In this study, the admixtures for agents for enduring cold weather used widely are collected and applied to cement mortar to analyze the strength development due to variation of curing temperature at early age. The test results show that anti-freezing admixture have some problems due to high chloride content, which may cause the corrosion of reinforcement embedded in concrete. However, the mortar applied by accelerator and another kind of agent for enduring cold weather produced by S company lead to delay of strength development in low temperature. Also, it is clarified that there are no significant problems for cement mortar in strength development due to low temperature if a suitable kind of agent enduring cold weather is used and cement mortar is cured for more than $7.5^{\circ}D.D$ at early age.
This study was conducted to investigate the thermoregulatory responses and wearing behavior of the cold-sensitive men when exposed to the mild cold of 14$^{\circ}C$. Two sessions of experiment were carried out and five healthy young men for the cold-sensitive group(CSG) and four healthy young for the cold-insensitive group(CIG) participated in the study as subjects CSG maintained rectal temperature lower than CIG due to their thicker clothing resulted in larger decrease of rectal temperature. CSG maintained skin temperatures higher than CIG. CSG felt cooler than CIG but wore thicker clothing for thermal comfort and this made keep their sensation warmer. These results were discussed in terms of autonomic and behavioral temperature regulation.
The purpose of this study was to compare the effects of soup temperature on hunger, energy, and nutrient intake. The hot meal consisted of 400 g of hot beef-vegetable soup (75$^{\circ}C$), Yubu Chobap, Bulgogi, cucumber pickle and radish pickle. The cold meal component were the same as the hot meal except 300 g of water (8$^{\circ}C$) and boiled vegctables (100 g), instead of the hot beef-vegetable soup ot the hot meal. Thirst, core temperature and blood pressure were also measured before and after consumption the test meals in a within-subjects, repeated measures design. 30 women consumed 17% more kilocalories, 13% more protein and lipid and 16% more carbohydrate in the cold meal than in the hot meal. The core temperature at the end of the test meal was higher in the hot meal than in the cold meal. Energy and nutrient intake were inversely correlated with the hunger scores within 1 hour after the hot meal, however those are not related with each other in the cold meal. So hunger feeling might be disturbed in the cold meal. It is concluded that energy and nutrient consumptions were higher in the cold meal, partly because of the distrubed hunger feeling in the cold meal.
Paddy rice is semi-tropical crop and requires warmirrigation water. If mean water temperature at the water source during the growing period is below 18$^{\circ}C$, sime kinds of water warming mechanism should be taken. In this study irrigation water temperature is measured and preventive measures to cold water damage on paddy rice are suggested. Field observations were performed at 100ha field area downtream of the Unmoon reservoir during the growing season of 1997. Land use, canal system, water temperature at irrigation canals. reservoir, and paddy fields were observed. In addition, growth and yield of the rice at selected plots were observed. Accordingly to the record, cold water damage occurred in this area due to the cold irrigation water supply in 1996. It did not occur because of the effective irrigation water management practice in 1997. However, several preventive measures such as pontoon intake system, using existing weir and construting a new warming pond, are suggested to prevent cold water damage in the future. If a new warming pond is construted to raise irrigation water temperature by 2 $^{\circ}C$, a pond area of 2.94 ha is required.
This study of purpose was to evaluate the changes in hands and feet temperature by applying massage and paraffin bath.. The subject of this study was 30 university healthy students. Subjects were divided into paraffin bath group and massages group. The digital infrared thermographic imaging was used for thermographic analysis. The visual analog scale was used for subjective information about the degree of cold sensitivity and cold stress test was used for analyzing the temperature recovery rate. After the interventions showed that temperature difference of the right hand and temperature difference of the left hand are less in the paraffin group than the massage group. When applied paraffin bath and massage to the cold hypersensitivity patient the massage group showed difference in the visual analog scale and the paraffin group showed difference in the temperature of the right hand, left hand, left foot and in the visual analog scale. Paraffin bath treatment seems to be useful to patients with cold hypersensitivity on hands and feet.
Electric vehicle ownership is expanding for two reasons: its technology features have enhanced fuel economy, and the number of vehicle emissions regulations is increasing. Battery performance has a large influence on the capability of electric vehicles, and even though battery thermal management has been actively researched, specific technological improvements to battery performance are not being presented. For instance, many industrial applications utilize vortex tubes as components for refrigeration machines because of their numerous intrinsic benefits. If electric vehicles incorporate vortex tubes for battery cooling, performance and efficiency advancements are possible. This study uses a counter-flow vortex tube to investigate its temperature separation characteristics, based on the back pressure of the cold air exit and the difference between the inlet and back pressures. The experiment uses a vortex tube with the following parameters: six nozzle holes, a 20 mm inner vortex diameter (D), a 14D tube length, a 0.7D cold exit orifice diameter, and a nozzle area ratio of 0.142. The measurements prove that the temperature difference between the hot air and cold air decreased because of the flow resistance of the hot air and the backflow phenomenon at the cold air exit. The flow resistance causes the temperature difference to decrease, and the back pressure of the cold air exit influences the flow resistance. The results show that the back pressure significantly influences the efficiency of temperature separation.
