• Title/Summary/Keyword: Cold Air Unit

Search Result 53, Processing Time 0.024 seconds

CLINICAL STUDY OF DESENSITIZER FOR TREATMENT OF DENTINAL HYPERSENSITIVITY (상아질 지각과민 처치제의 임상적 효과에 대한 연구)

  • Cho, Kyung-Mo;Shin, Dong-Hoon
    • Restorative Dentistry and Endodontics
    • /
    • v.25 no.2
    • /
    • pp.219-224
    • /
    • 2000
  • The purpose of this study is for evaluating the effect of MS Coat desensitizing agent in clinical situation. In this study total 60 teeth of 30 patients who is feeling hypersensitivity after periodontal surgery were treated with MS Coat desensitizing agent, and 20 teeth with saline solution for placebo effects and evaluated. All teeth were cleaned with rubber cup and pumice, after then the antibacterial agent was applied for 20 seconds and simply isolated using cotton roll Desensitizing agent was applied with a specific instrument in the manufacturers package by abrading motion for 10 seconds and re-done 8 times. Tactile stimulus with sharp explorer, air stimulus with syringe of dental unit, $7^{\circ}C$ cold water stimulus using micropipette applicator was done to evaluate hypersensitivity before apply test agent, immediate after application, 1 week after, and 3 month after application. The degree of hypersensitivity was recorded using 100mm Visual Analogue Scale and compared between group and evaluation times. From this clinical study sensitivity to the stimulus was significantly induced in both groups and MS Coat made a significant reduction in VAS score than placebo group did(p<.01). The results of this study could demonstrate that MS Coat desensitizing agent can use effectively to heat dentinal hypersensitivity.

  • PDF

Humidification model and heat/water balancing method of PEMFC system for automotive applications (자동차용 연료전지 시스템의 가습모델과 열/물균형 유지방법)

  • Jung, Seung-Hun;Yoon, Seok-Ho;Kim, Min-Soo
    • 한국신재생에너지학회:학술대회논문집
    • /
    • 2005.06a
    • /
    • pp.339-344
    • /
    • 2005
  • A PEMFC system model for FCEV was constructed and simulated numerically to examine the heat/water flow of the system and air/fuel humidification process for various operation conditions (ambient pressure /temperature/humidity, operating temperature, power load). We modeled PEMFC stack which can generate maximum electricity of about 80 kW. This stack consists of 400 unit cells and each unit cell has $250cm^2$ reacting area. Uniform current density and uniform operating voltage per each cell was assumed. The results show the flow characteristics of heat and water at each component of PEMFC system in macro-scale. The capacity shortage of the radiator occurred when the ambient was hot $(over\;40^{\circ}C)$ and power level was high (over 50 kW). In spite of some heat release by evaporation of water in stack, heat unbalance reached to 20kW approximately in such a severe operating condition. This heat unbalance could be recovered by auxiliary radiators or high speed cooling fan with additional cost. In cold environment, the capacity of radiator exceeded the net heat generation to be released, which may cause a problem to drop the operating temperature of stack. We dealt with this problem by regulating mass flow rate of coolant and radiator fan speed. Finally, water balance was not easily broken when we retrieved condensed and/or unused water.

  • PDF

Zoning Hydrologic Units for Geospatial Climatology in North Korea (북한지역의 소기후 추정을 위한 수문단위 설정)

  • Kim, Jin-Hee;Yun, Jin-I.
    • Korean Journal of Agricultural and Forest Meteorology
    • /
    • v.13 no.1
    • /
    • pp.20-27
    • /
    • 2011
  • High-definition, geo-referenced digital climate maps can be produced by applying watershed-specific modules to adjust synoptic observations for local effects including cold air drainage. Since there is no information available on North Korean watersheds, existing geospatial technology for digital climate mapping cannot be transferred to North Korea. We applied a watershed extraction algorithm based on ArcHydro to the North Korean portion of ASTER GDEM and utilized geographical information on major rivers and mountains to adjust the products. Proposed hydrologic zoning system for North Korean watersheds consists of 21 river basins, 93 stream basins and 885 catchments. Combined with the existing 840 South Korean hydrologic units, we now have a complete set of 1,725 catchments which may serve a framework for digital climate modeling across whole land area of the Korean Peninsula.

