• Title/Summary/Keyword: Cold Gas

검색결과 760건 처리시간 0.026초

가솔린 엔진의 배기 열교환기가 촉매 온도에 미치는 영향에 관한 연구 (Effect of Exhaust Heat Exchanger on Catalytic Converter Temperature in an SI Engine)

  • 이석환;배충식
    • 한국자동차공학회논문집
    • /
    • 제12권2호
    • /
    • pp.9-16
    • /
    • 2004
  • Close-coupled catalyst (CCC) can reduce the engine cold-start emissions by utilizing the energy in the exhaust gas. However, in case the engine is operated at high engine speed and load condition, the catalytic converter may be damaged and eventually deactivated by thermal aging. Excess fuel is sometimes supplied intentionally to lower the exhaust gas temperature avoiding the thermal aging. This sacrifices the fuel economy and exhaust emissions. This paper describes the results of an exhaust heat exchanger to lower the exhaust gas temperature mainly under high load conditions. The heat exchanger was installed between the exhaust manifold and the inlet of close-coupled catalytic converter. The exhaust heat exchanger successfully decreased the exhaust gas temperature, which eliminated the requirement of fuel enrichment under high load conditions. However, the cooling of the exhaust gas through the heat exchanger may cause the deterioration of exhaust emissions at cold start due to the increment of catalyst light-off time.

저온 분사 공정으로 제조된 티타늄 코팅층의 치밀화에 미치는 열처리 분위기의 영향 (Effect of Heat Treatment Environment on the Densification of Cold Sprayed Ti Coating Layer)

  • 유지상;김형준;오익현;이기안
    • 한국분말재료학회지
    • /
    • 제19권2호
    • /
    • pp.110-116
    • /
    • 2012
  • This study investigated the effects of annealing environment for the densification and purification properties of pure titanium coating layer manufactured by cold spraying. The annealing was conducted at $600^{\circ}C$/1 h and three kinds of environments of vacuum, Ar gas, and $5%H_2+Ar$ mixture gas were controlled. Cold sprayed Ti coating layer (as sprayed) represented 6.7% of porosity and 228 HV of hardness, showing elongated particle shapes (severe plastic deformation) perpendicular to injection direction. Regardless of gas environments, all thermally heat treated coating layers consisted of pure ${\alpha}$-Ti and minimal oxide. Vacuum environment during heat treatment represented superior densification properties (3.8% porosity, 156.7 HV) to those of Ar gas (5.3%, 144.5 HV) and $5%H_2+Ar$ mixture gas (5.5%, 153.1 HV). From the results of phase analysis (XRD, EPMA, SEM, EDS), it was found that the vacuum environment during heat treatment could be effective for reducing oxide contents (purification) in the Ti coating layer. The characteristic of microstructural evolution with heat treatment was found to be different at three different gas environments. The controlling method for improving densification and purification in the cold sprayed Ti coating material was also discussed.

페놀 화합물 냉치료와 운동요법의 병행적용이 Carrageenan에 의하여 유발된 근육 통증에 미치는 영향에 관한 연구 (Study on the Effect of Phenol Compound-Cold Therapy plus Exercise Therapy on the Muscle Pain Induced by Carrageenan)

  • 김명섭
    • PNF and Movement
    • /
    • 제7권3호
    • /
    • pp.29-38
    • /
    • 2009
  • Purpose : The aim of this study is to examine the effect of the phenol compound-cold therapy plus exercise therapy on the carrageenan(CAR)-induced muscle pain. Method : Mice were injected 0.1ml of 2% CAR into the gastrocmemius(GAS) muscle for the induction of muscle pain. After 4 hours from the injection of CAR, the cold therapy with 1% syringic acid was done to GAS muscle. After 2 hours from cold therapy, the exercise therapy such as muscle stretching, climing- and declining-movements was performed three times interval of 10 minutes in each experimental group. After 4, 10 and 24 hours from CAR-induced muscle pain, the measurements of muscle diameter, paw withdrawal latency(PWL) and, tail flick latency(TFL) were carried out. Results : In this study, the thickness of GAS muscle in CAR-induced muscle pain significantly increased compared with control. While, the thickness of GAS muscle adopted cold syringic acid-therapy with exercise-therapy group was significantly decreased than that of CAR-induced muscle pain. In the measurements of PWL and TFL, cold syringic acid-therapy with exercise-therapy group was remarkably increased than CAR-induced muscle pain group in PWL and TFL. All measurements were showed significantly different between the treated-group and the treated-time. Conclusions : From these results, it is suggested that the cold syringic acid-therapy with exercise-therapy such as muscle stretching, climing- and declining-movement was effective in the prevention of CAR-induced muscle pain by the decrease of muscle thickness and the increase of PWL and TFL.

