• 제목/요약/키워드: Cod Industry

검색결과 180건 처리시간 0.028초

Performance of an Active Stimulating Device Using a Rope Kite or Array in the Cod End to Reduce Juvenile by-catch

  • Kim, Yong-Hae
    • Fisheries and Aquatic Sciences
    • /
    • 제13권2호
    • /
    • pp.182-189
    • /
    • 2010
  • An active stimulating device (ASD) using a rope apparatus may operated by the flow of turbulence inside a cod end, generating variable stimuli in addition to flow-related effects to minimize the by-catch of juvenile fishes. Preliminary testing involved a hydrodynamic effect inside the cod end with a rotating rope kite or conical rope array to generate variable stimuli (visual stimuli, water flow, or physical contact with fish) to change fish position. The experimental rope kite offered more choice in rotating period and range of sweeping action; adjusting the towing line or flow velocity helped to drive fish toward the net panel and encouraged escape. The conical shape of the rope array in the cod end helped to clear a path for fish by disturbing the rigging and providing more contrast between objects, preventing an optomotor response. This enabled more black porgy to be herded toward the net at an early stage of towing. Therefore, either a conical rope array or a rotating rope kite can be used as an effective ASD to prevent juvenile by-catch.

Fluttering Characteristics of the Ropes and Nets as an Active Stimulating Device inside the Cod End of a Trawl Net

  • Kim, Yong-Hae
    • Fisheries and Aquatic Sciences
    • /
    • 제16권2호
    • /
    • pp.101-108
    • /
    • 2013
  • An active stimulating device (ASD) consisting of a net panel or ropes fluttering in the turbulence inside the cod end was effective in driving fish near the cod end to reduce juvenile by-catch. The fluttering characteristics of the rope and net panel were examined by video observations and analyzed for fluttering amplitude and period in a water channel and in field experiments with a bottom trawl. The amplitude ratio of the fluttering ropes or nets in the tank test increased with the fluttering index as the diameter of the twine, mesh size, flexibility, and flow velocity changed, whereas the period decreased with the above factors. In bottom trawl experiments, the range of mean depth difference in the fluttering net panel was 12-17% of the length of the fluttering net, and the period of depth difference or three-dimensional (3D) tilt was revealed, with shorter ones ranging from 2 to 6 s. The amplitude as depth difference and period from field measurements were similar to those of nets in tank experiments and also to the period of 3D flow velocity inside the cod end. These results could be used to design an ASD that could be used for to the cod end of actual towed fishing gear to reduce juvenile by-catch.

Application of Electrocoagulation for Printing Wastewater Treatment: From Laboratory to Pilot Scale

  • Thuy, Nguyen Thi;Hoan, Nguyen Xuan;Thanh, Dang Van;Khoa, Pham Minh;Tai, Nguyen Thanh;Hoang, Quang Huy;Huy, Nguyen Nhat
    • Journal of Electrochemical Science and Technology
    • /
    • 제12권1호
    • /
    • pp.21-32
    • /
    • 2021
  • This study reports for the first time the application of electrocoagulation (EC) from laboratory to pilot scales for the treatment of printing wastewater, a hazardous waste whose treatment and disposal are strictly regulated. The wastewater was taken from three real printing companies with strongly varying characteristics. The treatment process was performed in the laboratory for operational optimization and then applied in the pilot scale. The weight loss of the electrode and the generation of sludge at both scales were compared. The results show that the raw wastewater should be diluted before EC treatment if its COD is higher than about 10,000 mg/L. Pilot scale removal efficiencies of COD and color were slightly lower compared to those obtained from the laboratory scale. At pilot scale, the effluent CODs removal efficiency was 81.9 - 88.9% (final concentration of 448 - 992 mg/L) and color removal efficiency was 95.8 - 98.6% (final level of 89 - 202 Pt-Co) which proved the feasibility of EC treatment as an effective pre-treatment method for printing wastewater as well as other high colored and hard-biodegradable wastewaters.

