• Title/Summary/Keyword: Collapse time

Search Result 588, Processing Time 0.021 seconds

A System Simulation for Investigation of IT and Society Co-evolution Dynamics and Its Policy Implications (시스템 시뮬레이션을 통한 기술과 사회 공진화의 동태성 고찰)

  • Kim, Sang-Wook;Jung, Jae-Lim
    • Korean System Dynamics Review
    • /
    • v.9 no.1
    • /
    • pp.171-197
    • /
    • 2008
  • By applying Systems Simulation technique, this paper aims to investigates the dynamics underlying the coevolution of IT(information technology) and the society. Particularly, a series of basic questions are explored to answer by developing a simulation model for the mechanisms underlying the 'hype curve' ever occurring in the course of technology diffusion into society: First, why hype curve appears in the process of technology and society coevolution. Second, how to enhance the tapering level at the final stage of coevolution. Third, what are the key policy leverages and when is the right time for the policy intervention. As now, inflated expectations regarding ubiquitous information technology (u-IT) are growing very fast and higher than those for the previous technologies, which would result in overshoot followed by collapse of visibility and thus incur tremendous amount of social costs. In this regard implications drawn from this study perhaps give some insights not necessarily to the academics but also to the practitioners and policy makers facing the advent of u-IT as a new emerging horizon of information society.

  • PDF

Fire Resistance Behaviour of High Strength Concrete Members with Vapor Pressure and Creep Models (증기압 및 크리프 모델을 사용한 고강도콘크리트 부재의 내화성능평가)

  • Lee, Tae-Gyu
    • Fire Science and Engineering
    • /
    • v.24 no.4
    • /
    • pp.33-40
    • /
    • 2010
  • A numerical model considering the vapor pressure and the creep models, in the form of a analytical program, for tracing the behavior of high strength concrete (HSC) members exposed to fire is presented. The two stages, i.e., spalling procedure and fire resistance time, associated with the thermal, moisture flow, creep and structural analysis, for the prediction of fire resistance behavior are explained. The use of the analytical program for tracing the response of HSC member from the initial pre-loading stage to collapse, due to fire, is demonstrated. The validity of the numerical model used in this program is established by comparing the predictions from this program with results from others fire resistance tests. The analytical program can be used to predict the fire resistance of HSC members for any value of the significant parameters, such as load, sectional dimensions, member length, and concrete strength.

Structural Behavior Characteristics Analysis for Main Sanctuary Mandapa of Hong Nang Sida Temple in Laos (라오스 홍낭시다 주신전 만다파의 구조적 거동특성 분석)

  • Kim, Ho-Soo;Hong, Souk-Il;Kim, So-Yeon;Kim, Jin-Wan;Yoo, Jun
    • Journal of Korean Association for Spatial Structures
    • /
    • v.17 no.3
    • /
    • pp.35-43
    • /
    • 2017
  • The Hong Nang Sida temple is a cultural heritage that must be preserved due to the historical and cultural values that are highly evaluated in the world. The main sanctuary of Hong Nang Sida temple, presumed to have been built in 11th to 12th centuries, has been exposed in the open air for a long time after the collapse. Therefore, it is necessary to reconstruct the original shape of the Hong Nang Sida temple to reflect the original shape. To do this, it is necessary to examine the overall structure according to the restoration shape. For this purpose, this study analyzes the construction and configuration types for main sanctuary Mandapa of Hong Nang Sida temple, and conducts structural modeling according to actual and restoration plans. The structural and behavioral characteristics are analyzed by comparing stress and displacement values by measurement locations. In addition, we will examine the vertical load distribution by the layers of each wall and cobel arch of the Mandapa using the load distribution method.

