• Title/Summary/Keyword: Cold storage

Search Result 942, Processing Time 0.029 seconds

A Study on the New Trend of The Consumption District Cold Storage Warehouse Industry in Japan - Focused on Japan Capital region - (일본 소비지 냉동냉장창고의 새로운 움직임 -수도권 냉동냉장창고를 중심으로 -)

  • Chang Hong-Seock
    • The Journal of Fisheries Business Administration
    • /
    • v.37 no.2 s.71
    • /
    • pp.111-139
    • /
    • 2006
  • Cold storage warehouse industry in Japan has been extended in its scale in terms of both the number of storages and cold storage capacity in order to meet the extended reproduction of the marine products industry. However, increasing total amount of the stored goods since mid 80s led to relative decrease of marine products while the number of storages was remained the same or decreased, though cold storage capacity was gradually increased and is maintained the increase of the average cold storage capacity. As structural change in the cold storage warehouse industry emerges, cold storage warehouses require new approach to individual storage management with 1)diversity of the stored goods; 2) more competition due to increase of the cold storage capacity; and 3) sizing of the average cold storage capacity. Therefore, this study analyzed how cold storage warehouse management activity with individual storage sizing changes; and significance of sizing and functional change in cold storage warehouses experiencing sizing, by observing leading cold storage warehouse industry of the metropolitan area in Japan. In conclusion, reorganization of cold storage warehouse industry in the metropolitan area in Japan can be summarized as follows: First, competition among cold storage warehouses in the metropolitan area in Japan is not simply limited to storage industry but extended to establishment and securing physical distribution function. Second, since cold storage warehouse industry is in Scrap & Build phase, decision of management executives on whether taking direction to maintain/continue enhancement of physical distribution function may cause drastic reorganization in the cold storage warehouse industry, Third, since profit of physical distribution management based on cold storage warehouses is insignificant, it is not easy to accomplish expected management outcome, Fourth, today's cold storage warehouse industry mainly characterized by diversity of the stored goods needs facility reorganization with comprehensive and functional integration covering from F class cold storage capacity to F&C class.

  • PDF

Enhancement of the round-trip efficiency of liquid air energy storage (LAES) system using cascade cold storage units

  • Kim, Jhongkwon;Byeon, Byeongchang;Kim, Kyoung Joong;Jeong, Sangkwon
    • Progress in Superconductivity and Cryogenics
    • /
    • v.22 no.4
    • /
    • pp.45-50
    • /
    • 2020
  • In this research, the variation of round-trip efficiency in a liquid air energy storage system (LAES) is calculated and an optimal configuration is found. The multiple stages of cold energy storage are simulated with several materials that process latent heat at different temperature ranges. The effectiveness in the charging and discharging processes of LAES is newly defined, and its relationship with the round-trip efficiency is examined. According to defined correlation, the effectiveness of the discharging process significantly affects the overall system performance. The round-trip efficiency is calculated for the combined cold energy storage materials of aqueous dimethyl sulfoxide (DMSO) solution, ethanol, and pentane theoretically. The performance of LAES varies depending on the freezing point of the cold storage materials. In particular, when the LAES uses several cold storage materials, those materials whose freezing points are close to room temperature and liquid air temperature should be included in the cold storage materials. In this paper, it is assumed that only latent heat is used for cold energy storage, but for more realistic analyzes, the additional consideration of the transient thermal situation to utilize sensible heat is required. In the case of such a dynamic system, since there is certainly more increased heat capacity of the entire storage system, the volume of the cold energy storage system will be greatly reduced.

Study on Demand Prediction of Cold Storage Facilities (냉동냉장설비의 수요예측에 관한 연구)

  • Son, Chang-Hyo;Oh, Hoo-Kyu
    • Korean Journal of Air-Conditioning and Refrigeration Engineering
    • /
    • v.23 no.9
    • /
    • pp.587-594
    • /
    • 2011
  • This paper describes the investigation on current state of cold storage facilities, and analysis on the demand prediction in the near future. And based on the analysis results, we prospect the scale of cold storage facilities in the near future. The main analysis results are summarized by the followings ; The present circumstances of cold storage facility are determined by investigating actual loading capacity, average stock amounts, and return number of cold storage facility. From the results, the present situation for cold storage facility is about 3% over. It is found that the average stock amounts increase gradually, and accordingly that the demand of cold storage facility is predicted to be increased, resulting that the capacity of cold storage facilities in 2013 expects to reach up to 5,250,000 ton. It is considered that the results of demand prediction has significant implications on the management of cold storage facility in the near future.

