• 제목/요약/키워드: Coil performance

검색결과 601건 처리시간 0.025초

수직으로 매설된 이중관형 지중 열교환기에 대한 해석적인 연구 (Numerical analysis of the vertical tube-in-tube ground coil heat exchanger)

  • 유지오;금성민;신현준
    • 설비공학논문집
    • /
    • 제11권3호
    • /
    • pp.339-348
    • /
    • 1999
  • A computer model was developed in order to predict the temperature distribution and the performance of the vertical tube-in-tube ground coil heat exchanger. This model has been validated by experimental results conducted by ORNL. The heat exchanger performance with the variation of the length is calculated and compared. As results, the heat exchanger performance is proportional to the length but the performance per unit length decreases. The minimum performance of 70m - PVC heat exchanger during cyclic operation for a week is obtained 20,054kJ/h for cooling operation and 13,915kJ/h for heating operation. And minimum temperature difference is $4.64^{\circ}C$ for cooling operation and $2.64^{\circ}C$ for heating operation. In each case, it is noted that the temperature difference between the pipe and the far-field occurs within 0.8m from the heat exchanger.

  • PDF

Design of a Rectangular-Type Voice Coil Actuator for Frame Vibration Compensation

  • Choi, Young-Man;Ahn, Dahoon;Gweon, Dae-Gab;Lee, Moon Gu
    • Journal of Magnetics
    • /
    • 제21권3호
    • /
    • pp.348-355
    • /
    • 2016
  • Precision motion stages used in the manufacturing process of flat-panel displays have inevitably low settling performance due to their huge mass and bulky structures. In order to improve the settling performance, several methods of frame vibration compensation have been developed so far. These methods are used to cancel the vibration by imposing a counter force or modifying the resonance mode of the frame of the stage. To compensate the frame vibration, high force actuators are required. In this paper, a mighty voice coil actuator is proposed to generate the counter force against the frame vibration. The proposed voice coil actuator has an axis-symmetric rectangular structure to achieve a large force with simple and low cost fabrication. Also, the voice coil actuator allows radial clearance up to ${\pm}4mm$. Using an optimized design process and a magnetic circuit model, the power consumption is minimized while the required force is obtained. With a power of 322 W, the VCA has been designed to have a maximum force of 574 N with a force constant of 164 N/A. Experimental results verified the force constant of the fabricated voice coil actuator is well matched with the designed value.

건물 공조용 냉수 코일의 열 설계 (Thermal Design of a Cooling Coil for Building Air Conditioning)

  • 김내현;변호원
    • 한국산학기술학회논문지
    • /
    • 제16권10호
    • /
    • pp.6445-6452
    • /
    • 2015
  • 건물용 공기조화기의 냉수 코일은 작동조건에 따라 건표면, 습표면 또는 부분적인 습표면이 형성된다. 따라서 냉수코일을 적절히 설계하기 위해서는 건표면과 습표면, 그리고 부분적 습표면에 대한 열전달 해석이 필요하다. 본 연구에서는 미소체적에 대한 해석을 통하여 냉수코일의 성능을 계산하는 미소체적 모델을 제시하였다. 해석 모델의 예측치를 냉수코일 실험결과와 비교한 결과 미소 체적 모델은 공기측 전열량을 10.1% 이내에서 예측하고 공기측 압력손실을 11.1%, 현열비도 5.7%내로 예측하였다. 해석 모델을 활용하여 물측 회로의 변화가 냉수코일의 성능에 미치는 영향을 검토하였다.

