• 제목/요약/키워드: Coefficient of resistance variation

검색결과 134건 처리시간 0.025초

A Study on the Quantitative Evaluation of Arc Stability in AC SMAW (교류 피복 아크 용접에 있어서 아크 안정성의 정량적 평가에 관한 연구)

    • Journal of Welding and Joining
    • /
    • 제16권4호
    • /
    • pp.125-135
    • /
    • 1998
  • The shielded metal arc welding (SMAW) by AC power source was performed to evaluate the arc stability by arc monitoring and analysing. In this study, the arc stability index was evaluated quantitatively by using he coefficient of resistance variation for welding time. This coefficient was obtained for the long time (20sec.) by analysing the waveforms of welding current, voltage and resistance. The coefficient was applied to indicate numerically the variation level of arc length and the degree of arc extinction. Using the coefficient of resistance variation in practical welding, the arc stability of the high titanium oxide electrode (KS E4313) turned out to be better than that of the low hydrogen electrode (KS E4316). In evaluating the skill level of welders by the coefficient, the horizontal fillet weaving welding became clear to be very discriminating because the higher level welder could weave in keeping constant arc length, but the lower level welder showed the characteristics of weaving with the unstable arc length. And it was confirmed that the welding defects as blow holes was formed when the arc stability index were high.

  • PDF

The Determination of Corrective Coefficient for Ground Resistance about Variation of Soil Resistivity by Field Test (현장실증시험에 의한 대지저항률별 접지저항 보정계수의 결정)

  • Shim, Keon-Bo;Kim, Kung-Chul;Lee, Hyung-Su;Park, Jae-Duck;Park, Sang-Man
    • Proceedings of the Korean Institute of IIIuminating and Electrical Installation Engineers Conference
    • /
    • 한국조명전기설비학회 2006년도 춘계학술대회 논문집
    • /
    • pp.288-292
    • /
    • 2006
  • Usually, equations that calculate ground resistance of earth electrode was already informed well by form of earth electrode. But, when apply on the spot because general expressions are very insufficient at point that calculate exact ground resistance value by variation of earth electrode, and constant value that corrective coefficient for ground resistance calculation is fixed regardless of change of the earth resistivity specially is presented, it is actuality that difficulty is. Therefore, in this study, about these problem, proposed corrective coefficient for calculation of ground resistance according to change of the earth resistivity.

  • PDF

An analysis on the solidification process of alloy casting with a contact resistance (접촉 열저항을 고려한 합금주조의 응고과정 해석)

  • Kim, W.S.;Lee, K.S.;Im, I.T.;Kim, K.S.
    • Transactions of the Korean Society of Mechanical Engineers B
    • /
    • 제21권1호
    • /
    • pp.57-67
    • /
    • 1997
  • The solidification process of Al 4.5%Cu alloy is numerically studied in the presence of contact resistance between mold and cast. Natural convection is considered in the liquid and mushy regions. The porosity approach is applied to the mushy zone modeling and linear variation of the solid fraction on the temperature is assumed. Results show that the mushy region is wider in the case with a contact resistance compared to the perfect contact condition. The temperature of the cast with a temporal variation in the contact heat transfer coefficient changes very rapidly in the early stage of the casting process compared to that with constant contact heat transfer coefficient.

Slip Resistance of Contaminants on the Floor for Variation of Viscosity (점도변화에 따른 바닥 오염물질의 미끄러짐 저항 특성)

