• Title/Summary/Keyword: Cold test

Search Result 1,532, Processing Time 0.033 seconds

Mild Cold Stimulus on Forehead of Healthy Men and Heart Rate Variability (이마의 냉각자극이 건강인의 심박 변이율에 미치는 영향에 대한 실험적 연구)

  • Kim Ki-Hwan;Park Kyung-Mo
    • Journal of Physiology & Pathology in Korean Medicine
    • /
    • v.19 no.5
    • /
    • pp.1191-1194
    • /
    • 2005
  • The aim of this study was to investigate the change of Heart Rate Variability(HRV) that mild cold stimulus on the forehead of healthy men induces. 34 healthy male subjects participated in the experiments. On the first test series, 15 subjects were applied to the mild cold stimulus by the devise for cold stimulation. In the second test series, 10 subjects With heat Syndrome and 5 subjects With cold Syndrome were applied to the mild cold Stimulus. Aa a additional test, 4 subjects with cold syndrome were applied to the warm stimulus in the last test series. We analyzed the HRV through measuring electrocardiogram.(ECG). The result of this study is comparatively clear. In the first test series, mild cold stimulus made parasympathetic nervous system be activated. In the second test series, mild cold stimulus made parasympathetic nervous system be activated both in subjects with heat syndrome and subjects with cold syndrome, and heat syndrome shows more active parasympathetic nervous system rather than cold syndrome subjects do. In the last test series, 2 subjects with cold syndrome respond the mild cold stimulus. That means warm stimulus of cold condition subjects made parasympathetic nervous system active in 2 of 4 subjects. We found out that mild cold stimulus on forehead makes parasympathetic nervous system be activated in healthy male, and it can be interpreted that mild cold stimulus make healthy human be relaxed. Also, subjects have different fondness of thermal stimulus according to their Cold or Heat condition Preferences. Last test series shows that we need to investigate effect of the warm stimulus heat syndrome subjects.

Design of Cold-flow Test Equipment Considering Dynamic Similarity for DACS Verification (동적상사를 고려한 DACS 검증용 공압 시험장치 설계)

  • Bae, Sangho;Chang, Hongbeen;Park, Iksoo
    • Proceedings of the Korean Society of Propulsion Engineers Conference
    • /
    • 2017.05a
    • /
    • pp.374-377
    • /
    • 2017
  • A cold-flow test equipment was designed to carry out the performance verification of TDACS. For that purpose, the pressure dynamics in the solid rocket motor combustor and the cold-flow test was modeled, and the response time showing the dynamic characteristics of each model was obtained. In this paper, the system response time of the cold-flow test was designed to be equal to that of the motor, making the dynamic response in cold-flow and hot gas condition to be similar.

  • PDF

Performance Evaluation of Cold-Recycling Asphalt Mixtures with an Inorganic Additive (무기질 첨가제를 사용한 상온 재활용 아스팔트 혼합물의 공용성 평가)

  • Kim, kyungsoo;Kim, HyunKyum;Kim, WonJae;Park, ChangKyu;Lee, HyunJong
    • International Journal of Highway Engineering
    • /
    • v.20 no.1
    • /
    • pp.27-33
    • /
    • 2018
  • PURPOSES : The purpose of this study is to estimate the optimum content of an inorganic additive for cold-recycled asphalt mixtures and evaluate its performance. METHODS : An indirect tensile test, a tensile-strength ratio test, and an indirect tensile-fatigue test were conducted on cold-recycling asphalt mixtures with various additives. RESULTS : The laboratory performance tests indicated that granulated blast-furnace slag mixed with inorganic and cement activators provided optimum performance. The performance results of the cold-recycled asphalt pavement were similar to the inorganic and cement activators' performance in terms of the indirect tensile strength, tensile strength ratio, and indirect tensile-fatigue test. CONCLUSIONS : Overall, the performance of a cold-recycled asphalt mixture using inorganic additives and emulsion asphalt was comparable to a warm-recycled asphalt mixture. However, more experiments aimed at improving its performance and studying the effect of the inorganic additives must be conducted.

