• Title/Summary/Keyword: Cold flow model

Search Result 239, Processing Time 0.023 seconds

Development of a CFD Model to Study Ventilation Efficiency of Mechanically Ventilated Pig House (강제환기식 돈사의 환기 효율성 분석을 위한 CFD 모델 개발)

  • Seo, Il-Hwan;Lee, In-Bok;Hong, Se-Woon;Hwang, Hyun-Seob;Bitog, Jessie Pascul;Yoo, Jae-In;Kwon, Kyung-Suk;Ha, Tae-Hwan;Kim, Hyeon-Tae
    • Journal of The Korean Society of Agricultural Engineers
    • /
    • v.50 no.1
    • /
    • pp.25-37
    • /
    • 2008
  • When livestock facilities in Korea have been changed larger and denser, rearing conditions have been getting worse and the productivity of animal production have been decreased. Especially in the cold season, the minimized ventilation has generally been operated to save energy cost in Korea resulting in very poor environmental condition and high mortality. While the stability, suitability, and uniformity of the rearing condition are the most important for high productivity, the ventilation configuration is the most important to improve the rearing condition seasonally. But, it is so difficult to analyze the internal air flow and the environmental factors by conducting only field experiment because the weather condition is very unpredictable and unstable as well as the structural specification can not be easily changed by the researchers considering cost and labor. Accordingly, an aerodynamic computer simulation was adopted to this study to overcome the weakness of conducting field experiment and study the aerodynamic itself. It has been supposed that the airflow is the main mechanism of heat, mass, and momentum transfers. To make the simulation model accurately and actually, simplified pig models were also developed. The accuracy of the CFD simulation model was enhanced by 4.4 % of errors compared with the data collected from field experiments. In this paper, using the verified CFD model, the CFD computed internal rearing condition of the mechanically ventilated pig house were analyzed quantitatively as well as qualitatively. Later, this developed model will be computed time-dependently to effectively analyze the seasonal ventilation efficiency more practically and extensively with tracer gas decay theory.

A Study on the Effect of Mid Layer on Supersonic 2D Double Shear Layer (초음속 2차원 2단 혼합층에서 중간층의 역할)

  • Kim, Dongmin;Baek, Seungwook
    • Journal of the Korean Society of Propulsion Engineers
    • /
    • v.19 no.1
    • /
    • pp.9-17
    • /
    • 2015
  • The basic flow configuration is composed of a plane, double shear layer where relatively thin mid gas layer is sandwiched between air and fuel stream. The present study describes numerical investigations concerning the combustion enhancement according to a variation of mid layer thickness. In this case, the effect of heat release in turbulent mixing layers is important. For the numerical solution, a fully conservative unsteady $2^{nd}$ order time accurate sub-iteration method and $2^{nd}$ order TVD scheme are used with the finite volume method including k-${\omega}$ SST model. The results consists of three categories; single shear layer consists of fuel and air, inert gas sandwiched between fuel and air, cold fuel gas sandwiched between fuel and air. The numerical calculations has been carried out in case of 1, 2, 4 mm of mid layer thickness. The height of total gas stream is 4 cm. The combustion region is broadened in case of inert gas layer of 2, 4 mm thickness and cold fuel layer of 4 mm thickness compared with single shear layer.

Cold Test and Internal Flow Analysis of Semi-Freejet Type High Altitude Environment Simulation Test Facility for the High-Speed Vehicle (초고속 비행체를 위한 준 자유흐름식 고공환경 모사시험설비의 상온시험 및 내부유동 해석)

  • Lee, Seongmin;Yu, Isang;Choi, Jiseon;Oh, Junghwa;Shin, Minkyu;Ko, Youngsung
    • Journal of the Korean Society for Aeronautical & Space Sciences
    • /
    • v.46 no.4
    • /
    • pp.290-296
    • /
    • 2018
  • In this study, the cold test and the numerical analysis were carried out according to the shape parameters of the test model in order to confirm the operation range of high altitude environment simulation test facility for the supersonic vehicle. The blockage ratio, angle and length ratio were considered as the design parameters. The blockage rate is expected to be limited in the region of more than 40% due to the normal shock and expansion fan. It was confirmed that the angle of model should be selected at the size of 45 degrees or less due to the influence of the strong shock wave. There was no difference in performance between the lengths of 8 times the model diameter. Finally, we obtained the performance database according to the shape parameters of the conical test model and confirmed the operable range of the semi-freejet type high altitude environment simulation test facility.

