• Title/Summary/Keyword: CodeEye

Search Result 51, Processing Time 0.021 seconds

Optical System Design for Real-Time 3-Dimension Ophthalmoscope (실시간 3차원 검안경의 광학설계)

  • Lee, Soak-Hee;Yang, Yun-Sik;Choe, Oh-Mok;Sim, Sang-Hyun;Doo, Ha-Young
    • Journal of Korean Ophthalmic Optics Society
    • /
    • v.8 no.1
    • /
    • pp.35-39
    • /
    • 2003
  • The display technology on the retina is the key role in inspecting the condition of the patients. 2-dimensional retina image is widely used in the eye examination as of today. Recently, 3-dimensional retina image ones have been introduced to this area, but the quality of the image is not fully satisfied to the operator. For the purpose of developing 3-D retina imaging instrument, the optimization of a 3-D retina imaging system using Code-V tool was investigated in this thesis. He-Ne laser having the wavelength 632.8 nm was used to make a power source to detect the retina. Several lenses and mirrors installed on sledge which were developed to perform focus control on 3-D device were designed to make a beam focusing and direct line. Polygon scanner having 24 mirror facets and galvanometer making tilting movement were utilized to make a 2-D laser plane. Also, design of eye ball had been fulfilled to see the focus of the 2-D plane. Reflected ray from retina detected on the sensor array with the same path. All cognitive components were optimized for aberration correction in order to focus on retina. Results of optimization were compared to those of initial designed optics system. On the basis of above results, the result of third aberration has been corrected to stable values to the optical system. MTF evaluating the resolution of an image has been closely correlated to the diffraction limit and PSF indicating the strength distribution of an image has shown the SR value as 0.9998 having high performance. The possibility of new and powerful 3-D retina image instrument was verified by simulating each component of the instrument by Code-V.

  • PDF

The Blockchain Delivery System for Secure Privacy with QR Code and Smart Glasses (QR코드 및 스마트 글라스 활용 개인 정보 보호 블록체인 택배 시스템)

  • Choi, Seung-Joo;Sim, Min-Joo;Seo, Hwa-Jeong
    • Journal of the Korea Institute of Information and Communication Engineering
    • /
    • v.24 no.5
    • /
    • pp.630-637
    • /
    • 2020
  • The importance of protecting personal information is getting attention more than ever. However, the package delivery system has yet to keep up with the privacy movement. The waybill attached to the package contains personal information about the recipient in text form, which is exposed to anyone with visible eyesight. In order to remedy the problem, this paper proposes that the contents of the waybill should be replaced by QR code instead of plain text which can be read and accessed through the human eye. In addition, in order to prevent indiscriminate access to the contents of the QR code, the access is only permitted using smart glasses registered in the delivery blockchain network system. Lastly, to prevent leaking the contents of the QR code from the person who has access to the registered smart glasses, an inside job, the access record is recorded on the blockchain.

The Study of Wavefront Aberration Reconstruction for Optical System (광학계의 파면수차 재구성에 대한 연구)

  • Park, Seong-Jong;Ju, Seok-Hee;Kim, Sung-Gyun
    • Journal of Korean Ophthalmic Optics Society
    • /
    • v.10 no.4
    • /
    • pp.357-364
    • /
    • 2005
  • To develope the assessment equpiments of an optical system using adaptive optics, we developed the program of wavefront reconstruction for an optical system like eye. We used matlab in order to program the wavefront reconstruction for an optical system and presented the wavefront function of optical system by the zemike polynomials using modal method. To test the developed program, we calculated the zemike coefficient(n=7) of cooke triplet using code V, and compared the wavefront shape and the zemike polynomials using code V to those using the developed program. In this case, the used zemike coefficients were n=2, 3, 4, 5, 6, 7, 8, 9, and 10 and the number of sub-aperture were 1,253. From these results, we know that the reconstructed wavefronts were similar to the wavefront of cooke triplet as n was the larger than 4 and the zemike coefficient was equal to that of cooke triplet as n was 7. The developed program is able to be applied to the core technology to develope the assessment equipment of an optical system using the adaptive optics.

