• 제목/요약/키워드: Cold Gas Efficiency

검색결과 121건 처리시간 0.029초

Pilot 규모 2단 형상 가스화기 운전특성 실험 (The operation Characteristic of Pilot-scale 2-Stage Coal gasifier)

  • 홍진표;정재화;서석빈;지준화;이승종;정석우
    • 한국신재생에너지학회:학술대회논문집
    • /
    • 한국신재생에너지학회 2009년도 추계학술대회 논문집
    • /
    • pp.528-532
    • /
    • 2009
  • Integrated Gasification Combined Cycle (IGCC) power plant converts coal to syngas, which is mainly composed with hydrogen and carbon monoxide, by the gasification process and produces electric power by the gas and steam turbine combined cycle power plant. The purpose of this study is to investigate the influence of gasification process to type and structure of gasifier. For this purpose, the performance characteristics of gasification reaction are analyzed with the operation characteristic of pilot-scale 2-stage coal gasifier. It is found that gasification reaction, floating characteristic of melted slag, particle stick of inside of the gasifier, particle stick and deposit of Syngas cooler are the causes in the different performance characteristics.

  • PDF

석탄 합성가스 제조 및 화학원료(DME) 전환설비의 운전 특성 (Operation Characteristics of Coal Syngas Production and DME Conversion Facilities)

  • 정석우;김문현;이승종;윤용승
    • 한국신재생에너지학회:학술대회논문집
    • /
    • 한국신재생에너지학회 2006년도 추계학술대회
    • /
    • pp.83-86
    • /
    • 2006
  • In this study, the syngas producing facility that consists of pulverized coal feeding/gasification and hot gas clean-up system was tested for Indonesian subbituminous coal. And the DME conversion facilities have been developed and tested for converting syngas to DME by reactions with catalysts. So, the entrained-bed slagging type pi lot scale coal gasifier was operated normally in the temperature range of $1,400{\sim}1,450^{\circ}C,\;7{\sim}8kg/cm^2$ pressure. And Roto middle coal produced syngas that has a composition of $36{\sim}38%$ CO, $14{\sim}16%\;H_2,\;and\;5{\sim}8%\;CO_2$. Particulates in syngas were 99.8% removed by metal filters. $H_2S$ composition in syngas was also desulfurized by the Fe chelate system to yield less than 0.1 ppm level. When the clean syngas $70{\sim}100 Nm^3/h$ was provided to DME conversion rector, normally operated in the temperature range of $230{\sim}250^{\circ}C$ and $60kg/cm^2$ pressure, 4.5% DME was yielded.

  • PDF

공급원료에 따른 IGCC 플랜트 운전특성에 대한 전산해석 연구 (The Simulation Study of Operating Characteristics of IGCC Power Plant with Various Feedstock)

  • 심현민;김형택
    • 한국신재생에너지학회:학술대회논문집
    • /
    • 한국신재생에너지학회 2007년도 추계학술대회 논문집
    • /
    • pp.433-436
    • /
    • 2007
  • 가스화기술은 화석연료에 의한 기존의 화력발전기술을 대체할 수 있는 차세대 발전기술로 여겨지고 있어 전 세계적으로 기술개발은 물론 상용 플랜트를 앞 다투어 도입 건설 중에 있다. 현재 국내에서도 2014년까지 실증플랜트 완공에 매진을 가하고 있는 실정이다. 가스화기술은 온실가스인 이산화탄소를 동시에 감축하면서 전력뿐만 아니라 수소, DME, 화학원료와 같은 2차 고급 에너지원을 생산할 수 있다는 장점을 가지고 있다. 이 연구에서는 ASPEN plus를 이용하여 다양한 원료 공급에 따른 300 MW급 IGCC 플랜트에 대한 운전 특성을 알아보고자 하였다. 가스화기에 공급되는 원료는 석탄(역청탄), 중질유(납사, 벙커C유) 등으로 구분해 고려하였으며, 가스화 플랜트 해석모델에 대한 성능을 평가하기 위하여 해외에서 운전 중인 상용 IGCC 플랜트에 대한 운전자료와 상대오차로 비교 산출해 검증하였다. 그 다음으로 가스화(gasification)공정, 산가스 제거(acid gas removal)공정, 복합발전 공정(combined cycle)등과 같은 IGCC 플랜트를 구성하고 있는 각각의 단위공정에 대한 운전 특성에 대한 해석결과를 확인하였다. 해석 결과를 바탕으로 가스화기의 냉가스 효율(cold gas efficiency)과 탄소 전환율(carbon conversion), 산가스 제거공정에 대한 이산화탄소 포획 성능과 복합발전에 따른 플랜트 발전량 및 발전 효율(plant net efficiency)을 예측하였다.

