• Title/Summary/Keyword: Coefficient of Variation(CV)

Search Result 245, Processing Time 0.037 seconds

Effects of supplementing distillers dried grains with solublesin the diet of lactating sows onvariation in the body weight of piglets

  • Song, Minho;Kim, Do-Myung;Choi, Kyu-Myung;Seo, Seongwon
    • Korean Journal of Agricultural Science
    • /
    • v.39 no.4
    • /
    • pp.555-559
    • /
    • 2012
  • Distillers dried grains with solubles (DDGS) is a by-product from processing corn to produce bio-ethanol, and it contains almost three times higher protein, fat, and fiber than corn. Intake of higher amount of nutrients originated from corn in lactating sows may contribute to changes in milk composition and thus alter the growth of suckling piglets. Therefore, the objective of this study was to evaluate effect of supplementing DDGS in the diet of lactating sows on variation in the body weight of piglets. A total of 50 sows with parities of 3 to 5 were usedand allottedinto one of four treatments which included 0 (CON), 10% (DDGS10), 20% (DDGS20), or 30% (DDGS30) DDGS in the diet. Diets were fed to sows during the whole lactation period. Individual body weights of piglets were measured within 24 h after farrowing and at weaning. No significant differences were observed inthe coefficient of variation (CV) for body weight of piglets within a litter after farrowing and at weaning among the treatments (p>0.05). There was, however, a tendency of decreases in the CV for body weight of piglets within a litter at weaning compared with that after farrowingin the DDGS10 and DDGS20 treatments. At weaning, the percentage of the number of piglets weighing less than 4.5 kg in DDGS20 (4.86%, 7 out of 144; p<0.05) or DDGS30 (5.04%, 6 out of 119; p=0.059) was lower than that in CON (12.41%; 17 out of 137) although this pattern was not observed in DDGS10. In conclusion, addition of DDGS in lactating sow diets improved piglet performance by reducing the number piglets weighing less than 4.5 kg.

Feasibility Study of Phosphor Particle Blended Hybrid Dosimeter for Quality Assurance in Radiation Therapy (Phosphor Particle 혼합형 Hybrid 선량계의 방사선치료 Quality Assurance에 대한 적용가능성 평가)

  • Shin, Yohan;Han, Moojae;Jung, Jaehoon;Cho, Heunglae;Park, Sungkwang
    • Journal of the Korean Society of Radiology
    • /
    • v.13 no.3
    • /
    • pp.333-338
    • /
    • 2019
  • In the field of radiotherapy, the Quality Assurance(QA) procedure to verify the safety of treatment is considered to be very important. However, due to various problems of the conventional dosimeters used for the QA, researches on these dosimeters have been actively carried out to replace them. In this study, to maximize the sensitivity by visible light(VL) emitted from phosphors, blended hybrid sensors were fabricated by blending various weight percent(wt%) of $Gd_2O_2S:Tb$ which is a phosphor with excellent fluorescence efficiency into $PbI_2$. Then, the electrical properties to high energy radiation from the blended sensors and the pure $PbI_2$ sensor were compared and evaluated. As a result of the sensitivity evaluation, the sensor of 3wt% showed the highest value with more than 40% difference from the other sensors, and gradual decreasing in sensitivity was observed with increasing wt% except for the sensor of 3wt%. Also, in the reproducibility evaluation, the pure $PbI_2$ sensor exhibited a large variation in coefficient of variation(CV)>0.015, while all the blended sensors showed CV<0.015.

Comparison of Analytical Methods for α-Quartz by FTIR and XRD (FTIR과 XRD를 이용한 α-Quartz 분석법 비교)

  • Kim, Boo-Wook;Lee, Jong-Seong;Choi, Byung-Soon
    • Journal of Environmental Health Sciences
    • /
    • v.35 no.2
    • /
    • pp.130-142
    • /
    • 2009
  • This study compared FTIR with XRD method for the analysis of quartz by % recovery, coefficient of variation (CV) and influence of the interference. the results were as the following. 1. In FTIR method, the coefficient of determination ($r^2$) was 0.9998 in a calibration curve of $695\;cm^{-1}$, and the limit of detection was $4.9{\mu}g/sample$. 2. The highest recovery was $799\;cm^{-1}$ (98.2%). 3. The CVpooled of the FTIR method was approximately 10% in three wave numbers. 4. The analysis of qualitative and quantitative for quartz is difficult with mixed cristobalite and iron oxide. 5. In XRD method with rotating sample holder and LynxEye detector, the coefficient of determination was 0.9996 in a calibration curve, and the limit of detection was $5.9{\mu}g/sample$. 6. The recovery and CV pooled were 104.3%, and 11 %, respectively. 7. In muffle furnace ashing, the quartz weight decreased to 34% when the maximum weight of the iron oxide was more than eight times. In conclusion, the accuracy (% recovery) and precision (CV) of FTIR and XRD method for analyzing $\alpha$-quartz were similar. FTIR method was a disadvantage for sample matrix because it indicates possibility of interference. However, XRD method distinguished specific crystalline forms of silica, and the majority of silicate minerals. In addition, XRD method recommend filter dissolution to pretreatment method.

