• 제목/요약/키워드: Cold Work

검색결과 507건 처리시간 0.027초

Comparative studies of gasification potential of agro-waste with wood and their characterization

  • Tripathi, Amarmani;Shukla, S.K.
    • Advances in Energy Research
    • /
    • 제3권3호
    • /
    • pp.181-194
    • /
    • 2015
  • In this work, an experimental study of the gasification on wood was carried out in downdraft type fixed bed Gasifier attached with 10 kW duel fuel diesel engine. The main objective of the study was to use wood as the biomass fuel for downdraft Gasifier and to evaluate the operating parameter of gasifier unit to predict its performance in terms of gas yield and cold gas efficiency. The influence of different biomass on fuel consumption rate, gas yield and cold gas efficiency was studied. Composition of producer gas was also detected for measuring the lower heating value of producer gas to select the feed stock so that optimum performance in the existing gasifier unit can be achieved. Under the experimental conditions, Lower heating value, of producer gas, cold gas efficiency and gas yields, using wood as a feed stock, are $4.85MJ/m^3$, 46.57% and $0.519m^3/kg$.

공기분사식 제상장치 개발에 관한 실험적 연구 (Experimental Study for Development of Air Eject Defrost Equipment)

  • 한인근;김창영;김재돌;윤정인
    • 대한기계학회논문집B
    • /
    • 제25권3호
    • /
    • pp.277-284
    • /
    • 2001
  • One of the problems in a refrigerator operation is the frost formation on a cold surface of the evaporator. The frost layer is formed by the sublimation of water vapor when the surface temperature is below the freezing point. This frost layer is usually porous and formed on the cold surface of the evaporator. The frost layer on the surface of a evaporator will make side effect such as thermal resistance. However, these important factors have not been used in determining the defrosting period. Therefore, the proper defrosting operation period based on the new defrosting method is very important, and make a comparison between conventional method like electric defrost and new method in compression work, evaporation pressure, evaporation temperature.

가공된 층상조직의 구상화 속도의 해석 (Analysis of Rate Equation for Spherodization of Cold Rolled Lamellar Pearlite Structure)

  • 위명용
    • 열처리공학회지
    • /
    • 제4권2호
    • /
    • pp.1-8
    • /
    • 1991
  • The spheroidization of cold rolled lamellar pearlite in annealing at the temperatures between 600 and $700^{\circ}C$ has been studied by quantitative micrography. It was foud that the spheroidization proceeded as two stageh. The first stage was the stage of relieving the stored energy by cold work, the second was the stage of reducing the interface energy between ferrite and cementite. The spheroidization rate combining the spheroidization rate of each stages is described by the following equation : $$d(1/S)/dt=k_3{\cdot}D/_{(1/s)}\{{\sigma}V/_{(1/s)}+k_4{\cdot}{\exp}(-bt)\}$$ Where, S is the total area of the interface between ferrite and cementite per unit volume, D is the diffusion coefficient, ${\sigma}$ is the boundary energy, V is the volume fraction of the cementite, and $k_3$, $k_4$, b are constants.

  • PDF

Research on fast cool-down of orifice pulse tube refrigerator by controlling orifice valve opening

  • Kim, Hyo-Bong;Park, Jong-Ho
    • 한국초전도ㆍ저온공학회논문지
    • /
    • 제12권4호
    • /
    • pp.36-40
    • /
    • 2010
  • In this paper, a noble method for rapid cooldown of pulse tube refrigerator (PTR) was proposed and experimentally investigated. An orifice pulse tube refrigerator generates refrigeration effect by expansion PV work at the cold-end, and its amount is affected by the orifice valve opening. There exists the optimum valve opening for maximum cooling capacity and it varies as cold-end temperature. It is verified from simulation results using isothermal model that the optimum valve opening increases as the cold-end temperature increases. In the experiments, a single stage orifice pulse tube refrigerator is fabricated and tested. The fabricated PTR shows 97.5 K of no-load temperature and 10 W at 110 K of cooling capacity with the fixed orifice valve opening. From experiments, the initial cooldown curve with four cases of valve opening control scenario are obtained. And it is experimentally verified that the initial cooldown time can be reduced through the control of orifice valve opening.

알레르기 비염 환자의 비내시경 평가척도와 寒熱 변증과의 상관성 (Relationship between Nasal Endoscopy Index for Pattern Identification and Cold-heat Pattern Identification in Allergic Rhinitis Patients)

  • 안진향;김민희;윤영희;최인화
    • 한방안이비인후피부과학회지
    • /
    • 제28권4호
    • /
    • pp.1-11
    • /
    • 2015
  • Objective : The aim of this study was to suggest guidelines using Nasal endoscopy index for objective pattern identification in allergic rhinitis patients. we performed a clinical study to investigate the relationship between Nasal endoscopy index and Cold-heat pattern identification for allergic rhinitis patients.Methods : We assessed 32 patients with allergic rhinitis using Nasal endoscopy index and the patients filled in Cold-Heat pattern questionnaires. Then, we analyzed the relationship between Nasal endoscopy index and Cold-heat pattern identification.Results : Pale and watery rhinorrhea scores were positively correlated with Cold questionnaire score (P<0.05).Conclusion : The results suggest that pattern identification using nasal endoscopy for allergic rhinitis can be useful for assessing the diagnosis of Cold-heat pattern identification and deciding guidelines of treatment.Acknowledgments : This work was supported by a Grant of the Traditional Korean Medicine R&D Project, Ministry of Health and Welfare, Republic of Korea (HI12C1889 and HI13C0530).

