• Title/Summary/Keyword: Cold Energy

Search Result 1,251, Processing Time 0.026 seconds

Effects of N-acetylcysteine on the energy status and antioxidant capacity in heart and liver of cold-stressed broilers

  • Li, Chengcheng;Peng, Meng;Liao, Man;Guo, Shuangshuang;Hou, Yongqing;Ding, Binying;Wu, Tao;Yi, Dan
    • Asian-Australasian Journal of Animal Sciences
    • /
    • 제33권9호
    • /
    • pp.1444-1454
    • /
    • 2020
  • Objective: Cold stress induces oxidative damage and impairs energy status of broilers. N-acetylcysteine (NAC) exhibits antioxidant properties and modulates energy metabolism of animals. This study was conducted to investigate the effects of NAC on energy status and antioxidant capacity of heart and liver in the cold-stressed broilers. Methods: The experiment consisted of 4 treatments in a 2×2 factorial arrangement with two diets (basal diet or plus 0.1% NAC) and two ambient temperatures (thermoneutral [conventional ambient temperature] or cold stress [10℃±1℃ during days 15 to 42]). Results: No ascites were seen in cold-stressed broilers. NAC did not attenuate the impaired growth performance of stressed birds. However, NAC decreased plasma asparagine but increased aspartate levels in cold-stressed birds (p<0.05). NAC reduced hepatic adenosine triphosphate (ATP) but elevated adenosine diphosphate contents in unstressed birds (p<0.05). The hepatic ratio of adenosine monophosphate (AMP) to ATP was increased in birds fed NAC (p<0.05). NAC decreased plasma malondialdehyde (MDA) level and cardiac total superoxide dismutase (T-SOD) activity in unstressed birds, but increased hepatic activities of T-SOD, catalase and glutathione peroxidase in stressed birds (p<0.05). NAC down-regulated hepatic AMP-activated protein kinase but up-regulated cardiac heme-oxigenase mRNA expression in stressed birds, and decreased expression of hepatic peroxisome proliferator-activated receptor coactivator-1α as well as hypoxia-inducible factor-1α in liver and heart of birds. Conclusion: Dietary NAC did not affect energy status but enhanced the hepatic antioxidant capacity by increasing the activities of antioxidant enzymes in cold-stressed broilers.

냉간정수압 하에서 금속분말의 치밀화에 미치는 고무몰드의 영향 (Effect of rubber mold on densification behavior of metal powder during cold isostatic pressing)

  • 정진원;김기태
    • 대한기계학회논문집A
    • /
    • 제22권2호
    • /
    • pp.330-342
    • /
    • 1998
  • The effect of rubber mold on densification behavior of pure iron powder was investigated under cold isostatic pressing. The thickness effect of rubber mold was also studied. The elastoplastic constitutive equation based on the yield function of Shima and Oyane was implemented into the finite element program(ABAQUS) to predict compaction responses of metal powder under cold isostatic pressing. The hyperelastic constitutive equation based on Moony-Rivlin and Ogden strain energy potentials was also employed to analyze deformation of rubber mold. The coefficients of the strain energy potentials were obtained from tension and volumetric compression data of rubber. Finite element results were compared with experimental data for densification of pure iron powder under cold isostatic pressing.

냉시동시 압축착화 조건의 상관관계에 관한 수소 HCCI 기관의 실험적 연구 (An Experimental Study on Correlation of Compression Ignition Condition at Cold Start with Hydrogen HCCI Engine)

  • 이광주;이종구;안병호;이종태
    • 한국수소및신에너지학회논문집
    • /
    • 제23권6호
    • /
    • pp.628-633
    • /
    • 2012
  • It was found that the pure hydrogen-air pre-mixture was self-ignited at a high compression ratio without any assisting method in room temperature, thus refuting the preconception that compression ignition of hydrogen engine was impossible. Therefore, in order to analyze the correlation of compression ignition condition at cold start with hydrogen HCCI engine clearly, the possibility of compression igniting compression ratio is investigated with the change of equivalence ratio and engine speed, experimentally. As the results, it is confirmed that the possibility of compression-igniting compression ratio at cold start was decreased by increasing equivalence ratio due to decreasing auto-ignition temperature. In addition, it is grasped that the possibility of compression-igniting compression ratio at cold start is decreased around 14.9% by increasing engine speed at same supply energy.