Coil Insert에 의한 회전열파이프의 내부유동 및 열전달특성에 관한 연구 (A Study on Characteristics of Internal flow Pattern and Heat Transport Performance by Installing a Coil Insert in the Inside Wall of a Rotating Heat Pipe)

  • 김선주;이진성;김철주;박이동
    • 한국에너지공학회:학술대회논문집
    • /
    • 한국에너지공학회 1996년도 추계학술발표회 논문집
    • /
    • pp.181-189
    • /
    • 1996
  • 회전열파이크는 전기모터, 고온가스터빈 등의 냉각에 이용함으로써 성능개선을 얻을 수 있다는 점에서 지난 20년 동안 많은 연구가 이루어져왔다. 그동안 내부벽면형상개발은 Taper를 설치하거나, 계단식 단면변화 또는 Impeller설치와 같은 기술들이 연구되었다. 본 연구는 회전 열파이프 용기내벽에 Coil Insert를 설치하여 응축액막 유동효과에 대한 가시화실험 및 열전달 성능실험을 통하여 그 특성을 검토하였고 아래와 같은 결과를 얻을 수 있었다. 1) Pool 영역에서는 Coil Insert에 의한 축방향 펌프효과가 매우 크며, 그 효과는 나선각이 클수록 크게 나타난다. 2) Coil Insert는 Pool에서 환상류로 천이를 촉진시키며, 나선각이 클수록 그 효과가 크게 나타난다. 3) Coil insert 열파이프의 열저항에 미치는 효과는 크지 않은 것으로 보인다. 4) Coil Insert에 의해 Dry-out한계의 증가가 예상되지만, 실험장치의 열부하한계에 의해 확인할 수 없었다.

  • PDF

Magnetic Field Gradient Optimization for Electronic Anti-Fouling Effect in Heat Exchanger

  • Han, Yong;Wang, Shu-Tao
    • Journal of Electrical Engineering and Technology
    • /
    • 제9권6호
    • /
    • pp.1921-1927
    • /
    • 2014
  • A new method for optimizing the magnetic field gradient in the exciting coil of electronic anti-fouling (EAF) system is presented based on changing exciting coil size. In the proposed method, two optimization expressions are deduced based on biot-savart law. The optimization expressions, which can describe the distribution of the magnetic field gradient in the coil, are the function of coil radius and coil length. These optimization expressions can be used to obtain an accurate coil size if the magnetic field gradient on a certain point on the coil's axis of symmetry is needed to be the maximum value. Comparing with the experimental results and the computation results using Finite Element Method simulation to the magnetic field gradient on the coil's axis of symmetry, the computation results obtained by the optimization expression in this article can fit the experimental results and the Finite Element Method results very well. This new method can optimize the EAF system's anti-fouling performance based on improving the magnetic field gradient distribution in the exciting coil.

관외착빙형 빙축열조의 방열성능 모델링 (Modelling of Thermal Discharge Performance for Ice-on-coil Type Ice-Storage Tank)

  • 이상렬;이경호;최병윤;한승호
    • 대한기계학회:학술대회논문집
    • /
    • 대한기계학회 2001년도 춘계학술대회논문집D
    • /
    • pp.280-285
    • /
    • 2001
  • This paper presents a modelling of thermal discharge performance for a static ice-on-coil ice-storage tank. Through the present study, discharging characteristics were examined with the existing results of theoretical and numerical heat transfer analyses. Also, an experiment was conducted to obtain a real set of discharge performance. The thermal effectiveness, the ratio of the actual heat transfer rate to the maximum possible heat transfer rate, decreased when the stored energy decreased during discharging period. And the effectiveness increased as the coolant flow rate through the storage increased, of which increasing rate decreased abruptly near the maximum and the minimum stored energy. An empirical correlation was obtained from the experimental and the numerical analysis data.

  • PDF

와이어코일 삽입법을 이용한 열전달 촉진기술 성능평가 (Evaluation of Heat Transfer performance of Wire-coil Inserted Tube)

  • 이주동;박종호;이상천
    • 설비공학논문집
    • /
    • 제12권5호
    • /
    • pp.457-465
    • /
    • 2000
  • An experiment was carried out to evaluate the thermal performance of the wire-coil inserts method. Tested were the smooth tubes with the wire-nil inserts of various pitch and helix angle combinations. Test fluids were the 50%-solution of the ethylene glycol and the Hue water. Heat transfer coefficient and friction factors were deduced from the measured values of temperatures, flowrates and pressure drops. A unified dimensionless correlation for the heat transfer coefficients was developed as a function of the pitch to diameter ratio, the Reynolds number and the Prandtl number. An exergy analysis was performed to evaluate an optimal operating condition with the wire-coil inserts.

