• Title/Summary/Keyword: Cold Water Mass

Search Result 198, Processing Time 0.027 seconds

Experimental Study on R-22 Condensation Heat Transfer Characteristic in Plate and Shell Heat Exchanger (Plate and Shell 열교환기 내의 R-22 응축열전달 특성에 관한 실험적 연구)

  • Seo, Mu-Gyo;Park, Jae-Hong;Kim, Yeong-Su
    • Transactions of the Korean Society of Mechanical Engineers B
    • /
    • v.25 no.6
    • /
    • pp.860-867
    • /
    • 2001
  • In this study, condensation heat transfer experiments were conducted with plate and shell heat exchangers(P&SHE) using R-22. An experimental refrigerant loop has been established to measure the condensation heat transfer coefficient of R-22 in a vertical P&SHE. Two vertical counter flow channels were formed in the P&SHE by three plates of geometry with a corrugated trapezoid shape of a chevron angle of 45°. Downflow of the condensing R-22 in one channel releases heat to the cold upflow of water in the other channel. The effect of the refrigerant mass flux, average heat flux, system pressure and vapor quality of R-22 on the measured data were explored in detail. The results indicate that at a higher vapor quality the condensation heat transfer coefficients are significantly higher. A rise in the refrigerant mass flux causes an increase in the h(sub)r. Also, a rise in the average heat flux causes an increase in the h(sub)r. Finally, at a higher system pressure the h(sub)r is found to be slightly lower. Correlation is also provided for the measured heat transfer coefficients in terms of the Nusselt number.

Flow Condensation Heat Transfer Characteristic of R245fa in a Horizontal Plain Tube (수평 평활관내 R245fa의 흐름 응축 열전달 특성)

  • Park, Hyun-Shin;Park, Ki-Jung;Jung, Dong-Soo
    • Korean Journal of Air-Conditioning and Refrigeration Engineering
    • /
    • v.20 no.2
    • /
    • pp.87-96
    • /
    • 2008
  • Flow condensation heat transfer coefficients(HTCs) of R123 and R245fa are measured in a horizontal plain tube. The main test section in the experimental flow loop is made of a plain copper tube of 9.52 mm outside diameter and 530 mm length. The refrigerant is cooled by passing cold water through an annulus surrounding the test section. Tests are performed at a fixed saturation temperature of $50\;{\pm}\;0.2\;^{\circ}C$ with mass fluxes of 50, 100, $150\;kg/m^2s$ and heat flux of $7.3{\sim}7.7\;kW/m^2$. Heat transfer data are obtained in the vapor quality range of $10{\sim}90%$. Test results show that the flow condensation HTCs of R245fa are overall 7.9% higher than those of R123 at all mass fluxes. The pressure drop of R245fa is smaller than that of R123 at the same heat flux. In conclusion, R245fa is a good candidate to replace ozone depleting R123 currently used in chillers from the view point heat transfer and environmental properties.

Performance Analysis of Direct Expansion and Organic Rankine Cycle for a LNG Cold Power Generation System (LNG냉열발전시스템에 있어서 직접팽창 및 유기랭킨사이클의 운전성능평가)

  • Cho, Eun-Bi;Jeong, Moon;Hwang, In-Ju;Kang, Choon-Hyoung
    • Transactions of the KSME C: Technology and Education
    • /
    • v.3 no.1
    • /
    • pp.55-62
    • /
    • 2015
  • The liquefaction to produce LNG (liquefied natural gas) is the only practical way for mass transportation of natural gas across oceans, which accompanies considerable energy consumption in LNG plants. Power generation is one of the effective utilization ways of LNG cold energy which evolves during the vaporization process of LNG with sea water. In this work, performance analysis of two cold energy generation processes, direct expansion and organic Rankine cycles, were carried out by using Aspen HYSYS simulation. The results show that the performance of the organic Rankine cycle is superior to the direct expansion.

