• Title/Summary/Keyword: CodeX

Search Result 428, Processing Time 0.027 seconds

Estimation of Chemical Speciation and Temporal Allocation Factor of VOC and PM2.5 for the Weather-Air Quality Modeling in the Seoul Metropolitan Area (수도권 지역에서 기상-대기질 모델링을 위한 VOC와 PM2.5의 화학종 분류 및 시간분배계수 산정)

  • Moon, Yun Seob
    • Journal of the Korean earth science society
    • /
    • v.36 no.1
    • /
    • pp.36-50
    • /
    • 2015
  • The purpose of this study is to assign emission source profiles of volatile organic compounds (VOCs) and particulate matters (PMs) for chemical speciation, and to correct the temporal allocation factor and the chemical speciation of source profiles according to the source classification code within the sparse matrix operator kernel emission system (SMOKE) in the Seoul metropolitan area. The chemical speciation from the source profiles of VOCs such as gasoline, diesel vapor, coating, dry cleaning and LPG include 12 and 34 species for the carbon bond IV (CBIV) chemical mechanism and the statewide air pollution research center 99 (SAPRC99) chemical mechanism, respectively. Also, the chemical speciation of PM2.5 such as soil, road dust, gasoline and diesel vehicles, industrial source, municipal incinerator, coal fired, power plant, biomass burning and marine was allocated to 5 species of fine PM, organic carbon, elementary carbon, $NO_3{^-}$, and $SO_4{^2-}$. In addition, temporal profiles for point and line sources were obtained by using the stack telemetry system (TMS) and hourly traffic flows in the Seoul metropolitan area for 2007. In particular, the temporal allocation factor for the ozone modeling at point sources was estimated based on $NO_X$ emission inventories of the stack TMS data.

Development of the Reference Korean Female Voxel Phantom (한국인 기준여성 체적소형 모의체 개발)

  • Ham, Bo-Kyoung;Cho, Kun-Woo;Yeom, Yoen-Soo;Jeong, Jong-Hwi;Kim, Chan-Hyeong;Han, Min-Cheol
    • Journal of Radiation Protection and Research
    • /
    • v.37 no.1
    • /
    • pp.41-49
    • /
    • 2012
  • The objective of this study is for development of the reference Korean female phantom, HDRK-Woman. The phantom was constructed by adjusting a Korean woman voxel phantom to the Reference Korean data. The Korean woman phantom had been developed based on the high-resolution color slice images obtained from an adult Korean female cadaver. There were a total of 39 organs including the 27 organs specified in ICRP 103 for effective dose calculation. The voxel resolution of the phantom was $1.976{\times}1.976{\times}2.0619\;mm^3$ and the voxel array size is $261{\times}109{\times}825$ in the x, y and z directions. Then, the voxel resolution was changed to $2.0351{\times}2.0351{\times}2.0747\;mm^3$ for adjustment of the height and total bone mass of the phantom to the Reference Korean data. Finally, the internal organs and tissue were adjusted using in-house software program developed for 3D volume adjustment of the organs and tissue. The effective dose values of HDRK phantoms were calculated for broad parallel photon beams using MCNPX Monte Carlo code and compared with those of ICRP phantoms.

Comparison of Three Methods Assessing the Ergonomic Risks of Manual Lifting Tasks at Ship Engine Manufacturing Facilities (선박용 엔진 제조업 들기작업의 인간공학적 위험 평가를 위한 세 가지 방법 비교)