The Structural Design of Tianjin Goldin Finance 117 Tower

  • Liu, Peng;Ho, Goman;Lee, Alexis;Yin, Chao;Lee, Kevin;Liu, Guang-lei;Huang, Xiao-yun
    • International Journal of High-Rise Buildings
    • /
    • v.1 no.4
    • /
    • pp.271-281
    • /
    • 2012
  • Tianjin Goldin Finance 117 tower has an architectural height of 597 m, total of 117 stories, and the coronation of having the highest structural roof of all the buildings under construction in China. Structural height-width ratio is approximately 9.5, exceeding the existing regulation code significantly. In order to satisfy earthquake and wind-resisting requirements, a structure consisting of a perimeter frame composed of mega composite columns, mega braces and transfer trusses and reinforced concrete core containing composite steel plate wall is adopted. Complemented by some of the new requirements from the latest Chinese building seismic design codes, design of the super high-rise building in high-intensity seismic area exhibits a number of new features and solutions to professional requirements in response spectrum selection, overall stiffness control, material and component type selection, seismic performance based design, mega-column design, anti-collapse and stability analysis as well as elastic-plastic time-history analysis. Furthermore, under the prerequisite of economic viability and a series of technical requirements prescribed by the expert review panel for high-rise buildings exceeding code limits, the design manages to overcome various structural challenges and realizes the intentions of the architect and the client.

On the effect of steel columns cross sectional properties on the behaviours when subjected to blast loading

  • Hadianfard, Mohammad Ali;Farahani, Ahmad;B-Jahromi, Ali
    • Structural Engineering and Mechanics
    • /
    • v.44 no.4
    • /
    • pp.449-463
    • /
    • 2012
  • For buildings subjected to blast loading, structural failure can be categorized into local failure (direct blast effects) and progressive collapse (consequential effects). In direct blast effects, the intensive blast pressures create localized failure of structural elements such as exterior columns and walls. Columns, and their behaviour, play a key role in these situations. Therefore investigating the behaviour of columns under blast loading is very important to estimate the strength, safety and reliability of the whole structure. When a building is subjected to blast loading, it experiences huge loading pressures and undergoes great displacement and plastic behaviour. In order to study the behaviour of an element under blast loading, in addition to elastic properties of materials, plastic and elastic-plastic properties of materials and sections are needed. In this paper, using analytical studies and nonlinear time-history analysis by Ansys software, the effects of shape of column sections and boundary conditions, on behaviour and local failure of steel columns under blast load are studied. This study identifies the importance of elastic-plastic properties of sections and proposes criteria for choosing the best section and boundary conditions for columns to resist blast loading.

Integrated fire dynamic and thermomechanical modeling of a bridge under fire

  • Choi, Joonho;Haj-Ali, Rami;Kim, Hee Sun
    • Structural Engineering and Mechanics
    • /
    • v.42 no.6
    • /
    • pp.815-829
    • /
    • 2012
  • This paper proposes a nonlinear computational modeling approach for the behaviors of structural systems subjected to fire. The proposed modeling approach consists of fire dynamics analysis, nonlinear transient-heat transfer analysis for predicting thermal distributions, and thermomechanical analysis for structural behaviors. For concretes, transient heat formulations are written considering temperature dependent heat conduction and specific heat capacity and included within the thermomechanical analyses. Also, temperature dependent stress-strain behaviors including compression hardening and tension softening effects are implemented within the analyses. The proposed modeling technique for transient heat and thermomechanical analyses is first validated with experimental data of reinforced concrete (RC) beams subjected to high temperatures, and then applied to a bridge model. The bridge model is generated to simulate the fire incident occurred by a gas truck on April 29, 2007 in Oakland California, USA. From the simulation, not only temperature distributions and deformations of the bridge can be found, but critical locations and time frame where collapse occurs can be predicted. The analytical results from the simulation are qualitatively compared with the real incident and show good agreements.

Comparison of the seismic performance of existing RC buildings designed to different codes

  • Zeris, Christos A.;Repapis, Constantinos C.
    • Earthquakes and Structures
    • /
    • v.14 no.6
    • /
    • pp.505-523
    • /
    • 2018
  • Static pushover analyses of typical existing reinforced concrete frames, designed according to the previous generations of design codes in Greece, have established these structures' inelastic characteristics, namely overstrength, global ductility capacity and available behaviour factor q, under planar response. These were compared with the corresponding demands at the collapse limit state target performance point. The building stock considered accounted for the typical variability, among different generations of constructed buildings in Greece, in the form, the seismic design code in effect and the material characteristics. These static pushover analyses are extended, in the present study, in the time history domain. Consequently, the static analysis predictions are compared with Incremental Dynamic Analysis results herein, using a large number of spectrum compatible recorded base excitations of recent destructive earthquakes in Greece and abroad, following, for comparison, similar conventional limiting failure criteria as before. It is shown that the buildings constructed in the 70s exhibit the least desirable behaviour, followed by the buildings constructed in the 60s. As the seismic codes evolved, there is a notable improvement for buildings of the 80s, when the seismic code introduced end member confinement and the requirement for a joint capacity criterion. Finally, buildings of the 90s, designed to modern codes exhibit an exceptionally good performance, as expected by the compliance of this code to currently enforced seismic provisions worldwide.

