• 제목/요약/키워드: Cobalt-Chromium alloy

검색결과 36건 처리시간 0.023초

치과용 Co-Cr 합금의 제성질에 미치는 Boron과 Silicon의 영향 (Effect Boron and Silicon on Various Properties of Dental Cobalt-Chromium Alloys)

  • 정종현
    • 대한치과기공학회지
    • /
    • 제14권1호
    • /
    • pp.119-132
    • /
    • 1992
  • This paper aims to investigate the effect of B and Si upon the mechanical properties, microstructure and corrosion resistance of Co-Cr base alloy. Ten groups of alloy ingot ingot with various contents of B and Si were remelted by high frequency electrical induction furnace and cast into tensile specimen of ADA Specification No. 14 Tensile and hardness test were carried out by Amsler and Rockwell hardness tester(R-30N), respectively. The microstructures of specimen were observed by SEM. The results obtained are summarized as follows : 1. As B content is increased, tensile strength, yield strength and Rockwell hardness number(R-30N) are also increased significantly, while the elongation is decreased significantly. 2. As Si contect os increased, no significant chang in tensile strength is noticed, yield strength is slightly decreased, but Rockwell hardness number(R-30N) is moderately in creased, Elongation marks maxium value with 1% Si content while with more than 1% Si it is decreased. 3. As B content is increased corrosion resistance is decreased and is at best with 1.5% B content. Corrosion resistance is increased with the increase of Si content and the alloys with Si over 3.0% showed corrosion resistance. 4. As B content increased, precipitates are increased in number at grain boundaries. The grain size tends to become coarse with the increase of Si content. 5. Co rich-Cr alloy is present through matrix whereas at the grain boundaries Cr base precipitates are primarily formed.

  • PDF

염산(鹽酸)에 의한 CMSX-4 초내열합금(超耐熱合金)의 침출(浸出) (Leaching of CMSX-4 Superalloy in Hydrochloric Acid Solutions)

  • 김민석;이재천;김은영;유영수
    • 자원리싸이클링
    • /
    • 제19권5호
    • /
    • pp.25-30
    • /
    • 2010
  • CMSX-4 초내열합금의 순환활용을 위한 습식제련기술 개발의 일환으로 영신에서의 니켈, 코벨트, 크롬, 알루미늄 등 주요 구성 금속성분들의 침출 특성을 조사하였다. 염산농도에 따른 합금시료 내 주요 금속성분들의 침출율은 염산농도가 높아짐에 따라 증가하였으나, 3 M 이상에서는 둔화되었다 염산농도 4 M, 고액비 10 g/L, 침출시간 60 분 조건에서 침출온도가 높아짐에 따라 침출율은 급격히 증가하였으며, $90^{\circ}C$에서 니켈 93.2%, 알루미늄 89.9%, 코발트 80.4%, 크롬 79.1%의 침출율을 나타내었다. 한편 침출 초기에는 니켈과 알루미늄의 침출속도가 빠르고 60 분 이후 급격히 둔화되는 형태를 보인 반면 코발트와 크롬은 침출이 느리고 60 분 이후의 감소율만 상대적으로 적었다. 120 분 경과 시 주요 금속원소들의 침출율은 모두 99% 수준에 도달하였다. 고액비가 높아지면 침출율은 서서히 감소하였으며, 니켈과 알루미늄이 코발트와 크롬에 비하여 침출율 감소가 적었다. 염산농도 4 M, 침출온도 $90^{\circ}C$, 침출시간 120 분의 조건에서 고액비 125 g/L 이하의 조건이 주요 금속 성분의 침출에 효과적임을 확인하였으며, 이는 CMSX-4 합금의 금속학적 조직구조와 관련이 있는 것으로 생각된다.