Application of QUAL2E Model to Water Quality Prediction of the Nam river (남강의 수질예측을 위한 QUAL2E 모델 적용)

  • Choi, Hyoung-Sub;Park, Tae-Ju;Heo, Jong-Soo
    • Korean Journal of Environmental Agriculture
    • /
    • v.14 no.1
    • /
    • pp.7-14
    • /
    • 1995
  • This research was conducted to apply the QUAL2E model to be adopted to the Nam river under current water quality conditions. The survey area of total 60 Km was divided into five reaches. Each reach was then subdivided into the uniform computational elements of 1.5 Km. Based on the stream characteristics, nine sampling stations consisting of six at main streams and three at tributaries were selected. The field data were obtained from the selected stations twice during October of 1991 and May of 1992, which represented the cold weather and low flow, also the warm weather and low flow conditions, respectively. As the results of sensitivity analysis of the model, the important parameters were the rates of BOD decay, Org-N oxidation, $NH_3-N$ oxidation, Org-P decay. The calibrated and verified results by QUAL2E model were correlation coefficient of $0.45{\sim}0.94$. The results displayed a good agreement between the variables of the field measurements and the model simulations, indicating a potential use of the QUAL2E model for the water quality assessment in the Nam River.

  • PDF

Development of Magnesium Seat Frames using the Vacuum Die Casting Process (진공 다이캐스팅 공정을 이용한 마그네슘 합금 시트프레임의 개발)

  • Shin, Hyun-Woo;Han, Beom-Suk;Yoo, Hyung-Jo;Jung, Hyun-Ho
    • Journal of the Korean Society for Precision Engineering
    • /
    • v.26 no.3
    • /
    • pp.88-97
    • /
    • 2009
  • The vacuum die casting techniques can diminish the porosity of products and provide better surface appearance by the ordinary high pressure die casting process. The vacuum system can also reduce the cold laps in the die casting process and minimize the overflow pockets of the die. The vacuum system does not need high pressures to die cast compared to the ordinary die casting process, and so enables die casting of large parts for a given machine size. Parts made by the vacuum system have higher strength and more elongation than parts made by the ordinary die casting systems. In this paper, we designed and produced the Magnesium seat frames using the vacuum die casting processes. The new Magnesium seat frame was designed to satisfy safety regulations. Some safety test procedures of the seat frame were simulated by the finite element method. We obtained 10% weight reduction by design modification of seat frames compared to the current model. Flow simulations were carried out to minimize the trial and error in producing the parts. The die casted parts using vacuum systems resulted in better mechanical characteristics and no defects compared to those without vacuum systems.

A Bonding Surface Behavior of Bi-metal Bar through Hydrostatic Extrusion (이중복합봉 정수압 압출시 접합면 거동에 관한 연구)

  • Park, Hun-Jae;Na, Gyeong-Hwan;Jo, Nam-Seon;Lee, Yong-Sin
    • Transactions of Materials Processing
    • /
    • v.7 no.1
    • /
    • pp.66-71
    • /
    • 1998
  • The present study is concerned with the hydrostatic extrusion process of copper-clad aluminium bar to investigate the bonding conditions as well as the basic flow characteristics. Considering the bonding mechanism of bi-metal contact surface as cold pressure welding the normal pressure and the contact surface expansion are selected as process parameters governing the bonding conditions, in this study the critical normal pressure required for the local extrusion-the protrusion of virgin surfaces by the surface expansion at the interface-is obtained using a slip line method and is then used as a criteron for the bonding. A rigid plastic finite element method is used to analyze the steady state extrusion process. The interface profile of bi-metal rod is predicted by tracking the paths of two particles adja-process. The interface profile of bi-metal rod is predicted by tracking the paths of two particles adja-cent to interface surface. The contact surface area ration and the normal pressure along the interface are calculated and compared to the critical normal pressure to check bonding. It is found that the model predictions are generally in good agreement with the experimental observations. The compar-isons of the extrusion pressure and interface profile by the finite element with those by experi-ments are also given.

  • PDF

An experimental study on the myocardial protection effect of the steroid mixed cardioplegic solution (Steroid를 첨가한 Cardioplegic solution의 심근보호효과에 관한 실험적 연구)