Low temperature ${\delta}$-precipitation phenomenon below 2-step aging ($718^{\circ}C$, $8hr+621^{\circ}C$, 8 hr) temperature of cold drawn Inconel 718 alloy wire was investigated. The investigation was carried out on wires with a cold drawn ratio of 0, 20, 50 and 70% using OM, SEM, XRD, TEM, and DSC. In microstructures of 50 and 70% drawn wire, many precipitates were found along the grain boundaries and the twin boundaries in deformation band. From the results of the XRD and TEM analysis, the precipitates were identified as plate-like ${\delta}$-phase. From the results of the DSC analysis, it was also found that a temperature of ${\delta}$-precipitation decreases with an increase of the cold drawn ratio. We concluded that cold drawing of inconel 718 wire promotes the ${\delta}$-precipitation, and under the condition of a high drawing ratio, the ${\delta}$-phase could be precipitated at a temperature below the aging temperature ($718^{\circ}C$).
We analyzed the effects of regular Jjimjilbang (Korean sauna) exposure on the cold tolerance in young and elderly females. Subjects were young (n=7) and elderly (n=7) females who had never had Jjimjilbang exposure experience. The Jjimjil training group was exposured in the Jjimjilbang 19 times per week. Jjimjibang exposure was limited to three times per day. Jjimjil activity was taken freely. To prove the effects of the cold tolerance, subjects were exposed to cold air ($12{\pm}1^{\circ}C,\;60{\pm}10%$RH). In these conditions, subjects were exposed for 30 minutes at which time rectal temperature, skin temperatures, clothing microclimate, energy expenditure, blood pressure and subjective sensation were measured. To prove the effects of the local cold tolerance, vascular hunting reaction was observed measuring the finger skin temperature while the left middle finger tip was immersed in cold water of $0^{\circ}C$ for 30 minutes. The results are as follows. According to repeated Jjimjil exposure, rectal temperature changes, peripheral temperature and energy expenditure were increased gradually in the cold climate chamber. Blood pressure, subjective sensation and vascular hunting reactions did not show any significant difference. In conclusion, regular Jjimjilbang exposure has negative effects on the ability of the body to improve its regulation of temperature especially in cold tolerance.
Closed-loop J-T (Joule-Thomson) refrigeration cycle is advantageous compared to common open loop $N_2$ decompression system in terms of nitrogen consumption. In this study, two closed-loop pure $N_2$ J-T refrigeration systems with sub-atmospheric device for cooling High Temperature Superconductor (HTS) power cable are investigated. J-T cooling systems include 2-stage compressor, 2-stage precooling cycle, J-T valve and a cold compressor or an auxiliary vacuum pump at the room temperature. The cold compressor and the vacuum pump are installed after the J-T valve to create sub-atmospheric condition. The temperature of 67 K is possible by lowering the pressure up to 24 kPa at the cold part. The optimized hydrocarbon mixed refrigerant (MR) J-T system is applied for precooling stage. The cold head of precooling MR J-T have the temperature from 120 K to 150 K. The various characteristics of cold compressor are invstigated and applied to design parameter of the cold compressor. The Carnot efficiency of cold compressor system is calculated as 16.7% and that of vacuum pump system as 16.4%. The efficiency difference between the cold compressor system and the vacuum pump system is due to difference of enthalpy change at cryogenic temperature, enthalpy change at room temperature and different work load at the pre-cooling cycle. The efficiency of neon-nitrogen MR J-T system is also presented for comparison with the sub-atmospheric devices. These systems have several pros and cons in comparison to typical MR J-T systems such as vacuum line maintainability, system's COP and etc. In this paper, the detailed design of the subcooled $N_2$ J-T systems are examined and some practical issues of the sub-atmospheric devices are discussed.
Objectives: The aim of this study was to find an effective medical device to detect cold sensation of hands. Methods: Patients with cold sensation of hands (N=42) were recruited in July 2013. We surveyed patients’ general characteristics, severity of cold sensation, body temperature in Nogung (PC8) and Hyeopbaek (LU4) measured with a digital thermometer, digital infrared thermal imaging, and pulse wave velocity. Results: The relation between severity of cold sensation and temperature in Nogung (PC8) and Hyeopbaek (LU4) was statistically significant. The results showed a higher correlation of severity of cold sensation with Nogung (PC9) than with Hyeopback (LU4) temperature. No other indices were statistical significant. Conclusions: Measuring the Nogung (PC9) temperature is most reasonable for assessing the severity of cold sensation of hands. To generalize this result, however, a large-scale study is warranted.