  • PDF

가솔린 기관의 냉간시동 조건에서 합성가스 배기분사 기술에 의한 촉매의 활성화 온도 도달시간 단축 및 유해배출물 저감에 관한 연구 (Study on Shortening Light-Off Time of Three Way Catalyst and Reduction of Harmful Emissions with Exhaust Synthetic Gas Injection(ESGI) Technology during Cold Start of SI Engines)

  • 조용석;이성욱;원상연;송춘섭;박영준
    • 한국자동차공학회논문집
    • /
    • 제16권3호
    • /
    • pp.94-101
    • /
    • 2008
  • Since regulations of exhaust emissions are continuously reinforced, studies to reduce harmful emissions during the cold start period of SI engines have been carried out very extensively worldwide. During the cold start period, raising the temperature of cold exhaust gas is a key strategy to minimize the light-off time of three way catalysts. In this study, a synthetic gas containing a large amount of hydrogen was injected into the exhaust manifold to raise the exhaust gas temperature and to reduce harmful emissions. The authors tried to evaluate changes in exhaust gas temperature and harmful emissions through controlling the engine operating parameters such as ignition timings and lambda values. Also the authors investigated both combustion stability and reduction of harmful emissions. Experimental results showed that combustion of the synthetic gas in the exhaust manifold is a very effective way for solving the problems of harmful emissions and light-off time. The results also showed that the strategy of retarded ignition timings and increased air/fuel ratios with ESGI is effective in raising exhaust gas temperature and reducing harmful emissions. Futhermore, the results showed that engine operating parameters ought to be controlled to lambda = 1.2 and ignition timing = $0{\sim}3^{\circ}$ conditions to reduce harmful emissions effectively under stable combustion conditions.

3D 프린팅 공정 관점의 저온분사 기술 (Cold spray technology as a potential additive manufacturing)

  • 김형준;윤상훈
    • 한국표면공학회:학술대회논문집
    • /
    • 한국표면공학회 2017년도 춘계학술대회 논문집
    • /
    • pp.90-90
    • /
    • 2017
  • Cold spray (Cold gas dynamic spray, kinetic spray) is the latest spray coating process that is known as solid state deposition process. In cold spray, inert gases (typically nitrogen and helium) accelerate powder particles prior to impact onto the substrate. Accelerating particles start to deposit onto the substrate after reaching certain critical velocities depending on the coating materials and substrate. Since process gas temperatures are kept below to melting temperature of the coating materials, it is possible to spray temperature sensitive materials such as copper and titanium, nanocrystal materials, and amorphous metals without affecting the phase change and oxide formation. It is also possible to deposit thick coatings because cold spray coatings present compressive residual stresses. This ability to deposit thick coatings is suitable to repair or rebuild parts as an additive manufacturing process. In this presentation, cold spray is introduced and compared to other additive manufacturing processes such as laser and electron beam based processes. It is also presented some applications especially in the view point of additive manufacturing process.

  • PDF

촉매가 장착된 가솔린엔진에서 동기화된 2차공기분사에 의한 배기 탄화수소 저감 (Reducing Exhaust Hydrocarbon at Gasoline Engine with Catalytic Converter using Synchronized Secondary Air Injection)

  • 심현성;민경덕;정석호
    • 한국자동차공학회논문집
    • /
    • 제9권2호
    • /
    • pp.67-74
    • /
    • 2001
  • A synchronized secondaty air injection method has been developed to hydrocarbon emission by injecting secondary air intermittently into exhaust port. The method has been tested in a single cylinder spark-ignition engine operating at cold-steady / cold-start conditions. Effects of air injection timing, intake pressure and engine air-fuel ratio have been investigated at cold-steady condition. Also, hydrocarbon emission and exhaust gas temperature with catalytic conberter are compared with a continuous SAI method and base condition at cold-start condition. Resules show that hydrocarbon reduction rate and exhaust gas temperature are sensitive to the timing of synchronized SAI. At cold-steady condition, HC emission is minimum at engine air-fuel ratio of 10. At cold-start condition, the accumulated hydrocarbon emission during the first 120 s decreases about 56% and 22% with the synchronized and continuous SAI, respectively, compared to that of base condition.

  • PDF

고온 가스질화 된 STS 430 스테인리스강의 냉간 가공성에 미치는 항온변태 열처리 시간 변화의 영향 (Effect of Isothermal Transformation Heat-treatment Time on Cold Workability of STS 430 Stainless Steel after High Temperature Gas Nitriding)