A Numerical Study on the Pressure Drop and Heat Transfer in the Hot Channel of Plate heat Exchanger with Chevron Shape (쉐브론 형상 판형 열교환기의 고온 채널에서의 압력손실 및 열전달 특성에 관한 해석 연구)

  • Sohn, Sangho;Shin, Jeong-Heon;Kim, Jungchul;Yoon, Seok Ho;Lee, Kong Hoon
    • Korean Journal of Air-Conditioning and Refrigeration Engineering
    • /
    • v.30 no.4
    • /
    • pp.175-185
    • /
    • 2018
  • This research investigates the internal flow and heat transfer in a plate heat exchanger with chevron shape by utilizing the computational fluid dynamics (CFD) software. The basic unit of the plate heat exchanger is generally composed of a hot channel, an intermediate chevron plate, and a cold channel. Several studies have reported experimental and numerical simulation of heat transfer and pressure drop. This study focused on the detailed numerical simulation of flow and heat transfer in the complicated chevron shape channel. The long chevron plate was designed to include 16 chevron patterns. For proper mesh resolution, the number of cells was determined after the grid sensitivity test. The working fluid is water, and its properties are defined as a function of temperature. The Reynolds number ranges from 900 to 9,000 in the simulation. A realizable $k-{\varepsilon}$ model and non-equilibrium wall function are properly considered for the turbulent flow. The friction factors and heat transfer coefficient are validated by comparing them with existing empirical correlations, and other patterned flow phenomena are also investigated.

Effect of Varying Excessive Air Ratios on Nitrogen Oxides and Fuel Consumption Rate during Warm-up in a 2-L Hydrogen Direct Injection Spark Ignition Engine (2 L급 수소 직접분사 전기점화 엔진의 워밍업 시 공기과잉률에 따른 질소산화물 배출 및 연료 소모율에 대한 실험적 분석)

  • Jun Ha;Yongrae Kim;Cheolwoong Park;Young Choi;Jeongwoo Lee
    • Journal of the Korean Institute of Gas
    • /
    • v.27 no.3
    • /
    • pp.52-58
    • /
    • 2023
  • With the increasing awareness of the importance of carbon neutrality in response to global climate change, the utilization of hydrogen as a carbon-free fuel source is also growing. Hydrogen is commonly used in fuel cells (FC), but it can also be utilized in internal combustion engines (ICE) that are based on combustion. Particularly, ICEs that already have established infrastructure for production and supply can greatly contribute to the expansion of hydrogen energy utilization when it becomes difficult to rely solely on fuel cells or expand their infrastructure. However, a disadvantage of utilizing hydrogen through combustion is the potential generation of nitrogen oxides (NOx), which are harmful emissions formed when nitrogen in the air reacts with oxygen at high temperatures. In particular, for the EURO-7 exhaust regulation, which includes cold start operation, efforts to reduce exhaust emissions during the warm-up process are required. Therefore, in this study, the characteristics of nitrogen oxides and fuel consumption were investigated during the warm-up process of cooling water from room temperature to 88℃ using a 2-liter direct injection spark ignition (SI) engine fueled with hydrogen. One advantage of hydrogen, compared to conventional fuels like gasoline, natural gas, and liquefied petroleum gas (LPG), is its wide flammable range, which allows for sparser control of the excessive air ratio. In this study, the excessive air ratio was varied as 1.6/1.8/2.0 during the warm-up process, and the results were analyzed. The experimental results show that as the excessive air ratio becomes sparser during warm-up, the emission of nitrogen oxides per unit time decreases, and the thermal efficiency relatively increases. However, as the time required to reach the final temperature becomes longer, the cumulative emissions and fuel consumption may worsen.

Change of Inorganic Component, Reducing Sugar, Catalpol and Benzo[α]pyrene Contents of Rehmannia glutinosa Libosch. var. purpurea Makino by Drying Methods (지황의 건조 방법에 따른 무기성분, 환원당, Catalpol 및 Benzo[α]pyrene의 함량 변화)