PZT Sensor-based Structural Health Monitoring for CFRP Laminated Concrete Structures (CFRP 보강 콘크리트 구조물의 PZT센서 기반 구조 건전성 모니터링)

  • Ryu, Sung-Chan;Kim, Ju-Won;Lee, Chang-Gil;Park, Seung-Hee;Park, Sun-Kyu
    • Journal of the Korea institute for structural maintenance and inspection
    • /
    • v.14 no.5
    • /
    • pp.72-78
    • /
    • 2010
  • A CFRP (Carbon Fiber-Reinforced Plastic) strengthening method is being very widely used to increase the load-carrying capacity of host structures, especially for bridges. However, not only flexure and shear failures but debonding failure also might occur in CFRP strengthened concrete structures. The CFRP debonding failure would cause a collapse accident of the host structure. Therefore, real-time health monitoring about the CFRP bonding condition is strongly required. In this study, a feasibility of the impedance-based damage detection method using PZT sensors is investigated through a series of experimental study monitoring both concrete cracks and CFRP debonding defects.

A Study on the Dynamic Voltage Stability Considering the Power System Security Control (계통(系統)의 안전성(安全性) 제어(制御)를 고려(考慮)한 동적(動的) 전압안정도(電壓安定度)에 관(關)한 연구(硏究))

  • Lee, Geun-Joon;Hwang, Jong-Young;Lee, Gil-Soon;Jeong, Tay-Ho;Kim, Keon-Jung;Kim, Yong-Bae
    • Proceedings of the KIEE Conference
    • /
    • 1994.11a
    • /
    • pp.54-60
    • /
    • 1994
  • The cause of black out of Tokyo Power in 1987 has been identified as the voltage stability problem. After this event many researchers has been interested in voltage stability or voltage collapse phenomena. The voltage instability is different Com the transient stability in the sense of reactive power mismatch and the long duration time. In this study, we developed efficient tool for analyze and control the dynamic voltage instability. To analize specific condition of dynamic voltage stability, quasi-dynamic simulation method is developed. To provide proper mathmatical model for dynamic voltage stability, generator, SVC, OLTC, induction motor models are introducted. To provide specified dynamic voltage stability, the authors considered to use reactive loss function(${\partial}Q/{\partial}p_L$) as reactive power facility control index. This program was tested and identified its usefulness in real KEPCO system.

  • PDF

The Experimental Study on Biochemical Changes of Rat Liver Following Single Irradiation of High Energy X-ray (고(高)에너지 방사선(放射線)을 1회조사(一回照射)한 흰쥐 간(肝)의 생화학적(生化學的) 변화(變化))

  • Lee, Joon-Il;Park, Myeong-Hwan;Park, Chong-Sam
    • Journal of radiological science and technology
    • /
    • v.16 no.2
    • /
    • pp.87-94
    • /
    • 1993
  • In order to investigate radiation effects on the liver, functional changes of liver were analyzed after irradiation. Doses of 10 Gy, 15 Gy and 20 Gy were exposed partially to the liver of male rats(Sprague-Dawley) with X-ray(4MV linear accelerator) at room temperature. On 1, 2, 4 and 8 weeks after irradiation, liver tissues and sera of the animals were compared with those of unirradiated animal by liver function tests. Enzyme activities in sera such as alanine aminotransferase, aspartate aminotransferase, malondialdehyde. The content of malondialdehyde in the activities of many enzymes including alanine aminotransferase, aspartate aminotransferase in sera were increased slightly with increasing exposure dose in all experiments and the activities of these enzymes increased markedly in 20 Gy irradiated groups. From these above results, functional changes of the liver were induced in all irradiated groups. Damaged liver was recovered along with time collapse after irradiation to the doses of 10 Gy and 15 Gy while no recovery was deteced within 8 weeks after irradiation to 20 Gy. These results suggest that careful attention must be paid to liver not to be included in exposure field in radiation therapy.

  • PDF