Intentional Sparing of Daughter Sac from Coil Packing in the Embolization of Aneurysms Causing the Third Cranial Nerve Palsy : Initial Clinical and Radiological Results

  • Kang, Chang-Woo;Kwon, Hyon-Jo;Jeong, Se-Jin;Koh, Hyeon-Song;Choi, Seung-Won;Kim, Seon-Hwan
    • Journal of Korean Neurosurgical Society
    • /
    • v.48 no.2
    • /
    • pp.115-118
    • /
    • 2010
  • Objective : Cerebral aneurysms which cause oculomotor nerve [cranial nerve (CN) III] palsy, are frequently found with a daughter sac of the aneurysm dome. We assumed that CN III might be compressed by the daughter sac and it would be more helpful not to fill the daughter sac with coils than vice versa during endosaccular embolization for recovering from CN III palsy, because it may give a greater chance for the daughter sac to shrink by itself later. We reviewed the initial results of our experiences of such cases. Methods : Among 9 aneurysms accompanied by CN III palsy, 7 (6 unruptured, 1 ruptured) showed a daughter sac. We tried to fill the main dome completely and spare the daughter sac from coil filling to increase the possibility of decompression. We evaluated the short-term effectiveness of this concept using medical records and angiograms. Results : After initial embolization, all of CN III palsy caused by unruptured aneurysms (6/6) resolved completely after various periods (3-90 days) of time. No adverse effects were noted during and after the procedures except for one case of harmless coil stretching during coil filling using double microcatheter. Conclusion : During the coil embolization of the cerebral aneurysm causing CN III palsy, sparing the daughter sac from coil packing while tightly packing the main dome, can be helpful in increasing the effectiveness of decompression. However, a long-term follow-up will be required.

Endovascular Rescue Method for Undesirably Stretched Coil

  • Cho, Jae Hoon
    • Journal of Korean Neurosurgical Society
    • /
    • v.56 no.4
    • /
    • pp.364-367
    • /
    • 2014
  • Undesirable detachment or stretching of coils within the parent artery during aneurysm embolization can be related with thrombus formation, which can be caused occlusion of parent artery or embolic event(s). To escape from this situation, several rescue methods have been reported. A case with undesirably stretched coil in which another rescue method was used, is presented. When the stretched coil is still located in the coil delivery microcatheter, the stretched coil can be removed safely using a snare and a handmade monorail microcatheter. After a snare is lodged in the handmade monorail microcatheter, the snare is introduced over the coil delivery micorcatheter and located in the distal part of the stretched coil. After then, the handmade monorail microcatheter captures the stretched coil and the snare as one unit. This technique using a handmade monorail microcatheter and a snare can be a good rescue modality for the undesirably stretched coil, still remained within the coil delivery microcatheter.

Evaluation of Radiation Dose according to Aneurysm Size and Location during Cerebral Aneurysm Coil Embolization (뇌동맥류 코일 색전술 시술 시 동맥류 크기 및 위치에 따른 방사선량 평가)

  • An, Hyun
    • Journal of radiological science and technology
    • /
    • v.45 no.5
    • /
    • pp.407-412
    • /
    • 2022
  • Cerebral aneurysm coil embolization has the advantages of accurate, low patient burden, and fast recovery time, but efforts are needed to reduce dose due to the burden of exposure radiation dose during interventional procedures. In this study, the area dose product(DAP/Gy·cm2) and fluoro time(min) according to the size of the aneurysm and the location of aneurysm were investigated according to insurance recognition regulations aneurysm classification cerebral aneurysm coil embolization. According to the research method, classification according to the size and location of the aneurysm is first, the size of the aneurysm is divided into less than 4mm, more than 4mm to less than 8mm, and more than 8mm, and second, the dose to the area based on the location site (DAP/Gy·cm2) and fluoro time(min) based on the location site were observed. As a result, the location of the cerebral aneurysm procedure was found to be the Paraclinoid site. During cerebral aneurysm coil embolization, the area dose was 107 Gy·cm2 and fluoro time was 47.41 minutes, showing lower results than domestic studies, and when comparing the area dose product with foreign studies, the area dose product results were similar to that of Turkey and Saudi Arabia. It is expected that it can be used as an objective analysis indicator to establish diagnostic reference levels (DRLs) and patient radiation defense guidelines according to the size of cerebral aneurysm and location of cerebral aneurysm procedures during interventional procedures.