  • Chang, Jun-Pok;Kil, Gi-Jung;Lee, Gun-Hee;Ji, Yoon-Sun;Kim, Bo-Ram;Kang, Ki-Hyun;Kim, Mee-Ree;Song, Mi-Ran;Park, Jong-Yoon;Doh, Eun-Soo
    • Korean Journal of Medicinal Crop Science
    • /
    • v.19 no.6
    • /
    • pp.501-507
    • /
    • 2011
  • This experiment was carried out in order to collect the basic data on the standardization of the manufacturing process of Rehmannia glutinosa Libosch. var. purpurea Makino drying. By the drying methods of R. glutinosa, the content of water, inorganic components, reducing sugar, catalpol and benzo[${\alpha}$]pyrene were investigated. The water content was 15.6~17.2% when R. glutinosa was dried by cold-warm air moisture absorption drying method (CAMAD) at $60^{\circ}C$ during 6 days. Among of the inorganic components of R. glutinosa the K content was the most followed by P, Na, Ca and Mg. The reducing sugar content of R. glutinosa by the hot air drying method (HAD) was much more than that by the CAMAD. The catalpol content of R. glutinosa was not different by the drying temperature when it was dried by the CAMAD. The catalpol content of the large size tuber (about 50.0 g/unit) showed a tendency to increase from $60^{\circ}C$ until $70^{\circ}C$ drying temperature, but that of the small size tuber(about 4.0 g/unit) was decreased as being a trend as the drying temperature high when R. glutinosa was dried by the HAD, But the catalpol content R. glutinosa had a tendency to drop significantly at drying temperature above $80^{\circ}C$. The benzo[${\alpha}$]pyrene content was little detected when R. glutinosa was dried by both the SLD and the CAMAD, and the sampling by the HAD indicated within the scope of 5 ${\mu}g/kg$ which was the scope to regulate by Korean food and drug administration. In conclusion, it seemed that an appropriate drying temperature of R. glutinosa by the CAMAD and the HAD was about $60^{\circ}C$ and about $70^{\circ}C$, respectively, when we consider the catalpol content and benzo[${\alpha}$]pyrene detection in the manufacturing process of drying R. glutinosa.

Application of Simplified Curing Unit for the Extension of Storage Life and Improvement of Physicochemical Quality of Sweet Potatoes during Long-term Storage (간이 큐어링 설비를 이용한 큐어링 처리가 장기간 저장 중 고구마의 품질 개선에 미치는 영향)

  • Song, Jeong-Hwa;Kim, Sung-Kyeom;Chun, Chang-Hoo
    • Journal of Bio-Environment Control
    • /
    • v.20 no.4
    • /
    • pp.304-310
    • /
    • 2011
  • To evaluate the effect of curing treatment using a newly developed simplified curing unit (SCU) on the physicochemical quality of stored sweet potatoes was investigated for six months. The SCU consisting of a heater, an air circulation fan, exhaust fans, and a humidifying duct was installed in a cold storage room where the harvested sweet potatoes were stacked. During the six days of curing treatment, air temperature and relative humidity in the storage room were set at $32^{\circ}C$ and 90%, respectively. Physical and chemical properties of sweet potatoes were measured at 1-month intervals from the first day of storage. McKinney index showing the incidence and severity of decay was 0.83% in the curing treatment, while that of untreated control was 5.08% over the same storing period. Firmness, soluble solids content, and dry matter content in the cured sweet potatoes were greater than those of untreated control. Moreover, the changes of skin color in uncured potatoes occurred rapidly than cured one which showed delay of skin discoloration during the long-term storage. Results suggest that the SCU treatment improves the physicochemical quality of stored sweet potatoes and extends their storability. Therefore, the SCU can be effectively used for curing treatment of sweet potatoes with a relatively low cost.

Study of Hydration Reaction Characteristics of Inorganic Salts for Chemical Cold Storage and Method of Enhancement of Heat and Mass Transfer (화학축냉용 무기염들의 수화반응 및 열 및 물질전달 향상방안)

