• Title/Summary/Keyword: Cold Working

Search Result 325, Processing Time 0.03 seconds

A Study on the Yin-Yang Characteristics of Bland Taste (담미(淡味)의 음양(陰陽) 특성에 대한 고찰(考察))

  • Ahn, Jinhee
    • Journal of Korean Medical classics
    • /
    • v.35 no.2
    • /
    • pp.121-141
    • /
    • 2022
  • Objectives : This paper aims to examine the Yin-Yang characteristics of bland taste. Methods : Medicinals including bland taste were searched in herbology textbooks and mainly in the Bencaogangmu, of which major discourses were analyzed to examine the Yin-Yang characteristics of bland taste. Results & Conclusions : Most medicinals with bland taste were sweet-bland-cold, holding properties of cooling heat, stimulating urination and detoxification. These properties could be explained in relation to the Triple Burner's metabolism of Qi and fluids, as they stimulate perspiration and urination, improving the flow of fluids which in turn supports production of Original Qi, by working on the TB's Qi circulation system. In the bland taste discourse, it was understood that bland taste moves the Qi system and produces fluids, by first ascending then descending. Zhudanxi and the Neijing have opposing views on whether bland taste is Yin or Yang, but both saw blandness to have both Yin and Yang qualities. Characteristics of the bland taste could be better understood in relation to the Triple Burner. The phrase 'bland is attached to sweet taste[淡附于甘]' refers to the likeliness between the two tastes in that bland taste has the Central Earth qualities, integrating others and concealing itself in its blandness, its taste unspecific, mild and unstimulating thus communicating the Qi within the entire Triple Burner from Upper to Middle to Lower, as does sweet taste.

Athermalization and Narcissus Analysis of Mid-IR Dual-FOV IR Optics (이중 시야 중적외선 광학계 비열화·나르시서스 분석)

  • Jeong, Do Hwan;Lee, Jun Ho;Jeong, Ho;Ok, Chang Min;Park, Hyun-Woo
    • Korean Journal of Optics and Photonics
    • /
    • v.29 no.3
    • /
    • pp.110-118
    • /
    • 2018
  • We have designed a mid-infrared optical system for an airborne electro-optical targeting system. The mid-IR optical system is a dual-field-of-view (FOV) optics for an airborne electro-optical targeting system. The optics consists of a beam-reducer, a zoom lens group, a relay lens group, a cold stop conjugation optics, and an IR detector. The IR detector is an f/5.3 cooled detector with a resolution of $1280{\times}1024$ square pixels, with a pixel size of $15{\times}15{\mu}m$. The optics provides two stepwise FOVs ($1.50^{\circ}{\times}1.20^{\circ}$ and $5.40^{\circ}{\times}4.23^{\circ}$) by the insertion of two lenses into the zoom lens group. The IR optical system was designed in such a way that the working f-number (f/5.3) of the cold stop internally provided by the IR detector is maintained over the entire FOV when changing the zoom. We performed two analyses to investigate thermal effects on the image quality: athermalization analysis and Narcissus analysis. Athermalization analysis investigated the image focus shift and residual high-order wavefront aberrations as the working temperature changes from $-55^{\circ}C$ to $50^{\circ}C$. We first identified the best compensator for the thermal focus drift, using the Zernike polynomial decomposition method. With the selected compensator, the optics was shown to maintain the on-axis MTF at the Nyquist frequency of the detector over 10%, throughout the temperature range. Narcissus analysis investigated the existence of the thermal ghost images of the cold detector formed by the optics itself, which is quantified by the Narcissus Induced Temperature Difference (NITD). The reported design was shown to have an NITD of less than $1.5^{\circ}C$.

An Experimental Study on the Myocardial Protection Effects of the Cardioplegic Solution (Cardioplegic Solution의 심근보호 효과에 관한 실험적 연구)

