• 제목/요약/키워드: Cold Air Unit

검색결과 54건 처리시간 0.03초

열전소자를 이용한 싱글 및 캐스케이드 냉동시스템의 냉각 성능에 관한 연구 (Study on the Cooling Performance of Single and Cascade Refrigeration Systems Using Thermoelectric Modules)

  • 임창학;김동우;김용찬;서국정
    • 설비공학논문집
    • /
    • 제25권12호
    • /
    • pp.641-646
    • /
    • 2013
  • The purpose of this study is to improve the cooling performance of single and cascade refrigeration systems using thermoelectric modules. The system consists of a heat sink, fan, and thermoelectric module. The operating parameters considered in this study include power distribution between the first- and second-stage thermoelectric modules, air flow, and variable condensing unit. The cooling capacity increased with decreases in the temperature difference between hot and cold surfaces, but decreased with increases in the condensing temperature. The COP decreased with increasing electric power of the thermoelectric module because of the increased Joule heat. The cooling performance improvement using the thermoelectric module is represented by the freezer temperature.

한국 서남해 함평만 조간대 퇴적층의 제4기 후기 층서 연구 (Late Quaternary Stratigraphy of the Tidal Deposits In the Hampyung Bay, southwest coast of Korea)

  • 박용안;임동일;최진용;이영길
    • 한국해양학회지:바다
    • /
    • 제2권2호
    • /
    • pp.138-150
    • /
    • 1997
  • 한반도 서남 해역에 위치한 함평만(전라남도 함평군) 조간대 퇴적층의 제 4기 후기 층서와 퇴적학적 연구를 위하여 총 37 지점에서 평균 3 m 깊이(최대 5.2 m)의 시추가 실시되었다. 채취된 퇴적물 시료의 입자 조직(grain texture), 퇴적 구조(sedimentary structure), 색(color) 및 광물 조성(mineral composition) 등을 토대로 10개의 퇴적상(sedimentary facies)이 분류되었다. 분석 결과에 의하면, 함평만 조간대 퇴적분지의 층서는 상위로부터 순차적으로 층서단위 Unit I, Unit II 및 Unit III로 구성된다. 최상위의 층서단위 Unit I은 조립질 퇴적상인 비조직 사질역 퇴적상(Facies SGd)과 괴상 역질 이토 퇴적상(Facies GMm) 또는 세립질 퇴적상인 엽층리 실트 퇴적상(Facies Zp), 괴상 이토 퇴적상(Facies Mm) 및 평행 엽층리 이토 퇴적상(Facies Mp)으로 구성되며, 상향 조립화의 특정을 나타낸다. 이 퇴적층은 해수면이 거의 현재의 위치에 도달된 지난 약 4.000년 동안 형성된 후기 현세(late Holocene) 해침 퇴적층으로 해석된다. Unit I에 의하여 부정합적으로 피복되는 층서단위 Unit II는 준 고화된 황색 이토 퇴적상 (Facies Mym)과 회색의 미고결된 니질 퇴적상(Facies Mgm)으로 구성되며, 수평적 연속성이 양호하고, 함평만 전체에 광역적으로 분포한다. Unit II는 서해의 여러 조간대에서 보고된 간월도층과 대비되는 것으로 여겨지며, 후기 플라이스토세(late Pleistocene)의 조간대 퇴적환경에서 집적된 퇴적층으로 해석된다. 이러한 Unit II에는 지난 최대 빙하기 동안 대기중에 노출된 다양한 증거(황갈색, 고화상태, 동토구조, 점토광물의 함량 변화등) 들을 함유한다. Unit II에 의하여 부정합적으로 피복되는 Unit III는 역질의 층리를 갖는 조립의 퇴적물(Facies SGb와 Facies Sx)로 구성되며 내만역의 한정된 지역(후동과 시목동 해역)에 분포한다. 퇴적학적 특성과 지역적인 분포 양상을 고려할 때, Unit III는 육성 환경(nonmarine deposits)의 하천 퇴적물(fluvial sediment)로 해석된다. 결과적으로 함평만 조간대 퇴적분지의 층서(최고기로부터 최신기)는 기반암 지층(중생대 화강암)${\rightarrow}$육성 퇴적층(Unit III)${\rightarrow}$후기 플라이스토세의 니질 조간대 퇴적층(Unit II)${\rightarrow}$후기 현세의 조간대 퇴적층(Unit I)의 층서이며, 각각의 층서단위의 경계는 부정합적이다.

