• Title/Summary/Keyword: Coefficients of the variation

Search Result 1,075, Processing Time 0.041 seconds

Prediction of Evapotranspiration from Grape Vines in Suwon with the FAO Penman-Monteith Equation (FAO Penman-Monteith 공식을 이용한 수원지역 포도 수체 증발산량 예측)

  • Yun, Seok-Kyu;Hur, Seung-Oh;Kim, Seung-Heui;Park, Seo-Jun;Kim, Jeong-Bae;Choi, In-Myung
    • Korean Journal of Agricultural and Forest Meteorology
    • /
    • v.11 no.3
    • /
    • pp.111-117
    • /
    • 2009
  • Food and Agricultural Organization (FAO) Penman-Monteith (PM) equation is one of the most widely used equations for predicting evapotranspiration (ET) of crops. The ET rate and the base crop coefficients ($K_{cb}$) of the two different grape vines (i.e., Campbell Early and Kyoho) cultivated in Suwon were calculated by using the FAO PM equation. The ET rate of Campbell Early was $2.41\;mm\;day^{-1}$ and that of Kyoho was $2.22\;mm\;day^{-1}$ in August when the leaf area index was 2.2. During this period, the $K_{cb}$ of Campbell Early based on the FAO PM equation was on average 0.49 with the maximum value of 0.72. On the other hand, the $K_{cb}$ of Kyoho was averaged to be 0.45 with the maximum value of 0.64. The seasonal leaf area index for two grape cultivars was measured as 0.15 in April, 0.5 in May, 1.4 in June, 2.2 in July-September, and 1.5 in October. The $K_{cb}$ of Campbell Early showed a seasonal variation, changing from 0.03 in April to 0.11 in May, 0.31 in June, 0.49 in July-September, and 0.33 in October. The magnitudes and the seasonality of $K_{cb}$ of Kyoho were similar to those of Campbell Early.

Evaluation of Standardized Uptake Value applying EQ PET across different PET/CT scanners and reconstruction (PET/CT 장비와 영상 재구성 차이에 따른 EQ PET을 이용한 표준섭취계수의 평가)

  • Yoon, Seok Hwan;Kim, Byung Jin;Moon, Il Sang;Lee, Hong Jae
    • The Korean Journal of Nuclear Medicine Technology
    • /
    • v.22 no.1
    • /
    • pp.35-42
    • /
    • 2018
  • Purpose Standardized uptake value(SUV) has been widely used as a quantitative metric of uptake in PET/CT for diagnosis of malignant tumors and evaluation of tumor therapy response. However, the SUV depends on various factor including PET/CT scanner specifications and reconstruction parameter. The purpose of this study is to validate a EQ PET to evaluate SUV across different PET/CT systems. Materials and Methods First, NEMA IEC body phantom data were used to calculate the EQ filter for OSEM3D with PSF and TOF reconstruction from three different PET/CT systems in order to obtain EARL compliant recovery coefficients of each spheres. The Biograph true point 40 PET/CT images were reconstructed with a OSEM3D+PSF reconstruction, images of the Biograph mCT 40 and Biograph mCT 64 PET/CT scanners were reconstructed with a OSEM3D+PSF, OSEM3D+TOF, OSEM3D+PSF+TOF. Post reconstructions, the proprietary EQ filter was applied to the reconstruction data. Recovery coefficient can be estimated by ratio of measured to true activity concentration for spheres of different volume and coefficient variability(CV) value of RC for each sphere was compared. For clinical study, we compared SUVmax applying different reconstruction algorithms in FDG PET images of 61 patients with lung cancer using Biograph mCT 40 PET/CT scanner. Results For the phantom studied, the mean values of CV for OSEM3D, OSEM3D+PSF, OSEM3D+TOF and OSEM3D+PSF+TOF reconstructions were 0.05, 0.04, 0.04 and 0.03 respectively for RC. Application of the proprietary EQ filter, the mean values of CV for OSEM3D, OSEM3D+PSF, OSEM3D+TOF and OSEM3D+PSF+TOF reconstructions were 0.04, 0.03, 0.03 and 0.02 respectively for RC. Clinical study, there were no statistical significance of the difference applying EQ PET on SUVmax of 61 patients FDG PET image. (p=1.000) Conclusion This study indicates that CV values of RC in phantom were decreased after applying EQ PET for different PET/CT system and The EQ PET reduced reconstruction dependent variation in SUVs for 61 lung cancer patients, Therefore, EQ PET will be expected to provide accurate quantification when the patient is scanned on different PET/CT system.