  • PDF

저온 열원 및 LNG 냉열을 이용하는 복합 발전 사이클의 성능 해석 (Performance Analysis of a Combined Power Cycle Utilizing Low-Temperature Heat Source and LNG Cold Energy)

  • 김경훈;오재형;고형종
    • 한국수소및신에너지학회논문집
    • /
    • 제23권4호
    • /
    • pp.382-389
    • /
    • 2012
  • Power generation cycle using ammonia-water mixture as working fluid has attracted much attention because of its ability to efficiently convert low-temperature heat source into useful work. If an ammonia-water power cycle is combined with a power cycle using liquefied natural gas (LNG), the conversion efficiency could be further improved owing to the cold energy of LNG at $-162^{\circ}C$. In this work parametric study is carried out on the thermodynamic performance of a power cycle consisted of an ammonia-water Rankine cycle as an upper cycle and a LNG cycle as a bottom cycle. As a driving energy the combined cycle utilizes a low-temperature heat source in the form of sensible heat. The effects on the system performance of the system parameters such as ammonia concentration ($x_b$), turbine 1 inlet pressure ($P_{H_1}$) and temperature ($T_{H_1}$), and condenser outlet temperature ($T_{L_1}$) are extensively investigated. Calculation results show that thermal efficiency increases with the increase of $P_{H_1}$, $T_{H_1}$ and the decrease of $T_{L_1}$, while its dependence on $x_b$ has a downward convex shape. The changes of net work generation with respect to $P_{H_1}$, $T_{H_1}$, $T_{L_1}$, and $x_b$ are roughly linear.

300MW급 실증 가스화기의 최적 운전조건 및 성능 예측 (The Optimal Operation Condition and Estimation Performance for 300MW Demonstration Gasifier)

  • 유정석;구자형;백민수;이황직
    • 한국신재생에너지학회:학술대회논문집
    • /
    • 한국신재생에너지학회 2008년도 춘계학술대회 논문집
    • /
    • pp.368-371
    • /
    • 2008
  • The optimal operation condition of gasifier is one of the most important parameters to increase efficiency and reliability in IGCC plant. Also the prediction of the syngas composition and quantity must be predicted to carry out process design of the gasification plant. However, the gasifier process licensor are protective with information on process design and optimal gasifier design conditions. So, the most of process studies in the engineering company for gasification plant have carried out to look for key parameters and optimal design conditions using several prediction methods. In this paper, we present the estimated preliminary optimal operation condition of the 300MW Demonstration Entrain Flow Gasifier using Aspen Plus. The gasifier operation temperature considering slag flow was predicted by FactSage software and Annen Model.

  • PDF

탄종별 열분해 생성물의 조성 계산방법 (The Calculation Method of Coal Pyrolysis Products Depending on the Coal Rank)

  • 박호영;서상일
    • 한국수소및신에너지학회논문집
    • /
    • 제21권5호
    • /
    • pp.442-451
    • /
    • 2010
  • This paper describes the calculation method to obtain the product composition of coal pyrolysis at high pressure and high temperature. The products of coal pyrolysis should be determined for the coal gasifier simulation, and this is the first step of the coal gasifier simulation. The pyrolysis product distribution greatly affects the coal gasifier efficiency such as carbon conversion, cold gas efficiency and the syngas composition at the outlet of the gasifier. The present calculation method is based on the coal ultimate/proximate analysis and several correlations among gasifier pressure, coal properties and pyrolysis products. The calculated products for 5 coals have been compared with those from the commercial pyrolysis model.

초임계 이산화탄소를 활용한 발전에 대한 연구 (A Study on the Power Generation Using Supercritical Carbon Dioxide)

  • 노상균
    • 한국수소및신에너지학회논문집
    • /
    • 제30권4호
    • /
    • pp.297-302
    • /
    • 2019
  • In this paper, the power generation efficiency increase has been studied for a Rankine cycle using both supercritical carbon dioxide as a working fluid and LNG as a coolant with PRO/II with PROVISION release 10.0 from Aveva company. Peng-Robinson equation of the state model with Twu's alpha function was selected for the modeling of the power generation cycle using LNG cold heat. Power generation efficiency was increased from 24.82% to 57.76% when using LNG as a coolant for supercritical carbon dioxide power generation cycle.