  • 이종국
    • Journal of Chest Surgery
    • /
    • v.13 no.4
    • /
    • pp.321-337
    • /
    • 1980
  • The increasing use of cardioplegic solution for the reduction of ischemic tissue injury requires that all cardiplegic solution be carefully assessed for any protective or damaging properties. This study describes functional, enzymatic and structural assessment of the efficiency of three cardioplegic solutions (Young & GIK, Bretschneider, and $K^{+}$ Albumin solution) in a Modified Isolated Rat Heart Model of cardiopulmonary bypass and ischemic arrest. Isolated rat heart were subjected to a 2-minute period of coronary infusion with a cold cardioplegic or a noncardioplegic solution immediately before and also at the midpoint of a 60-minute period of hypothermic ($10{\pm}1$. C) ischemic cardiac arrest. The results of this study were as follow: 1. Spontaneous heart beat after ischemic arrest occured 16 seconds later after Langendorff reperfusion in the Young & GIK group (n=6), and 40 second later in the Bretschneider group (n=6) and 6 minute later in the $K^{+}$ Albumin group (n=6), and 16 minute later in the control group (non-cardioplegia). A good recovery state of spontaneous heart beat was shown in the Young & GIK and Bretschneider groups. 2. The percentage of recorveries of heart function at 30 minute after postischemic working heart perfusion were : heart rate $91.6{\pm}3.1$% (P<0.01)m oeaj airtuc oressyre $83{\pm}3$% (P<0.01), coronary flow $70{\pm}8$% (P<0.05) and aortic flow flow rate $39{\pm}9.3$% (P<0.05) in the Young & GIK group. This percentage of recoveries of the Young & GIK group was significantly greater than the control group. In the Bretschneider group, the percentage of recoveries were : heart rate $87.8{\pm}7.5$%(P<0.05), peak aortic pressure $71{\pm}2.3$% (P<0.05) and aortic flow rate $33.2{\pm}6.6$%(P<0.05). hte percentage of recoveries were significantly greater than in the control group. In the $K^{+}$ Albumin group, recoveries of heart function were poor. 3. Total CPK leakage was $131.2{\pm}12.75$IU/30 min/gm. dry weight in the control group, $50.65{\pm}12.75$IU in the Young & GIK gruop, $69.40{\pm}32.21$Iu in Bretschneider group, and $103.65{\pm}15.47$IU in the $K^{+}$ Albumin group during the 30 minute postischemic Langendorff reperfusion. Total CPK leakage was significantly less (P<0.001) in the Young & GIK group, than in the control group. 4. Direct correlatin between percentage recovery of aortic flow rate and total amount of CPK leakage from Myocardium was noticed.(Correlation Coefficient r = 0.76, P<0.001). 5. Mild perivascular edema was the only finding of light microscopic study of myocardium after 60 minute ischemic arrest with cold cardioplegic solutions and hypothermla.

  • PDF

Mechanical Properties and Electrical Conductivities of In-Situ Cu-9Fe-1.2X(X=Ag, Cr, Co) Microcomposite Wires (Cu-9Fe-1.2X (X=Ag, Cr, Co)계 미세복합재료전선의 기계적 특성 및 전기전도도)

  • Song, Jae-Suk;Im, Mun-Su;An, Jang-Ho;Hong, Sun-Ik
    • Korean Journal of Materials Research
    • /
    • v.10 no.1
    • /
    • pp.41-48
    • /
    • 2000
  • In this study, microstructure and mechanical properties and electrical conductivities of in situ Cu-Fe-Xi(Xi=Ag, Cr or Co) alloy wires obtained by cold drawing combined with intermediate heat treatments have investigated. During cold working the primary and secondary dendrite arms are aligned along the drawing direction and elongated into filaments after deformation processing. The addition of Ag was found to be more effective in reducing the microstructural scale at the given draw ratio than that of Co or Cr throughout the drawing processing. The ultimate tensile strength and the conductivity of the Cu-Fe based composites containing Ag were higher than those of Cu-Fe composites containing Co or Cr. The good mechanical and electrical properties of Cu-Fe-Ag wires may be associated with the more uniform distribution of the finer filaments in the wires containing silver. The strength of Cu-Fe-Xi composites is dependent on the spacing of the Fe filaments in accord with a Hall-Petch relationship. The fracture surfaces of all the specimens showed ductile-type fracture and iron filaments occasionally observed on the fracture surfaces.