Transvenous occlusion of patent ductus arteriosus using an embolization coil in a Maltese dog

  • Lee, Seung-Gon;Moon, Hyeong-Sun;Choi, Ran;Hyun, Changbaig
    • Korean Journal of Veterinary Research
    • /
    • v.47 no.4
    • /
    • pp.461-467
    • /
    • 2007
  • A 6-year-old female Maltese dog (body weight 2.0 kg) was referred to the Veterinary Teaching Hospital, Kangwon National University with primary complaints including exercise intolerance and heart murmur. Based on clinical and diagnostic findings including grade V/VI left basal continuous murmur, bounding femoral pulsation, left ventricular enlargement pattern in electrocardiogram, cardiomegaly with aortic bulging on the thoracic radiography, and shunt flow between aorta and pulmonary artery on the echocardiography, the dog was diagnosed as the left-to-right patent ductus arteriosus. The patent ductus arteriosus was successfully treated by lodging a single embolization coil with transjugular approach.

Safety and Efficacy of Flow Diverter Therapy for Unruptured Intracranial Aneurysm Compared to Traditional Endovascular Strategy : A Multi-Center, Randomized, Open-Label Trial

  • Kim, Junhyung;Hwang, Gyojun;Kim, Bum-Tae;Park, Sukh Que;Oh, Jae Sang;Ban, Seung Pil;Kwon, O-Ki;Chung, Joonho;Committee of Multicenter Research, Korean Neuroendovascular Society,
    • Journal of Korean Neurosurgical Society
    • /
    • v.65 no.6
    • /
    • pp.772-778
    • /
    • 2022
  • Objective : Endovascular treatment of large, wide-necked intracranial aneurysms by coil embolization is often complicated by low rates of complete occlusion and high rates of recurrence. A flow diverter device has been shown to be safe and effective for the treatment of not only large and giant unruptured aneurysms, but small and medium aneurysms. However, in Korea, its use has only recently been approved for aneurysms <10 mm. This study aims to compare the safety and efficacy of flow diversion and coil embolization for the treatment of unruptured aneurysms ≥7 mm. Methods : The participants will include patients aged between 19 and 75 years to be treated for unruptured cerebral aneurysms ≥7 mm for the first time or for recurrent aneurysms after initial endovascular coil embolization. Participants assigned to a flow diversion cohort will be treated using any of the following devices : Pipeline Flex Embolization Device with Shield Technology (Medtronic, Minneapolis, MN, USA), Surpass Evolve (Stryker Neurovascular, Fremont, CA, USA), and FRED or FRED Jr. (MicroVention, Tustin, CA, USA). Participants assigned to a coil embolization cohort will undergo traditional endovascular coiling. The primary endpoint will be complete occlusion confirmed by cerebral angiography at 12 months after treatment. Secondary safety outcomes will evaluate periprocedural and post-procedural complications for up to 12 months. Results : The trial will begin enrollment in 2022, and clinical data will be available after enrollment and follow-up. Conclusion : This article describes the aim and design of a multi-center, randomized, open-label trial to compare the safety and efficacy of flow diversion versus traditional endovascular treatment for unruptured cerebral aneurysms ≥7 mm.

A Case of a Dieulafoy Lesion Treated using Coil Embolization in a Child (코일 색전술로 치료한 소아 Dieulafoy 병변 1예)

  • Jung, Ji-Mi;Song, Min-Seob;Chi, Geun-Ha;Bae, Jae-Ik;Park, Ao-Whan
    • Pediatric Gastroenterology, Hepatology & Nutrition
    • /
    • v.10 no.2
    • /
    • pp.193-196
    • /
    • 2007
  • A dieulafoy lesion, which is an unusual cause of gastrointestinal bleeding that can be fatal in children. Dieulafoy lesions are characterized by an abnormally large eroded submucosal artery that is commonly located in the lesser curvature of the proximal stomach. In most cases, permanent hemostasis is achieved by endoscopic epinephrine injection, however, some patients require other endoscopic treatment modalities, embolization or surgery. We report here a case of a Dieulafoy lesion in an 11-year-old boy who had recurrent bleeding from the lesion in the duodenal bulb after endoscopic epinephrine injection and surgical ligation, that was successfully treated using coil embolization.

