• Title/Summary/Keyword: Cold test

Search Result 1,532, Processing Time 0.029 seconds

Application of Cold Weather Concrete using Accelerator for Freeze Protection (내한촉진제를 사용한 한중콘크리트의 현장적용)

  • Park, Sang-Joon;Won, Chul;Lee, Sang-Soo
    • Proceedings of the Korean Institute of Building Construction Conference
    • /
    • 2003.05a
    • /
    • pp.13.2-17
    • /
    • 2003
  • When fresh concrete is exposed to low temperature, the concrete may suffer frost damage due to freezing at early ages and strength development may be delayed. One of the solution methods to resolve these problems is to lower freezing temperature of concrete by the use of chemical admixture called Accelerators for Freeze Protection. In this study, it was the results of appling cold weather concrete using Accelerator for Freeze Protection in the Daewoo Trump world field. Before the application of the cold weather concrete using accelerator for freeze protection, we executed the some test in the laboratory and mock-up test in the field. We examined the manifestation of compressive strength complying with the amount of Accelerators for Freeze Protection and curing conditions, and then made a selection of most suitable amount of Accelerators for Freeze Protection.

  • PDF

Performance of cold-formed steel wall frames under compression

  • Pan, Chi-Ling;Peng, Jui-Lin
    • Steel and Composite Structures
    • /
    • v.5 no.5
    • /
    • pp.407-420
    • /
    • 2005
  • This study presents the strength of braced and unbraced cold-formed steel wall frames consisting of several wall studs acting as columns, top and bottom tracks, and bracing members. The strength and the buckling mode of steel wall frames were found to be different due to the change of bracing type. In addition, the spacing of wall studs is a crucial factor to the strength of steel wall frames. The comparisons were made between the test results and the predictions computed based on AISI Code. The related specifications do not clearly provides the effective length factors for the member of cold-formed steel frame under compression. This paper proposes effective length factors for the steel wall frames based on the test results. A theoretical model is also derived to obtain the modulus of elastic support provided by the bracing at mid-height of steel wall frames in this research.

Cold sensitivity classification using facial image based on convolutional neural network

  • lkoo Ahn;Younghwa Baek;Kwang-Ho Bae;Bok-Nam Seo;Kyoungsik Jung;Siwoo Lee
    • The Journal of Korean Medicine
    • /
    • v.44 no.4
    • /
    • pp.136-149
    • /
    • 2023
  • Objectives: Facial diagnosis is an important part of clinical diagnosis in traditional East Asian Medicine. In this paper, we proposed a model to quantitatively classify cold sensitivity using a fully automated facial image analysis system. Methods: We investigated cold sensitivity in 452 subjects. Cold sensitivity was determined using a questionnaire and the Cold Pattern Score (CPS) was used for analysis. Subjects with a CPS score below the first quartile (low CPS group) belonged to the cold non-sensitivity group, and subjects with a CPS score above the third quartile (high CPS group) belonged to the cold sensitivity group. After splitting the facial images into train/validation/test sets, the train and validation set were input into a convolutional neural network to learn the model, and then the classification accuracy was calculated for the test set. Results: The classification accuracy of the low CPS group and high CPS group using facial images in all subjects was 76.17%. The classification accuracy by sex was 69.91% for female and 62.86% for male. It is presumed that the deep learning model used facial color or facial shape to classify the low CPS group and the high CPS group, but it is difficult to specifically determine which feature was more important. Conclusions: The experimental results of this study showed that the low CPS group and the high CPS group can be classified with a modest level of accuracy using only facial images. There was a need to develop more advanced models to increase classification accuracy.

A Study of the Precise Flow Measurement using Coriolis flowmeter (코리올리 유량계를 이용한 정밀유량측정에 관한 연구)

  • Kim, In-Tae;Cho, Dae-Kee;Jeong, Min-Je;Lee, Jae-Won;Seo, Hyuk;Yu, Myoung-Jong
    • Proceedings of the Korean Society of Propulsion Engineers Conference
    • /
    • 2008.05a
    • /
    • pp.61-64
    • /
    • 2008
  • For the performance evaluation of liquid mono-propellant thruster, Vacuum Hot-fire test is necessarily required. An accurate flow measurement is one of the key parameters to the successful T&E program. This paper describes the characteristics of the coriolis flowmeter, explains the cold-flow test using simulant propellant (DIW), and presents the test results. Finally, the cold test results have been verified in comparison with the hot-fire test data.

  • PDF

Study for a Secondary Air Affecting Fluid Flow in a Solid Waste Incinerator (쓰레기 소각로의 2차공기가 유동현상에 미치는 현상 연구)

  • Lee, Geum-Bae
    • Transactions of the Korean Society of Mechanical Engineers B
    • /
    • v.20 no.9
    • /
    • pp.2924-2932
    • /
    • 1996
  • As the environmental pollution can be greatly reduced and the waste heat can be also recovered through a combustion of municipal solid waste, the incineration begins to be highlighted recently in our country. But it is very difficult to be operated with constant combustion conditions for a long time as the domestic waste is composed of various components, contains a large percentage of water, and has a low heating value. Therefore, the cold flow test and partial hot flow test were conducted in the incinerator by use of injection angles of a secondary air affecting fluid flow as the first action to maintain the optimum combustion conditions. A model to a scale of 1:10 was designed and manufactured through the similarity of model and prototype flows. Velocities and temperatures were measured through the experiment. From the results, fluid flows of secondary air obtained from partial hot flow test correspond almost well with those of main flow obtained from cold flow test. Consequently, injection angles of secondary air are proved to affect main flow decisively.

