• Title/Summary/Keyword: Cold Temperature

Search Result 3,384, Processing Time 0.033 seconds

Automated Cold Volume Calibration of Temperature Variation in Cryogenic Hydrogen Isotope Sorption Isotherm (극저온(20K) 수소동위원소 흡착 등온선의 온도 변화에 대한 자동 저온 부피 교정)

  • Park, Jawoo;Oh, Hyunchul
    • Korean Journal of Materials Research
    • /
    • v.29 no.5
    • /
    • pp.336-341
    • /
    • 2019
  • The gas adsorption isotherm requires accurate measurement for the analysis of porous materials and is used as an index of surface area, pore distribution, and adsorption amount of gas. Basically, adsorption isotherms of porous materials are measured conventionally at 77K and 87K using liquid nitrogen and liquid argon. The cold volume calibration in this conventional method is done simply by splitting a sample cell into two zones (cold and warm volumes) by controlling the level sensor in a Dewar filled with liquid nitrogen or argon. As a result, BET measurement for textural properties is mainly limited to liquefied gases (i.e. $N_2$ or Ar) at atmospheric pressure. In order to independently investigate other gases (e.g. hydrogen isotopes) at cryogenic temperature, a novel temperature control system in the sample cell is required, and consequently cold volume calibration at various temperatures becomes more important. In this study, a cryocooler system is installed in a commercially available BET device to control the sample cell temperature, and the automated cold volume calibration method of temperature variation is introduced. This developed calibration method presents a reliable and reproducible method of cryogenic measurement for hydrogen isotope separation in porous materials, and also provides large flexibility for evaluating various other gases at various temperature.

Analysis of Factors that Can Affect the Assessment of Severity of Cold Hypersensitivity in Hands and Feet (수족냉증 중증도 판단에 영향을 미칠 수 있는 요인 분석)

  • Kim, Jin-Woo;Park, Kyoung-Sun;Lee, Chang-Hoon;Jang, Jun-Bock;Lee, Kyung-Sub;Lee, Jin-Moo
    • The Journal of Korean Obstetrics and Gynecology
    • /
    • v.25 no.4
    • /
    • pp.38-45
    • /
    • 2012
  • Purpose: The purpose of this study is to find the factors that can affect the assessment on severity of cold hypersensitivity on hands and feet by comparing the temperature distribution among the seasons, the scan time and the laboratory temperature. Methods: We compared the temperature distribution of the arms and legs, according to the season and scan time on the basis of the results of Digital Infrared Thermal Imaging(DITI) conducted on 178 women who visited the hospital in summer and winter. We evaluated the correlation between the laboratory temperature and temperature distribution of the arms and legs. Results: The temperature distribution of the arms and legs was significantly different between summer and winter. The temperature distribution of the arms and legs was not significantly different according to the scan time. There was no significant correlation between laboratory temperature and the temperature distribution of the arms and legs in summer and winter. Conclusions: The diagnostic criteria to assess the severity of cold hypersensitivity on hands and feet need to be changed according to the season. The scan time and the small variation($24^{\circ}C{\sim}27^{\circ}C$) of the laboratory temperature doesn't affect the assessment of severity of cold hypersensitivity.

Effects of annealing temperature on strain-induced martensite and mechanical properties of 304 stainless steel (304 스테인리스 강의 가공유기 마르텐사이트와 기계적 거동에 미치는 온도의 영향)

  • Lee, S.H.;Choi, C.Y.;Nam, W.J.
    • Proceedings of the Korean Society for Technology of Plasticity Conference
    • /
    • 2008.10a
    • /
    • pp.203-206
    • /
    • 2008
  • Transformation of austenite to martensite during cold rolling has been widely used to strengthen metastable austenitic stainless steel grades. Aging treatment of cold worked metastable austenitic stainless steels, including ${\alpha}'$-martensite phase, results in the further increase of strength, when aging is performed in $200^{\circ}C$ to $450^{\circ}C$ temperature range. The purpose of the present study was to evaluate the effect of time and temperature on the stress-strain behavior of cold worked austenitic stainless steels. The amount of ${\alpha}'$-martensite during cold working and aging was examined by ferrite scope and X-ray diffraction (XRD). During aging at $450^{\circ}C$ for 1hr, tensile strength dramatically increased by 150MPa. Deformed metastable austenitic steels containing the "body-centered" ${\alpha}'$-martensite are strengthened by the diffusion of interstitial solute atoms during aging at low temperature.