Cold Cracking Susceptibility in Weld Metal of High Strength-Toughness Steel (고강도 고인성강 용접금속의 저온균열 감수성에 관한 연구)

  • 이종봉;안상곤;안영호;김영우
    • Journal of Welding and Joining
    • /
    • v.13 no.4
    • /
    • pp.46-54
    • /
    • 1995
  • The cold cracking susceptibility of a variety of weld metals deposited by GMAW with several kinds of commercial solid wires for high strength-toughness steel was investigated. G-BOP test and LB-TRC test were carried out to study the effects of preheat, chemical composition and hydrogen level on the weld metal cold cracking. The results obtained are as follows. 1) 10% CPT obtained by G-BOP test was the most valuable criteria for evaluating the cold cracking susceptibility of weld metals compared with percentage of cracking at room temperature and crack free temperature, and it had good correlation with the results of LB-TRC test. 2) Cold cracking susceptibility of weld metals was high in the row of MG100A, MG100C, MG100D and MG100B. Welds deposited with MG130 and MG80 showed similar icidents of cracking with MG100C and MG100B respectively, even though their strength levels were different. 3) Diffusible hydrogen level in weld metals which has good relation with hydrogen content in wire itself was the most critical factor for controlling the cold cracking susceptibility of weld metal.

  • PDF

Cold stress test for the diagnosis of cold hypersensitivity on hands (냉부하검사를 통한 수부냉증의 진단)

  • Han, Ji-Young;Joe, Jung-Hoon;Jang, Jun-Bock;Kim, Yong-Suk;Lee, Kyung-Sub
    • Journal of Oriental Medical Thermology
    • /
    • v.2 no.1
    • /
    • pp.17-23
    • /
    • 2003
  • Purpose The cold hypersensitivity is a subjective symptom and it is very difficult to evaluate the severity. It is possible to detect cold hypersensitivity by measuring the skin temperature on DITI, but there is limitation only using DITI to find the objective grade of the symptom. To set a new objective standard for the diagnosis of cold hypersensitivity, we examined the relationship between the Visual Analogue Scale (VAS) score for the cold hypersensitivity and the change of skin temperature on hands by cold stress test Method 23 patients with symptom of cold hypersensitivity were participated as subjects who visited the women medical center of Kangnam Kyunghee Korean Hospital, Kyung Hee Univ. from May 1, 2002 to August 31, 2002. There were all carefully examined to rule out other disease such as obesity, skin diseases, spinal nerve lesions and external wounds. Thermographic observations for this study were made using DITI. We performed cold stress test three times to compare with the results from thermographic observations by DITI: first, after 15 minutes-resting, second, right after 1 minutes soak in $20^{\circ}C$ water, the third for last, 10 minutes after the soak. VAS score was chosen to determine the severity of cold hypersensitivity. Result 1 male and 22 female patients were participated ranging in age from 22.17 to 45.21. There was a significant negative correlation between the recovery rate of finger skin temperature after cold stress test and the VAS score. And there was a significant positive correlation between the difference of finger skin temperature and the back and palm of hands after cold stress test and the VAS score. Conclusion In cold hypersensitivity patients, the cold stress test combined with DITI could be a accurate method for the objective evaluation of cold hypersensitivity, especially good at deciding the severity by numeric values. Using a more strict criterion, as diagnosing of cold hypersensitivity, and longer follow-up may improve the validity of the results attained in clinical trials.

  • PDF

Health Test for Searching of Correlation and the Index of the Cold-heat Patternization Comparison of the Questionnaires for the Cold-heat Patternization and the Ordinary (한열변증 설문지와 일반적 건강 검진 결과와의 상호 연관성에 관한 비교 연구)

  • Baek, Tae-Seon;Park, Young-Jae;Park, Young-Bae;Park, Jae-Hyung;Im, Jae-Joong
    • The Journal of the Society of Korean Medicine Diagnostics
    • /
    • v.9 no.2
    • /
    • pp.145-151
    • /
    • 2005
  • Background and purpose: The cold-heat patternization is one of the most frequently use for diagnostic method in oriental medicine. But it is still an unclear scientific mechanism and the objective index. the aim of this study is to search the objective index of the cold-heat patternization, comparing with ordinary health test. Method: The study group comprised 101 Korean, male:female ratio 51:50, with a mean age of 49.74 years. The results of the questionnaires for cold-heat patternization were compared with the western health test that it consist of height, weight, muscle mass, body fat, WBC, Hb, ALT, AST, TG, Total cholesterol, glucose, HDL-cholesterol, free-T4 and TSH, measured in the health promotion center of the hospital of Chungnam university Result: The cold patternization were significantly higher in the women than the man. The somothing of the questionmaires for the heat patternization were positive correlated with TG, TSH, glucose, Hb, free T4, weight, musle mass(p<0.05). But there were no correlation in the gross. The somothing of the questionnaires for the cold patternization were negative correlated with the weight, musle mass, body fat, glucose, Hb and ALT(p<0.05), Especially there were strong negative correlation with the weight and muscle mass(p<0,01). Conclusion: The present study shows there is no definitive index for the cold-heat patternization in the ordinary health test. But the weight and muscle mass can be useful index of the cold patternization.