Production of All-Female using Sex-Reversal Gynogenetic Diploid in Rainbow Trout, Oncorhynchus mykiss (무지개송어의 자성발생2배체 성전환 수컷을 이용한 전 암컷 생산)

  • Lee, Cheul-Ho;Kim, Dae-Jung;Jeong, Chang-Hwa;Choi, Gyeong-Cheol;Lee, Chae-Sung;Kim, Dong-Soo
    • Journal of Life Science
    • /
    • v.20 no.12
    • /
    • pp.1902-1905
    • /
    • 2010
  • This study was conducted to increase the efficiency of farming practice in rainbow trout, Oncorhynchus mykiss, by sex reversal and chromosome-set manipulation techniques. Induction of sex-reversed gynogenetic diploid rainbow trout males and mass production of all-female rainbow trout by genetic sex reversal was performed. Phenotypic males in the gynogenetic diploid group were induced successfully by dietary administration of 5 mg of 17 alpha-methyltestosterone per kg diet for 82 days. All females were produced by crossing between normal female and sex-reversed gynogenetic diploid male rainbow trout.

Study on Heat Transfer Characteristic of Shell-and-Tube Heat Exchanger with Plate Fin (판형 핀을 가진 원통-다관형 열교환기의 열전달 특성에 관한 연구)

  • Lim, Tae-Woo;Cho, Dong-Hyun
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.10 no.1
    • /
    • pp.46-51
    • /
    • 2009
  • In this work, the experimental investigation was carried out to evaluate the heat transfer performance on the shell side of shell-and-plate finned tube heat exchanger with three different tube numbers(9, 13 and 19). Oil flowing on the shell side was cooled by cold water flowing inside the tubes. A shell-and-tube heat exchanger of an oil cooler consisted of one shell pass and two tube passes with the inner tube diameter of 8.82 mm and the tube length of 575 mm. Mass flow rate was varied from 1.2 to $6.0\;m^3/h$ for oil and from 0.6 to $3.0\;m^3/h$ for cold water, respectively. From the experiment of shell-and-plate finned tube heat exchanger, the overall heat transfer coefficient of heat exchanger with 9 tubes was compared with that of 13 and 19 tubes. It was found that the heat transfer coefficients in shell side of heat exchanger with 9 plate finned tubes showed averagely 1.8 times and 2.3 times higher than those of 13 and 19 tubes, respectively.

A Study on Sasang Constitution Discrimination Using Body Biomarkers - Based on Korean Medicine Cohort Study (신체 생체 지표를 이용한 사상체질 판별 연구 - 한의 코호트 연구를 중심으로)

  • Park, Jeong-Su;Sung, Hyun Kyung;Shin, Seon Mi;Go, Ho-Yeon;Lee, Si-Woo;Baek, Younghwa
    • Journal of Society of Preventive Korean Medicine
    • /
    • v.23 no.3
    • /
    • pp.21-30
    • /
    • 2019
  • Objective : The study aimed to report the results of workplace-based Korean Medicine cohort, The cohort collected the health information including physical measurements, questionnaires, and biomarkers. Method : This study was conducted on 200 faculty members of two hospitals and two universities in 2017 through 2018. The study analyzed physical measurement, cold-heat questionnaire, body compositions and pulse characteristics. Result : The heat-cold score, waist circumference, visceral fat area, and body water were different according to the Sasang constitution, in order of Taeum > Soyang > Soeum. The pulse energy difference was shown only in women. Conclusion : There were differences in body composition such as heat point, waist circumference, internal fat area and body water content by constitution, and also difference by body mass in total energy in pulse examination. It is believed that there were significant relation between physical, physical and energy metabolic aspects through Sasang constitution.