  • PDF

Forgery Protection System and 2D Bar-code inserted Watermark (워터마크가 삽입된 이차원 바코드와 위.변조 방지 시스템)

  • Lee, Sang-Kyung;Ko, Kwang-Enu;Sim, Kwee-Bo
    • Journal of the Korean Institute of Intelligent Systems
    • /
    • v.20 no.6
    • /
    • pp.825-830
    • /
    • 2010
  • Generally, the copy protection mark and 2D bar-code techniques are widely used for forgery protection in printed public documents. But, it is hard to discriminate truth from the copy documents by using exisiting methods, because of that existing 2D-barcode is separated from the copy protection mark and it can be only recognized by specified optical barcord scanner. Therefor, in this paper, we proposed the forgery protection tehchnique for discriminating truth from the copy document by using watermark inserted 2D-barcord, which can be accurately distinguished not only by naked eye, but also by scanner. The copy protection mark consists of deformed patterns that are caused by the lowpass filter characteristic of digital I/O device. From these, we verified the performance of the proposed techniques by applying the histogram analysis based on the original, copy, and scanned copy image of the printed documents. Also, we suggested 2D-barcord confirmation system which can be accessed through the online server by using certification key data which is detected by web-camera, cell phone camera.

Fabrication and Performance Evaluation of MR-16 Lamp Series with Narrow Angular Distribution of Luminous Intensity Using an Aspherical Planar-convex 2×2 Fly-eye Lens Type (평면-비구면 2×2 fly-eye 렌즈형태의 2차 렌즈를 사용한 고효율의 좁은 배광각을 갖는 MR-16 램프 시리즈 제작 및 성능평가)

  • Chu, Kyung-duk;Ryu, Jae Myung;Hong, Chun-Gang;Jeong, Youn Hong;Jo, Jae Heung
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.18 no.8
    • /
    • pp.25-33
    • /
    • 2017
  • This paper reports the optical design of the MR-16 lamp series with a LED second lens and an aspherical plano-convex lens suitable for a simple and rapid injection molding fabrication method. The fabrication and performance evaluation of the MR-16 lamp series, which was designed with a narrow angular distribution of luminous intensity, were conducted to replace halogen lamps with LED lamps. Four types of LED lamps were fabricated, which have angular distributions of luminous intensity of $22.4^{\circ}$, $31.1^{\circ}$, $37.3^{\circ}$, and $59.9^{\circ}$ and luminous efficiencies of 76.5 lm/W, 75.2 lm/W, 72.0 lm/W, and 77.8 lm/W, respectively, while their spreading angles with an illuminance uniformity of 81% were $3^{\circ}$, $15^{\circ}$, $22^{\circ}$, and $49^{\circ}$, respectively. After eliminating a yellow tail of the LED lamps using a diffusion sheet, the angular distributions of the luminous intensity were measured to be $20.8^{\circ}$, $31.5^{\circ}$, $37.8^{\circ}$, and $68.7^{\circ}$.

Determination of Exposure during Handling of 125I Seed Using Thermoluminescent Dosimeter and Monte Carlo Method Based on Computational Phantom

  • Hosein Poorbaygi;Seyed Mostafa Salimi;Falamarz Torkzadeh;Saeid Hamidi;Shahab Sheibani
    • Journal of Radiation Protection and Research
    • /
    • v.48 no.4
    • /
    • pp.197-203
    • /
    • 2023
  • Background: The thermoluminescent dosimeter (TLD) and Monte Carlo (MC) dosimetry are carried out to determine the occupational dose for personnel in the handling of 125I seed sources. Materials and Methods: TLDs were placed in different layers of the Alderson-Rando phantom in the thyroid, lung and also eyes and skin surface. An 125I seed source was prepared and its activity was measured using a dose calibrator and was placed at two distances of 20 and 50 cm from the Alderson-Rando phantom. In addition, the Monte Carlo N-Particle Extended (MCNPX 2.6.0) code and a computational phantom with a lattice-based geometry were used for organ dose calculations. Results and Discussion: The comparison of TLD and MC results in the thyroid and lung is consistent. Although the relative difference of MC dosimetry to TLD for the eyes was between 4% and 13% and for the skin between 19% and 23%, because of the existence of a higher uncertainty regarding TLD positioning in the eye and skin, these inaccuracies can also be acceptable. The isodose distribution was calculated in the cross-section of the head phantom when the 125I seed was at two distances of 20 and 50 cm and it showed that the greatest dose reduction was observed for the eyes, skin, thyroid, and lungs, respectively. The results of MC dosimetry indicated that for near the head positions (distance of 20 cm) the absorbed dose rates for the eye lens, eye and skin were 78.1±2.3, 59.0±1.8, and 10.7±0.7 µGy/mCi/hr, respectively. Furthermore, we found that a 30 cm displacement for the 125I seed reduced the eye and skin doses by at least 3- and 2-fold, respectively. Conclusion: Using a computational phantom to monitor the dose to the sensitive organs (eye and skin) for personnel involved in the handling of 125I seed sources can be an accurate and inexpensive method.