본 웹사이트에 게시된 이메일 주소가 전자우편 수집 프로그램이나
그 밖의 기술적 장치를 이용하여 무단으로 수집되는 것을 거부하며,
이를 위반시 정보통신망법에 의해 형사 처벌됨을 유념하시기 바랍니다.
[게시일 2004년 10월 1일]
이용약관
제 1 장 총칙
제 1 조 (목적)
이 이용약관은 KoreaScience 홈페이지(이하 “당 사이트”)에서 제공하는 인터넷 서비스(이하 '서비스')의 가입조건 및 이용에 관한 제반 사항과 기타 필요한 사항을 구체적으로 규정함을 목적으로 합니다.
제 2 조 (용어의 정의)
① "이용자"라 함은 당 사이트에 접속하여 이 약관에 따라 당 사이트가 제공하는 서비스를 받는 회원 및 비회원을
말합니다.
② "회원"이라 함은 서비스를 이용하기 위하여 당 사이트에 개인정보를 제공하여 아이디(ID)와 비밀번호를 부여
받은 자를 말합니다.
③ "회원 아이디(ID)"라 함은 회원의 식별 및 서비스 이용을 위하여 자신이 선정한 문자 및 숫자의 조합을
말합니다.
④ "비밀번호(패스워드)"라 함은 회원이 자신의 비밀보호를 위하여 선정한 문자 및 숫자의 조합을 말합니다.
제 3 조 (이용약관의 효력 및 변경)
① 이 약관은 당 사이트에 게시하거나 기타의 방법으로 회원에게 공지함으로써 효력이 발생합니다.
② 당 사이트는 이 약관을 개정할 경우에 적용일자 및 개정사유를 명시하여 현행 약관과 함께 당 사이트의
초기화면에 그 적용일자 7일 이전부터 적용일자 전일까지 공지합니다. 다만, 회원에게 불리하게 약관내용을
변경하는 경우에는 최소한 30일 이상의 사전 유예기간을 두고 공지합니다. 이 경우 당 사이트는 개정 전
내용과 개정 후 내용을 명확하게 비교하여 이용자가 알기 쉽도록 표시합니다.
제 4 조(약관 외 준칙)
① 이 약관은 당 사이트가 제공하는 서비스에 관한 이용안내와 함께 적용됩니다.
② 이 약관에 명시되지 아니한 사항은 관계법령의 규정이 적용됩니다.
제 2 장 이용계약의 체결
제 5 조 (이용계약의 성립 등)
① 이용계약은 이용고객이 당 사이트가 정한 약관에 「동의합니다」를 선택하고, 당 사이트가 정한
온라인신청양식을 작성하여 서비스 이용을 신청한 후, 당 사이트가 이를 승낙함으로써 성립합니다.
② 제1항의 승낙은 당 사이트가 제공하는 과학기술정보검색, 맞춤정보, 서지정보 등 다른 서비스의 이용승낙을
포함합니다.
제 6 조 (회원가입)
서비스를 이용하고자 하는 고객은 당 사이트에서 정한 회원가입양식에 개인정보를 기재하여 가입을 하여야 합니다.
제 7 조 (개인정보의 보호 및 사용)
당 사이트는 관계법령이 정하는 바에 따라 회원 등록정보를 포함한 회원의 개인정보를 보호하기 위해 노력합니다. 회원 개인정보의 보호 및 사용에 대해서는 관련법령 및 당 사이트의 개인정보 보호정책이 적용됩니다.
제 8 조 (이용 신청의 승낙과 제한)
① 당 사이트는 제6조의 규정에 의한 이용신청고객에 대하여 서비스 이용을 승낙합니다.
② 당 사이트는 아래사항에 해당하는 경우에 대해서 승낙하지 아니 합니다.
- 이용계약 신청서의 내용을 허위로 기재한 경우
- 기타 규정한 제반사항을 위반하며 신청하는 경우
제 9 조 (회원 ID 부여 및 변경 등)
① 당 사이트는 이용고객에 대하여 약관에 정하는 바에 따라 자신이 선정한 회원 ID를 부여합니다.
② 회원 ID는 원칙적으로 변경이 불가하며 부득이한 사유로 인하여 변경 하고자 하는 경우에는 해당 ID를
해지하고 재가입해야 합니다.
③ 기타 회원 개인정보 관리 및 변경 등에 관한 사항은 서비스별 안내에 정하는 바에 의합니다.
제 3 장 계약 당사자의 의무
제 10 조 (KISTI의 의무)
① 당 사이트는 이용고객이 희망한 서비스 제공 개시일에 특별한 사정이 없는 한 서비스를 이용할 수 있도록
하여야 합니다.
② 당 사이트는 개인정보 보호를 위해 보안시스템을 구축하며 개인정보 보호정책을 공시하고 준수합니다.