  • PDF

슬러지 순산소 유동층 연소특성 (Combustion Characteristics of Waste Sewage Sludge using Oxy-fuel Circulating Fluidized Bed)

  • 장하나;성진호;최항석;서용칠
    • Korean Chemical Engineering Research
    • /
    • 제55권6호
    • /
    • pp.846-853
    • /
    • 2017
  • 순환유동층 모사장치와 $30kW_{th}$급 파일럿 연소기를 활용하여 슬러지 순산소 유동층 연소특성을 살펴보았다. 순환유동층 모사실험에서 최소유동화속도($U_{mf}$)는 0.120 m/s로 계산되었고, 고속유동화를 위한 공탑속도는 2.5 m/s 이상으로 결정되었다. 파일럿 연소실험에서는 일반공기 및 21~40% 순산소 연소실험이 수행되었다. 배출가스 온도의 경우 21~25% 순산소 연소가 일반공기 및 30% 이상의 순산소 연소보다 상대적으로 높았다. 또한, 배출가스 중 $CO_2$ 배출농도가 21~25% 순산소 연소 범위에서 80% 이상으로 나타났다. 이를 고려한 전반적인 연소특성을 살펴 보았을 때 25% 순산소 연소가 본 슬러지 연료 연소에 대한 장시간 운전에 있어 보다 적합한 것으로 사료된다.

원수열원 히트펌프 축열시스템의 동절기 성능분석 (Winter Season Performance Characteristics of Raw Water-Source Heat Pump System with a Thermal Storage Tank)

  • 조용;이동근
    • 한국신재생에너지학회:학술대회논문집
    • /
    • 한국신재생에너지학회 2011년도 춘계학술대회 초록집
    • /
    • pp.202-202
    • /
    • 2011
  • Performance of the raw water-source heat pump system with a thermal storage tank has been analyzed in winter season. The raw water is transferred through the multi-regional water supply system from Han river. Raw water is large temperature difference resource compared with groundwater. Although the raw water temperature drops to $0.6^{\circ}C$ due to the heavy snowfall and the severe cold in late January and early February, 2010, the system has been normally operated without any trouble this winter. The unit COP and system COP considered all pump power consumption were estimated based on the second-by-second data of the all sensors. The monthly averaged unit COP and system COP are 3.37 and 2.76 respectively with $1.4^{\circ}C$ of raw water in January, 3.55 and 2.89 with $1.6^{\circ}C$ raw water in February, 3.82 and 3.15 with $5.4^{\circ}C$ raw water in March. The performance of the system are increased with raw water temperature, and the COPs are higher than the water-to-air heat pump system using relatively high temperature raw water from Daecheong reservoir because the water-to-water system was operated on the full load condition and was stopped when the thermal storage tank was full of the high temperature water.

  • PDF

마이크로컴퓨터를 이용한 가솔린 기관용 전자제어장치의 개발에 관한 연구 (A Study on the Development of an Electronic Control Unit for a Gasoline Engine using Microcomputer)

  • 김태훈;조진호
    • 한국자동차공학회논문집
    • /
    • 제3권6호
    • /
    • pp.224-237
    • /
    • 1995
  • An ECU(Electronic Control Unit) with 16 bit microcomputer has been developed. This system includes hardware and software for more precise control on fuel injection, ignition timing, and idle speed. This control system employs an air flow sensor of the hot wire type, a direct ignition system, an idle speed control system using a solenoid valve, and a crank angle sensor. Especially, the crank angle sensor provides two separate signals: One is the position signal(POS) which indicates 180 degree pulses per revolution, and the other is the reference signla(REF) that represents each cylinder individually. The conventional engine control system requires at least two engine revolutions in order to identify the cylinder number. However, the developed engine control system can recognize the cylinder number within a quarter of an engine revolution. Therfore, the developed engine control system has been able to control fuel injection and ignition timing more quickly and accurately, Furthermore, the number of misfire reduces during the cold start.

  • PDF

복사열 반사판의 설계를 위한 광학적 해석 및 실험기법 (Optical Analysis and Experimental Method for Design of Radiative Thermal Reflector)

  • 정해용;송태호;유승열
    • 설비공학논문집
    • /
    • 제20권8호
    • /
    • pp.563-569
    • /
    • 2008
  • Radiative, heating is suitable for outdoor heating system in windy and cold seasons. Optimal design of the reflector is very important to maximize heat transfer to a specific target area in the open space. The geometrical optical theory can be applied to analyze efficiency of the reflector. Commercial ray tracing computer programs are available only for limited geometries of the reflector. Alternatively, it may be designed and analyzed through an approximated simple lens theory. Two types of reflectors are analyzed using either of these methods. The key issue in this paper is to propose a new illumination experimental method for determination of the radiative efficiency. Optical light source and illuminometer are employed. The calculated efficiency of the reflector is compared with experimental one for checking the reliability. The relative errors between the experimental and analytical results are less than 5%, which proves the validity of this method. Based on these methodologies, a practical reflector and heating lamp unit is developed.