  • 김정민;현양기;송상우;김기동;손영호;성장현
    • 열처리공학회지
    • /
    • 제27권1호
    • /
    • pp.15-22
    • /
    • 2014
  • This study is to investigate the phase changes and cold workability after isothermal transformation at $780^{\circ}C$ by using the high temperature gas nitrided (HTGN) STS 430 ferritic stainless steel specimens. The phase diagram of STS 430 steel obtained by calculation showed that the phase appeared at $1100^{\circ}C$ showed as ${\alpha}+{\gamma}{\rightarrow}{\gamma}{\rightarrow}{\gamma}+Cr_2N{\rightarrow}{\gamma}+Cr_2N+CrN$ with increasing nitrogen concentration. Also, the transformation of ${\gamma}{\rightarrow}Cr_2N$ during heat treatment isothermally at $780^{\circ}C$, nitrogen pearlite with lamellar type was fully formed at the nitrogen permated surface layer for 10 hrs. However, this transformation was not completed for 1 hr, resulting nitrogen pearlite plus martensite. The cold rolled specimen of isothermally transformed at $780^{\circ}C$ for 10 hrs after high temperature gas nitriding decreased the layer thickness of nitrogen pearlite inducing the deformation of hard $Cr_2N$ phase. the dissolution rate of $Cr_2N$ phase increased rapidly with increasing cold rolling ratio. Specimens with the microstructure of nitrogen pearlite (isothermally transformed at $780^{\circ}C$ for 10 hrs) were possible to cold rolling without crack formation. However, the mixed structures of nitrogen pearlite + martensite (isothermally transformed at $780^{\circ}C$ for 1 hr) were impossible to cold deformation without cracking.

초고압 가스차단부의 냉가스 유동해석 (An Analysis of Cold Gas Flow-Field for UHV Class Interrupters)

  • 송기동;박경엽;송원표
    • 대한전기학회논문지:전기기기및에너지변환시스템부문B
    • /
    • 제49권6호
    • /
    • pp.387-394
    • /
    • 2000
  • This paper presents a method of cold gas flow-field analysis within puffer type GCB(Gas Circuit Breaker). Using this method, the entire interruption process including opening operation of GCB can be simulated successfully. In particular, the distortion problem of the grid due to the movement of moving parts can be dealt with by the fixed grid technique. The gas parameters such as temperature, pressure, density, velocity through the entire interruption process can be calculated and visualized. It was confirmed that the time variation of pressure which was calculated from the application of the method to a model GCB agreed with the experimental one. Therefore it is possible to evaluate the small current interruption capability analytically and to design the interrupter which has excellent interruption capability using the proposed method. It is expected that the proposed method can reduce the time and cost for development of GCB very much. It also will be possible to develop the hot-gas flow-field analysis program by combining the cold-gas flow field program with the arc model and to evaluate the large current interruption capability.

  • PDF

냉열을 이용한 LNG 증발기체 BOG 재액화 신공정과 기존공정에 관한 비교연구 (Study on the Comparison of New and Used Reliquefaction System of Boil-Off-Gas by LNG Cold Energy)

  • 이동혁;장창봉;정상용;김정환;이헌석;김범수;고재욱
    • 한국가스학회지
    • /
    • 제14권1호
    • /
    • pp.42-46
    • /
    • 2010
  • LNG (Liquefied Natural Gas)기지의 LNG 저장탱크에서 BOG (Boil Off Gas)가 약 0.5 vol%/day로 자연적으로 생성된다. 이를 회수하기 위해서 기존에는 LNG와 BOG를 1:12의 질량비로 직접 접촉시켜 액화시켰다. 이 공정은 단순하지만 하절기에는 LNG 사용량 저하로 인해 공정운영의 어려움이 있다. 이러한 단점을 보완하기 위해 대안된 LNG 냉열을 사용하는 간접접촉방식을 HYSYS를 이용하여 분석해보고 직접접촉방식과 BOG 재액화 효율비교를 통해 분석하여 유리한 공정을 도출하였다.

Hi-CON/H2 BAF와 HNx BAF의 소둔사이클 제어온도에 관한 연구 (A Study on Annealing Cycle Control Temperature of Hi - CON/2 BAF and HNx BAF)

  • 김문경
    • Journal of Advanced Marine Engineering and Technology
    • /
    • 제18권1호
    • /
    • pp.114-122
    • /
    • 1994
  • A cold temperature control system for the BAF(batch annealing furnace) has been established in order to reduce energy consumption to imrpove productivity and stabilize the properties of products. Therefore we confirmed a relation between annealing cycle time and atmospheric gas, changing annealing cycle time according to BAF temperature with time during heating and actual temperature measurements cold spot during soaking. The results of the temperature variation effect on the batch annealing are as follows. 1) Cooling rate is increasing gradually with increasing atmospheric gas flow, but heating rate is hardly increasing without atmospheric gas component. Heating time is reduced to one half with increasing atmospheric gas flow rate and changing of atmospheric gas component from HNx to Ax gas and annealing cycle time is reduce to 2.7 times. 2) With enlarging the difference between furnace temperature and soaking temperature at the HNx BAF, heating time becomes short, but cooling time is indifferent. 3) If temperature difference of 300.deg. C in the temperature change of cold spot according to the annealing cycle control temperature, Hi-CON/H2BAF is interchanging at each other at 26hours, but HNxBAF at 50 hours. 4) Soaking time at batch annealing cycle determination is made a decision by the input coil width, and soaking time for quality homogenization of 1219 mm width coil must be 2.5 hours longer then that of 914mm width coil for the same coil weight at Hi-CON/H2BAF. But, it is necessary to make 2 hours longer at HNxBAF.

  • PDF