Studies on Environmental Impact of Pulp and Addtives in Liner Papermaking

  • Seo, Jin-Ho;Kim, Hyoung-Jin
    • 한국펄프종이공학회:학술대회논문집
    • /
    • 한국펄프종이공학회 2006년도 PAN PACIFIC CONFERENCE vol.2
    • /
    • pp.441-444
    • /
    • 2006
  • A lot of water is using in the paper mill for dilution, washing, sealing, and other process operation. As the regulation of water environment has been more tightened than ever before, water management in the paper mill becomes the most important task. Topics on reducing fresh water and increasing recycling water have been studied. Further, an interest in zero-effluent system has been increased. The pH of waste water in paper mill is usually weak acidic or neutral. The waste water in the paper mill includes water insoluble organic materials that are not easy to be dissolved in the water, inorganic materials that never react with water and chemical additives that are used to recycled fiber. This study investigated on the effect of various materials used in paper mill on COD. This data could be used to control the environmental load in paper mill. COD caused by raw materials and NBDCOD (Non Bio Degradable COD) after the activated sludge process are investigated in this study. Results obtained in this study can be used in a simulation program designed to control environmental load in the paper mill.

  • PDF

제지공정 폐수 전처리 수질예측을 위한 실험적 모델과 통계적 모델 개발 (Development of Empirical and Statistical Models for Prediction of Water Quality of Pretreated Wastewater in Pulp and Paper Industry)

  • 손진식;한지희;이상호
    • 상하수도학회지
    • /
    • 제31권4호
    • /
    • pp.289-296
    • /
    • 2017
  • Pulp and paper industry produces large volumes of wastewater and residual sludge waste, resulting in many issues in relation to wastewater treatment and sludge disposal. Contaminants in pulp and paper wastewater include effluent solids, sediments, chemical oxygen demand (COD), and biological oxygen demand (BOD), which should be treated by wastewater treatment processes such as coagulation and biological treatment. However, few works have been attempted to predict the treatment efficiency of pulp and paper wastewater. Accordingly, this study presented empirical models based on experimental data in laboratory-scale coagulation tests and compared them with statistical models such as artificial neural network (ANN). Results showed that the water quality parameters such as turbidity, suspended solids, COD, and UVA can be predicted using either linear or expoential regression models. Nevertheless, the accuracies for turbidity and UVA predictions were relatively lower than those for SS and COD. On the other hand, ANN showed higher accuracies than the emprical models for all water parameters. However, it seems that two kinds of models should be used together to provide more accurate information on the treatment efficiency of pulp and paper wastewater.

MBR technology for textile wastewater treatment: First experience in Bangladesh

  • Saha, Pradip;Hossain, Md. Zakir;Mozumder, Md. Salatul I.;Uddin, Md. Tamez;Islam, Md. Akhtarul;Hoinkis, Jan;Deowan, Shamim A.;Drioli, Enrico;Figoli, Alberto
    • Membrane and Water Treatment
    • /
    • 제5권3호
    • /
    • pp.197-205
    • /
    • 2014
  • For the first time in Bangladesh, a bench scale membrane bioreactor (MBR) unit was tested in treating a textile wastewater in the industry premises of EOS Textile Mills LTD, Dhaka for three months. The performance of the unit was compared with that of the conventional activated sludge treatment plant, which is in operation in the same premises. The COD and BOD removal efficiency of the MBR unit reached to around 90% and 80% respectively in 20 days whereas the removal efficiency of the conventional treatment plant was as low as 40-50% and 38-40% respectively. The outlet COD and the BOD level for the MBR unit remained stable in spite of the fluctuation in the feed value, while the conventional effluent treatment plant (ETP) failed to keep any stabilized level. The performance of the MBR unit was much superior to that of the functional ETP and the water treated by the MBR system can meet disposal standard.

마산만 주변 해역에서 오염인자와 해양환경변동과의 관계 (Relationship between Pollution Factors and Environmental Variation in Waters around Masan Bay)

