gingival discoloration and cervical opaque reflection of porcelain veneer. Recently, metal copings which were designed to terminate its labio-cervical end on the axial walls coronal to the shoulder have been clinically used to solve the esthetic problem of metal ceramic crown. But in this design, porcelain veneer of labio-cervical area which is not supported by metal may not be able to resist the stress during cementation and mastication. The purpose of this study was to evaluate fracture strength and fractured appearance of crowns according to different coping designs. A resin maxillary left central incisor analogue was prepared for a metal ceramic crown, and metal dies were made with duplication mold. Metal copings were made and assigned to one of four groups based on facial framework designs: group 1, coping with 0.5mm metal collar; group 2, metal extended to the shoulder; group 3, metal extended to 1mm coronal tn the shoulder: group 4, metal extended to 2mm coronal to the shoulder. Copings and crowns were adjusted to be same size and thickness, and cemented to metal dies with zinc phosphate cement by finger pressure. Fracture strength was measured with Instron Universal Testing Machine. Metal dies were anchored in Three-way-vice at 3mm below finish line and at $130^{\circ}$ inclined to the long axis of the crown. Load was directed lingually at 2mm below midincisal edge. Load value at initial crack and at catastrophic fracture was recorded. The results obtained were as follows : 1. Fracture strength values at initial crack were higher in groups 1, 2 than in groups 3, 4 but this difference was not statistically significant(P<0.05). 2. Conventional metal collared crown had greater catastrophic fracture strength than any other collarless crowns. 3. The greater the labial metal coping reduction, the lower the catastrophic fracture strength of crowns but when more than 1mm of labial metal reduction was done, the difference in strengths was not statistically significant(p<0.05). 4. The strongest collarless coping design was group 2.

  • PDF

내부금속관 형태에 따른 도재전장금관의 파절강도와 도재색조에 관한 연구 (A STUDY ON FRACTURE STRENGTH AND COLOR BY THE DESIGN OF METAL COPING IN CERAMO METAL CROWN)

  • 이명호;전영찬
    • 대한치과보철학회지
    • /
    • 제30권1호
    • /
    • pp.103-124
    • /
    • 1992
  • The purpose of this study was to investigate the effect on the fracture strength and color of ceramic by the design of the metal coping in ceramo metal crown. In this study, four types of ceramic crowns were made for fracture strength : standard ceramo metal crown, collariess ceramo metal crown, modified ceramo metal crown, and ceramic jacket crown. And three types of disk formed-specimens were made to compare the dentin shade owing to aluminous opaque powder and palladium alloy. Fracture strength was measured by universal testing machine(Instron Co. Ltd., U.S.A) and color was measured by color and color difference meter(Yasuda Seiki Seisakusho, Ltd., Japan). The results were as follows : 1. The fracture strength of ceramic was affected significantly by the design of metal coping in ceramo metal crown. The mean fracture strength(192.0 Kg) of standard ceramo metal crown was about 1.7 times higher than that(111.5 Kg) of collarless ceramo metal crown, and about 2.8 times higher than that(67.8 Kg) of ceramic jacket crown. 2. Modified ceramo metal crown that has metal band in the labio cervical had the lowest fracture strength. 3. Lightness, yellowness and redness of the dentin fired were decreased by the metal coping.

  • PDF

열가압성형도재의 사용이 금속도재관 치경부 변연적합도에 미치는 영향 (The effect of heat and press-on-metal technique on marginal fit of metal-ceramic crown)

  • 김지은;김세연;이청희
    • 대한치과보철학회지
    • /
    • 제52권2호
    • /
    • pp.90-96
    • /
    • 2014
  • 연구 목적: 이 연구의 목적은 열가압성형기법이 금속도재관의 치경부 변연적합도에 미치는 영향을 확인하는 것이다. 연구 재료 및 방법: 실험에 앞서, 4개의 금속 주모형을 형성하였다. 각 모형은 각각chamfer, heavy chamfer, shoulder with bevel, shoulder (collarless)변연을 형성하였다. 각 변연당 10개씩의 금관을 제작하여, 총 40개를 제작하였다. Coping 단계에서, 그리고 금속도재관 완성 단계에서 주모형과 금관 사이의 변연간극은 100배율의 광학현미경 관찰을 통하여 측정되었다. Data분석은 paired t-test along with one-way ANOVA와 Duncan multiple comparison test를 이용하여 이루어졌다. 결과: 변연간극의 평균과 표준편차를 분석한 결과, 금속 코핑과 그 후 완성된 금속도재관, 모든 경우에서 변연부 간격은 임상적 허용범위 안에 있었다. Chamfer 변연 실험군의 경우 Heavy chamfer 변연 실험군에 비하여 금속도재관 완성 후 변연부 간격의 유의한 증가가 있었다. 그리고Shoulder 변연 실험군에서 도재로 처리된 변연이 Chamfer와 Shoulder변연 실험군의 금속변연에 비하여 변연부 간격이 유의하게 작게 나타났다. 결론: 열가압성형기법을 통하여 제작한 금속도재수복물의 변연적합도는 전통적인 방법으로 제작한 금속도재수복물의 변연적합도와 유의한 차이점이 없었다. 제작과정의 효율성으로, 열가압성형기법은 임상에서의 효과적인 사용법으로 고려될 수 있다.

Alternate metal framework designs for the metal ceramic prosthesis to enhance the esthetics

  • Vernekar, Naina Vilas;Jagadish, Prithviraj Kallahalla;Diwakar, Dr Srinivasan;Nadgir, Ramesh;Krishnarao, Manjunatha Revankar
    • The Journal of Advanced Prosthodontics
    • /
    • 제3권3호
    • /
    • pp.113-118
    • /
    • 2011
  • PURPOSE. The objective of the present study was to evaluate the effect of five different metal framework designs on the fracture resistance of the metal-ceramic restorations. MATERIALS AND METHODS. For the purpose of this study, the central incisor tooth was prepared, and the metal analogue of it and a master die were fabricated. The counter die with the 0.5 mm clearance was used for fabricating the wax patterns for the metal copings. The metal copings with five different metal framework designs were designed from Group 1 to 5. Group 1 with the metal collar, Group 2, 3, 4 and 5 with 0 mm, 0.5 mm, 1 mm and 1.5 mm cervical metal reduction respectively were fabricated. Total of fifty metal ceramic crown samples were fabricated. The fracture resistance was evaluated with the Universal Testing Machine (Instron model No 1011, UK). The basic data was subjected to statistical analysis by ANOVA and Student's t-test. RESULTS. Results revealed that the fracture resistance ranged from 651.2 to 993.6 N/$m^2$. Group 1 showed the maximum and Group 5 showed the least value. CONCLUSION. The maximum load required to fracture the test specimens even in the groups without the metal collar was found to be exceeding the occlusal forces. Therefore, the metal frameworks with 0.5 mm and 1 mm short of the finish line are recommended for anterior metal ceramic restoration having adequate fracture resistance.