Inconel 617 GTA 용접조건에 따른 미세조직 특성 및 기계적성질 (The Microstructures and Mechanical Properties on the GTA Welding conditions of Inconel 617)

  • 최성부;이봉근;강정윤
    • 대한용접접합학회:학술대회논문집
    • /
    • 대한용접접합학회 2005년도 추계학술발표대회 개요집
    • /
    • pp.171-173
    • /
    • 2005
  • Inconel 617 is a solid solution, nickel-chromium-cobalt-molybdenum alloy with an exceptional combination of high temperature strength and oxidation resistance. The combination of high strenth and oxidation resistance at temperatures over $1800^{\circ}F$ makes Inconel 617 an attractive material for such components as ducting, transition liners in both aircraft and gas turbine. In this study, the weldability and weldment characteristics of Inconel 617 are considered in GTAW associated with the two welding current and with back shielding gas using or not. After GTAW with 120A and 150A current, microstructures and hardness test, bending test, tensile test on room and elevated temperature for the determination of optical welding condition.

  • PDF

Comparative clinical study of the marginal discrepancy of fixed dental prosthesis fabricated by the milling-sintering method using a presintered alloy

  • Kim, Mijoo;Kim, Jaewon;Mai, Hang-Nga;Kwon, Tae-Yub;Choi, Yong-Do;Lee, Cheong-Hee;Lee, Du-Hyeong
    • The Journal of Advanced Prosthodontics
    • /
    • 제11권5호
    • /
    • pp.280-285
    • /
    • 2019
  • PURPOSE. The present study was designed to examine the clinical fit of fixed dental prosthesis fabricated by the milling-sintering method using a presintered cobalt-chromium alloy. MATERIALS AND METHODS. Two single metal-ceramic crowns were fabricated via milling-sintering method and casting method in each of the twelve consecutive patients who required an implant-supported fixed prosthesis. In the milling-sintering method, the prosthetic coping was designed in computer software, and the design was converted to a non-precious alloy coping using milling and post-sintering process. In the casting method, the conventional manual fabrication process was applied. The absolute marginal discrepancy of the prostheses was evaluated intraorally using the triple-scan technique. Statistical analysis was conducted using Mann-Whitney U test (${\alpha}=.05$). RESULTS. Eight patients (66.7%) showed a lower marginal discrepancy of the prostheses made using the milling-sintering method than that of the prosthesis made by the casting method. Statistically, the misfit of the prosthesis fabricated using the milling-sintering method was not significantly different from that fabricated using the casting method (P=.782). There was no tendency between the amount of marginal discrepancy and the measurement point. CONCLUSION. The overall marginal fit of prosthesis fabricated by milling-sintering using a presintered alloy was comparable to that of the prosthesis fabricated by the conventional casting method in clinical use.

레진 시멘트와 코발트 크롬 합금의 미세인장결합강도에 다양한 프라이머들이 미치는 영향 (Effects of primers on the microtensile bond strength of resin cements to cobalt-chromium alloy)

  • 정홍택;;박진홍;신주희;이정열
    • 대한치과보철학회지
    • /
    • 제57권2호
    • /
    • pp.95-101
    • /
    • 2019
  • 목적: 레진 시멘트와 코발트 크롬 합금 간의 미세인장결합강도에 다양한 프라이머들이 미치는 영향을 평가하기 위한 것이다. 재료 및 방법: 본 실험에서는 4개의 프라이머(Universal primer, Metal primer II, Alloy primer, and Metal/Zirconia primer)와 2개의 레진 시멘트(Panavia F2.0, G-CEM LinkAce)를 사용하였고, 길이 6 mm, 폭 1 mm, 두께 1 mm의 150개의 코발트 크롬 빔들이 캐스팅 과정을 통해 제작되었다. 150개의 코발트 크롬 빔들을 프라이머와 레진 시멘트의 종류에 따라 프라이머 처리를 하지 않은 대조군을 포함하여 10개 그룹으로 나누었다. 금속과 레진시멘트를 산화알루미늄($125{\mu}m$ 크기)으로 샌드블라스팅 처리한 후 실리콘 틀을 이용하여 접착시켰다. 실험 전에, 입체현미경(stereomicroscope)을 이용하여 모든 금속-레진 빔들을 검사하였고, 미세인장결합강도 실험을 시행하였다. 통계적인 평가에는 one-way ANOVA와 Tukey's test를 사용하였다. 결과: 모든 그룹들의 평균 미세인장결합강도는 20 - 28 MPa이었으며, 그룹 간에 통계적으로 유의한 차이는 없었다. Panavia F2.0과 G-CEM LinkAce 그룹 모두에서 접착 파절과 응집 파절이 동시에 나타나는 혼합 파절이 가장 흔하게 일어난 파절 양태였다. 결론: 모든 실험군들의 미세인장결합강도는 상대적으로 높았지만, 본 실험에서는 프라이머의 사용이 Panavia F2.0 및 G-CEM LinkAce 레진시멘트와 코발트 크롬 합금 사이의 미세인장결합강도를 증가시키지 않았다.