초음파센서를 이용한 냉중성자원 수직공 형상측정 (Measurement of the Shape of the Cold Neutron Source Vertical Hole by Ultrasonic Wave Sensor)

  • 박국남;최창웅;심철무
    • 대한기계학회논문집A
    • /
    • 제24권9호
    • /
    • pp.2167-2173
    • /
    • 2000
  • The HANARO (High-flux Advanced Neutron Application Reactor) has operated since 1995. The Cold Neutron(CN) hole was implanted in the reflector tank from the design stage. Before a vacuum chamber and a moderator cell for the cold neutron source are installed into the CN hole, it is necessary to measure the exact size of the inside diameter and thickness of the CN hole to prevent the interference problem. Due to inaccessibility and high radiation field in the CN hole, a mechanical measurement method is not permitted. The immersion ultrasonic technique is considered as the best method to measure the thickness and the diameter. The 4 axis manipulator of the 2 channel of a sensor module was fabricated. The transducer of 10 MHz results in 0.03 nun of resolution. The inside diameter and thickness for 550 points of the CN hole were measured using 2 channel ultrasonic sensors. The results showed that the thickness is in the range of 13-6.7 mm and inside diameter is in the range of o 156-165. These data will be a good reference in the design of a cold neutron source facility.

열전소자가 적용된 냉·온수 매트용 전열 모듈의 기초 열설계에 관한 수치해석적 연구 (Numerical Analysis on the Thermal Design of a Heat Exchanger for a Cold & Hot Water Mattress Equipped with Thermoelectric Modules)

  • 양호동;박설현
    • 한국기계가공학회지
    • /
    • 제20권3호
    • /
    • pp.113-121
    • /
    • 2021
  • In this study, the thermal characteristics of cold and hot water mattress units equipped with thermoelectric modules were investigated via numerical analyses. Cold and hot water mattress products that are currently in existence use manual methods requiring refrigerants to be added to the hot water boiler. However, the cold and hot water mattress units using thermoelectric modules can provide improved efficiency via energy savings and actively resolving environmental pollution problems. To determine the efficiency of the thermoelectric module, the mattress was modeled and its efficiency was analyzed for the cooling and heating processes using two 100-W-class and one 200-W-class thermoelectric modules, respectively. From the results of this study, it was confirmed that when two 100-W-class modules were used, the application area was larger than when a single 200-W-class module was used, with uniform temperature distribution and improved performance compared to existing products in terms of electrical energy.

LNG 인수기지용 냉열발전 시스템 비교 연구 (A Comparative Study of the Cold Power Generation Systems for LNG Terminal)

  • 김동수;박영무
    • 에너지공학
    • /
    • 제5권1호
    • /
    • pp.34-41
    • /
    • 1996
  • LNG의 기화열(냉열)은 NG액화시 소모된 동력으로서 생산된 NG의 약 14%에 달한다. 평택 인수기지의 경우 '93도입물량 기준으로 냉열량은 96MW에 달한다. 냉열을 이용하여 전력을 생산하는 방안으로, 저온 엑서지를 활용하는 Rankine 사이클, 압력 엑서지를 이용한 부분직접 팽창 사이클 및 이 두 사이클의 혼합 사이클인 Linde공정 냉열발전시스템의 성능을 비교연구하였다. 시뮤레이션은 ASPEN Plus를 이용하여 수행하였으며 현재 인수기지에서 운영되고 있는 각종 설비들의 설계데이타를 이용하였다. 시스템별 출력은 약 3∼6MW였으며 최적운전조건의 엑서지 효율은 37%로 계산되었다. 또한 부분직접팽창방식의 최적 시스템을 제시하였고 열교환기의 총 면적이 동일 할 경우 부분직접팽창과 랭킨사이클의 성능은 비슷한 것으로 확인되었다.