Comparison of Rice Quality According to Agroclimatic Regions in Gyeoungbuk Province (경북 농업기후 지대별 쌀 품질 비교)

  • Lee Sun Hyung;Won Jong Gun;Choi Jang Soo;Ahn Duok Jong;Choi Ky Yeon;Lee Woo Gyeong;Park So Deuk;Son Jae Keun
    • KOREAN JOURNAL OF CROP SCIENCE
    • /
    • v.50 no.spc1
    • /
    • pp.94-98
    • /
    • 2005
  • This study was carried out to provide the geographic information based on the distribution of rice qualities and palatability in Gyeoungbuk province of Korea. The rice grain quality and environmental factors were analyzed using 513 sampling sites based on different five-agroclimtic regions of Gyeoungbuk province during three years from 2002 to 2004. In rice grain quality characteristics, the average palatability was low in South eastern coastal and Tabaek semi alpine regions as $67.6\~68.3$ and the coefficient of variation (CV) was relatively high as $6.2\~7.4\%$. The average head rice rates were low in South and Central eastern coastal regions as $87.3\~88.2\%$ and CV was high as $8.2\~8.3\%$. The average protein content was high in Central eastern coastal regions as $8.0\%$ and CV was high as $8.2\~8.3\%$. In case of palatability, the variation was differed clearly between high and low agroclimatic regions; it means that it is possible to divide the same agroclimatic region of high CV into two or three areas by CV of palatability. As the results of subdividing each existing agroclimatic regions based on the palatability, the variation of grain quality characteristics was become lower than that of existing five-agroclimatic regions. Therefore, the re-establishing of agroclimatic region based on rice grain quality was very important for precise cultivation for rice.

Analysis of Stability on Single-leg Standing by Wearing a Head Mounted Display

  • Woo, Byung Hoon
    • Korean Journal of Applied Biomechanics
    • /
    • v.27 no.2
    • /
    • pp.149-155
    • /
    • 2017
  • Objective: The purpose of this study was to investigate the effects of three visual conditions (eyes opened, eyes closed, and wearing of a head mounted display [HMD]) on single-leg standing through kinematics and kinetic analysis. Method: Twelve college students (age: $24.5{\pm}2.6years$, height: $175.0{\pm}6.4cm$, weight: $69.2{\pm}5.1kg$) participated in this study. The study method adopted three-dimensional analysis with six cameras and ground reaction force measurement with one force plate. The analysis variables were coefficient of variation (CV) of the center of body mass, head movement, ground reaction force, and center of pressure, which were analyzed using one-way analysis of variance with repeated measures according to visual conditions. Results: In most cases, the results of this study showed that the CV was significantly higher in the order of HMD wearing, eyes closed, and eyes opened conditions. Conclusion: Our results indicated that body sway was the largest in the HMD wearing condition, and the risk of falling was high owing to the low stability.

Short Term Sensor's Drift Analysis and Compensation Using Internal Normalization (내부 최적화를 이용한 화학 센서의 단기 드리프트 분석 및 보정)

  • Jeon, Jin-Young;Baek, Jong-Hyun;Byun, Hyung-Gi
    • Journal of Sensor Science and Technology
    • /
    • v.24 no.4
    • /
    • pp.270-273
    • /
    • 2015
  • One of the main problems when working the chemical sensor is the lack of repeatability and reproducibility of the sensor response. If the problem is not properly taken into consideration, the stability and reliability of the system using chemical sensors would be decreased. In this paper we analyzed the sensor's drift of short term and proposed a compensation method for reducing the effects of the drift in order to improve the stability and the reliability of the chemical sensor. The sensor drift was analyzed by a trend line graph and CV(coefficient of variation) was used to quantify. And we compensated for the drift by using the internal normalization. As a result it was found that the value of CV was decreased after compensation.