  • PDF

Properties of Strength Development on Cement Mortar Using Agent for Enduring Cold Climate (내한성 혼화제를 이용한 시멘트 모르타르의 강도증진 특성)

  • 홍상희;김현우;심보길;한민철;한천구
    • Proceedings of the Korea Concrete Institute Conference
    • /
    • 2000.10a
    • /
    • pp.571-574
    • /
    • 2000
  • When fresh concrete is exposed to low temperature, the concrete may suffer from the frost damage at early ages and the strength development may be delayed. To solve such problems of cold weather concreting admixtures called agent for enduring cold climate are developed to prevent the fresh concrete from being frozen at early ages. In this study, the experiments are carried out on several kinds of agent for enduring cold climate to present their performance. According to experimental results, most kinds of agent for enduring cold climate show the strength development in the range $-5^{\circ}C$ of curing temperature, it tends to be delayed at long term maturity without agents for enduring cold climate. while it gains high strength maturity when agents for enduring cold climate is applied.

  • PDF

Effects of the partial admission rate and cold flow inlet-outlet ratio on energy separation of Vortex Tube (Vortex Tube의 부분유입율과 저온 입.출구비가 에너지분리 특성에 미치는 영향)

  • 김정수;추홍록;상희선
    • Journal of the Korean Society of Safety
    • /
    • v.13 no.3
    • /
    • pp.51-59
    • /
    • 1998
  • The vortex tube is a simple device for separating a compressed fluid stream into two flows of high and low temperature without any chemical reactions. Recently, vortex tube is widely used to local cooler of industrial equipments and air conditioner for special purpose. The phenomena of energy separation through the vortex tube were investigated to see the effects of cold flow inlet-outlet ratios and partial admission rates on the energy separation experimentally. The experiment was carried out with various cold flow inlet-outlet ratios from 0.28 to 10.56 and partial admission rates from 0.176 to 0.956 by varying input pressure and cold air flow ratio. To find best use in a given cold flow inlet-outlet ratio and partial admission rate, the maximum temperature difference of cold air was presented. The experimental results were indicated that there are an optimum range of cold flow inlet-outlet ratio for each partial admission rate and available partial admission rate.

  • PDF

Strain Ageing Behavior of Cold Worked Zircaloy-4 with Varying Oxygen Content

  • Rheem, K.S.;Park, W.K.
    • Nuclear Engineering and Technology
    • /
    • v.8 no.3
    • /
    • pp.151-157
    • /
    • 1976
  • The strain ageing behavior of cold-worked Zircaloy-4 in vacuum was studied as a function of deformation temperature and oxygen content from 1143 ppm to 3500 ppm 0. Strain ageing occured in the temperature range between 200 and 45$0^{\circ}C$ for the 0 to 10% cold-worked Zircaloy-4, decreasing with increasing amount of cold work. This suppression of strain ageing by cold work is considered to be due to the trapping of oxygen atoms by cold work-produced defects. It has been found that the maximum strain ageing stress in cold-worked Zircaloy-4 is proportional to the square root of oxygen content.