  • PDF

Design and Performance Evaluation of Low-Temperature Vacuum Blackbody System (저온-진공 흑체시스템의 설계 및 성능 평가)

  • Kim, Ghiseok;Chang, Ki Soo;Lee, Sang-Yong;Kim, Geon-Hee;Kim, Dong-Ik
    • Journal of the Korean Society for Nondestructive Testing
    • /
    • v.33 no.4
    • /
    • pp.336-341
    • /
    • 2013
  • In this paper, the design concept of a low-temperature vacuum blackbody was described, and thermophysical model of the blackbody was numerically evaluated. Also the working performance of low-temperature vacuum blackbody was evaluated using infrared camera system. The blackbody system was constructed to operate under high-vacuum conditions ($2.67{\times}10^{-2}$ Pa) to reduce temperature uncertainty, which is caused by vapor condensation at low temperatures usually below 273 K. In addition, both heat sink and heat shield including cold shield were installed around radiator to prevent heat loss from the blackbody. Simplified mathematical model of blackbody radiator was analyzed using modified Stefan-Boltzmann's rule. The infrared radiant performance of the blackbody was evaluated using infrared camera. Based on the results of measurements, and simulation, temperature stability of the low-temperature vacuum blackbody demonstrated that the blackbody system can serve as a highly stable reference source for the calibration of an infrared optical system.

Classification of Fire Causes in Warehouses Using the TRIZ Technique and Analysis of Preventive Measures Accordingto 4M (TRIZ기법에 의한 물류창고의 화재원인 및 4M에 따른 예방대책 분석)

  • Han, Sang-Hun;Kong, Ha-Sung
    • The Journal of the Convergence on Culture Technology
    • /
    • v.6 no.3
    • /
    • pp.401-412
    • /
    • 2020
  • This study analyzed the causes of warehouse fires using a creative problem-solving technique called TRIZ. It identified preventive measures by applying 4M. The results are as follows. First, this study examined the inconsistency among the causes of warehouse fires using TRIZ. Second, it analyzed human factors and fire prevention measures in warehouses such as safety standards for managers, and methods for the promotion of safety consciousness among workers, and for the reinforcement of construction technology for sandwich panel workers. Third, it identified the mechanical and facility factors and fire prevention measures in warehouses such as safety facilities, the expanded installation of safety devices, the adoption and development of fire suppression equipment, and the deployment of methods to improve the fire resistance of sandwich panels. Fourth, it presented working and environmental factors and fire prevention measures in warehouses such as the tightening of safety precautions and the supervision of working methods, and setting fire partitions both in loading places and based on performance-based design. Finally, it proposed managerial factors and fire prevention measures in warehouses such as specific targeting for firefighting with low fire hazards, reviewing the material quality regulations of non-combustible or higher for sandwich panels in the specific target of firefighting that cannot apply fire safety standards, installing sprinklers in cold storage, and mandating the installation of automated facilities with retroactive application regardless of the floor area in the warehouse with a sandwich panel structure.

Clinical Aspects among Platers (도금공(鍍金工)에 대한 임상적(臨床的) 관찰(觀察))

  • Kim, Doo-Hie
    • Journal of Preventive Medicine and Public Health
    • /
    • v.10 no.1
    • /
    • pp.16-24
    • /
    • 1977
  • This is a result of clinical examination for workers working with Chromic acid and Chromium compounds in the plating room of their companies. I selected two companies that the plating process and the kinds of plating were similar. One (SW Co.) was more or less improved the operating environment with the ventilation machine so on and another (SR Co.) did not it so. The former was examined at March 29th 1977, the latter was at June 28th 1976. But the respiratory communicable diseases, flue or common cold so on were not spreaded there at that time. The clinical aspects were compared between the group of SW, and SR. The swelling and hyperemic signs of nasal mucous membrane and the experience of nasal bleeding were about 50%, generally, in all the groups. The following problem was dizziness or vertigo. The nasal signs in the group of SW (improved ventilation of the room air) were relatively weak, but in another, it was some what severe; - there was necrotic sign with thick nasal clast. They were only used of gauze mask when the vapors of various solvents were deeply full in the room. And there was very high rate of bronchial signs, sputum or coughing in the group of SW improved ventilation so called, than another one. I suppose that it means chronic inflammatory change of the bronchial mucous membrane with deeper signs, due to the individual protectors were carelessly or not used according to the improving of the operating environment. Theses nasal signs mentioned the above were not nearly in the other groups had not been done the Chromium plating. The Status of RBC, Hb and Ht, of urine protein and urobilinogen were mostly in normal range. But the number of WBC was more or less showed with a positive correlation to the working duration.