  • 유시원
    • Journal of Chest Surgery
    • /
    • v.17 no.4
    • /
    • pp.565-573
    • /
    • 1984
  • The increasing use of cardioplegic solution for the reduction of ischemic tissue injury requires that all cardioplegic solution be carefully assessed for any protective or damaging properties. This study describes functional assessment of the efficiency of steroid in cardioplegic solution by using a Langendorffs perfusion model. Isolated rat heart were subject to a 2 minute period of coronary infusion with the steroid mixed cold cardioplegic solution immediately before and also at the midpoint of a 60 minutes period of hypothermic [10\ulcorner\ulcorner] ischemic arrest. The result of this study were as follows: 1.Spontaneous heart beat after ischemic arrest occurred 14 second later Langendorffs reperfusion in the steroid mixed Young & GIK group and 16 second later in the control group. [Young & GIK without steroid] A good recovery state of spontaneous heart beat was shown in both groups. 2.The percentage of recoveries of heart rate during the 30 minute after postischemic Langendorffs reperfusion was; at first 5 minute 106.3\ulcorner.7% [P<0.05] in the steroid mixed Young & GIK group. This percentage of recovery of steroid mixed Young & GIK group was significantly greater than the control group during the first 5 minute course. 3.The percentage of recovery of coronary flow during the 30 minute after postischemic Langendorffs reperfusion was; at first 5 minute 101\ulcorner.2% in the steroid mixed Young & GI K group. This percentage of recovery of the steroid mixed Young & GIK group was not significantly than the control group during the first 5 minute.

  • PDF

Study for Design and Performance Characteristics of Small Bipropellant Thruster using $H_2O_2$/Kerosene (과산화수소/케로신 소형 이원추진제 추력기의 설계 및 성능특성에 관한 연구)

  • Kim, Jung-Hoon;Lee, Jae-Won;Jeon, Young-Jin;Chae, Byoung-Chan;Jeon, Jun-Su;Kim, Yoo;Kim, Sun-Jin
    • Proceedings of the Korean Society of Propulsion Engineers Conference
    • /
    • 2009.05a
    • /
    • pp.41-45
    • /
    • 2009
  • The small-sized bi-propellant thruster using a high concentrated hydrogen peroxide and kerosene as the oxidizer and fuel was designed and fabricated in this study. The water cold-flow test was performed to verify the performance characteristics of the injector. The mixing head assembly used in this model thruster was designed as a structure to combine igniter, injectors and film cooling, which are capable of regulating each mass flowrate. This maximize the experimental verification and efficiency of the design optimization. Finally, the mass flowrate and spray pattern of injector were evaluated by the hydraulic test. Therefore, the design validity of the mixing head was verified.

  • PDF

Stress Analysis of Gas-Gas Heater in Thermal Power Plant (화력발전용 가스재열기의 응력 해석)

  • Hwang, Suk-Hwan;Choi, Jae-Seung;Lee, Hoo-Gwang
    • Journal of the Korean Society for Precision Engineering
    • /
    • v.19 no.1
    • /
    • pp.204-211
    • /
    • 2002
  • Today\`s industrialized plants are required to reduce SOx emitted from stacks at factories, utility power stations, etc. For this purpose, flue gas desulfurization(FGD) system is installed in thermal power plant and gas-gas heater(GGH) is used to play a vital role to reheat the wet treated gas from FGD. The sector plates are located at cold and hot sides of gas-gas heater. They serve as sealing to prevent mixing treated and untreated gases. Therefore, the deformation of the sector plate due to its dead weight and gas pressure should be considered as major factor for the sector plate design. And finite element analysis(FEA) for rotor part in GGH is performed with original model and two weight-reduced models with different diaphragm thickness, respectively. Stress concentrations at rotor diaphragm happen due to the dead weight, pressure difference between treated and untreated gas, and thermal distribution in the rotor. As the thickness of diaphragm is decreased, the stress level is increased. The direction of treated gas and untreated gas flow may affect the stress level.

A Numerical Study of Natural Convection in a Square Enclosure with two Hot Circular Cylinders (두 개의 뜨거운 원형 실린더가 존재하는 사각형 실린더 내부의 자연대류에 관한 수치적 연구)

  • Park, Seong-Hyun;Park, Yong-Gap;Ha, Man-Yeong;Yoon, Hyun-Sik;Son, Chang-Min
    • Korean Journal of Air-Conditioning and Refrigeration Engineering
    • /
    • v.24 no.3
    • /
    • pp.247-255
    • /
    • 2012
  • Numerical calculations are carried out for the natural convection in a square enclosure with two hot cylinders induced by temperature difference between a cold outer rectangular cylinder and two hot circular cylinders. A two-dimensional solution for unsteady natural convection is obtained, using the immersed boundary method (IBM) to model two inner circular cylinders based on finite volume method, for different Rayleigh numbers varying over the range of $10^3$ to $10^5$. The study goes further to investigate the effect of the location of two cylinders on the heat transfer and fluid flow. The location of inner circular cylinders is changed vertically along the center-line of square enclosure. The changes of heat transfer quantities have been presented.