  • PDF

Cold stress test for the diagnosis of cold hypersensitivity on hands (냉부하검사를 통한 수부냉증의 진단)

  • Han, Ji-Young;Joe, Jung-Hoon;Jang, Jun-Bock;Kim, Yong-Suk;Lee, Kyung-Sub
    • Journal of Oriental Medical Thermology
    • /
    • v.2 no.1
    • /
    • pp.17-23
    • /
    • 2003
  • Purpose The cold hypersensitivity is a subjective symptom and it is very difficult to evaluate the severity. It is possible to detect cold hypersensitivity by measuring the skin temperature on DITI, but there is limitation only using DITI to find the objective grade of the symptom. To set a new objective standard for the diagnosis of cold hypersensitivity, we examined the relationship between the Visual Analogue Scale (VAS) score for the cold hypersensitivity and the change of skin temperature on hands by cold stress test Method 23 patients with symptom of cold hypersensitivity were participated as subjects who visited the women medical center of Kangnam Kyunghee Korean Hospital, Kyung Hee Univ. from May 1, 2002 to August 31, 2002. There were all carefully examined to rule out other disease such as obesity, skin diseases, spinal nerve lesions and external wounds. Thermographic observations for this study were made using DITI. We performed cold stress test three times to compare with the results from thermographic observations by DITI: first, after 15 minutes-resting, second, right after 1 minutes soak in $20^{\circ}C$ water, the third for last, 10 minutes after the soak. VAS score was chosen to determine the severity of cold hypersensitivity. Result 1 male and 22 female patients were participated ranging in age from 22.17 to 45.21. There was a significant negative correlation between the recovery rate of finger skin temperature after cold stress test and the VAS score. And there was a significant positive correlation between the difference of finger skin temperature and the back and palm of hands after cold stress test and the VAS score. Conclusion In cold hypersensitivity patients, the cold stress test combined with DITI could be a accurate method for the objective evaluation of cold hypersensitivity, especially good at deciding the severity by numeric values. Using a more strict criterion, as diagnosing of cold hypersensitivity, and longer follow-up may improve the validity of the results attained in clinical trials.

  • PDF

Performance differences of Rhode Island Red, Bashang Long-tail Chicken, and their reciprocal crossbreds under natural cold stress

  • Xie, Shanshan;Yang, Xukai;Gao, Yahui;Jiao, Wenjie;Li, Xinghua;Li, Yajie;Ning, Zhonghua
    • Asian-Australasian Journal of Animal Sciences
    • /
    • v.30 no.10
    • /
    • pp.1507-1514
    • /
    • 2017
  • Objective: The Bashang Long-tail chicken (BS), an indigenous Chinese breed, is considered cold tolerant. We selected BS, the Rhode Island Red (RIR), and their reciprocal crossbreds for the present study. The objectives were: i) to validate whether BS is cold tolerant and whether egg production and cold tolerance of crossbreds could be improved; and ii) to determine the physiological characteristics that underlie cold tolerance and favorable egg production performance in cold environments. Methods: A total of 916 chickens were reared in warm and natural cold environments (daily mean ambient temperature varied from $7.4^{\circ}C$ to $26.5^{\circ}C$ in the warm environment and from $-17.5^{\circ}C$ to $27.0^{\circ}C$ in the cold environment). To investigate their adaptability to the cold environment, the egg production performance and body weight were monitored and compared between breeds and environments. The cloacal temperature and serum biochemical parameters were monitored to reveal the physiological characteristics underlie cold tolerance and favorable egg production performance in the cold environment. Results: The warm environment experiment showed that RIR had the highest egg production performance, and that the reciprocal crossbreds had a higher egg production performance than BS. While in the cold environment RIR had the lowest egg production performance, and the reciprocal crossbreds had a higher egg production performance than BS. In the cold environment BS and reciprocal crossbreds had higher triiodothyronine, tetraiodothyronine levels than RIR. At 35 and 39 wk of age, when the ambient temperature was extremely low (varied from $-20^{\circ}C$ to $0^{\circ}C$), serum glucose, follicle-stimulating hormone, luteinizing hormone, estradiol of BS and crossbreds were higher than RIR. Conclusion: Bashang Long-tail chicken has a favorable cold tolerance ability. Crossbreeding with RIR and BS is an effective way to develop cold tolerant chickens with improved egg production performance.