  • Kim, Sun Ja;Shin, Yong Chul;Kim, Boo Wook;Kim, Hyun Dong;Woo, Ji Hoon;Kang, Dongmug;Lee, Hyun Seok
    • Journal of Korean Society of Occupational and Environmental Hygiene
    • /
    • v.15 no.2
    • /
    • pp.104-113
    • /
    • 2005
  • A variety of ergonomic assessment methods of lifting tasks known as a major cause of work-related lower back pain have been used. But there is a limited information in choosing the most appropriate assessment method for a particular job and in finding out strengths and weakness of the methods. The purpose of this study was to assess and compare the ergonomic risks of lifting tasks in a marine diesel engine production industry by three lifting ergonomic assessment tools widely used: the National Institute for Occupational Safety and Health(NIOSH) Revised Lifting Equation(NLE), the Washington Administrative Code 296-62-0517(WAC), and the Snook Tables. Lifting index(weight of load/Recommended Weight Limit) of NLE($LI_{NLE}$) was above 1 at 34 tasks(75.6%) of a total number of 45 lifting tasks. LI of WAC($LI_{WAC}$) was above 1 at 11 tasks(24.4 %). LI of Snook Table($LI_{Snook}$) was above 1 at 29 tasks(64.4%). Thus, LI was high in orders of $LI_{NLE}$ > $LI_{Snook}$ > $LI_{WAC}$. There were significantly high correlations among three Lls(p<0.01). The correlation coefficients between $LI_{NLE}$and the other three Lls($LI_{WAC}$ and $LI_{Snook}$) were r=0.93 and r=0.88, respectively. The linear regression equations were y = 0.444x + 0.11(r=0.93) between $LI_{NLE}$ and $LI_{WAC}$, y = 0.93x + 0.008(r=0.88) between LI(NLE) and $LI_{Snook}$. The LI values by WAC was significantly lower than those by the other tools. The compared features, strength and limitation among these tools were described in this paper.

Review on asbestos analysis (석면 분석방법에 대한 고찰)

  • Ham, Seung hon;Hwang, Sung Ho;Yoon, Chungsik;Park, Donguk
    • Journal of Korean Society of Occupational and Environmental Hygiene
    • /
    • v.19 no.3
    • /
    • pp.213-232
    • /
    • 2009
  • This document was prepared to review and summarize the analytical methods for airborne and bulk asbestos. Basic principles, shortcomings and advantages for asbestos analytical instruments using phase contrast microscopy(PCM), polarized light microscopy(PLM), X-ray diffractometer (XRD), transmission electron microscopy(TEM), scanning electron microscopy(SEM) were reviewed. Both PCM and PLM are principal instrument for airborne and bulk asbestos analysis, respectively. If needed, analytical electron microscopy is employed to confirm asbestos identification. PCM is used originally for workplace airborne asbestos fiber and its application has been expanded to measure airborne fiber. Shortcoming of PCM is that it cannot differentiate true asbestos from non asbestos fiber form and its low resolution limit ($0.2{\sim}0.25{\mu}m$). The measurement of airborne asbestos fiber can be performed by EPA's Asbestos Hazard Emergency Response Act (AHERA) method, World Health Organization (WHO) method, International Standard Organization (ISO) 10312 method, Japan's Environmental Asbestos Monitoring method, and Standard method of Indoor Air Quality of Korea. The measurement of airborne asbestos fiber in workplace can be performed by National Institute for Occupational Safety and Health (NIOSH) 7400 method, NIOSH 7402 method, Occupational Safety and Health Administration (OSHA) ID-160 method, UK's Health and Safety Executive(HSE) Methods for the determination of hazardous substances (MDHS) 39/4 method and Korea Occupational Safety and Health Agency (KOSHA) CODE-A-1-2004 method of Korea. To analyze the bulk asbestos, stereo microscope (SM) and PLM is required by EPA -600/R-93/116 method. Most bulk asbestos can be identified by SM and PLM but one limitation of PLM is that it can not see very thin fiber (i.e., < $0.25{\mu}m$). Bulk asbestos analytical methods, including EPA-600/M4-82-020, EPA-600/R-93/116, OSHA ID-191, Laboratory approval program of New York were reviewed. Also, analytical methods for asbestos in soil, dust, water were briefly discussed. Analytical electron microscope, a transmission electron microscope equipped with selected area electron diffraction (SAED) and energy dispersive X-ray analyser(EDXA), has been known to be better to identify asbestiform than scanning electron microscope(SEM). Though there is no standard SEM procedures, SEM is known to be more suitable to analyze long, thin fiber and more cost-effective. Field emission scanning electron microscope (FE-SEM) imaging protocol was developed to identify asbestos fiber. Although many asbestos analytical methods are available, there is no method that can be applied to all type of samples. In order to detect asbestos with confidence, all advantages and disadvantages of each instrument and method for given sample should be considered.