  • PDF

The Effect of Hot and Cold Water for The Hand Dexterity on Patients with Hemiplegia (냉·온수적용이 편마비환자의 손기민성에 미치는 영향)

  • Hwang, Seong-Soo;Cho, Eun-Sook;Ko, Ji-Young;Jang, Eun-Jung;Joo, Jae-Uk;Son, Jung-Il;Sim, Hee-Jung;Lee, Jong-Hyeon
    • PNF and Movement
    • /
    • v.9 no.1
    • /
    • pp.65-73
    • /
    • 2011
  • Background : This study was to investigate effect of hot and cold water for the hand dexterity. Methods : A total of 37 subjects having hemiplegia(men=6, women=11) and normal(men=10, women=10) were participated in this study. After both hands was soaked in the small tube for 1 minute, we measured 'making dots in circles(BOTMP)', 'lifting small objects(JHFT)', 'disk turning(MMDT)' test. Results : In the case of normal's dominant hand, there were statistically significant differences in all tests after soaked in the hot water but there were statistically significant differences in 'disk turning' test after soaked in the cold water. In the case of hemiplegia's unaffected hand, there were statistically significant differences in 'disk turning' test after soaked in the hot water but there were statistically significant differences in 'making dots in circles', 'disk turning' test after soaked in the cold water. In the case of hemiplegia's affected hand, there were statistically significant differences in 'lifting small objects', 'disk turning' test after soaked in the hot water but there were statistically significant differences in 'making dots in circles', 'disk turning' test after soaked in the cold water. Conclusion : The hot and cold water were affected in the hand dexterity. Especially, in the case of both normal and hemiplegia, there were statistically significant differences in 'disk turning' test after soaked in the cold and hot water. Therefore, We were founded that affected in gross movement than fine movement.

Study of the Curing Time of Cementless Cold Central Plant Recycled Asphalt Base-Layer through Field-Application Review (무시멘트 상온 재활용 아스팔트 기층의 현장 적용성을 통한 양생기간에 관한 연구)

  • Choi, Jun Seong;Jung, Chul Ho;Lee, Chan Hee;Lim, in su
    • International Journal of Highway Engineering
    • /
    • v.19 no.2
    • /
    • pp.67-74
    • /
    • 2017
  • PURPOSES : The objective of this study is to ascertain the curing period of cementless cold central plant recycled asphalt base-layer, using mechanical analyses and specimen quality tests on the field. METHODS : Cold central plant recycled asphalt base-layer mixture was produced in the plant from reclaimed asphalt, natural aggregate, filler for the cold mix, and the modified emulsion AP using asphalt mix design and plant mix design. In order to examine the applicability of the curing period during the field test, the international standards for the possibility of core extraction and the degree of compaction and LFWD deflection were analyzed. Moreover, Marshall stability test, porosity test, and indirect tensile strength test were performed on the specimens of asphalt mix and plant mix design. RESULTS : The plant production process and compaction method of cementless cold central plant recycled asphalt base-layer were established, and the applicability of the optical moisture content for producing the mixture was verified through the field test. In addition, it was determined that the core extraction method of the conventional international curing standard was insufficient to ensure performance, and the LFWD test demonstrated that the deflection converges after a two-day curing. However, the back-calculation analysis reveals that a three-day curing is satisfactory, resulting in a general level of performance of dense asphalt base-layer. Moreover, from the result of the specimen quality test of the asphalt mix design and plant mix design according to the curing period, it was determined that the qualities satisfied both domestic and international standards, after a two-day curing. However, it was determined that the strength and stiffness after three-day curing are higher than those after a two-day curing by approximately 3.5 % and 20 %, respectively. CONCLUSIONS:A three-day curing period is proposed for the cementless cold central plant recycled asphalt base-layer; this curing period can be demonstrated to retain the modulus of asphalt-base layer in the field and ensure stable quality characteristics.