  • 김상욱;한종훈;황용준;이건홍
    • Proceedings of the Korea Society for Energy Engineering kosee Conference
    • /
    • 1999.05a
    • /
    • pp.185-191
    • /
    • 1999
  • An air-conditioning system based on the chemical heat storage principle was considered. $H_2O$ was chosen as the reaction gas and the working fluid as well. Na$_2$S, CaCl$_2$, MnCl$_2$, BaCl$_2$, MgCl$_2$, Fe$_2$(SO$_4$)$_3$ and MnSO$_4$ were tested as the solid reactants by using Cahn pressure balance. Na$_2$S was superior to other salts in respect of high capability of absorption of water gas, 5 moles of $H_2O$ per unit mole of Na$_2$S, and adequate temperature of adsorption, $65^{\circ}C$ at 7torr, and of desorption, 13$0^{\circ}C$ at 76torr. Clausius-Clapeyron diagram of Na$_2$S was obtained via adsorption experiments at several vapor pressures of water gas. To enhance heat and mass transfer characteristics, usually below 1W/m K, of the reactor bed of general adsorption systems, expanded graphite block was adapted as the support of Na$_2$S salt. Expanded graphite blocks had thermal conductivity values of 20~80W/mK with respect to 100~400kg/㎥ of block bulk density. Permeability values of expanded graphite blocks were 10$^{-13}$ ~ 10$^{-14}$ $m^2$ with respect to 100~300kg/㎥ of block bulk density showing highly decreasing values of permeability, below 10$^{-l4}$$m^2$, in the range of above 150kg/㎥ of block bulk density.y.

  • PDF

Effect of Pre-treatment and Packaging Method on Freshness Prolongation of Spring Kimchi Cabbage during Low Temperature Storage (봄배추의 전처리 및 포장방법이 저온저장 중 선도유지에 미치는 효과)

  • Se-Jin Park;Ji-Young Kim;Andri Jaya Laksana;Byeong-Sam Kim
    • KOREAN JOURNAL OF PACKAGING SCIENCE & TECHNOLOGY
    • /
    • v.29 no.2
    • /
    • pp.119-128
    • /
    • 2023
  • This study was examined for investigating the quality changes of spring kimchi cabbage under various treatments (pre-drying/pre-cooling, packaging types, and stacking and loading in container and pallete in the storage room) during cold storage. The results showed that control (upward stacking without pre-drying/pre-cooling and HDPE or PVC film cover) was increased significantly in weight loss and trimming loss, compared to other treatments such as DPDH (downard stacking + pre-drying + HDPE), DPDP (downard stacking + pre-drying + PVC), DPCH (downnard stacking + pre-cooling + HDPE), and UPCH (upward stacking + pre-cooling +HDPE) during storage for three months. In Sensory evaluation, judging from marketable properties, the desirable appearance of spring kimchi cabbage with the modified pallet-unit MA packed, PE, and PVC film wrapping could be maintained until 9 weeks after pre-drying/pre-cooling. Meanwhile, the control without any treatments after 6 weeks, the sensory score was declined, significantly. In general, the low temperature (10℃ and 2℃) of pre-treatment with combination of plastic film packaging in spring kimchi cabbage storage could inhibit the physiological activity and reduce the direct exposure of environmental cold air in the storage. Therefore, these two variables were the key points for extending the shelf-life of spring kimchi cabbage.

Applications of "High Definition Digital Climate Maps" in Restructuring of Korean Agriculture (한국농업의 구조조정과 전자기후도의 역할)

  • Yun, Jin-I.
    • Korean Journal of Agricultural and Forest Meteorology
    • /
    • v.9 no.1
    • /
    • pp.1-16
    • /
    • 2007
  • The use of information on natural resources is indispensable to most agricultural activities to avoid disasters, to improve input efficiency, and to increase lam income. Most information is prepared and managed at a spatial scale called the "Hydrologic Unit" (HU), which means watershed or small river basin, because virtually every environmental problem can be handled best within a single HU. South Korea consists of 840 such watersheds and, while other watershed-specific information is routinely managed by government organizations, there are none responsible for agricultural weather and climate. A joint research team of Kyung Hee University and the Agriculture, forestry and Fisheries Information Service has begun a 4-year project funded by the Ministry of Agriculture and forestry to establish a watershed-specific agricultural weather information service based on "high definition" digital climate maps (HD-DCMs) utilizing the state of the art geospatial climatological technology. For example, a daily minimum temperature model simulating the thermodynamic nature of cold air with the aid of raster GIS and microwave temperature profiling will quantify effects of cold air drainage on local temperature. By using these techniques and 30-year (1971-2000) synoptic observations, gridded climate data including temperature, solar irradiance, and precipitation will be prepared for each watershed at a 30m spacing. Together with the climatological normals, there will be 3-hourly near-real time meterological mapping using the Korea Meteorological Administration's digital forecasting products which are prepared at a 5 km by 5 km resolution. Resulting HD-DCM database and operational technology will be transferred to local governments, and they will be responsible for routine operations and applications in their region. This paper describes the project in detail and demonstrates some of the interim results.