• 제목/요약/키워드: Cold Pixel

검색결과 12건 처리시간 0.017초

Application of X-ray Computer Tomography (CT) in Cattle Production

  • Hollo, G.;Szucs, E.;Tozser, J.;Hollo, I.;Repa, I.
    • Asian-Australasian Journal of Animal Sciences
    • /
    • 제20권12호
    • /
    • pp.1901-1908
    • /
    • 2007
  • The aim of this series of experiments was to examine the opportunity for application of X-ray computer tomography (CT) in cattle production. Firstly, tissue composition of M. longissimus dorsi (LD) cuts between the $11-13^{th}$ ribs (in Exp 1. between the $9-11^{th}$ ribs), was determined by CT and correlated with tissue composition of intact half carcasses prior to dissection and tissue separation. Altogether, 207 animals of different breeds and genders were used in the study. In Exp. 2 and 3, samples were taken from LD cuts, dissected and chemical composition of muscle homogenates was analysed by conventional procedures. Correlation coefficients were calculated among slaughter records, tissues in whole carcasses and tissue composition of rib samples. Results indicated that tissue composition of rib samples determined by CT closely correlated with tissue composition results by dissection of whole carcasses. The findings revealed that figures obtained by CT correlate well with the dissection results of entire carcasses (meat, bone, fat). Close three-way coefficients of correlation (r = 0.80-0.97) were calculated among rib eye area, volume of cut, pixel-sum of adipose tissue determined by CT and intramuscular fat or adipose tissue in entire carcasses. Estimation of tissue composition of carcasses using equations including only CT-data as independent variables proved to be less reliable in prediction of lean meat and bone in carcass ($R^2 = 0.51-0.86$) than for fat (($R^2 = 0.83-0.89$). However, when cold half carcass weight was also included in the equation, the coefficient of determination exceeded $R^2 = 0.90$. In Exp. 3 tissue composition of rib samples by CT were compared to the results of EUROP carcass classification. Findings revealed that CT analysis has higher predictive value in estimation of actual tissue composition of cattle carcasses than EUROP carcass classification.

이중 시야 중적외선 광학계 비열화·나르시서스 분석 (Athermalization and Narcissus Analysis of Mid-IR Dual-FOV IR Optics)

  • 정도환;이준호;정호;옥창민;박현우
    • 한국광학회지
    • /
    • 제29권3호
    • /
    • pp.110-118
    • /
    • 2018
  • 항공용 전자 광학 타겟팅 시스템을 위한 중적외선 광학계를 설계하였다. 본 광학계는 이중 시야를 갖도록 설계되었으며, 빔 축소 전단 광학계, 줌 렌즈 그룹, 릴레이 렌즈 그룹, 콜드스탑 공액 광학계 및 냉각 적외선 검출기로 구성된다. 적외선 검출기는 단일 화소의 크기가 $15{\times}15{\mu}m$$1280{\times}1024$ 화소 배열을 가지며 잡음을 최소화하기 위하여, f/5.3의 냉각 콜드스탑이 적용된 제품으로 선정하였다. 이중 시야 ($1.50^{\circ}{\times}1.20^{\circ}$, $5.40^{\circ}{\times}4.23^{\circ}$)는 두 개의 렌즈를 삽입하는 방식으로 구현했으며, 줌 배율 변경 시 모든 시야에 걸쳐 f/5.3의 콜드스탑의 효율을 유지하도록 설계하였다. 열 효과가 이미지에 미치는 영향을 조사하기 위해 비열화 및 나르시서스 분석을 수행하였으며, 비열화 분석은 $-55{\sim}50^{\circ}C$의 작동 온도를 기준으로 초점 이동과 잔여 고차 파면 수차에 조사하였고 제르니케 다항식을 이용한 민감도 분석을 수행하여 최적의 보상자를 선정하였다. 선정된 보상자의 최적 이동을 고려한 MTF 해상력을 확인한 결과, 작동 온도 전 구간에 걸쳐 요구조건인 33 lp/mm에서 축상 10% 이상의 성능을 유지하는 것을 확인하였으며, 나르시서스 분석 결과, NITD (Narcissus Induced Temperature Difference) 값이 $1.5^{\circ}C$ 이하가 되도록 설계 된 것을 확인하였다.