Significant Parameters for Assessing Soil Contaminant-Leaching to Groundwater and Determining Soil Sample Size in Field Survey

  • Jeong, Seung-Woo;An, Youn-Joo
    • Environmental Engineering Research
    • /
    • v.13 no.2
    • /
    • pp.73-78
    • /
    • 2008
  • For a given soil-contaminated site, a level of soil contamination is characterized and decisions on risk may be made from the risk assessment. The study evaluated critical design factors for the determination of sample size in the sampling design plan and the assessment of soil contaminant- leaching to groundwater. Two variables, the minimum relative detectable difference (T) and coefficient of variation (CV) were evaluated for the sample size determination. The minimum number of samples can be appropriately determined by CV under a T value greater than or equal to 0.2. Soil-contaminant leaching to groundwater was evaluated by using the Soil Screening Level equation of U.S. Environmental Protection Agency and the Risk Based Screening Level equation of American Society for Testing and Materials, with the same input parameters. The groundwater concentrations estimated from soil contaminant concentrations were significantly affected by the Darcy velocity of groundwater and the organic content of soil.

Comparison of Subsampling Error Associated with Analysis of Explosive Compounds in Soil (화약물질 오염토양의 부시료 제조방법에 따른 오차 비교)

  • Bae, Bumhan
    • Journal of Soil and Groundwater Environment
    • /
    • v.22 no.6
    • /
    • pp.57-65
    • /
    • 2017
  • Six soil subsampling methods were evaluated with explosive compounds-contaminated soils to quantify the variance associated with each method. The methods include modified grab sampling, simplified ripple splitting, fractional shoveling, coning & quatering, degenerate fractional shoveling, and rolling & quatering. All the methods resulted in significantly lower CV (coefficient of variation) of 1~5%, compared to common grab sampling that gave 8~98% of CV, possibly due to the reduction of grouping and segregation errors described by Gy sampling theory. Among the methods, simplified ripple splitting tends to result in lower explosive compounds concentrations, while the rolling & quatering gave the opposite result. Fractional shoveling method showed the least variance and the highest reproducibility in the analysis.

A Study on The Assessment Method of Gait Analysis for Ankle Assembly Using Ground Reaction Force (지면반발력을 이용한 인공족관절의 보행평가 기법에 관한 연구)

  • Kim Sung Min;Kim Sung Jae;Bae Ha Suk;Choi Byoung Cheol
    • Journal of the Korean Society for Precision Engineering
    • /
    • v.22 no.5 s.170
    • /
    • pp.197-204
    • /
    • 2005
  • In this study, ground reaction force(GRF), absolute symmetry index(ASI) and coefficient of variation(CV) of fixed, single-axis and multi-axis prosthetic ankle assemblies were investigated to show the biomechanical evaluation for above knee amputees. In the experiments, 37 normal male volunteers, two male and two female AK amputees were tested with fixed, single-axis and multi-axis prosthetic ankle assembly. A gait analysis was carried out to derive the ratio of GRF to weight as the percentage of total stance phase for ten points. The results showed that fixed-axis ankle was superior to the other two ankle assemblies for the characteristic of forwarding and breaking forces. Multi-axis ankle was relatively superior to the other two ankle assemblies for gait balancing and movement of the center for mass. single-axis ankle was relatively superior to the other two ankle assemblies for CV and ASI of GRF.

Genetic Aspects of Persistency of Milk Yield in Boutsico Dairy Sheep

  • Kominakis, A.P.;Rogdakis, E.;Koutsotolis, K.
    • Asian-Australasian Journal of Animal Sciences
    • /
    • v.15 no.3
    • /
    • pp.315-320
    • /
    • 2002
  • Test-day records (n=13677) sampled from 896 ewes in 5-9 (${\mu}$=7.5) monthly test-days were used to estimate genetic and phenotypic parameters of test-day yields, lactation milk yield (TMY), length of the milking period (DAYS) and three measures of persistency of milk yield in Boutsico dairy sheep. Τhe measures of persistency were the slope of the regression line (${\beta}$), the coefficient of variation (CV) of the test-day milk yields and the maximum to average daily milk yield ratio (MA). The estimates of variance components were obtained under a linear mixed model by restricted maximum likelihood. The heritability of test-day yields ranged from 0.15 to 0.24. DAYS were found to be heritable ($h^2$=0.11). Heritability estimates of ${\beta}$, CV and MA were 0.15, 0.13, 0.10, respectively. Selection for maximum lactation yields is expected to result in prolonged milking periods, high rates of decline of yields after peak production, variable test-day yields and higher litter sizes. Selection for flatter lactation curves would reduce lactation yields, increase slightly the length of the milking period and decrease yield variation as well as litter size. The most accurate prediction of TMY was obtained with a linear regression model with the first five test-day records.