• 제목/요약/키워드: Cold start phase

검색결과 34건 처리시간 0.031초

SI 엔진의 시동 및 아이들 구간에서의 점화시기에 따른 싸이클별 연소현상에 관한 실험적 연구 (An Experimental Study of Cyclic Combustion Characteristics at Starting and Idling Phase on Spark Ignition Engine)

  • 최성원;최관희;명차리;박심수
    • 대한기계학회:학술대회논문집
    • /
    • 대한기계학회 2007년도 춘계학술대회B
    • /
    • pp.3317-3322
    • /
    • 2007
  • THC(Total Hydrocarbon) emissions during cold start and warm-up phase constitute the majority of THC emissions during the FTP-75 mode. As the basic approach to improve the emission performance of Gasoline engine during transient phase, the effect of spark timing retard from MBT on THC emission characteristics is studied by engine test using a Fast response Flame Ionization Detector(FFID). A cyclic analysis of the combustion process shows that high THC emissions are produced first few cycles during the transient phase. This paper presents the results of engine performance and emission of Gasoline engine with various spark timing. consequently, This paper was focused on the combustion phenomena with various spark timing during transient phase which was analyzed by Fast response Flame Ionization Detector (FFID) equipment to measure the cyclic THC emission characteristics.

  • PDF

CVS-75모드에서 사용연료에 따른 배출가스 특성분석 (Characteristics Analysis of Exhaust Emission according to Fuels at CVS-75 Mode)

  • 한성빈;김용태;이호길;강정호;정재우;정연종
    • 에너지공학
    • /
    • 제18권1호
    • /
    • pp.69-73
    • /
    • 2009
  • 자동차로부터 배출되는 배출가스의 규제가 최근 더욱 강화되고 있다. 이러한 엄격해지는 규제는 배출가스를 줄이는 대체연료의 개발에 더욱 박차를 가하게 된다. 본 연구는 가솔린, 디젤, LPG 연료를 사용하는 동급의 자동차를 이용하여 배출가스의 특성을 분석 비교하였다. 테스트 모드로는 최근 국내와 북미 배출가스의 주행모드로 사용되는 CVS-75모드를 사용하였다. 배기 특성은 주행조건에 하에서 연구되어졌다. 사용연료인 가솔린, 디젤, LPG연료에 따라 THC, CO, NOx의 배출가스의 특성을 연구했다. 연구결과, LPG연료에 비해 가솔린자동차가 9.8%의 배출가스 감소, 디젤자동차는 12.2% 증가를 나타냈다. 또한 CVS모드에서 가솔린과 LPG는 phase 1의 냉간시동구간에서 THC와 CO는 80%이상을 나타낸다.

STUDY OF CORRELATION BETWEEN WETTED FUEL FOOTPRINTS ON COMBUSTION CHAMBER WALLS AND UBHC IN ENGINE START PROCESSES

  • KIM H.;YOON S.;LAI M.-C.
    • International Journal of Automotive Technology
    • /
    • 제6권5호
    • /
    • pp.437-444
    • /
    • 2005
  • Unburned hydrocarbon (UBHC) emissions from gasoline engines remain a primary engineering research and development concern due to stricter emission regulations. Gasoline engines produce more UBHC emissions during cold start and warm-up than during any other stage of operation, because of insufficient fuel-air mixing, particularly in view of the additional fuel enrichment used for early starting. Impingement of fuel droplets on the cylinder wall is a major source of UBHC and a concern for oil dilution. This paper describes an experimental study that was carried out to investigate the distribution and 'footprint' of fuel droplets impinging on the cylinder wall during the intake stroke under engine starting conditions. Injectors having different targeting and atomization characteristics were used in a 4-Valve engine with optical access to the intake port and combustion chamber. The spray and targeting performance were characterized using high-speed visualization and Phase Doppler Interferometry techniques. The fuel droplets impinging on the port, cylinder wall and piston top were characterized using a color imaging technique during simulated engine start-up from room temperature. Highly absorbent filter paper was placed around the circumference of the cylinder liner and on the piston top to collect fuel droplets during the intake strokes. A small amount of colored dye, which dissolves completely in gasoline, was used as the tracer. Color density on the paper, which is correlated with the amount of fuel deposited and its distribution on the cylinder wall, was measured using image analysis. The results show that by comparing the locations of the wetted footprints and their color intensities, the influence of fuel injection and engine conditions can be qualitatively and quantitatively examined. Fast FID measurements of UBHC were also performed on the engine for correlation to the mixture formation results.