  • PDF

ZrO$_2$를 이용한 증기폭발 실험 (Steam Explosion Experiments using ZrO$_2$)

  • 송진호;김희동;홍성완;박익규;신용승;민병태;김종환;장영조
    • 대한기계학회논문집B
    • /
    • 제25권12호
    • /
    • pp.1887-1897
    • /
    • 2001
  • Korea Atomic Energy Research Institute (KAERI) launched an intermediate scale steam explosion experiment named "Test for Real Corium Interaction with water (TROI)" using reactor material to investigate whether the molten reactor material would lead to energetic steam explosion when interacted wish cold water at low pressure. The melt-water interaction experiment is performed in a pressure vessel with the multi-dimensional fuel and water pool geometry. The novel concept of cold crucible technology, where powder of the reactor material in a water-cooled cafe is heated by high frequency induction, is firstly implemented for the generation of molten fuel. In this paper, the lest facility and cold crucible technology are introduced and the results or the first series of tests were discussed. The 5 kg of molten ZrO$_2$jet was poured into the 67cm deep water pool at 30 ∼ 95 $\^{C}$. Either spontaneous steam explosions or quenching was observed. The morphology of debris and pressure wave profiles clearly indicate the differences between the two cases.

INVESTIGATION OF THE CNS HOLE SHAPE AND A PROPOSED INSTALLATION METHOD FOR A VACUUM CHAMBER FOR THE HANARO REACTOR

  • Cho Yeong-Garp;Kim Young-Ki;Lee Kye-Hong;Choung Yun-Hang
    • Nuclear Engineering and Technology
    • /
    • 제38권5호
    • /
    • pp.455-458
    • /
    • 2006
  • The HANARO reactor has a vertical hole for a cold neutron source (CNS) in the heavy-water reflector tank, i.e., the CNS hole, which was considerably deformed during its welding to the horizontal cold neutron (CN) beam tube. This paper presents an investigation of the form of the CNS hole for the optimal design of the a vacuum chamber for the CNS. In addition, the installation method of the vacuum chamber into the CNS hole for minimizing the water thickness between the vacuum chamber and the nose of the CN beam tube is proposed.

보텍스튜브 성능향상을 위한 유입노즐 조건에 관한 연구 (Inflow Nozzle Conditions for Improving Vortex Tube Performance)

  • 최훈기;유근종;임윤승
    • 한국기계가공학회지
    • /
    • 제17권2호
    • /
    • pp.68-76
    • /
    • 2018
  • A vortex tube is a simple energy separating device that splits a compressed air stream into a cold and hot stream without any external energy supply or chemical reactions. The efforts of many researchers and designers have been focused on improvement of vortex tube efficiency by changing the parameters affecting vortex tube operation. The effective parameters are nozzle specifications and inflow pressure conditions. Effects of different nozzle cross-sectional area and number of nozzles are evaluated by computational fluid dynamics (CFD) analysis. In this study, CFD analysis of 3-D steady state and turbulent flow through a vortex tube was performed. We investigated the cold air mass flow rate, the cold air temperature, and the cold air heat transfer rate behavior of a vortex tube by utilizing seven straight nozzles and four inflow pressure conditions.

로봇 냉각을 위한 수냉식 냉각판의 성능 평가 (Performance Test of Liquid Cooling Type Cold Plates for Robot Cooling)

  • 이석원;강상우;황규대;김서영;리광훈
    • 설비공학논문집
    • /
    • 제20권3호
    • /
    • pp.189-196
    • /
    • 2008
  • The increase of system weight due to installation of cooling devices adds electrical and mechanical loads of humanoid robot, and in return, results in much heat. Therefore, the weight of cooling system is a critical issue for robot cooling. In this study, we propose non-metallic cold plates to deal with such problems. We compare thermal performances between one metallic cold plate and five different types of non-metallic cold plates. A metallic cold plate is totally made of copper. Five non-metallic PC(polycarbonate) cold plates, which are designed to reduce the overall weight of robot cooling system, are composed of a polycarbonate cover with different types of base plate. The overall heat transfer coefficients per unit mass and thermal resistances are obtained for the cold plates. The metallic cold plate shows the best thermal performance. It is interesting to note that the PC cold plate with an aluminum base plate with 18 channels shows the best overall heat transfer coefficient per unit mass. Most polycarbonate cold plates display fairly comparable thermal performance with more reduced system weight compared to the metallic cold plate.