③ 당 사이트는 회원으로부터 제기되는 의견이나 불만이 정당하다고 객관적으로 인정될 경우에는 적절한 절차를
거쳐 즉시 처리하여야 합니다. 다만, 즉시 처리가 곤란한 경우는 회원에게 그 사유와 처리일정을 통보하여야
합니다.
제 11 조 (회원의 의무)
① 이용자는 회원가입 신청 또는 회원정보 변경 시 실명으로 모든 사항을 사실에 근거하여 작성하여야 하며,
허위 또는 타인의 정보를 등록할 경우 일체의 권리를 주장할 수 없습니다.
② 당 사이트가 관계법령 및 개인정보 보호정책에 의거하여 그 책임을 지는 경우를 제외하고 회원에게 부여된
ID의 비밀번호 관리소홀, 부정사용에 의하여 발생하는 모든 결과에 대한 책임은 회원에게 있습니다.
③ 회원은 당 사이트 및 제 3자의 지적 재산권을 침해해서는 안 됩니다.
제 4 장 서비스의 이용
제 12 조 (서비스 이용 시간)
① 서비스 이용은 당 사이트의 업무상 또는 기술상 특별한 지장이 없는 한 연중무휴, 1일 24시간 운영을
원칙으로 합니다. 단, 당 사이트는 시스템 정기점검, 증설 및 교체를 위해 당 사이트가 정한 날이나 시간에
서비스를 일시 중단할 수 있으며, 예정되어 있는 작업으로 인한 서비스 일시중단은 당 사이트 홈페이지를
통해 사전에 공지합니다.
② 당 사이트는 서비스를 특정범위로 분할하여 각 범위별로 이용가능시간을 별도로 지정할 수 있습니다. 다만
이 경우 그 내용을 공지합니다.
제 13 조 (홈페이지 저작권)
① NDSL에서 제공하는 모든 저작물의 저작권은 원저작자에게 있으며, KISTI는 복제/배포/전송권을 확보하고
있습니다.
② NDSL에서 제공하는 콘텐츠를 상업적 및 기타 영리목적으로 복제/배포/전송할 경우 사전에 KISTI의 허락을
받아야 합니다.
③ NDSL에서 제공하는 콘텐츠를 보도, 비평, 교육, 연구 등을 위하여 정당한 범위 안에서 공정한 관행에
합치되게 인용할 수 있습니다.
④ NDSL에서 제공하는 콘텐츠를 무단 복제, 전송, 배포 기타 저작권법에 위반되는 방법으로 이용할 경우
저작권법 제136조에 따라 5년 이하의 징역 또는 5천만 원 이하의 벌금에 처해질 수 있습니다.
제 14 조 (유료서비스)
① 당 사이트 및 협력기관이 정한 유료서비스(원문복사 등)는 별도로 정해진 바에 따르며, 변경사항은 시행 전에
당 사이트 홈페이지를 통하여 회원에게 공지합니다.
② 유료서비스를 이용하려는 회원은 정해진 요금체계에 따라 요금을 납부해야 합니다.
제 5 장 계약 해지 및 이용 제한
제 15 조 (계약 해지)
회원이 이용계약을 해지하고자 하는 때에는 [가입해지] 메뉴를 이용해 직접 해지해야 합니다.
제 16 조 (서비스 이용제한)
① 당 사이트는 회원이 서비스 이용내용에 있어서 본 약관 제 11조 내용을 위반하거나, 다음 각 호에 해당하는
경우 서비스 이용을 제한할 수 있습니다.
- 2년 이상 서비스를 이용한 적이 없는 경우
- 기타 정상적인 서비스 운영에 방해가 될 경우
② 상기 이용제한 규정에 따라 서비스를 이용하는 회원에게 서비스 이용에 대하여 별도 공지 없이 서비스 이용의
일시정지, 이용계약 해지 할 수 있습니다.
제 17 조 (전자우편주소 수집 금지)
회원은 전자우편주소 추출기 등을 이용하여 전자우편주소를 수집 또는 제3자에게 제공할 수 없습니다.
제 6 장 손해배상 및 기타사항
제 18 조 (손해배상)
당 사이트는 무료로 제공되는 서비스와 관련하여 회원에게 어떠한 손해가 발생하더라도 당 사이트가 고의 또는 과실로 인한 손해발생을 제외하고는 이에 대하여 책임을 부담하지 아니합니다.
제 19 조 (관할 법원)
서비스 이용으로 발생한 분쟁에 대해 소송이 제기되는 경우 민사 소송법상의 관할 법원에 제기합니다.
[부 칙]
1. (시행일) 이 약관은 2016년 9월 5일부터 적용되며, 종전 약관은 본 약관으로 대체되며, 개정된 약관의 적용일 이전 가입자도 개정된 약관의 적용을 받습니다.