The Evaluation of Radioimmunoassay kits for Insulin (Insulin 측정용 방사면역측정법 시약의 평가)

  • Shin, Yong Hwan;Kim, Yun Hyun;Lee, Il Kyu;Kim, Ji Young;Seok, Jae Dong;Shin, Suk Hee
    • The Korean Journal of Nuclear Medicine Technology
    • /
    • v.16 no.2
    • /
    • pp.149-155
    • /
    • 2012
  • Purpose : Serum insulin levels are useful indicator which of reflecting the function of insulin secretion in pancreatic ${\beta}$ cell and diagnosis of diabetes, differentiating the cause of impaired glucose tolerance. Insulin measurement kits have shown some differences in many ways such as test methods as well as quality control. The purpose of this study was to evaluate the diagnostic performance of seven manufacturing companies commercial kits. Materials and Methods : The values of insulin measured by three manufacturing companies (Biosource, Siemens, TFB) with 59 samples in August 2009 were compared with those measured by four manufacturing companies (Immunotech, Izotope, BNIBT, Cisbio) with 68 samples in December 2011. We evaluated precision, recovery rate, dilution test and correlation of serum insulin measurement using seven manufacturing company kits. Statistical program SPSS 12.0 was used for the verification of results. Results : The coefficients variation of the precision on all seven different kits were showed within 5.0%. Recovery rate of Biosource, Siemens, TFB kits on three different levels showed 94.2~103.7%, 99.0~104.6%, 99.7~107.6% respectively. Immunotech, Izotope, BNIBT, Cisbio were 93.5~99.1%, 91.4~99.1%, 99.2~131.0%, 84.8~102.3% respectively. There was strong correlation between the measurement of insulin by Biosource kit and that by two commercial kits, Siemens (R2=0.96), TFB (R2=0.99). There was good correlation between the measurement of insulin by TFB kit and that by three commercial kits, Immunotech (R2=0.97), Izotope (R2=0.96), Cisbio (R2=0.97). In the dilution test performed with more than 200 ${\mu}IU/ml$ high concentration samples, samples with diabetes correctly was measured in all seven manufacturing kits. However, as measured with insulinoma samples TFB, Siemens, Izotope, Cisbio kits were correctly measured, but Biosource and Immunotech kits were measured 47.4 ${\mu}IU/ml$, 72.3 ${\mu}IU/ml$, respectively. Conclusion : Serum Insulin radioimmunoassay kits were showed excellent precision, correlation and good recovery rate. However, some kits were not measured correctly in the high concentration insulin values. when selecting a kit should be considered many factors that cost effectiveness, compatible for automation equipment, high performance kit, the environment for each laboratory such as reaction time and reporting time.

  • PDF

Simultaneous Pesticide Analysis Method for Bifenox, Ethalfluralin, Metolachlor, Oxyfluorfen, Pretilachlor, Thenylchlor and Trifluralin Residues in Agricultural Commodities Using GC-ECD/MS (GC-ECD/MS를 이용한 농산물 중 Bifenox, Ethalfluralin, Metolachlor, Oxyfluorfen, Pretilachlor, Thenylchlor 및 Trifluralin의 동시 분석)

  • Ahn, Kyung Geun;Kim, Gi Ppeum;Hwang, Young Sun;Kang, In Kyu;Lee, Young Deuk;Choung, Myoung Gun
    • Korean Journal of Environmental Agriculture
    • /
    • v.37 no.2
    • /
    • pp.104-116
    • /
    • 2018
  • BACKGROUND: This experiment was conducted to establish a simultaneous analysis method for 7 kinds of herbicides in 3 different classes having similar physicochemical property as diphenyl ether(bifenox and oxyfluorfen), dinitroaniline (ethalfluralin and trifluralin), and chloroacetamide (metolachlor, pretilachlor, and thenylchlor) in crops using GC-ECD/MS. METHODS AND RESULTS: All the 7 pesticide residues were extracted with acetone from representative samples of five raw products which comprised apple, green pepper, Kimchi cabbage, hulled rice and soybean. The extract was diluted with saline water and directly partitioned into n-hexane/dichloromethane(80/20, v/v) to remove polar co-extractives in the aqueous phase. For the hulled rice and soybean samples, n-hexane/acetonitrile partition was additionally employed to remove non-polar lipids. The extract was finally purified by optimized Florisil column chromatography. The analytes were separated and quantitated by GLC with ECD using a DB-1 capillary column. Accuracy and precision of the proposed method was validated by the recovery experiment on every crop samples fortified with bifenox, ethalfluralin, metolachlor, oxyfluorfen, pretilachlor, thenylchlor, and trifluralin at 3 concentration levels per crop in each triplication. CONCLUSION: Mean recoveries of the 7 pesticide residues ranged from 75.7 to 114.8% in five representative agricultural commodities. The coefficients of variation were all less than 10%, irrespective of sample types and fortification levels. Limit of quantitation (LOQ) of the analytes were 0.004 (etahlfluralin and trifluralin), 0.008 (metolachlor and pretilachlor), 0.006 (thenylchlor), 0.002 (oxyfluorfen), and 0.02 (bifenox) mg/kg as verified by the recovery experiment. A confirmatory technique using GC/MS with selected-ion monitoring was also provided to clearly identify the suspected residues. Therefore, this analytical method was reproducible and sensitive enough to determine the residues of bifenox, ethalfluralin, metolachlor, oxyfluorfen, pretilachlor, thenylchlor, and trifluralin in agricultural commodities.