Experimental Study on the Cold Storage of Spherical Capsules in the Cylindrical Tank (원통형 축냉조내 구형캡슐들의 축냉에 관한 실험 연구)

  • ;;Jung, Gab Yong
    • Transactions of the Korean Society of Mechanical Engineers
    • /
    • v.19 no.10
    • /
    • pp.2647-2656
    • /
    • 1995
  • The present work was performed to axially and radially investigate the local cold storage performance in the cylindrical tank with the spherical capsules inserted n-Tetradecane as a new cold storage material. The local cold storage performance of the capsules in the tank was experimentally investigated for the inlet temperature of -7, -5, -3, 0.deg. C, for the flow rate of 0.95, 1.89, 2.84, 6.00 l/min, and for the diameter ratio of 4.9, 9.0, 13.1. The local cold storage performance in the case of using water applied for the commercial ice-ball system was axially investigated by changing the flow rate only with the inlet temperature of -7.deg. C and the diameter ratio of 9.0 in order to compare with the performance in the case of using n-Tetradecane. For the case of using n-Tetradecane, the difference of cold storage period between the first and the seventh story was increased as the inlet temperature was increased and the flow rate was decreased. The capsules at the center of the tank showed the supercooling and the increased cold storage period compared with the capsules at the wall of the tank due to the small porosity and insufficient cold storage performance at the center of the tank as the diameter ratio is increased. The case using water showed worse cold storage performance due to comparatively large supercooling than the case using n-Tetradecane.

Experimental Study of the Effect on Cabin Thermal Comfort for Cold Storage Systems in Vehicles (축냉 시스템이 차 실내 열 쾌적성에 미치는 영향에 관한 실험적 연구)

  • Lee, Daewoong
    • Transactions of the Korean Society of Automotive Engineers
    • /
    • v.23 no.4
    • /
    • pp.428-435
    • /
    • 2015
  • This paper presents the experimental study of cabin thermal comfort using a cold storage heat exchanger in a vehicle air-conditioning system. Recent vehicle-applied ISG functions for fuel economy and emission, but when vehicles stop, compressors in the air-conditioning system stop, and the cabin temperature sharply increases, making passengers feel thermal discomfort. This study conducts thermal comfort evaluation in the vehicle, which is applied to a cold storage system for the climate control wind tunnel test and the vehicle fleet road test with various airflow volume rates and ambient temperatures blowing to the cold storage heat exchanger. The experimental results, in the cold storage system, air discharge temperature is $3.1-4.2^{\circ}C$ lower than current air-conditioning system when the compressor stops and provides cold air for at least 38 extra seconds. In addition, the blowing airflow volume to the cold storage heat exchanger with various ambient temperature was examined for the control logic of the cold storage system, and in the results, the airflow volume rate is dominant over the outside temperature. For this study, a cold storage system is economically useful to keep the cabin at a thermally comfortable level during the short period when the engine stops in ISG vehicles.

Development of Dome-Type Cold Storage Facility Using 3-D CFD Simulation (3차원 CFD 시뮬레이션을 이용한 돔형 저온저장고 개발)

  • 양길모;고학균;홍지향
    • Journal of Biosystems Engineering
    • /
    • v.28 no.1
    • /
    • pp.35-44
    • /
    • 2003
  • This study was conducted to develop proper model for cold storage facility that could of for uniform heat movement and air movement f3r green grocery and improve improper design of the existing container-type cold storage facility. For that reason, new model(dome-type) cold storage facility was developed using 3-D CFD(computational fluid dynamics) simulation. The size was 6m${\times}$6m${\times}$5m. Its size and configuration were same to simulation model. Unit cooler was designed to send cold air in 4 side ways. A dome-type cold storage facility showed uniform distributions of air temperature and velocity because cold air was forced to move down along the ceiling and the wall and then circulated to the unit cooler from the central part of the floor. Dome-type cold storage facility also showed by low wind velocity, below 1 m/s that could minimized cold damage and quality deterioration.