  • PDF

고압 유도전동기 고정자권선의 결함에 따른 부분방전발생양상의 특징분석 (Characteristic Analysis of PD Occurrence Aspects for Defect of Stator Coil in HV Induction motor)

  • 이강원;김명룡;백광선;장동욱;임기조
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 2005년도 제36회 하계학술대회 논문집 C
    • /
    • pp.2226-2228
    • /
    • 2005
  • High voltage induction motor is the important equipment for ensuring the driving performance of the electric train. PD(partial discharge) is a good indicator for showing the insulation performance of stator coil in HV induction motor. This paper has investigated the characteristics of PD occurrence aspects for both the sound and defective stator coil which consist of maximum PD amplitude(V), total occurrence number, average PD amplitude(V) and PD amplitude(v) - PD occurrence number(n). They were compared with each other depending on applied voltages and reconstructed to $60{\times}60$ matrices of PD amplitude(v)-occurrence phase (${\phi}$)-occurrence number(n) which is the good way to estimate the PD sources in stator coil.

  • PDF

LED-TV용(用) 전원장치에 적합한 Hybrid 초크 코일의 특성 해석에 관한 연구 (A Study on the Characteristic Analysis of Hybrid Choke Coil suitable for LED-TV SMPS)

  • 김종해;김희승;원재선
    • 조명전기설비학회논문지
    • /
    • 제28권3호
    • /
    • pp.32-43
    • /
    • 2014
  • This paper presents the intra capacitance modeling according to the winding method, section bobbin and coil structure for hybrid choke coil capable of the EMI attenuation of broad bands from lower frequency bands to higher frequency bands and high frequency type common-mode choke coil capable of the EMI attenuation of high frequency band used in the EMI Block of LED-TV SMPS. In case of high frequency type CM choke coil, it can be explained the parasitic capacitance of A type and section bobbin type winding methods among them is much smaller than the other. The first resonant frequency of the proposed CM choke coil tends to increase as the parasitic capacitance becomes small and its impedance characteristics also show improved performance as the first resonant frequency increases. In case of hybrid choke coil using rectangular copper wire, it has investigated its parasitic capacitance compared to CM choke coil of conventional toroidal type becomes small. Also it has confirmed through the experiment results that CE margin and RE margin in frequency bands 0.5MHz to 5MHz and 30MHz to 200MHz are respectively 10dB and 15dB greater than that of conventional type in case of one stage EMI filter structure adopting hybrid choke coil compared to two stage EMI Filter structure using two of each CM choke coil used in the lower and higher frequency bands or two of CM choke coil used in only the lower frequency bands. In the future, the hybrid choke coil and CM choke coil of high frequency type show it can be practically used in not only LED/LCD-TV SMPS but also several applications such as LED Lighting, Laptop Adapter, Server Power Supply and so on.

로고우스키코일을 이용한 과도전류의 측정 (Measurement of Transient Current by using the Rogowski Coil)

  • 이복희;길경석;정승수;정상진
    • 대한전기학회논문지
    • /
    • 제43권7호
    • /
    • pp.1206-1213
    • /
    • 1994
  • This paper presents the operation principle and design rule of the Rogowski coil which can measure the transient current and describes the calibration and application experimental results for performance evaluation. It is obtained that the response curves of the Robowski coil with the turns of 300 and the passive integrator to sinusoidal input give a good linearity up to the frequency of 500 [kHz] and the current measurement system gaving the Rogowski coil is the frequency bandwidth of 40 [Hz]~700 [kHz]. As an application experiment for the fabricated modeling power transmission line, the impulse current, which limitates the direct lightning return stroke to overhead ground wire, is measured by the Rogowski coil and its fast Fourier transformation is carried out. The equivalent circuit of the Rogowski coil considering the stray capacitances is proposed, and the theoretical analysis is in good agreement with the measurement results. Also, it is found that for high frequency domain the stray capacitance such as a distributed capacitance to the shield and the capacitance between windings of coil should be considered in designing the Rogowski coils since the resonance originates from the stray capacitance and the self-inductance of the Rogowski coil.

  • PDF