A Loss-of-RHR Event under the Various Plant Configurations in Low Power or Shutdown Conditions

  • Seul, Kwang-Won;Bang, Young-Seok;Lee, Sukho;Kim, Hho-Jung
    • Proceedings of the Korean Nuclear Society Conference
    • /
    • 1997.05a
    • /
    • pp.551-556
    • /
    • 1997
  • A present study addresses a loss-of-RHR event as an initiating event under specific low power or shutdown conditions. Two typical plant configurations, cold leg opening case with water-filled steam generators and pressurizer opening case with emptied steam generators, were evaluated using the RELAP5/ MOD3.2 code. The calculation was compared with the experiment conducted at ROSA-IV/LSTF in Japan. As a result, the code was capable of simulating the system transient behavior following the event. Especially, thermal hydraulic transport processes including non-condensable gas behavior were reasonably predicted with an appropriate time step and CPU time. However, there were some code deficiencies such as too large system mass errors and severe flow oscillations in core region.

  • PDF

Bivalve mollusks in Ulsan Bay (Korea)

  • Lutaenko, Konstantin A.
    • The Korean Journal of Malacology
    • /
    • v.30 no.1
    • /
    • pp.57-77
    • /
    • 2014
  • The bivalve molluscan fauna of Ulsan Bay, East Sea coast of Korea, is summarized, based on original and literature data. The fauna consists of 61 species belonging to 20 families. Seven species are identified only to genus level. Two species (Carditellopsis toneana (Yokoyama, 1922), Carditidae and Fulvia hungerfordi (G.B. Sowerby III, 1901), Cardiidae) are new records for the East Sea coast of Korea, and one species (Crenella decussata (Montagu, 1808), Mytilidae) is a new record for Korea. Biogeographically, Ulsan Bay's bivalve fauna is subtropical with a predominance of tropical-subtropical species, 21 species, or 39% of the total species number, subtropical, 14 species, or 26%, and subtropical-boreal (mostly subtropical-lowboreal), 11 species, 21%, totalling 86%. A remarkable feature of the Ulsan Bay fauna is the presence of tropical-subtropical species not found in Yeongil Bay but common in tidal flats and shallow waters of the Yellow Sea and the southern part of Korea. A cold water mass appearing off the southeast coast of Korea near Ulsan in summer seems responsible for the presence of boreal-arctic species in this area.

The Effect of the Oceanic Condition on Variations of the Catches of Alaska Pollack in the East Sea (the Japan Sea)

  • HONG Chul-hoon;CHO Kyu-Dae
    • Korean Journal of Fisheries and Aquatic Sciences
    • /
    • v.30 no.6
    • /
    • pp.997-1004
    • /
    • 1997
  • The effect of the oceanic condition on variations of the catches of Alaska pollack (Theragra chalcogramma) in the East Sea (the Japan Sea) is examined using monthly catches data of this fish and temperature data during 1972 to 1991. Since 1973 the catches of Alaska pollack have gradually increased, showing a peak in 1981, and then rapidly decreased after 1986. A significant negative correlation was found between variations of the catches and the temperature at 50 m depth offshore Mukho. In 1981, the year of the highest catches in the study period, the water mass in the Eastern Korean Coastal Sea of the East Sea was extremely cold, while the year of poor catch, 1979, was much warmer than the annual mean temperature. The results show that the temperature variations around the Eastern Korean Coastal Sea play an important role in the variations of the catches of Alaska pollack, implying that the effect of the Tsushima Warm Current is also very important.

  • PDF

A Study of mixing characteristics of unlike impinging streams doublet injector (이유체 충돌 분사기의 혼합특성에 관한 연구)

  • Han, Jae-Seob;Kim, Seon-Jin;Kim, Yoo
    • Journal of the Korean Society of Propulsion Engineers
    • /
    • v.4 no.4
    • /
    • pp.36-41
    • /
    • 2000
  • Mixing characteristics of unlike impinging streams double injectors have a great effect on combustion stability and combustion efficiency for liquid rocket engine. In this study a cold test was carried out, using water and TCE as simulants, in order to examine the effect of design parameters such as impingement angle, orifice diameter ratio and momentum ratio on the mass distribution and mixing quality.

  • PDF