Effect of Operating Conditions on Cold Startup of PEMFC Stack (운전조건에 따른 PEMFC 스택 냉시동 특성 연구)

  • Ko, Jae-Jun;Lee, Jong-Hyun;Kim, Sae-Hoon;Ahn, Byung-Ki;Lim, Tae-Won
    • Transactions of the Korean hydrogen and new energy society
    • /
    • v.20 no.3
    • /
    • pp.224-231
    • /
    • 2009
  • The improvement of cold start capability is one of the most challenging tasks to be solved for commercialization of fuel cell vehicle. In this study, cold start test and ice blocking test(IBT) of fuel cell stack were carried out under various operating conditions. This fuel cell stack can be thawed from -20$^{\circ}$C within 25s and the voltage change was found to be comprised of 4 steps; the first step is the voltage decrease by overpotential, the second step is the voltage increase by the cell temperature increase, the third step is the voltage decrease by ice blocking, and the last step is the voltage increase by thawing. Bootstrap startup was failed after shutdown at temperature under 40$^{\circ}$C because of much condensed water in the fuel cell. Quantitative estimation of cold start capability have been demonstrated by ice blocking test(IBT). In the results, it was found that cold start capability was improved double every 10$^{\circ}$C from 30$^{\circ}$C to 65$^{\circ}$C and enhanced by 30% at the condition of SR 3/4 compared to SR 1.5/2.0 and enhanced by 20% with dry purge condition compared to with RH 50% purge condition.

Effects of a warmed blanket for the relieving of cold discomfort after Cesarean Section (저온불편감 완화를 위한 가온담요의 효과 - 제왕절개술 산모를 대상으로 -)

  • Jung Hyang-Mee;Kim Myung-Hee
    • Journal of Korean Academy of Fundamentals of Nursing
    • /
    • v.7 no.1
    • /
    • pp.16-29
    • /
    • 2000
  • The purpose of this study was to examine the effects of a warmed blanket on relieving the cold discomfort after Cesarean Section delivery. A nonequivalent control group pre-test/post-test design was used for this quasi-experimental study. Sixty women were recruited for this study and divided by two groups: experimental and control groups. Blankets warmed to $40^{\circ}C$ were applied to the women in the experimental group for one hour and unwarmed blankets were applied to the control group. Using Abbey's shivering scales, subjective thermal sensation score, and Celsius mercury thermometer, cold discomfort was measured at four time points: 1) baseline measure (at the point the blanket was applied) 2) 15 min. later, 3) 30 min. later, and 4) 45 min. after application. Data were analyzed using SPSS/WIN and t-test and MANOVA were used to examine the effects of the warmed blanket for relieving cold discomfort. The results of the study are as follows. The experimental group had less cold discomfort than the control group(Wilts's value =0.580, p=0.000) at the 45 minute point after blanket application. the Experimental group reported less shivering and subjective thermal sensation than the control group. Shivering scores showed significant differences between the two groups at each of the four time points (baseline, 15 min., 30 min., and 45 min.) and subjective thermal sensation score showed significant differences between two groups at 45 minutes. after blanket application. In conclusion, the application of a warmed blanket was more effective on shivering and subjective thermal sensation than body temperature measured by objective means. Because women in this study were in the normal range of body temperature, differences in the objective body temperature between the two groups may not be sensitive enough to be detected. Even though differences in objective body temperature were not found, reduced subjective discomfort for low body temperature may be a sufficient significant finding in for nurse clinicians to utilize this method on their practice. Further studies in this area are needed to support these findings.

  • PDF

A Study on the Effects of Side Jets to the Longitudinal Aerodynamics of Subsonic Missile (측방 제트가 아음속 유도탄 종방향 공력특성에 미치는 영향 연구)

  • GO, Beom Yong;HUR, Ki Hoon
    • Journal of the Korea Institute of Military Science and Technology
    • /
    • v.20 no.3
    • /
    • pp.393-404
    • /
    • 2017
  • Side jet effect on the aerodynamic characteristics of a missile was investigated using experimental and computational methods. A couple of side jets were injected toward outward downstream at mid point of missile body. Cold air jet was used in the wind tunnel test, and cold and hot jet were used in the computation. Wind tunnel test was carried out with jet and without jet, and calculation was performed for three cases ; no jet, cold air jet, and hot mixture gas jet. From the comparison of measured and calculated data for all cases, two points could be deduced. Firstly, side jet made static stability to be unstable by increasing body normal force near the side jet exit and by decreasing tail normal force. Secondly, hot mixture gas had more significant effect on the static stability of a missile-type body than cold air jet.

Field Application of Surface Insulation Curing Method to Cold Weather Concreting (한중콘크리트의 현장 표면단열 양생공법 시공사례 연구)

  • Kim Jong-Back;Lim Choon-Goun;Han Min-Cheol;Kim Seoung-Soo;Han Cheon-Goo
    • Proceedings of the Korean Institute of Building Construction Conference
    • /
    • 2005.11a
    • /
    • pp.25-28
    • /
    • 2005
  • This study investigates the field application of surface insulation curing method, which combined double layer bubble sheet(DBS) and thick-curing-material(TCM) for cold weather concreting. According to the test, deck slab, curing only upper section with DBS and TCM, does not make big different temperature history with that, curing both upper and bottom section during daily average temperature 6.5t. It is concluded that combination of DBS and TCM in only upper section can be safely cured in early period of time during cold water concreting. The field test was carried out with this favourable data. The upper deck slab was insulated by combination of DBS and TCM, and the construction was surrounded by tent. in order to protect from outside wind. The test result shows that the lowest temperature of deck slab indicated 6$ ^{circ}C $. It demonstrated that this curing method can resist early frost and save construction cost in the side of management and saving labor cost, compared with previous method. In addition, the column specimen, combined both form and bubble board, exhibited favorable temperature history, due to internal hydration heat insulation effect.

  • PDF