CORE THERMAL HYDRAULIC BEHAVIOR DURING THE REFLOOD PHASE OF COLD-LEG LBLOCA EXPERIMENTS USING THE ATLAS TEST FACILITY

  • Cho, Seok;Park, Hyun-Sik;Choi, Ki-Yong;Kang, Kyoung-Ho;Baek, Won-Pil;Kim, Yeon-Sik
    • Nuclear Engineering and Technology
    • /
    • 제41권10호
    • /
    • pp.1263-1274
    • /
    • 2009
  • Several experimental tests to simulate a reflood phase of a cold-leg LBLOCA of the APR1400 have been performed using the ATLAS facility. This paper describes the related experimental results with respect to the thermal-hydraulic behavior in the core and the system-core interactions during the reflood phase of the cold-leg LBLOCA conditions. The present descriptions will be focused on the LB-CL-09, LB-CL-11, LB-CL-14, and LB-CL-15 tests performed using the ATLAS. The LB-CL-09 is an integral effect test with conservative boundary condition; the LB-CL-11 and -14 are integral effect tests with realistic boundary conditions, and the LB-CL-15 is a separated effect test. The objectives of these tests are to investigate the thermal-hydraulic behavior during an entire reflood phase and to provide reliable experimental data for validating the LBLOCA analysis methodology for the APR1400. The initial and boundary conditions were obtained by applying scaling ratios to the MARS simulation results for the LBLOCA scenario of the APR1400. The ECC water flow rate from the safety injection tanks and the decay heat were simulated from the start of the reflood phase. The simulated core power was controlled to be 1.2 times that of the ANS-73 decay heat curve for LB-CL-09 and 1.02 times that of the ANS-79 decay curve for LB-CL-11, -14, and -15. The simulated ECC water flow rate from the high pressure safety injection pump was 0.32 kg/s. The present experimental data showed that the cladding temperature behavior is closely related to the collapsed water level in the core and the downcomer.

연료전지 자동차의 물탱크 해빙과정에 대한 수치해석적 연구 (Numerical Analysis of Melting Process in a Water Tank for Fuel-cell Vehicles)

  • 김학구;정시영;허남건;임태원;박용선
    • 설비공학논문집
    • /
    • 제19권8호
    • /
    • pp.585-592
    • /
    • 2007
  • Good cold start characteristics are essential for satisfactory operation of fuel cell vehicles. In this study, the melting process has been numerically investigated for a water tank used in fuel cell vehicles. The 2-D model of the tank containing ice and plate heaters was assumed and the unsteady melting process of the ice was calculated. The enthalpy method was used for the description of the melting process, and a FVM code was used to solve the problem. The feasibility study compared with other experiment showed that the developed program was able to describe the melting process well. From the numerical analysis carried out for different wall temperatures of the pate heaters, some important design factors could be found such as local overheating and pressurization in the tank.

일정 열유속 조건의 판형 히터에 의한 해빙과정의 수치해석 (Numerical Analysis of the Melting Process of Ice Using Plate Heaters with Constant Heat Flux)

  • 김학구;정시영;허남건;임태원;박용선
    • 설비공학논문집
    • /
    • 제19권6호
    • /
    • pp.434-440
    • /
    • 2007
  • One of the cold start problems of a FCV is the freezing of the water in the water tank when a FCV is not in operation and the surrounding temperature drops below $0^{\circ}C$. The ice in the tank should be melted as quickly as possible for a satisfactory operation of fuel cell vehicles. In this study, the melting process for the constant heat fluxes of the plate heaters was numerically calculated in the 2-D model of the tank and plate heaters. The enthalpy method and FVM code was used for this analysis. The changes of the temperature with heat fluxes and the heat transfer area could be investigated. The energy balance error was found to increase with the heat flux. From this numerical analysis, the proper heat flux value and some important design factors relating local overheating and pressurization of the water tank could be examined.

Design Considerations on the Standby Cooling System for the integrity of the CNS-IPA

  • Choi, Jungwoon;Kim, Young-ki
    • 한국진공학회:학술대회논문집
    • /
    • 한국진공학회 2015년도 제49회 하계 정기학술대회 초록집
    • /
    • pp.104-104
    • /
    • 2015
  • Due to the demand of the cold neutron flux in the neutron science and beam utilization technology, the cold neutron source (CNS) has been constructed and operating in the nuclear research reactor all over the world. The majority of the heat load removal scheme in the CNS is two-phase thermosiphon using the liquid hydrogen as a moderator. The CNS moderates thermal neutrons through a cryogenic moderator, liquid hydrogen, into cold neutrons with the generation of the nuclear heat load. The liquid hydrogen in a moderator cell is evaporated for the removal of the generated heat load from the neutron moderation and flows upward into a heat exchanger, where the hydrogen gas is liquefied by the cryogenic helium gas supplied from a helium refrigeration system. The liquefied hydrogen flows down to the moderator cell. To keep the required liquid hydrogen stable in the moderator cell, the CNS consists of an in-pool assembly (IPA) connected with the hydrogen system to handle the required hydrogen gas, the vacuum system to create the thermal insulation, and the helium refrigeration system to provide the cooling capacity. If one of systems is running out of order, the operating research reactor shall be tripped because the integrity of the CNS-IPA is not secured under the full power operation of the reactor. To prevent unscheduled reactor shutdown during a long time because the research reactor has been operating with the multi-purposes, the introduction of the standby cooling system (STS) can be a solution. In this presentation, the design considerations are considered how to design the STS satisfied with the following objectives: (a) to keep the moderator cell less than 350 K during the full power operation of the reactor under loss of the vacuum, loss of the cooling power, loss of common electrical power, or loss of instrument air cases; (b) to circulate smoothly helium gas in the STS circulation loop; (c) to re-start-up the reactor within 1 hour after its trip to avoid the Xenon build-up because more than certain concentration of Xenon makes that the reactor cannot start-up again; (d) to minimize the possibility of the hydrogen-oxygen reaction in the hydrogen boundary.