A Study on the Variation of Daily Urban Water Demand Based on the Weather Condition (기후조건에 의한 상수도 일일 급수량의 변화에 관한 연구)

  • Lee, Gyeong-Hun;Mun, Byeong-Seok;Eom, Dong-Jo
    • Water for future
    • /
    • v.28 no.6
    • /
    • pp.147-158
    • /
    • 1995
  • The purpose of this study is to establish a method of estimating the daily urban water demand using statistical model. This method will be used for the development of the efficient management and operation of the water supply facilities. The data used were the daily urban water use, the population, the year lapse and the weather conditions such as temperature, precipitation, relative humidity, etc. Kwangju city was selected for the case study area. The raw data used in this study were rearranged either by month or by season for the purpose of analysis, and the statistical analysis was applied to the data to obtain the regression model. As a result, the multiple linear regression model was developed to estimate the daily urban water use based on the seather condition. The regression constant and the model coefficients were determined for each month of a year. The accuracy of the model was within 3% of average error and within 10% of maximum error. The developed model was found to be useful to the practical operation and management of the water supply facilities.

  • PDF

Calculation and Monthly Characteristics of Satellite-based Heat Flux Over the Ocean Around the Korea Peninsula (한반도 주변 해양에서 위성 기반 열플럭스 산출 및 월별 특성 분석)

  • Kim, Jaemin;Lee, Yun Gon;Park, Jun Dong;Sohn, Eun Ha;Jang, Jae-Dong
    • Korean Journal of Remote Sensing
    • /
    • v.34 no.3
    • /
    • pp.519-533
    • /
    • 2018
  • The sensible heat flux (SHF)and latent heat flux (LHF) over Korean Peninsula ocean during recent 4 years were calculated using Coupled Ocean-Atmosphere Response Experiment (COARE) 3.5 bulk algorithm and satellite-based atmospheric-ocean variables. Among the four input variables (10-m wind speed; U, sea surface temperature; $T_s$, air temperature; $T_a$, and air humidity; $Q_a$) required for heat flux calculation, Ta and $Q_a$, which are not observed directly by satellites, were estimated from empirical relations developed using satellite-based columnar atmospheric water vapor (W) and $T_s$. The estimated satellite-based $T_a$ and $Q_a$ show high correlation coefficients above 0.96 with the buoy observations. The temporal and spatial variability of monthly ocean heat fluxes were analyzed for the Korean Peninsula ocean. The SHF showed low values of $20W/m^2$ over the entire areas from March to August. Particularly, in July, SHF from the atmosphere to the ocean, which is less than $0W/m^2$, has been shown in some areas. The SHF gradually increased from September and reached the maximum value in December. Similarly, The LHF showed low values of $40W/m^2$ from April to July, but it increased rapidly from autumn and was highest in December. The analysis of monthly characteristics of the meteorological variables affecting the heat fluxes revealed that the variation in differences of temperature and humidity between air and sea modulate the SHF and LHF, respectively. In addition, as the sensitivity of SHF and LHF to U increase in winter, it contributed to the highest values of ocean heat fluxes in this season.