Carbon nanotubes for Field Emission Displays.

  • Milne, W.I.
    • 한국정보디스플레이학회:학술대회논문집
    • /
    • 한국정보디스플레이학회 2004년도 Asia Display / IMID 04
    • /
    • pp.919-922
    • /
    • 2004
  • The Field Emission Display is potentially an excellent display with high brightness and low power consumption with wide viewing angle but more work is still needed in order to identify the ideal electron emitter for such displays. This paper will review the work that we have carried out in Cambridge aver the past couple of years on optimisation of Carbon nanotubes for use as the cold cathode emitters that are possible candidates as the electron sources in second generation FEDs.

  • PDF

Al6082의 가공한계를 고려한 냉간단조 공정설계 (Multistage Cold Forging Process Design of Al6082 Considering Forming Limit)

  • 안규희;강종훈;허수진;신태수;조해용
    • 한국기계가공학회지
    • /
    • 제19권9호
    • /
    • pp.93-99
    • /
    • 2020
  • Recently, as the weight reduction of vehicles has been actively progressed, parts developed using aluminum 60XX series from existing steel materials are increasing. In this paper, the bushing used for the front frame rail, which is one of the parts for fixing engines and other parts in automobiles, was changed to an aluminum material of the Al60XX series, and it was intended to be produced by applying of cold forging method. The bushing is a part that secures the engine frame, and in order to produce it by cold forging, the molding limit is predicted through process design, and a multi-stage process is designed through finite element analysis. In addition, in order to verify the feasibility of the designed forging process, the limits of the multi-step process were verified based on the Cockcroft Latham theory, and the crack and overlap of the actual forging work were predicted and improved.

스테인리스 강판(SUS420)의 냉간단조용 금형개발에 관한 연구 (A Study on the Development of Cold Forging Dies for Stainless Steel Sheet (SUS420))

  • 김엽래;김세환;유헌일
    • 대한기계학회논문집
    • /
    • 제19권3호
    • /
    • pp.877-885
    • /
    • 1995
  • Cold forging die for metal scissor is made by electric discharge machine. The impression of female die is made by electric discharge machine, the heat treatment is applied, and the impression is polished. When we forge goods by using this kind of die, the abrasion is severe and the crack occurs after forging about 240 strokes. Because the die should be frequently produced in the case, the cost rises, the work is delayed, and the precesion of goods is not good. Therefore, the electric discharge machine was not used in this study. Main die was produced by making hob, installing the hob to cold hobbing press, indenting the die material, and cold hobbing the impression. The die life was increased to 5,000-6,000 strokes in this case. In the future study, the die life will be increased to 10,000 strokes by changing the following : (1) the pre-treatment of slug, (2) the structure of die block, (3) the heat treatment of die material

LNG 냉열을 이용하는 암모니아-물 복합 재생 동력 사이클의 성능 특성 (Performance Characteristics of a Combined Regenerative Ammonia-Water Based Power Generation Cycle Using LNG Cold Energy)

  • 김경훈;오재형;정영관
    • 한국수소및신에너지학회논문집
    • /
    • 제24권6호
    • /
    • pp.510-517
    • /
    • 2013
  • The ammonia-water based power generation cycle utilizing liquefied natural gas (LNG) as its heat sink has attracted much attention, since the ammonia-water cycle has many thermodynamic advantages in conversion of low-grade heat source in the form of sensible energy and LNG has a great cold energy. In this paper, we carry out thermodynamic performance analysis of a combined power generation cycle which is consisted of an ammonia-water regenerative Rankine cycle and LNG power generation cycle. LNG is able to condense the ammonia-water mixture at a very low condensing temperature in a heat exchanger, which leads to an increased power output. Based on the thermodynamic models, the effects of the key parameters such as source temperature, ammonia concentration and turbine inlet pressure on the characteristics of system are throughly investigated. The results show that the thermodynamic performance of the ammonia-water power generation cycle can be improved by the LNG cold energy and there exist an optimum ammonia concentration to reach the maximum system net work production.

LNG 냉열을 이용하는 유기랭킨사이클(ORC)의 열역학적 성능 특성 (Thermodynamic Performance Characteristics of Organic Rankine Cycle (ORC) using LNG Cold Energy)

  • 김경훈;하종만;김경천
    • 한국가스학회지
    • /
    • 제18권2호
    • /
    • pp.41-47
    • /
    • 2014
  • 본 논문에서는 유기랭킨사이클과 LNG 사이클로 구성된 복합사이클의 열역학적 성능 해석을 수행한다. 이 복합사이클에서는 현열 형태의 저등급 폐열을 사용하며 LNG 냉열은 열싱크 뿐 아니라 동력 생산에도 사용된다. 시스템의 성능에 대한 터빈입구압력, 응축온도, 열원온도 등 주 파라미터들의 영향을 상세하게 분석한다. 시뮬레이션 결과는 이 복합시스템은 LNG 냉에너지를 사용하지 않은 일반의 ORC에 비해 현저하게 성능이 개선될 수 있음을 보여준다.