3-D Simulation of Air Flow in Cold Storage Room for Uniform Temperature Distribution (저온저장고 내부의 균일한 온도분포를 위한 3차원 공기유동 분석)

  • 성제중;고학균;조성인;양길모
    • Journal of Biosystems Engineering
    • /
    • v.25 no.4
    • /
    • pp.279-286
    • /
    • 2000
  • Most of the domestic cold storage rooms are inefficient for agricultural products because of temperature gradients inside the storage rooms. Temperature gradients are developed mainly by improper airflow pattern inside the storage room, which is a main cause of the spoilage of the agricultural products. There proper airflow pattern is essential to minimize these temperature gradients and the spoilage. The performance and characteristics of a cold storage room were determined as a function of airflow pattern and temperature distribution in forced circulation cold storage room. A commercial CFD(computational fluid dynamics) code was used to simulate 3-D airflow in the cold storage room. Solving the flow equations for the storage room, a standard k-$\varepsilon$ turbulent model was implemented to calculate steady state turbulent velocity distribution. The CFD prediction results were compared with temperature measurements inside the cold storage room. In case of pallet storage, Temperature gradients inside pallet storage was reduced because the contact area of cold air expanded through an alley of airflow in storage. But is case of bulk storage, the last temperature of storage considerably rose more than the initial temperature of storage. The reason was that bulk storage didn't include any alley of airflow in storage.

  • PDF

Feasibility Study of Cold Storage System to Maintaining Cooling Performance for ISG Vehicle (공회전 제한장치 차량에서 냉방 성능 유지를 위한 축냉 시스템 적용에 대한 연구)

  • Lee, Daewoong
    • Korean Journal of Air-Conditioning and Refrigeration Engineering
    • /
    • v.28 no.1
    • /
    • pp.7-14
    • /
    • 2016
  • This study explores the feasibility of a cold storage system to provide thermal comfort for idle stop and go (ISG) vehicles. ISG function is the most valuable and environmental friendly technology in the current automobile industry. However, when an ISG vehicle stops, meaning when the engine standstill, the air-conditioning system does not work, because the compressor also stops. Therefore, passenger thermal comfort is not maintained, as cold air is not provided in the cabin. Consequently, many automakers have studied electric air-conditioning systems based on electrically-driven compressors or cold storage systems using phase-change materials. The experiments herein were conducted for the feasibility testing of different types of cold storage heat-exchangers, cold storage mediums, and thermo-expansion valves with current air-conditioners. The auxiliary cold storage system, filled with phase-change materials, was located behind the evaporator and almost stacked on top of it. In the experimental results, the air discharge temperature rate of increase was better than the conventional air-conditioning system when the compressor stopped and thermal comfort was maintained with $1.9{\sim}4.3^{\circ}C$ decreases within 60 seconds. The #1 cold storage heat-exchanger (CSH), #2 thermo-expansion valve (TXV) and #2 phase change material (PCM) were chosen because of the best temperature rise delay. It was concluded that a cold storage system is an effective solution for ISG vehicles to maintain thermal comfort during short engine stops.

Changes of Composition in Immature Green Persimmons during Storage (풋감의 저장 중 성분변화)

  • 김효선;고정순;이장순
    • The Korean Journal of Food And Nutrition
    • /
    • v.9 no.4
    • /
    • pp.478-483
    • /
    • 1996
  • We investigated the changes of composition in immature green persimmon during cold(7$^{\circ}C$) and freezing (-2$0^{\circ}C$) storage for 30 days. Moisture, protein, fat and carbohydrate were not significantly different by storage temperature and storage days. Crude fiber had little change during freezing storage, but in case of cold storage, as storage time goes by, it slightly deceased. Content of polyphenol was increased during cold and freezing storage, especially during cold storage it was remarkably increased. Content of total pectin was decreased, while content of soluble pectin was increased during cold storage. Content of total pectin and soluble pectin was slightly decreased or increased during freeze storage. Content of tannin had little change during freezing storage but it significantly decreased during cold storage.

  • PDF

Present Situation and Analysis of Cold Storage Facilities for Fisheries Products (수산물 냉동냉장설비의 현황 및 분석)

  • Son, Chang-Hyo;Oh, Hoo-Kyu
    • Korean Journal of Air-Conditioning and Refrigeration Engineering
    • /
    • v.23 no.6
    • /
    • pp.406-412
    • /
    • 2011
  • This paper describes the analysis on freeze and refrigeration capacity of cold storage facilities for fisheries products during the last 15 years. And based on the analysis results, we prospect the number and scale of cold storage facilities in the near future. The main analysis results are summarized by the followings; Under the present conditions, the number and scale of our facilities is 879 and 3,586,824 ton, respectively. In comparison of the present and last 15 years ago, the business number increases about 22%, the accommodation capacity increases approximately 80%. In the reported update reference with the related data during the last 15 years, the capacity of cold storage facilities in 2011 expects to reach up to 4,600,000 ton. The newlyestablished facility in 2011 has the function of a multi-purpose distribution center as well as the existing cold storage, but this facilities converges in the capital area. Therefore, in this paper, we provided the basic reference data for the present situation and prediction of our cold storage facilities. But it is necessary to investigate and analyse widely our cold storage facilities for fisheries products in the near future.