INFLUENCE OF THE SHADE GUIDE DESIGN ON COLOR HATCHING (Shade guide의 형태가 색상 결정에 미치는 영향)

  • Park, Geol;Kim, Dong-Jun;Lee, Shee-Eun;Hwang, Yun-Chan;Oh, Won-Mann;Hwang, In-Nam
    • Restorative Dentistry and Endodontics
    • /
    • v.30 no.3
    • /
    • pp.170-177
    • /
    • 2005
  • This study was conducted in order to assess whether the form of the shade guide affects in deciding the color of the teeth using the shade guide Eight shade light cured composite resins (Esthet-X, Dentsply, Milford, USA) were used in this study. Shade guides including the model of maxillary central incisors, teeth-form shade guide, doughnut form shade guide, and shade guide with perforated gray shield were prepared with eight shade composite resins and provided the codes randomly After arranging the models of teeth, 19 dentists working at the clinic of the Dentistry of Chonnam University Hospital and 65 students of college of dentistry, Chonnnam University selected the shade guides corresponding to the color of each tooth on the gray board under the D$_{65}$ standard illuminant. Bl shade showed highest accuracy of about 95% among all shade guides of 3 forms applied to the test and regardless of observer, tooth form shade guide showed the highest accuracy (p < 0.05) , and the doughnut form showed the lowest accuracy (p < 0.05). At the time of deciding on the color of the teeth using the shade guides as a result of above, the forms of the shade guides can affect the accuracy, and it suggests that the development of the diversified forms of shade guides, which may obtain more accurate results, is required.

The Effect of the Replacement of Grinded Fly Ash according to Curing Temperature on Repair Mortar Based on Polymer Admixture (폴리머수지 기반 보수모르타르에서 양생온도에 따른 미분쇄된 플라이애시 치환율의 영향)

  • Sim, Jae-Il;Mun, Ju-Hyun;Yun, In-Gu;Jeon, Young-Su
    • Journal of the Korea institute for structural maintenance and inspection
    • /
    • v.19 no.4
    • /
    • pp.116-124
    • /
    • 2015
  • The objective of this study is to evaluate the effects of the replacement levels of grinded fly-ash on the repaired mortar based on a polymer. The main parameters are the curing temperature and replacement levels of grinded fly-ash. The curing temperature and the replacement levels of grinded fly-ash are varied at $40^{\circ}C$, $20^{\circ}C$ and $5^{\circ}C$, and between 0% and 35% of the total binder by weight, respectively. The flow in fresh mortar and compressive strengths according to ages, the relationship of stress-strain, elastic modulus and modulus rupture in hardened mortar, as well as scanning the electron microscopy and the X-ray diffraction of mortar, were measured, respectively. The test results showed that the flow, elastic modulus and modulus rupture are great in mortar specimens with 20~30% of the replacement levels of grinded fly-ash. In addition, compressive strengths according to ages were affected by the replacement levels of grinded fly-ash and the curing temperature indicated that the strength development ratio of mortar with 20% of the replacement levels of grinded fly-ash was greater than others. In the prediction of the compressive strength specified by the ACI 209 code, the strength development at an early and late age can be generalized by the functions of the replacement levels of grinded fly-ash and the curing temperature. In the analysis of scanning the electron microscopy and the X-ray diffraction, the number and intensity of peaks increased and the form of CSH gels on the surface of the particle of grinded fly-ash was observed.

Geocoding Scheme for Multimedia in Indoor Space Based on IndoorGML (IndoorGML을 활용한 실내공간 멀티미디어 위치 인코딩 방법)

  • Li, Ki Joune
    • Spatial Information Research
    • /
    • v.21 no.4
    • /
    • pp.35-45
    • /
    • 2013
  • Most multimedia contains location information whether they are implicit or explicitly, and which are very useful for several purposes. In particular, we may use location information in defining query conditions to retrieve relevant multimedia. For this reason, a number of works have been done to organize and retrieve geo-referenced multimedia data. However, they mostly focus on outdoor space where position is identified by (x, y, z) coordinates. In this paper, we focus on multimedia in an alternative space, indoor space, which differs from outdoor space in several aspects. First indoor space is considered as symbolic space, where location is identified by a symbolic code such as room number rather than coordinates. Second, topological information is a crucial element in providing indoor spatial information services. Third, indoor space is in more micro-scale than outdoor space, which influences on determining the visibility of cameras. Based on these different characteristics of indoor space, we survey the requirements of management systems of indoor geo-referenced multimedia. Then we propose a geo-coding scheme for multimedia in indoor space as an extension of IndoorGML, an OGC(Open Geospatial Consortium) candidate standard for indoor spatial information. We also present a prototype system called, IngC (INdoor Geo-Coding) developed to store and manage indoor geo-referenced multimedia.