  • PDF

Basic performance analysis of ocean thermal energy conversion using the refrigerant mixture R32/R152a (R32/R152a 혼합냉매를 적용한 해양온도차발전의 기초성능해석)

  • Cha, Sang Won;Lee, Ho Saeng;Moon, Deok Soo;Kim, Hyeon Ju
    • Journal of Advanced Marine Engineering and Technology
    • /
    • v.38 no.4
    • /
    • pp.502-507
    • /
    • 2014
  • In this paper, performance characteristics of cycles were studied when mixed working fluid was used for ocean thermal energy conversion (OTEC). Among the various mixed refrigerants for industrial heat-pump, R32/R152a used in ocean thermal energy conversion system. For simulations, R32/R152a were used in existing closed cycle and Kalina cycle which is used only ammonia and water as mixed refrigerant. Temperature of the warm heat source was 26 and 29 celsius degree, temperature of the cold heat source was 5 celsius degree. In results of simulation, Gross power of the closed cycle on R32 was 22kW, and efficiency of the cycle was 2.02%. When the mixed refrigerant of R32/R152a, in the ratio of 90 to 10, gross power of the closed cycle was 29.93kW, and efficiency of the cycle was 2.78%. Gross power and cycle efficiency of R32/R152a increased by 36% and 37% than those of existing single refrigerant. Additionally, the same simulations were conducted in Kalina cycle with the same various composition ratio of mixed refrigerant.

Real-Propellant Test of a Turbopump for a 30-Ton Thrust Level of Liquid Rocket Engine (30톤급 액체로켓엔진용 터보펌프 실매질시험)

  • Hong, Soon-Sam;Kim, Dae-Jin;Kim, Jin-Sun;Kim, Jin-Han
    • Journal of the Korean Society of Propulsion Engineers
    • /
    • v.13 no.3
    • /
    • pp.20-26
    • /
    • 2009
  • Turbopump test for a 30-ton-thrust liquid rocket engine was carried out using real-propellant. Liquid oxygen, kerosene, cold hydrogen gas were used for the oxidizer pump, the fuel pump, and the turbine, respectively. The turbopump was reliably operated at the design and off-design conditions and the performance requirements were satisfied, which implies that the turbopump development at the engine subsystem level is successfully accomplished in the point of performance validation. This paper presents the results of a test where the turbopump was run for 75 seconds at three operating modes. In terms of performance characteristics of pumps and turbine, the results of turbopump assembly test using real-propellant showed a good agreement with those of the turbopump component tests using simulant working fluid.

The Influencing Factors forming the Atmosphere of Ward (병실 분위기 조성에 영향을 주는 요인)

  • 윤정인;이미라
    • Journal of Korean Academy of Nursing
    • /
    • v.25 no.4
    • /
    • pp.641-652
    • /
    • 1995
  • Working as nurses, authors found that some patients were not content with their hospital life. Some patients wanted to move to another ward, and others complained about their ward atmosphere. In spite of patients' discomfort, nurses didn't know what made some patients complain about their ward. So, authors tried to find factors that influence atmosphere of hospital wards of the neurosurgery patients. To know the atmosphere of wards, authors selected five neurosurgery ward of a university hospital in Seoul. Observation took a month. An author observed using molar approach, in the morning, in the day time, and in evening time. Authors used concealment /no intervention technique. An author checked condition of people in the wards, and observed their verbal and nonverbal communication behavior their activities and environmental characteristics, and interpreted their meaning through ethnographic research methodology by Spradly. Authors found there was an important factors that influence the atmosphere of ward. It was a human and his attitude. At least one person who was willing to help others made ward atmosphere better. Helping others physically whenever needed, sup-porting the depressed emotionally, offering foods, or talking to others friendly brought good atmosphere. On the contrary, if everyone was indiffernt to others, the atmosphere became cold. Self-centered or selfish behaviors such as occupying too much area, using the toilet too long, covering other's suction bottle without permission and seeing others delicate or urinate were hurtful. In addition to the attitude of patients and their families, unkindness of medical teams including nurses and doctors and tasteless meal caused bad ward atmosphere. Based on this research finding, authors suggest the followings. A For the better atmosphere of ward 1. Nurses should try to make the ward atmosphere better by introducing new patient to older ones. 2. Every ward should have dividing curtains to keep patient's privacy. 3. All hospital personnel should be kind enough to make patients feel that they are repected. 4. Hospital should serve high quality meals to patients. 5. Patients had better stay with those in the similar condition. B. For the future studies 1. Repeated researches are necessary to check reliability of this results. 2. Researches for patients in different area such as ICU, or hemodialysis unit are necessary.

  • PDF