북한 핵의 맥락적 이해 (Contextual Understanding of North Korea Nuclear Problem)

  • 박봉규
    • 한국과 국제사회
    • /
    • 제1권1호
    • /
    • pp.97-114
    • /
    • 2017
  • 본고의 목적은 북한 핵문제 해결의 단서를 모색하기 위하여 북한 핵 문제를 맥락적으로 이해하려는 것이다. 다양한 시도가 무산된 상황에서 북한 핵 문제를 백지 상태에서 가늠해 보자는 것이다. 북한 핵문제는 북한 내부의 전개과정과 밀접하면서 동시에 국제정치적 함의 변화와 관련된다. 북한 핵문제가 체제 생존의 노력으로부터 파생되어 학습 효과에 의해 진화한 프로젝트일 가능성이 크다는 것이다. 소련의 영향으로 발아된 북한 핵문제가 '자위의 원칙'과 결합되면서 중 소 분쟁 등 국제정치적 상황에 의해 진화되었다. 냉전체제 붕괴와 탈냉전기의 도래는 획기적인 변화를 가져왔다. 북한 안보환경의 악화와 더불어 9 11 테러 이후 소위 '악의 축'이 보유하고 있는 대량파괴무기와 테러집단의 연결 가능성은 북한 핵문제를 세계안보 차원으로 확대시켰다. 그러므로 북한 핵문제는 체제생존, 냉전체제의 붕괴, 탈냉전기 안보함의의 변화라는 맥락 속에서 다양한 가능성을 전제하고 지속적인 수렴 과정을 통해 해결의 영역을 확보해야 한다.

덕트형 항온챔버에서 히트펌프 실외기의 성능평가 가능성에 대한 CFD (CFD on the possibility of performance evaluation of heat pump outdoor unit in duct-type constant temperature chamber)

  • 김종열
    • 융합신호처리학회논문지
    • /
    • 제22권3호
    • /
    • pp.116-121
    • /
    • 2021
  • 에너지를 절약하기 위해 고효율 히트펌프를 개발하기 위한 많은 연구가 이루어지고 있으며, 실외기 코일에 발생하는 서리가 발생하는 현상을 줄이거나 없애기 위한 연구도 동시에 이루어지고 있다. 계절과 관계없이 히트펌프의 실외기에 서리가 발생하지 않는 연구를 진행할 수 있도록 자연 상태와 동일한 조건에서 실험할 수 있는 곡선형 항온챔버를 구축하였다. 이러한 곡선형 항온챔버가 실험 장치로서 타당성을 갖추고 있는지 검증하기 위해 시뮬레이션을 하였다. CFD 조건은 곡선형 항온챔버 내에 위치한 실외기 앞의 직선형 덕트 길이를 덕트 관경의 1배, 5배, 10배, 15배로 하였다. 그 결과 덕트 관경의 10배 길이로 시뮬레이션했을 때 자연 상태와 가장 유사하다는 것을 알게 되었다.

해양심층수 기능성소금 제조를 위한 분무건조기 특성의 수치해석적 연구 (A Numerical Study on the Spray Dryer Characteristic for Manufacture of Deep Sea Water Salt)

  • 김현주;신필권;박성제
    • 한국해양공학회:학술대회논문집
    • /
    • 한국해양공학회 2003년도 추계학술대회 논문집
    • /
    • pp.24-29
    • /
    • 2003
  • Deep sea water has cold temperature, abundant nutrients and minerals, and good water quality that is pathogen-free and stable. Compared with surface water, deep sea water contains more nutrition salt, such as nitrogen and phosphor. Moreover, if has the good balance of minerals. Because of the ability of the spray drying process to produce a free-flowing power considering of spherical particles with a well-defined size distribution and the rapid drying times for heat-sensitive material, spray drying is attractive for a wide range of applications spray drying is a unique unit operation in which powders are produced from a liquid feed in a single processing step. Key component of the process are atomizer, spray chamber. Design of spray chamber should be based on the atomizer type, the production rate, and the particle size required. Because of the complex processes taking place during spray drying, traditional design method are based on pilot-plant tests and empirical scale-up rules. Modern technique such as CFD have a role to play in design and troubleshooting.

  • PDF

Improvement of Condensation Performance in Corridor Type Apartment Door

  • Lee, Sungbok;Hwang, Hajin
    • Architectural research
    • /
    • 제10권1호
    • /
    • pp.33-39
    • /
    • 2008
  • Condensation has mainly occurred in corridor type apartment door which is exposed to the outside air and is made of steel, which has high thermal conductivity. As a result, the total costs of repair have increased with the number of disputes with residents. In this study, therefore, we investigate materials and construction methods used in apartment door, perform a computer simulation to find out possible improvements, and then suggest the dew point to prevent the occurrence of condensation throughout simulation. The results indicate that the temperature that condensation does not occur is $15.4^{\circ}C$, and the optimum method of achieving this dew point is shown to be a door frame system including a large vertical slot to decrease the area of thermal conduction between the outer and inner portions of the door frame. Mock-up tests show that the surface temperature of the door frame was higher than the dew point, and the system can withstand severe cold conditions of $-20^{\circ}C$. In application test, the surface temperature of door frame with vertical slots is $5.9^{\circ}C$in average, which is higher than the existing door frame. Furthermore, in the temperature distribution of the surrounding door measured with infrared ray camera, the existing door shows the high temperature distribution indicating lack of insulation, but the improved door shows the low temperature distribution indicating higher insulation.