  • 신소영;이충일;황선출;조규대
    • 해양환경안전학회지
    • /
    • 제10권2호
    • /
    • pp.69-79
    • /
    • 2004
  • 1981년부터 1998년까지 연구해역에서 COD와 DIP의 2월, 4월, 8월, 11월의 월별 분포양상은 비슷하였고, 두 항목 모두 8월에 가장 높은 값을 보인 반면 DIN의 경우는 2월, 4월, 8월, 11월로 갈수록 점차 증가하는 경향을 보였다. COD값은 1990년부터 1992년까지점차 증가하다가 1993년, 1994년으로 갈수록 감소하는 것을 볼 수 있는데, 이것은 마산만의 준설기간 중반부터 준설의 효과가 표층까지 나타난 것으로 보여진다. DIN과 DIP의 표층 농도 변화에는 준설의 효과가 뚜렷이 나타나지 않았다. COD의 공간적인 변동에서 적조가 빈발하였던 연도가 그렇지 않았던 연도에 비해 높은 COD농도의 분포가 마산만 밖으로 확장되어 있었고, 준설에 의한 COD값의 뚜렷한 변동은 나타나지 않았다. 전체적으로 DIN농도의 공간적인 분포 양상을 살펴보면 마산만의 안쪽에서부터 바깥쪽으로 오염이 점차 확장되었다. 마산만의 가장 안쪽 지점이 일정한 경향이 없이 높은 DIN농도를 유지하였으며, 내만 유역에 마산만의 오염원이 집중되어 있고, 마산만 유역에서 생활하수 및 산업폐수가 계속적으로 유입되고 있었다. DIP농도의 공간적인 분포에서도 마산만 준설이 DIP의 표층 농도 변화에는 뚜렷한 영향을 미치지 않은 것으로 나타났다. 강수량과 COD, DIN, DIP 농도 사이에는 일정한 상관성이 없었으며, 적조발생일수와 COD 농도 사이에는 0.66의 대체로 높은 상관성을 나타내었다.

  • PDF

복합응집제를 이용한 염색가공 폐수의 처리 (Treatment of Dye-Processing Wastewater with Complex Chemical Coagulants)

  • 서명포;김병소
    • 한국산업융합학회 논문집
    • /
    • 제9권2호
    • /
    • pp.111-116
    • /
    • 2006
  • This study provides the optimal conditions treating with the coagulation process and the other chemical treatment processes for dyeing wastewater, especially various dyeing complex wastewater. The results are shown as follows: 1. Optimum reaction condition of pH for ferrous sulfate was the range of 9 to 12. And when 3,000ppm(mg/l) of ferrous sulfate was dosed, the maximum $COD_{Mn}$ removal rate was approximately 40%. 2. In case of ferrous chloride and Bittern as coagulants, optimum pH range was 10 to 11. And maximum $COD_{Mn}$ removal rate was approximately 46% to 50% for dose of 2,000ppm(mg/l) to 6,000 ppm. 3. It is confirmed that the activated sludge process following coagulation precipitation method provides better treatment efficiency than the coagulation precipitation method following the activated sludge process. 4. The purpose of this study was to produce CGF (Cyanoguanidineformaldehyde resin) by organic compounds. 5. The complex coagulation agent by this study is the most economical coagulant with Alum(aluminum sulfate) and the removal efficiency is approximately 54% with 1,000ppm(mg/l) of pH range 6 to 7.

  • PDF

산업용 보일러의 배연탈황 및 탈질에 관한 연구 (A Study on Desulfurization and Denitrification of Flue Gas in Industry Boiler)

  • 이태호;정순형;정흥기
    • 환경위생공학
    • /
    • 제10권3호
    • /
    • pp.99-104
    • /
    • 1995
  • The objective of this study was to investigate the effect on denuclearization and decertification of flue gas by utilizing Mg( OH)$_{2}$ and NaOH as reagents in industrial boiler. We used packed absorber with Tellerette in all cases. And pH of circulation solution, rate of liquid per gas in absorber, COD concentration by pH variation in oxidation basin were inves- tigated. The following conclusions were obtained from experimental results: 1. Concerning running cost for reagents, Mg( OH)$_{2}$ reagent for treatment of flue gas was more economical than NaOH. 2. While Mg( OH )$_{2}$ and NaOH as absorbents were used, then the ratio of denuclearization was 96 and 97% respectively and nitrification was recorded 29 and 25% . 3. In this absorption tests the optimum condition for ratio of liquid per gas, pH and nonregenerable salt concentration of circulation solution were 3.6ℓ /Nm$^{3}$, 6.0, 0.5∼1.0% respectively, 4. Initial COD in oxidation basin was 800 ∼ 1,00099ut after adjusting to pH 7.0, COD of effluent water was less than 20ppm.

  • PDF