  • PDF

Intraaneurysmal Blood Flow Changes for the Different Coil Locations (코일 위치에 따른 동맥류 내부 혈류유동의 변화)

  • 이계한;정우원
    • Journal of Biomedical Engineering Research
    • /
    • v.25 no.4
    • /
    • pp.295-300
    • /
    • 2004
  • Coil embolization technique has been used recently to treat cerebral aneurysms. When a giant or a multilobular aneurysm are treated by roils, filling an aneurysm sac completely with coils is difficult and partial blocking of an aneurysm sac is inevitable. Blood flow characteristics, which nay affect the embolization process of an aneurysm sac, are changed by the locations of coils for the Partially blocked aneurysms. Blood flow fields are also influenced by the geometry of a parent vessel. In order to suggest the coil locations effective for aneurysm embolization, the blood flow fields of lateral aneurysm models were analyzed for the different coil locations and parent vessel geometries. Three dimensional pulsatile flow fields are analyzed by numerical methods considering non-Newtonian viscosity characteristics of blood. Flow rate into the aneurysm sac (inflow rate) and wall shear stress, which are suspected as flow dynamic factors influencing aneurysm embolization, are also calculated. Inflow rates were smaller and the low wall shear stress zones were larger in the neck blocked models compared to the dome blocked models. Smaller inflow and larger low wall shear stress zones in the distal neck blocked model imply that the distal neck should be the effective coil locations for aneurysm embolization.

A Case of Bronchial Artery Aneurysm Demonstrating Hilar Mass (폐문부 종괴로 관찰된 기관지 동맥류 1예)

  • Hong, Seong-Ah;Ha, Tae-Hoon;Lyu, Ji-Won;Kim, Yang-Ki;Lee, Young-Mok;Kim, Ki-Up;Uh, Soo-taek;Noh, Hyung-Jun;Kim, Yong-Jae;Goo, Dong-Erk
    • Tuberculosis and Respiratory Diseases
    • /
    • v.62 no.1
    • /
    • pp.62-66
    • /
    • 2007
  • A bronchial artery aneurysm is a rare condition, which needs optimal treatment due to the possibility of a life-threatening hemorrhage by rupture. The surgical removal of the aneurysm is the standard treatment. However, there are a few reports of coil embolization with a transcatheter. A 69 year-old man was referred for a further evaluation of a mass in the right hilum on chest radiography. He denied any respiratory symptoms. A chest CT scan showed a $3{\times}3{\times}4.5cm$ sized vascular mass with strong contrast enhancement on the right hilar area that originated from the bronchial artery. On the angiogram, the bronchial artery originated from the descending thoracic aorta at the T8 level. A bronchial artery aneurysm was catheterized selectively. and embolized successfully with a coil. After coil embolization, the selective bronchial arteriography confirmed complete occlusion. We report this case of bronchial aneurysm that was treated successfully with coil embolization.

A Case of Rasmussen Aneurysm Treated by Pulmonary Arterial Embolization (폐동맥색전술로 치료된 Rasmussen 동맥류 1예)

  • Park, Sung-Oh;Ko, Hyuk;Kim, Su-Hee;Park, Wan;Lee, Deck-Hee;Ryul, Dae-Sik;Jung, Bock-Hyun
    • Tuberculosis and Respiratory Diseases
    • /
    • v.51 no.1
    • /
    • pp.53-58
    • /
    • 2001
  • A 42 year-old male with a history of multidrug-resistant pulmonary tuberculosis suddenly developed massive hemoptysis. Embolization of a bronchial artery branch and the collateral systemic arteries did not resolve the recurrent bleeding. Spiral computerized tomography(spiral CT) of the chest showed contrast enhanced nodules within a large cavity at the left lower lobe in the arterial phase suggesting a Rasmussen aneurysm. A pulmonary angiogram showed abnormal vascular nodules at that site. Coils were deployed at both the proximal and distal vessels of this aneurysmal sac for embolization. Transcatheter arterial embolization is a safe and effective means of controlling bleeding from this pulmonary arterial pseudoaneurysm. Here we report a case of a Rasmussen aneurysm diagnosed by spiral CT, which was successfully treated by pulmonary arterial embolization with a coil.

  • PDF

Endovascular Treatment of "Kissing Aneurysms" at the Anterior Communicating Artery

  • Suh, Sang-Jun;Kang, Dong-Gee;Ryu, Kee-Young;Cho, Jae-Hoon
    • Journal of Korean Neurosurgical Society
    • /
    • v.44 no.3
    • /
    • pp.163-165
    • /
    • 2008
  • Kissing aneurysms are the rare type of multiple aneurysms. They are adjacent aneurysms of different origin arteries in the same region, which require great care in diagnosis and treatment. We report a case of kissing aneurysms at the anterior communicating artery (AcomA) which were treated by endovascular coil embolization.