  • Park, Jae-Suk;Oh, Whan-Sup
    • Journal of the Korean Society of Safety
    • /
    • 제27권5호
    • /
    • pp.185-189
    • /
    • 2012
  • While there is no standards on slip risk for contaminants on surface, glycerol is described in standard contaminant for measuring coefficient of friction(COF) and slip resistance such as ISO 13287. But that is just used to measure the slip resistance of surface materials and shoes not to evaluate the contaminant materials. Therefore the objective of this study was to find out the relationship between standard contaminant and the contaminants used usually at the workplaces. For this, some measurement criteria were acquired from the analysis based on biomechanics and kinetics of human gait during slips. The slip resistance according to viscosity of the contaminants was measured applying the criteria and slip probability was determined by the gait analysis. Some factors which should be considered when measuring the slip resistance were identified. The velocity, acceleration, contact time and contact pressure should be 1 m/sec, 10 $m/sec^2$, 350 kPa and less than 0.5sec respectively. The variation of viscosity according to temperature for working oils was different from that of standard contaminant. The static coefficient of friction (SCOF) of working oils was almost 0.5 times as large as the SCOF of standard contaminant. So it was assumed to be difficult to compare the contaminants at the workplaces with the glycerol as a standard contaminant for estimating the slip risk.

Fabrication and Reliability Properties of Thin film Resistors with Low Temperature Coefficient of Resistance (낮은 저항온도계수를 갖는 박막 저항체 제작 및 신뢰성 특성 평가)

  • Lee, Boong-Joo
    • Journal of the Korean Institute of Electrical and Electronic Material Engineers
    • /
    • 제20권4호
    • /
    • pp.352-356
    • /
    • 2007
  • The Ni/Cr/Al/Cu (51/41/4/4 wt%) thin films were deposited by using DC magnetron sputtering method for the application of the resistors having low TCR (temperature coefficients of resistance) and high resistivity from the former printed-results[3]. The TCR values measured on the as-deposited thin film resistors were less than ${\pm}10\;ppm/^{\circ}C$ and $-6{\sim}+1\;ppm/^{\circ}C$ after annealing and packaging process. The TCR values were $-3{\sim}1\;ppm/^{\circ}C$ (ratio of variation : about 0.02 %) and $-30{\sim}20\;ppm/^{\circ}C$ (ratio of variation : about $0.5{\sim}1\;%$) for the thermal cycling and PCT (pressure cooker test), respectively. It was confirmed that the reliability properties of the thin film resistor were good for electronic components.

Flexural Resistance Statistics of Composite Plate Girders (국내 생산 강재를 적용한 강합성 거더 휨저항강도의 통계적 특성)

  • Shin, Dong Ku;Kim, Chun Yong;Rho, Joon Sik;Park, Young Suk
    • Journal of Korean Society of Steel Construction
    • /
    • 제19권2호
    • /
    • pp.139-146
    • /
    • 2007
  • The objective of the present study is to provide statistical resistance statistics for steel-concrete composite plate girder sections under positive and negative moments. Statistical properties on yield strength, tensile strength, elongation, and fracture toughness of domestic structural steel products, gathered from an analysis of over 16,000 samples, were evaluated. Using the steel samples for the plate girder, the bias factor and the coefficient of variation of the ultimate flexural resistance for representative composite plate girder sections under positive and negative flexures were presented. In calculating the ultimate flexural resistance of the composite section, the moment curvature relationships were developed using the incremental load approach considering material nonlinearity for the steel girder. The predicted statistics can be used in the future for the efficient calibration of LRFD code.

Experimental Study on the Chloride Invasion Resistance Properties of Concrete Containing Mineral Admixtures (혼화재 혼입 콘크리트의 염화물 침투저항성에 관한 실험적 연구)

  • Yoo, Jae-Kang;Kim, Dong-Seuk;Lee, Sang-Soo
    • Proceedings of the Korean Institute of Building Construction Conference
    • /
    • 한국건축시공학회 2003년도 학술.기술논문 발표회
    • /
    • pp.43-48
    • /
    • 2003
  • This paper investigate that the effect of the concrete containing mineral admixtures(pozzolanic materials such as fly-ash, ground granulated blast-furnace slag, silica fume and meta kaolin) on the resistance properties to chloride ion invasion. The purposed testing procedure was applied to the concrete added mineral admixtures for 3~4 replacement ratios under W/B ratios ranged from 0.40 to 0.55. For the electrical migration test, Tang and Nilsson's method was used to estimate the migration coefficient of chloride ion. As a results, the W/B ratios, kinds of admixture and replacement ratios, water curing periods had a great effect on the migration coefficient of chloride ion, and the optimal replacement ratios of admixture had a limitation for each admixtures. Also, the addition of mineral admixtures by mass(replacement of OPC) enhanced the resistance of the mixture to chloride penetration compared with the plain concrete. The amount of acid soluble chloride ions and water soluble chloride ions were varied with the kinds of mineral admixtures. The compressive strength was shown related to the migration coefficient of chloride ion, the compressive strength increased with the decreasing migration coefficient of chloride ion. Below the 50MPa, the variation of migration coefficient of concrete added mineral admixtures was bigger than plain concrete.