  • PDF

연안 수훈력학 모난를 위한 시간진행 및 조화 유한요소모형 특성 (Characteristics of Time Stepping and Harmonic Finite Element Models for Coastal Hydrodynamic Simulation)

  • 서승원
    • 한국해안해양공학회지
    • /
    • 제5권4호
    • /
    • pp.406-413
    • /
    • 1993
  • 수심적분의 2차원 연안수동역학 모형중 시간진행의 방법과 조화해석 방법에 의하여 전개한 유한요소모형을 비교검토하여 각 모형의 특성을 파악하고 오차를 해석하기 위하여 본 연구를 수행 하였는데 이에 이용된 모형은 ADCIRC, STEPM, FUNDY 그리고 TEA이다. 비교방법으로 해석적 해를 구할 수 있는 4분환원의 형상에서 영역내 특정점에 대한 수치해의 변화추이와 전영역에 관하여 해석해와의 정규오차의 비교를 통해 각 특성을 살펴보았다. 그 결과 전반적으로 조화모형이 시간진행모형에 비하여 매우 우수하고 거의 해석적 해와 일치되는 결과를 보이는 반면, 시간진행모형인 STEPM은 조화모형에 비하여 약 7배, ADCIRC는 STEPM에 비하여 5배 가량 정도가 떨어지는 것으로 나타났다. 이렇게 오차에 지대한 영향을 미치는 것은 초기조건으로 설정한 cold start의 영향 때문에 발생되는 phase lag와 비선형항의 영향인 것으로 추론되었다.

  • PDF

간혈관신티그램의 정상성과 간암 및 간농양에서의 변화 (Hepatoscintiangiography of Normal Liver and Its Alteration in Hepatomas and Liver Abscess)

  • 박용휘;정수교
    • 대한핵의학회지
    • /
    • 제20권1호
    • /
    • pp.25-31
    • /
    • 1986
  • This study was performed to establish normal hepatoscintiangiographic(HSA) pattern of hepatic blood flow and to investigate dynamic differential HSA findings of primary and metastatic carcinomas and abscess of the liver. HSA was carried out after intravenous bolus injection of 10 mCi of Tc-99m-phytate by obtaining sequential anterior images of 1-second exposure for 16 seconds. Observations included (1) baseline study of normal hepatic blood flow pattern by correlating with contrast angiogram, (2) time sequence phasing of normal HSA, and (3) analysis of altered patterns in primary and metastatic carcinomas and abscesses of the liver. Materials consisted of 20 normal subjects, 28 primary hepatocellular carcinomas, 16 metastatic carcinomas and 7 liver abscesses. Results were: (1) Normal HSA demonstrated 3 distinct phases of arterialization(AP), of arterial hepatogram(AHP), and of portal venous hepatogram(PVHP). The means of each phase were 5.3, 6.3 and 8.3 seconds, respectively. Portal vein could be seen in all but one of 20 normal subjects. (2) Pattern changes in diseases groups were early start of AP in carcinomas and very early start of AP in abscesses. AP became prolonged in all disease group. (3) Distinction between AHP was sharp in metastasis and abscesses but un sharp in primary hepatoma. Cold area or areas became vascularized in primary hepatoma but not in abscess. Cold areas of metastasis were inhomogeneously vascularized in late AP and throughout AHP and became relatively vascular as PVHP began. The cold area of abscess showed rim enhancement during AH and APH. These differences in HSA pattern were very useful in differential diagnosis of the diseases studied.

  • PDF

연료전지 자동차의 물탱크 해빙과정에 대한 수치해석적 연구 (Numerical analysis of melting process in a water tank for fuel-cell vehicles)

  • 김학구;정시영;허남건;임태원;박용선
    • 대한설비공학회:학술대회논문집
    • /
    • 대한설비공학회 2006년도 하계학술발표대회 논문집
    • /
    • pp.74-79
    • /
    • 2006
  • Good cold start characteristics are essential for satisfactory operation of fuel cell vehicles. In this study, the melting process has been numerically investigated for a water tank frozen in cold weather The 2-D model of the tank containing ice and plate heaters was assumed and the unsteady melting process of the ice was calculated. The enthalpy method was used for the description of the melting process, and a FVM code was used to solve the problem. The feasibility study compared with other experiment showed that the developed program was able to describe the melting process well. From the numerical analysis carried out for different wall temperatures of the pate heaters, some important design factors could be found such as local overheating and pressurization in the tank.

  • PDF