• 제목/요약/키워드: Coil current

검색결과 997건 처리시간 0.029초

0.7MJ $\mu$SMES 코일의 특성 (Characteristics of the 0.7MJ $\mu$SMES Coil)

  • 김해종
    • 한국초전도저온공학회:학술대회논문집
    • /
    • 한국초전도저온공학회 1999년도 제1회 학술대회논문집(KIASC 1st conference 99)
    • /
    • pp.134-137
    • /
    • 1999
  • This paper describes the design, code of a $\mu$SMES device that we developed. The 0.7MJ $\mu$SMES coil was wound with high winding tension of about 14kbf/$mm^{2}$ in order to prevent wire motion from Lorentz force. This coil was charged up to a current of 1820A with a ramping rate of about 10A/s, where a quench occurred. This quench current is sbout 82% fo the coil critical current.

  • PDF

부분방전전류측정을 위한 로고스키코일의 적용에 관한 연구 (Study about the Application of Rogowski Coil for measuring Partial Discharge Current)

  • 이강원;윤성철;김명룡;백광선;나동희
    • 한국철도학회:학술대회논문집
    • /
    • 한국철도학회 2004년도 추계학술대회 논문집
    • /
    • pp.1378-1383
    • /
    • 2004
  • Rogowski coil is a kind of sensor for high amplitude and very short period current and suitable for the measurement of PD pulse. This paper have simulated the relations between PD signals and Rogowski coil which has its own equivalent circuit and investigated signals of Rogowski coil induced by PD pulse current. and compared with the PD signal obtained from conventional PD measuring system in accordance with IEC60270.

  • PDF

Numerical analysis on the critical current evaluation and the correction of no-insulation HTS coil

  • Bonghyun Cho;Jiho Lee
    • 한국초전도ㆍ저온공학회논문지
    • /
    • 제25권1호
    • /
    • pp.16-20
    • /
    • 2023
  • The International Electrotechnical Commission (IEC) 61788-26:2020 provides guidelines for measuring the critical current of Rare-earth barium copper oxide (REBCO) tapes using two methods: linear ramp and step-hold methods. The critical current measurement criterion, 1 or 0.1 μV/cm of electric field from IEC 61788-26 has been normally applied to REBCO coils or magnets. No-insulation (NI) winding technique has many advantages in aspects of electrical and thermal stability and mechanical integrity. However, the leak current from the NI REBCO coil can cause distortion in critical current measurement due to the characteristic resistance which causes the radial current flow paths. In this paper, we simulated the NI REBCO coil by applying both linear ramp and step-hold methods based on a simplified equivalent circuit model. Using the circuit analysis, we analyzed and evaluated both methods. By using the equivalent circuit model, we can evaluate the critical current of the NI REBCO coil, resulting in an estimation error within 0.1%. We also evaluate the accuracy of critical current measurement using both the linear ramp and step-hold methods. The accuracy of the linear ramp method is influenced by the inductive voltage, whereas the accuracy of the step-hold method depends on the duration of the hold-time. An adequate hold time, typically 5 to 10 times the time constant (τ), makes the step-hold method more accurate than the linear ramp method.

자속구속형 고온초전도 전류제한기의 인덕턴스 변화에 따른 전류제한 특성 분석 (Analysis of fault Current Limiting Characteristics due to Ratio of Inductances between Coil 1 and coil 2 in a Flux-lock Type SFCL)

  • 박충렬;임성훈;박형민;최효상;한병성
    • 한국전기전자재료학회논문지
    • /
    • 제18권9호
    • /
    • pp.856-862
    • /
    • 2005
  • A flux-lock type SFCL consists of two coils, which are wound in parallel each other through an iron core, and a HTSC thin film connected in series with coil 2. If the current of the HTSC thin film exceeds its critical current by the fault accident, the resistance generated of the HTSC thin film, and thereby the fault current can be limited by the impedance of the flux-lock type SFCL. The amplitude of fault current can be set by the impedance of the flux-lock type SFCL. In this paper, we investigated the variance of the limiting current due to the ratio of inductances between coil 1 and coil 2 in the flux-lock type SFCL through the computer simulations and short circuit tests. In addition, both the simulation results and experimental ones were compared each other. From the comparison of both the results, the simulation results agreed well with the experimental ones.

등가자화전류를 이용한 최적코일형상 설계방법 (Optimal Coil Configuration Design Methodology Using the Concept of Equivalent Magnetizing Current)

  • 김우철;김민태;김윤영
    • 대한기계학회논문집A
    • /
    • 제31권1호
    • /
    • pp.43-49
    • /
    • 2007
  • A new electric coil design methodology using the notion of topology optimization is developed. The specific design problem in consideration is to find optimal coil configuration that maximizes the Lorentz force under given magnetic field. Topology optimization is usually formulated using the finite element method, but the novel feature of this method is that no such partial differential equation solver is employed during the whole optimization process. The proposed methodology allows the determination of not only coil shape but also the number of coil turns which is not possible to determine by any existing topology optimization concept and to perform single coil strand identification algorithm. The specific applications are made in the design of two-dimensional fine-pattern focusing coils of an optical pickup actuator. In this method, the concept of equivalent magnetizing current is utilized to calculate the Lorentz force, and the optimal coil configuration is obtained without any initial layout. The method is capable of generating the location and shape of turns of coil. To confirm the effectiveness of the proposed method in optical pickup applications, design problems involving multipolar permanent magnets are considered.