The Cold Function Test of a Main Cooling Water System for a Nuclear Fuel Test Loop Installed in HANARO (하나로 핵연료 시험장치의 주냉각수 계통 상온기능시험)

  • Park, Young-Chul;Lee, Young-Sub;Chi, Dai-Yong
    • Proceedings of the KSME Conference
    • /
    • 2008.11b
    • /
    • pp.2505-2510
    • /
    • 2008
  • A nuclear fuel test loop (after below, FTL) is installed in IR1 of an irradiation hole in HANARO for testing neutron irradiation characteristics and thermo hydraulic characteristics of a fuel loaded in a light water power reactor or a heavy water power reactor. When HANARO is normally operated, the fuel loaded in the irradiation hole has a nuclear reaction heat generated by a neutron irradiation. To remove the generated heat and to maintain an operation condition of the test fuel, a main cooling water system (MCWS) is installed in the OPS of the FTL. This paper describes the cold function test results of the MCWS. It was confirmed through the test results that the system met the design requirements under a cold operation condition.

  • PDF

Cold Tolerance Characteristic Test of High Yield Tongil-type Rice Breeding Lines for Processing

  • Kang-Su Kwak;Sea-Kwan Oh;Kuk-Hyun Jung;Dae-Ha Seo
    • Proceedings of the Korean Society of Crop Science Conference
    • /
    • 2022.10a
    • /
    • pp.278-278
    • /
    • 2022
  • Recently, the yield potential of high yield Tongil-type rice varieties has greatly increased, reaching 817kg/10a(Geumgang No.1). Moreover, in order to promote rice consumption and strengthen the competitiveness of the rice processing industry, the R&D of high yield Tongil-type rice varieties for each processing purpose, such as rice noodles, grain feed and industrial materials, has been continuously carried out. However, because Tongil-type rice varieties or lines are generally very vulnerable to cold damage, cold tolerance test can be said to be absolutely necessary to improve the cultivation safety. This study is the result of the seedling and field cold tolerance characteristic tests carried out in 2021 of high yield Tongil-type rice breeding lines. For the cold tolerance characteristic test of seedlings, total 303 high yield rice breeding lines for processing were treated in cold water of 13℃ and irrigation depth of 4cm for 10 days from the third-leaf age, then it was evaluated by comparing the degree of discoloration and withering with the checked varieties(Boramchan, Hanahreum No.2). Also, for the test of field, total 186 high yield rice breeding lines for processing were treated in cold water of 17℃ by keeping pouring day and night from 30 days after transplanting to ripening stage, then it was evaluated by comparing the degree of discoloration, delay of heading, shortening rate of stem length and percent of fertile grain etc. with the checked varieties. And the cold tolerance evaluative criteria were classified as strong(1~3), medium(4~6) and weak(7~9) in overall cold tolerance. (Seedling test) As for the degree of cold tolerance of the check variety, 'Boramchan' and 'Hanahreum No.2' showed a response of 'medium' and 'weak', respectively. However, there was no 'strong' line in the high yield rice breeding lines, 2 lines showed a 'medium' response, and 301 lines showed a 'weak' response. Therefore, except for a few lines(0.7%), most lines(99.3%) showed a 'weak' response. (Field test) In terms of the overall cold tolerance of the check variety, both 'Boramchan' and 'Hanahreum No.2' showed a 'medium' response. Similarly, there was no 'strong' line in the case of high yield rice breeding lines, 20 lines showed a 'medium' response, and 166 lines showed a 'weak' response. Therefore, except for some(10.8%) lines, most(89.2%) lines showed a 'weak' response. From the above results, we selected about 100 individuals with less seed shattering and degeneration of the ear tip, and with a relatively high percent of fertile grain, and are continuing to select lines with improved cold tolerance in the F4~F5 group in this year. As such, most of the Tongil-type rice varieties have poor cold tolerance and thus have low cultivation safety at low temperatures. However, it is important to select improved lines through generational progress because there are some lines that still have a certain level of cold tolerance among them.

  • PDF