Genetic and Environmental Effects on the Lactation Yield and Milk Compositions in Holstein Cow (Holstein종 유우(乳牛)의 비유량(泌乳量) 및 유조성분(乳組成分)에 미치는 유전(遺傳) 및 환경(環境)의 효과(效果))

  • Sang, Byong Chan;Seo, Kil Woong
    • Korean Journal of Agricultural Science
    • /
    • v.21 no.1
    • /
    • pp.45-53
    • /
    • 1994
  • This study was conducted to estimate the genetic and environmental effects on lactation yield and milk compositions in Holstein cows. The data analysis were the records of 159 cows rearing at Nation Animal Breeding Institute from 1990 to 1991. The least square means were estimated on milk and fat yield in lactation yield, and the percent of fat, protein, solids-not-fat and total solid in milk composition. The results obtained are summarized as follows: 1. The average yield of milk and fat in 305 days were $7,26.56{\pm}3,57.24$ and $254.65{\pm}44.94Kg$ and the percent of fat, protein, solids-not-fat and total solid were $3.69{\pm}0.43$, $3.32{\pm}0.41$, $9.15{\pm}0.49$ and $12.75{\pm}0.96$ and the coefficients of variation were 18.68, 17.64, 11.88 and 12.34% for milk yield, fat yield, fat percent and protein percent, respectively. 2. The effect of sires was highly significant at 1% level in milk and fat yield and fat percent, and significant at 5% level in protein and total solid percent. Among the sires, B, L and O sire were superior in milk yield with 7,571.22, 7,499.11 and 7,420.58 Kg, and A, F and K sire were superior in protein percent with 3.75, 3.64 and 3.65, respectively. 3. The effect of parity was highly significant at 1% level in milk yield, and significant at 5% level in fat yield. Among the parities, the 3rd parity was superior in milk and fat yield with 7,634.54 and 274.98 Kg, and the 4th and over was superior in fat and protein percent with 3.90 and 3.50, respectively. 4. The effect of calving seasons was highly significant at 1% level in milk yield, and significant at 5% level in fat yield, and the percent of fat, protein and total solid. Among the calving seasons, spring and winter were superior in milk yield with 7,310.31 and 7,364.57 Kg, also spring and winter were superior in protein percent with 3.68 and 3.52, respectively.

  • PDF

A STUDY OF DENTAL CROWDING AND ITS RELATIONSHIP TO MANDIBULAR INCISOR SHAPE BY MODEL ANALYSIS IN ADOLESCENTS (청소년 석고 모형 분석에 의한 하악절치 형태와 치아밀집의 상관관계에 관한 연구)

  • Surh, Jeong-Eun;Baik, Hyoung-Seon
    • The korean journal of orthodontics
    • /
    • v.25 no.5 s.52
    • /
    • pp.593-604
    • /
    • 1995
  • Mandibular incisor crowding is one of the most common features of malocclusion and is interesting characteristic in view of relapse and stability after orthodontic treatment. There are many potential factors in the etiology of lower anterior crowding. The tooth size variation is one of them, but biologic significance for the faciolingual width of the teeth has been overlooked. Peck and Peck reported that persons with ideal mandibular incisor alignment were shown to have incisor with smaller mesiodistal and larger faciolingual dimensions than persons with incisor crowding. On the basis of these findings they suggested MD/FL index as a clinical guideline for the assessment for lower incisor crowding. The present study was undertaken to examine the relationship between mandibular incisor crowding and mandibular incisor dimension, and determine their correlation with arch length discrepancy. 154 dental casts of people from 11 to 17 years of age were made, and were divided into normal group with irregularity index less than of 1, and crowding group with irregularity index greater than 1.The casts were measured and analyzed statistically. The results were as follows. 1. The mean mesiodistal width for mandibular incisor was larger in crowding group, and has significant difference in central inciosr measurement. There are no significant differences in the faciolingul width and MD/FL index. 2. Irregularity index has significant correlation coefficients with mesiodistal width and MD/FL index for mandibular incisor in crowding group, but no correlation with faciolingual width. It also has correlation with maxillary and mandibular arch length discrepancy, total tooth material, mandibular intercanine width, and mandibular inter first premolar width. 3. Upper and lower arch length discrepancy have significant correlation with mesiodistal width of mandibular incisor and overbite, but have no correlation with faciolingual width. Lower arch lenth discrepancy has significant correlation with MD/FL index for mandibular incisor and upper arch length discrepancy has correlation with MD/FL index for mandibular lateral incisor. 4. Significant differences were observed between normal and crowding group for the mandibular arch length discrepancy and overbite.