Numerical Analysis of the Complex Permittivity of MWNT added Epoxy Depending on Agglomeration Size (에폭시 내부의 MWNT 응집 크기에 따른 복소유전율 변화의 해석적 관찰)

  • Shin, Jae-Hwan;Jang, Hong-Kyu;Choi, Won-Ho;Song, Tae-Hoon;Kim, Chun-Gon;Lee, Woo-Yong
    • Composites Research
    • /
    • v.27 no.5
    • /
    • pp.190-195
    • /
    • 2014
  • This paper predicts the complex permittivity of MWNT added epoxy depending on agglomeration by numerical analysis. 1wt% MWNT added epoxy specimen is prepared using 3-roll-mill method and its complex permittivity is measured in X-band (8.2~12.4 GHz) using freespace measurement system. The analytic model is comprised of cube epoxy and perfect sphere agglomeration. The complex permittivity of the agglomeration model is predicted by complex permittivity mixing rule using the measured complex permittivity of epoxy and 1 wt% MWNT added epoxy. Commercial electromagnetic analysis software, CST, is used to obtain S-parameter of the analytic model and MATLAB code is used to calculate complex permittivity from the S-parameter. It is confirmed that the complex permittivity increases when the agglomeration size decreases.

A Pilot Establishment of the Job-Exposure Matrix of Lead Using the Standard Process Code of Nationwide Exposure Databases in Korea

  • Ju-Hyun Park;Sangjun Choi;Dong-Hee Koh;Dae Sung Lim;Hwan-Cheol Kim;Sang-Gil Lee;Jihye Lee;Ji Seon Lim;Yeji Sung;Kyoung Yoon Ko;Donguk Park
    • Safety and Health at Work
    • /
    • v.13 no.4
    • /
    • pp.493-499
    • /
    • 2022
  • Background: The purpose of this study is to construct a job-exposure matrix for lead that accounts for industry and work processes within industries using a nationwide exposure database. Methods: We used the work environment measurement data (WEMD) of lead monitored nationwide from 2015 to 2016. Industrial hygienists standardized the work process codes in the database to 37 standard process and extracted key index words for each process. A total of 37 standardized process codes were allocated to each measurement based on an automated key word search based on the degree of agreement between the measurement information and the standard process index. Summary statistics, including the arithmetic mean, geometric mean, and 95th percentile level (X95), was calculated according to industry, process, and industry process. Using statistical parameters of contrast and precision, we compared the similarity of exposure groups by industry, process, and industry process. Results: The exposure intensity of lead was estimated for 583 exposure groups combined with 128 industry and 35 process. The X95 value of the "casting" process of the "manufacture of basic precious and non-ferrous metals" industry was 53.29 ㎍/m3, exceeding the occupational exposure limit of 50 ㎍/m3. Regardless of the limitation of the minimum number of samples in the exposure group, higher contrast was observed when the exposure groups were by industry process than by industry or process. Conclusion: We evaluated the exposure intensities of lead by combination of industry and process. The results will be helpful in determining more accurate information regarding exposure in lead-related epidemiological studies.

VLSI Array Architecture for High Speed Fractal Image Compression (고속 프랙탈 영상압축을 위한 VLSI 어레이 구조)

  • 성길영;이수진;우종호
    • The Journal of Korean Institute of Communications and Information Sciences
    • /
    • v.25 no.4B
    • /
    • pp.708-714
    • /
    • 2000
  • In this paper, an one-dimensional VLSI array for high speed processing of fractal image compression algorithm based the quad-tree partitioning method is proposed. First of all, the single assignment code algorithm is derived from the sequential Fisher's algorithm, and then the data dependence graph(DG) is obtained. The two-dimension array is designed by projecting this DG along the optimal direction and the one-dimensional VLSI array is designed by transforming the obtained two-dimensional array. The number of Input/Output pins in the designed one-dimensional array can be reduced and the architecture of process elements(PEs) can he simplified by sharing the input pins of range and domain blocks and internal arithmetic units of PEs. Also, the utilization of PEs can be increased by reusing PEs for operations to the each block-size. For fractal image compression of 512X512gray-scale image, the proposed array can be processed fastly about 67 times more than sequential algorithm. The operations of the proposed one-dimensional VLSI array are verified by the computer simulation.

  • PDF