저전류 영역에서 로고우스키 코일 특성 (Characteristics of Rogowski coil at Low Cutrrent Region)

  • 박정남;이강원;이청;김길수;박영국;강성화;임기조
    • 한국전기전자재료학회:학술대회논문집
    • /
    • 한국전기전자재료학회 2001년도 춘계학술대회 논문집 유기절연재료 전자세라믹 방전플라즈마 연구회
    • /
    • pp.47-50
    • /
    • 2001
  • Conventionally, air-cored Rogowski coil was designed for use as high alternating and transient current sensor without saturation caused by ferromagnetic material in its core. This paper investigated that Rogowski coil can be applied to low current measurement in 60Hz power line. Measured parameters R, L of coil were compared with theoretically calculated values. Output voltages crossed by Rogowski coil have shown some linearity according to input current(tens to thousands of amperes) passing through it. And also shielding effect for external noises was investigated for three cases.

  • PDF

Solid 모델링된 코일의 전류 밀도 분포 해석을 위한 새로운 방법 (A Novel Technique for Current Density Distribution Analysis of Solidly Modelled Coil)

  • 임창환;김홍규;정현교
    • 대한전기학회논문지:전기기기및에너지변환시스템부문B
    • /
    • 제49권7호
    • /
    • pp.483-487
    • /
    • 2000
  • The analysis of current distribution in a solidly modeled coil is very important for accurate of electric machines such as deflection yoke. In general, Modeling every coils is nearly impossible for analyzing magnetic field using the 3-D finite element method, so solidly modeled coil is usually used. Some methods have been developed for analyzing current distribution, but these methods have fatal disadvantages. The main disadvantages are that the methods cannot be applied to an arbitrary shaped coil and that they yield numerical errors. In this paper, a novel method for resolving the problems mentioned above is proposed. The new method is verified by the application to a test model and it shows a very accurate result.

  • PDF

Operational Characteristics of Flux-lock Type SFCL using Series Resonance

  • Lim, Sung-Hun;Han, Byoung-Sung;Choi, Hyo-Sang
    • Transactions on Electrical and Electronic Materials
    • /
    • 제6권4호
    • /
    • pp.159-163
    • /
    • 2005
  • We analyzed the fault current limiting characteristics of a flux-lock type $high-T_c$ super­conducting fault current limiter (HTSC-FCL) using series resonance between capacitor for series resonance and magnetic field coil which was installed in coil 3. The capacitor for the series resonance in the flux-lock type HTSC-FCL was inserted in series with the magnetic field coil to apply enough magnetic field into HTSC element, which resulted in higher resistance of HTSC element. However, the impedance of the flux lock type HTSC-FCL has started to decrease since the current of coil 3 exceeded one of coil 2 after a fault accident. The decrease in the impedance of the FCL causes the line current to increase and, if continues, the capacitor for the series resonance to be destructed. To avoid this operation, the flux-lock type HTSC-FCL requires an additional device such as fault current interrupter or control circuit for magnetic field. From the experimental results, we investigated the parameter range where the operation as mentioned above for the designed flux-lock type HTSC-FCL using series resonance occurred.

광CT 센서코일 끝단의 반사율이 전류측정에 미치는 영향 (Effects of reflective index of fiber sensor coil end on current measurement)

  • 박형준;김현진;송민호
    • 한국조명전기설비학회:학술대회논문집
    • /
    • 한국조명전기설비학회 2008년도 춘계학술대회 논문집
    • /
    • pp.74-77
    • /
    • 2008
  • We improved an efficiency of fiber-optic current transformer by using a metal-coated sensor coil. To reduce the linear birefringence, we used a length of spun fiber as sensor coil, and then used a flint glass fiber coil for comparison. To make the sensor coil in the reflection type, we used different reflection mirrors at the end of the sensor coil, such as a Faraday rotator mirror, a simple mirror, a metal-coated fiber end and a simple fiber end. From the experimental results, the linear error of current measurements were less than ${\sim}$ 0.2 % regardless of the mirror types. The metal-coated sensor was the most cost-effective considering the fabrication cost and the simple structure.

  • PDF

사병렬 초전도코일의 전류분류 측정을 위한 Rogowski 코일의 제작 및 특성 실험 (Design and test results of a Rogowski coil for measurement of current distribution characteristics in 4-parallel superconducting coils)

  • 조대호;양성은;김민재;안민철;박동근;배덕권;석복렬;고태국
    • 한국초전도ㆍ저온공학회논문지
    • /
    • 제9권3호
    • /
    • pp.37-40
    • /
    • 2007
  • Large critical current is one of the prerequisites for the design of superconducting electrical equipments with large power capacity. To enlarge the critical current. multiple parallel connection is inevitable. In multiple parallel superconducting coils. the difference in normal resistance of each shunt leads to unequal current distribution. which may yield burnout. Therefore. uniform current distribution is required for a stable operation of multiple parallel superconducting coils. In this paper, Rogowski coils were fabricated to measure each shunt current of a 4-parallel superconducting coil. Four Rogowski coils were installed at the copper bars, which are used as current leads in superconducting coils. As a result, linearity of the Rogowski coils was ascertained and coefficients of each coil, the ratio of voltage and current, were derived. The coefficients were compared with theoretically calculated values. Based on the coefficients, each shunt current was calculated in a 4-parallel superconducting coil, where uniform current. distribution was confirmed. This paper verified the feasibility of the fabricated Rogowski coils as well as operational stability of the 4-parallel superconducting coil in 77K.