  • PDF

Spectrophotometric Determination of Soil Chemical Properties Using Soiltek® KA-P Spectrophotometer (Soiltek KA-P 분광광도계률 사용한 토양 화학적 성질의 분광학적 분석)

  • Hyun, Hae-Nam;Oh, Sang-Sil;Koo, Bon-Jun;Kang, Ho-Jun
    • Korean Journal of Soil Science and Fertilizer
    • /
    • v.33 no.2
    • /
    • pp.127-138
    • /
    • 2000
  • To enable rapid and convenient soil test, new soil analytical methods, which require only one instrument, UV/Vis spectrophotometer, were developed and named "Soiltek KA-P spectrophotometric methods". The Soiltek$^{(R)}$ KA-P spectrophotometric method was compared with standard method of RDA in analytical capability for soil chemical properties. Using the 78 soils collected from upland, paddy, orchard, and vinyl house soils, soil organic matter, exchangeable K, Ca, and Mg. CEC, available $SiO_2$, and nitrate were analyzed by the two methods. The color stability(ratio of the absorbance at elapsed time t to the absorbance at time t=0) of organic matter. Ca, Mg, and available $SiO_2$ decreased to about 2% within one hour. However, that of exchangeable K, CEC, and nitrate remained constant. The results obtained with Soiltek$^{(R)}$ KA-P spectrophotometric method showed highly significant correlation with those measured by the standard method of RDA($R^2$ >0.9501), in which the slopes were near unity of $1.0{\pm}0.05$. The standard deviation values of organic matter, exchangeable K, Ca, and Mg, CEC, available $SiO_2$, and nitrate were apparently lower than ${\pm}1.8gkg^{-1}$, ${\pm}0.05cmol^+kg^{-1}$, ${\pm}0.18cmol^+kg^{-1}$, and ${\pm}0.13cmol^+kg^{-1}$, ${\pm}1.0cmol^+kg^{-1}$, ${\pm}5.0mgkg^{-1}$, and ${\pm}10.0mgkg^{-1}$, respectively. All the measurements showed coefficients of variation of less than 7~17% and were within the confidence level of 95%, which means both the methods are precise. Considering the relative simplicity, low cost, precision and accuracy, the proposed Soiltek$^{(R)}$ KA-P spectrophotometric methods could be recommended as an alternative to standard method.

  • PDF

Development of Analytical Method for Fenoxycarb, Pyriproxyfen and Methoprene Residues in Agricultural Commodities Using HPLC-UVD/MS (HPLC-UVD/MS를 이용한 농산물 중 fenoxycarb, pyriproxyfen 및 methoprene의 분석법 확립)

  • Lee, Su-Jin;Kim, Young-Hak;Song, Lee-Seul;Hwang, Yong-Sun;Lim, Jung-Dae;Sohn, Eun-Hwa;Im, Moo-Hyeog;Do, Jung-Ah;Oh, Jae-Ho;Kwon, Ki-Sung;Lee, Joong-Keun;Lee, Young-Deuk;Choung, Myoung-Gun
    • The Korean Journal of Pesticide Science
    • /
    • v.15 no.3
    • /
    • pp.254-268
    • /
    • 2011
  • Fenoxycarb, pyriproxyfen and methoprene are juvenile hormone mimic insecticide. These insecticides have been widely used for mosquito, fly, scale insects, and Lepidoptera. The purpose of this study was to develop a simultaneous determination procedure of fenoxycarb, pyriproxyfen and methoprene residues in crops using HPLC-UVD/MS. These insecticide residues were extracted with acetone from representative samples of four raw products which comprised brown rice, apple, green pepper, and Chinese cabbage. The extract was diluted with saline water, and then n-hexane/dichloromethane partition was followed to recover these insecticides from the aqueous phase. Florisil column chromatography was additionally employed for final clean up of the extract. The analytes were quantitated by HPLC-UVD/MS, using a $C_{18}$ column. The crops were fortified with each insecticide at 3 levels per crop. Mean recovery ratios were ranged from 80.0 to 104.3% in four representative agricultural commodities. The coefficients of variation were less than 4.8%. Quantitative limit of fenoxycarb, pyriproxyfen, and methoprene was 0.04 mg/kg in crop samples. A HPLC-UVD/MS with selected-ion monitoring was also provided to confirm the suspected residues. The proposed simultaneous analysis method was reproducible and sensitive enough to determine the residues of fenoxycarb, pyriproxyfen and methoprene in the agricultural commodities.