• Title/Summary/Keyword: Coefficiency of measurement methods

Search Result 3, Processing Time 0.019 seconds

Analytical method for analyzing formaldehyde using 2, 4-DNPH and gas chromatography/FID, NPD (2,4-DNPH와 가스크로마토그래프를 이용한 포름알데히드 분석방법)

  • Jeong, Jee Yeon;Park, Seung Hyun;Yi, Gwang Yong;Oh, Se Min
    • Journal of Korean Society of Occupational and Environmental Hygiene
    • /
    • v.10 no.1
    • /
    • pp.126-146
    • /
    • 2000
  • To develop and evaluate formaldehyde measurement method using 2,4-dinitro-phenylhydrazine (2,4-DNPH) coated sampler and gas chromatography, laboratory test and field test were conducted. Results of this study are as follows. Limit of detection(LOD) of measurement methods, HPLC-UVD, GC-NPD and GC-FID, is $0.008{\mu}g/m{\ell}$ $0.060{\mu}g/m{\ell}$, $0.472{\mu}g/m{\ell}$ respectively. Coefficiency of measurement methods, HPLC-UVD, GC-NPD and GC-FID, is 0.008, 0.009, 0.020 respectively. Desorption efficiency of sep-pak xposure aldehyde sampler and sorbent sample tube is 1.05(range : 0.99 - 1.12), 1.02(range : 0.99 - 1.06) respectively. Samples of sorbent sample tube and sep-pak xposure aldehyde sampler turned out to be stored at refrigerator, according to storage test results. Measurement methods of HPLC-UVD, GC-NPD, GC-FID, according to results of precision for the combined sampling and analytical procedure, became acceptable to OSHA evaluation standard. Field test using exposure chamber met the NIOSH overall uncertainty recommendation(less than 25%). Overall uncertainty of Sepak-HPLC(UVD), Tube-GC(NPD), Tube-GC(FID) is 11.0% - 17.0%. Consequently gas chromatography(GC-NPD, GC-FID) and high performance liquid chromatography(EPA TO-11) using 2,4-DNPH coated sampler for formaldehyde measurement turned out to be suitable to measure personal formaldehyde exposure at workplaces.

  • PDF

A comparative study between data obtained from conventional lateral cephalometry and reconstructed three-dimensional computed tomography images

  • Oh, Suseok;Kim, Ci-Young;Hong, Jongrak
    • Journal of the Korean Association of Oral and Maxillofacial Surgeons
    • /
    • v.40 no.3
    • /
    • pp.123-129
    • /
    • 2014
  • Objectives: The aim of this study was to verify the concordance of the measurement values when the same cephalometric analysis method was used for two-dimensional (2D) cephalometric radiography and three-dimensional computed tomography (3D CT), and to identify which 3D Frankfort horizontal (FH) plane was the most concordant with FH plane used for cephalometric radiography. Materials and Methods: Reference horizontal plane was FH plane. Palatal angle and occlusal plane angle was evaluated with FH plane. Gonial angle (GA), palatal angle, upper occlusal plane angle (UOPA), mandibular plane angle (MPA), U1 to occlusal plane angle, U1 to FH plane angle, SNA and SNB were obtained on 2D cephalmetries and reconstructed 3D CT. The values measured eight angles in 2D lateral cephalometry and reconstructed 3D CT were evaluated by intraclass correlation coefficiency (ICC). It also was evaluated to identify 3D FH plane with high degree of concordance to 2D one by studying which one in four FH planes shows the highest degree of concordance with 2D FH plane. Results: ICCs of MPA (0.752), UOPA (0.745), SNA (0.798) and SNB (0.869) were high. On the other hand, ICCs of gonial angle (0.583), palatal angle (0.287), U1 to occlusal plane (0.404), U1 to FH plane (0.617) were low respectively. Additionally GA and MPA acquired from 2D were bigger than those on 3D in all 20 patients included in this study. Concordance between one UOPA from 2D and four UOPAs from 3D CT were evaluated by ICC values. Results showed no significant difference among four FH planes defined on 3D CT. Conclusion: FH plane that can be set on 3D CT does not have difference in concordance from FH plane on lateral cephalometry. However, it is desirable to define FH plane on 3D CT with two orbitales and one porion considering the reproduction of orbitale itself.

Relationship between the depth of cingulate sulcus on neonatal high resolution cranial ultrasound and gestational age (신생아 고해상 뇌 초음파검사에서 대상고랑의 깊이와 재태기간과의 관계)

  • Choi, Young Chil;Choi, Jin Yong;Lee, Jung Hwa
    • Clinical and Experimental Pediatrics
    • /
    • v.52 no.10
    • /
    • pp.1136-1139
    • /
    • 2009
  • Purpose:It is critical that the exact gestational age of a newborn baby, especially premature baby, be determined to evaluate the status of a disease and its management and to estimate the prognosis of a patient. This study aimed to investigate an easy and accurate method to estimate gestational age on cranial ultrasound, requiring minimal additional time and equipment. Methods:A high-resolution coronal sonographic image was obtained via the anterior fontanel with a 5-12 Mhz linear probe after the usual cranial sonographic examination. We measured the depth of cerebral hemisphere, thickness of corpus callosum, and depth of cingulate sulcus and obtained the correlations between these factors and gestational age. Results:Depth of cingulate sulcus had the highest correlation coefficiency with gestational age (r=0.878, P=0.000). All the cases, except for 2 cases, had a gestational age of more than 37 weeks, when the depths of cingulate sulcus were more than 0.55 cm, and had a gestational age less than 34 weeks, when the depths of cingulate sulcus were less than 0.35 cm. Conclusion:Measurement of the depth of cingulate sulcus was a simple and accurate method to estimate the gestational age on cranial ultrasound. The gestational age is more than 37 weeks, when the depth of cingulate sulcus is more than 0.55 cm, and is less than 34 weeks, when the depth of cingulate sulcus is less than 0.35 cm.