전극 구조 변화에 따른 Cold Hollow Cathode Ion Source의 특성 변화 (Characterization of Cold Hollow Cathode Ion Source by Modification of Electrode Structure)

  • 석진우;;한성;백영환;고석근;윤기현
    • 한국세라믹학회지
    • /
    • 제40권10호
    • /
    • pp.967-972
    • /
    • 2003
  • 직경 5 cm cold hollow cathode 이온원을 박막의 이온보조증착법 또는 이온보조반응법에 사용하기에 적합한 이온빔으로 넓은 면적을 균일하게 조사할 수 있는 이온원을 설계, 제작하기 위한 방안으로 연구하게 되었다. 이온원은 글로우 방전을 위한 음극과 이온화 효율의 증가를 위한 자석, 플라즈마 챔버, 그리드 전극으로 이루어진 이온광학시스템, 직류전원공급장치로 이루어진다. 전자인출전극의 구조 및 형태로 구분하여 한개의 노즐로 이루어진 (I) 형태와 복수개의 노즐로 변형된 (II) 형태로 제작하였다. 서로 다른 구조의 전자인출전극 (I)형태와 (II) 형태를 부착한 이온원에 beam profile을 측정한 결과 (I) 형태의 전자인출전극을 부착한 경우에는 이온원의 중심에서 140 $\mu\textrm{A}$/$\textrm{cm}^2$으로 측정되어 졌으며, 외곽으로 멀어질수록 급격히 전류밀도가 감소하여 균일한 영역(최대값의 90%)은 직경 5 cm로 측정되어졌다. (II) 형태로 변형되어진 이온원의 경우 중심에서 65 $\mu\textrm{A}$/$\textrm{cm}^2$으로 (I) 형태와 비교하여 상대적으로 낮은 전류밀도가 측정되었지만 외각으로 멀어졌을 경우에도 전류밀도는 완만하게 감소하여 균일한 영역은 직경 20 cm로 측정되었으며, 본 연구목적에 부합되는 특성이 측정되었다. 이온빔 균일도가 증가한 (II) 형태의 전자인출전극을 부착한 이온원으로 주입하는 아르곤 가스량의 변화, 이온광학시스템의 플라즈마 그리드 전극과 가속 그리드 전극 간격의 조절, 이온빔 에너지 변화에 따른 beam profile 및 특성을 괸찰하였다.

LNG선박용 BOG 부분재액화 시스템 특성 연구 (Characteristics of boil-off-gas partial re-liquefaction systems in LNG ships)

  • 윤상국
    • Journal of Advanced Marine Engineering and Technology
    • /
    • 제40권3호
    • /
    • pp.174-179
    • /
    • 2016
  • 해양의 환경오염을 줄이기 위하여 LNG 운송선박, 벙커링 선박 및 LNG를 연료로 추진되는 선박의 건조가 증가하고 있다. 이러한 LNG 선박의 저장탱크들은 외부로부터의 열유입으로 증발가스가 지속적으로 발생하고 있으며, 최근 국내 조선사들은 이 BOG를 재액화하여 회수하는 장치를 개발하여 보급하고 있다. 본 연구에서는 부분재액화 처리장치들의 이론적 최대 재액화 수율을 분석하고 재액화 수율에 미치는 영향 인자들을 비교하였다. 해석결과, BOG와 플래시 가스가 보유한 냉열을 열교환으로 간접 이용하는 부분재액화 처리장치는 최대 48.7%가 되었으며, BOG와 플래시 가스가 혼합 합체되어 냉열이 직접 이용되는 부분재액화 처리장치는 최대 41%로 해석되었다. 또한 액체 수율에 크게 영향을 미치는 인자로는 열교환기의 효율로 열교환기의 성능과 단열이 매우 중요한 것임을 알 수 있다.

2 모듈 스택을 이용한 5kW급 SOFC 시스템 운전결과 (Operation Results of a 5kW-Class SOFC System Composed of 2 Sub-Module Stacks)

  • 이태희;최미화;유영성
    • 한국수소및신에너지학회논문집
    • /
    • 제22권5호
    • /
    • pp.609-615
    • /
    • 2011
  • A 5 kW class SOFC system for cogeneration power units was consisted of a hot box part and cold BOPs. High temperature components such as a stack, a fuel reformer, a catalytic combustor, and heat exchanges are arranged in the bot box considering their operating temperatures for the system efficiency. The hot box was made of ceramic boards for the thermal insulation. A 5 kW class SOFC stack was composed of 2 sub-modules and each module had 64 cells with $15{\times}15cm^2$ area and stainless steel interconnects. The 5 kW class SOFC system was operated with a hydrogen and a city gas. With a hydrogen, the total power of the stacks was about 7.1 kWDC and electrical efficiency was about 49.3% at 80 A. With a city gas, the total power of the stacks was about 5.7 $kW_{DC}$ and electrical efficiency was about 38.8% at 60 A. Under self-sustained operating condition, the system efficiency including a power conditioning loss and a consumed power by BOPs was about 30.2%.