  • PDF

Experimental Study on the Chloride Invasion Resistance Properties of Concrete Containing Mineral Admixtures (혼화재 혼입 콘크리트의 염화물 침투저항성에 관한 실험적 연구)

  • 유재강;김동석;이상수
    • Proceedings of the Korean Institute of Building Construction Conference
    • /
    • 한국건축시공학회 2003년도 학술.기술논문발표회
    • /
    • pp.43-48
    • /
    • 2003
  • This paper investigate that the effect of the concrete containing mineral admixtures(pozzaolanic materials such as fly-ash, ground granulated blast-furnace slag, silica fume and meta kaolin) on the resistance properties to chloride ion invasion. The purposed testing procedure was applied to the concrete added mineral admixtures for 3∼4 replacement ratios under W/B ratios ranged from 0.40 to 0.55. For the electrical migration test, Tang and Nilsson's method was used to estimate the migration coefficient of chloride ion. As a results, the W/B ratios, kinds of admixture and replacement ratios, water curing periods had a great effect on the migration coefficient of chloride ion, and the optimal replacement ratios of admixture had a limitation for each admixtures. Also, the addition of mineral admixtures by mass(replacement of OPC) enhanced the resistance of the mixture to chloride penetration compared with the plain concrete. The amount of acid soluble chloride ions and water soluble chloride ions were varied with the kinds of mineral admixtures. The compressive strength was shown related to the migration coefficient of chloride ion, the compressive strength increased with the decreasing migration coefficient of chloride ion. Below the 50MPa, the variation of migration coefficient of concrete added mineral admixtures was bigger than plain concrete.

  • PDF

A Study on the Development of Evaluation Method for the Output Characteristics of Welding Machine by 6$\sigma$ (6$\sigma$에 의한 용접기 출력특성의 평가기법 개발에 관한 연구)

  • 조상명;윤훈성
    • Journal of Welding and Joining
    • /
    • 제21권6호
    • /
    • pp.26-32
    • /
    • 2003
  • Arc welding process has indicated that it suffers from many flaws. It's because requirement of products is diverse and factors which affects the quality is also various. Therefore, in order to stabilize the welding process, it is important to choose a proper welding machine for the each process, and to evaluate the welding process capability of each machine. In this study, rational and simple index to evaluate the welding machine was set the coefficient of resistance variation through the arc stability examination such as spatter generation weight and bead configuration uniformity etc. And the method to evaluate the process capability index was developed by application of 6$\sigma$.

Study on Resistance of Icebreaker by Density Variation of Synthetic Ice in General Towing Tank (일반 수조에서의 합성 얼음의 밀도변화에 따른 쇄빙선의 저항특성 연구)

  • Lim, Tae-Wook;Kim, Moon-Chan;Chun, Ho-Hwan
    • Journal of Ocean Engineering and Technology
    • /
    • 제22권5호
    • /
    • pp.83-86
    • /
    • 2008
  • This paper deals with the experimental works for the correlations of ice resistance for icebreaker with synthetic(model) ice in general towing tank and with refrigerated ice in ice tank. In order to find out the correlation, the density variation is mainly focused in the present study. The model of Terry-Fox ice breaker has been used for the present correlation study because many data are available to be compared. According to the increase of density, the correlation becomes better quantitatively as well as qualitatively. Other parametric studies such as an ice size, a friction coefficient, a bending moment, etc., are also expected to be carried out to have better correlation in a near future. This research could be the basis for the possibility of resistance test using a synthetic ice in a general towing tank instead of an expensive ice tank.