Iris Recognition Using a Modified CPN (CPN을 이용한 홍채 인식)

  • Hong, Jin-Il;Yang, Woo-Suk
    • Journal of IKEEE
    • /
    • v.6 no.1 s.10
    • /
    • pp.10-20
    • /
    • 2002
  • The purpose of this work is to develop a system fer rapid and automatic identification of persons, with high reliability and confidence levels. The iris of the eye is used as an optical fingerprint, having a highly detailed pattern that is unique for each individual and stable over many years. Image analysis algorithms find the iris in a image, and encode its texture into an iris code. Iris texture is extracted from the image at multiple scales of analysis by wavelet transformation. The features of many different parts of the iris are projected onto the space-frequency space. They are used to determine an abstract iris code which is similar to 2D barcode. Pattern recognition is achieved by using modified CPN.

  • PDF

Modeling and Optical Characteristics of LED-Lighting Adopting Aspherical Lens

  • Lee, Hak-Suk;Park, Jong-Rak;Kim, Min-Jae;Kim, Hye-Jung;Kim, Jung-Ho
    • Proceedings of the Korean Institute of Electrical and Electronic Material Engineers Conference
    • /
    • 2009.11a
    • /
    • pp.19-19
    • /
    • 2009
  • Recently, Light Emitting Diode(LED) has many advantages in comparison with conventional light sources; low power consumption, long lifetime, and less environmental pollution. Therefore, the use of LED is multiplying and increasing rapidly. In general, however, spherical lens is used in LED-lighting which cause many problems induces by optical aberration of spherical lens; low illumination, a yellow belt, unpleasant feeling in human eye. As a potential solution of this problem, aspherical lens can be employed. This study reports the improvement of LED-lighting performance by adopting aspherical lens. From the commercial program, $LightTools^{TM}$, the optical problem were ensured. And then, to improve this problem, optimum aspheric form was designed using Code $V^{TM}$.

  • PDF

A Study on Optical Efficiency Improvement of LED-lighting Adopting Aspherical Optical System(I) (비구면 광학계를 적용한 LED 조명의 광학성능 향상에 관한 연구(I))

  • Lee, Hak-Suk;Park, Jong-Rak;Kim, Min-Jae;Kim, Hye-Jeong;Kim, Jeong-Ho
    • Journal of the Korean Institute of Electrical and Electronic Material Engineers
    • /
    • v.22 no.12
    • /
    • pp.1033-1038
    • /
    • 2009
  • Recently, Light Emitting Diode (LED) has many advantages in comparison with conventional light sources; low power consumption, long lifetime, and less environmental pollution. Therefore, the use of LED is increasing rapidly. In general, however, spherical lens is used in LED-lighting which cause many problems induces by optical aberration of spherical lens; low illumination, yellow belt, unpleasant feeling in human eye. As a solution of these problem, aspherical lens can be employed. This study reported the improvement of LED-lighting performance by adopting aspherical lens. From the commercial program, $LightTools^{TM}$, the optical problem were ensured. And then, to improve these problem, optimum aspheric form was designed using Code $V^{TM}$.

An Encoder-Decoder for Optical CDMA System by Using an array of Superstructured Fiber Bragg Gratings (Superstructure 광섬유 브래그격자(SSFBG)를 이용한 광코드분할다중화 부호기 및 복호기)

  • Kim, Sung-Chul;Shin, Seo-Yong
    • The Journal of Korea Institute of Information, Electronics, and Communication Technology
    • /
    • v.1 no.1
    • /
    • pp.75-78
    • /
    • 2008
  • In this paper, we proposed a novel encoder/decoder for an optical CDMA(code division multiple access) system by using an array of SSFBGs(superstructured fiber Bragg gratings). The feasibility of the system is shown by the simulations. The Q-factor for the system was 14.53 dB when the well-known Gold codes are used.

  • PDF