The Effects of Hot Temperature on Impulsive Behaviors: The Role of Product Types as a Moderator

  • Ahn, Hee-Kyung
    • Asia Marketing Journal
    • /
    • v.14 no.3
    • /
    • pp.27-48
    • /
    • 2012
  • Temperature and weather are all around us, quite literally. Furthermore, temperature and weather not only permeate our atmosphere, constantly affecting our visceral states of warmth and coldness, but they metaphorically permeate our language. People, products, and ideas can all be "hot" or "cold." Given this ubiquity, it is perhaps surprising that relatively little research has systematically examined the influence of temperature on choice and judgment. Temperature-related words such as "hot" and "cold" are often used to describe impulsive and calculated behaviors, respectively. These metaphoric connotations of thermal concepts raise the question as to whether temperature, psychological states and decision making are related to each other, and if so, how. The current research examines these questions and finds support for a relationship. Across one field study and one laboratory experiment, I demonstrate that both hot ambient room temperature (Spa) and hot temperature primes (words) trigger decision outcomes in line with the metaphoric association between hot temperature and impulsivity. In the field study, participants were recruited in hot (40-50 degrees Celsius) and cold (10 degrees Celsius) rooms at a spa. Participants were simply asked to indicate their willingness-to-pay (WTP) for three product categories (travel package, birthday dinner, and cell phone). The results showed that participants in the hot room in comparison to those in the cold room were willing to pay more for the same products. Next, I tested if our results would go beyond ambient temperature and would hold if I were to prime temperature concepts by using a different priming method (i.e., subliminal vs. supraliminal). In line with the previous findings in the spa, participants in the hot priming condition were more likely to choose the wrong answer for the bat and baseball question than those in the cold priming condition. In addition, product type (e.g., pleasure vs. necessity) can moderate the effect of hot temperature on impulsivity. Mood and arousal did not mediate participants' responses. My findings seem to suggest that the effects of temperature on decision outcomes can be attributed to metaphoric associations rather than incidental mood or arousal. The current research applies a novel perspective in understanding the relationship between temperature and judgment and decision making. Also, the results have practical implications for packaging, advertising, merchandising, and pricing of goods and services, as well as for public policy and awareness. One of the most natural implications of my findings would be that retailers would be better off carrying more impulse purchase items on hot days. Furthermore, point-of-purchase promotions encouraging impulse purchase is more likely to be effective in retail environments with higher temperature than with lower temperature. In addition, advertisements and product packages evoking hot temperature associations (e.g., beach, sunshine, summer) might lead consumers to pay higher price for the advertised product than those with cold temperature associations.

  • PDF

Women's Comfort Temperature Range and Dynamic Temperature Change for Maintaining Thermal Comfort in Low Temperature Environment (저온환경에서 여성 온열쾌적성 유지를 위한 쾌적온도범위 및 동적 온도변화 연구)

  • Kim, Soyoung;Lee, Okkyung;Lee, Heeran
    • Fashion & Textile Research Journal
    • /
    • v.22 no.6
    • /
    • pp.853-861
    • /
    • 2020
  • Various types of clothing are being developed to boost thermal comfort during cold winters along with research on change of body temperature when heating is applied. There is a noticeable behavioral difference by gender when using heating panels in a cold environment; however, research on women has been insufficient. This study find a temperature range that provides sustainable thermal comfort in a low temperature environment by observing temperature and change of temperature when subjects are classified according to physical activities or cold sensitivities. For the study results, 8 women in their 20s were subjected to experiment in a low temperature environment for 75 minutes (sitting position: 30 min., running: 15 min., and sitting position: 30 min.). Subjects were asked to turn on/off the heating panel freely to analyze the range of comfortable temperature and clothing microclimate; in addition, skin temperature and heating panel temperature were measured and analyzed at 9 points. As a result, temperature at which subjects turn on and off the heating panel indicated a statistically meaningful difference between the cold sensitivity group depending on exercise or non-exercise. The range of comfortable abdomen temperature was wider than the lower back and was significantly reduced when the subject was running. The range of comfortable temperature was also largest for the heating panel temperature, microclimate, and skin temperature in suggesting that adequate adjustment will be required depending on the surrounding environment or movement of the wearer.