교정선의 종류, 결찰방법, 타액의 유무에 따른 마찰력의 비교연구 (A comparative study of frictional forces according to orthodontic wires and ligation method under dry and wet conditions)

  • 이진우;차경석;한정숙
    • 대한치과교정학회지
    • /
    • 제31권2호통권85호
    • /
    • pp.271-281
    • /
    • 2001
  • 치아에 부착된 bracket이 교정선을 따라 이동할때 필연적으로 bracket과 교정선, 결찰재 사이에 마찰력이 발생된다. 이에 저자는 동일한 bracket내에서 교정선의 종류, 결찰방법, 건조와 타액상태에 따른 마찰력 차이, 타액의 윤활제로서의 기능을 살펴보기 위해 본 연구를 시행하게 되었다. 본 실험에 사용된 bracket은 .18" ${\times}$ .025" slot의 상악 견치용 standard edgewise bracket(RMO. USA)이며, 교정선은 .016" , .016" ${\times}$ .022" 크기의 Cobalt-chromium(Elgiloy : RMO. USA), Nickel-titanium(Ni-Ti) (ORTHOLLOY : Goldstar Cable Co. KOREA), Beta- titanium(TMA : ORMCO Co., USA)의 2가지 형태의 3종을 이용하여 활주할 때의 마찰력을 만능시험기(Instron, M 1000 EC)를 사용하여 계측하여 다음과 같은 결론을 얻었다. 1. 각각의 동일조건하에서 교정선의 재질에 따른 마찰력은 Co-Cr, Ni-Ti, ${\beta}$-Ti순으로 증가하였다. 단, 타액상태에서 elastomeric으로 결찰한 .016" 군에서는 예외이다. 2. 각 조건하(건조/타액상태, .016" /.016" ${\times}$.022" ) 에서 결찰방법에 따른 마찰력은 elastomeric보다 stainless steel결찰에서 더 크게 나타났다(p<0.05). 3. 각각의 교정선과 결찰방법에서 타액 유무에 따른 마찰력은 stainless steel로 결찰한 .016" Co-Cr, Ni-Ti, ${\beta}$-Ti는 타액상태에서 감소하나, stainless steel로 결찰한 .016" ${\times}$.022" Co-Cr, Ni-Ti, ${\beta}$-Ti는 타액상태에서 증가하였다(p<0.05). 4. 각 조건하(건조/타액상태, elastomeric/stainless steel 결찰) .016" 과 .016" ${\times}$.022" 교정선 사이의 마찰력은 .016" ${\times}$.022" 교정선에서 증가하였다(p<0.05).

  • PDF

레이저 융합된 Co-Cr 합금의 물리적 성질에 관한 연구 (MECHANICAL PROPERTIES OF LASER WELDED Co-Cr ALLOY)

  • 배기창;우이형;이성복
    • 대한치과보철학회지
    • /
    • 제41권4호
    • /
    • pp.440-450
    • /
    • 2003
  • Statement of problem : The joints of removable partial denture alloys have failed frequently after routine usage. Purpose : The purpose of this study was to evaluate the mechanical properties of the laser welded Co-Cr alloys. Material and method : For this study 20 Co-Cr specimens were casted and 10 of them were seperated on the middle area and laser welded with Alpha laser welding machine(Siro Lasertec, Pforzheim, Germany). Rest of them which were as cast, were used as a control group. For the section of the experimental specimens, wire cutting machine was used to make a even gap of the all specimens. Laser welding was done with manufacturer's instrunction and tested each specimen by Instron Machine. Tensile strength, 0.2% yield strength and % elongations were recorded. Fractured surfaces were investigated with SEM. Results : The results were as follows : 1. The tensile strength of the laser welded group(617.7MPa) was about 75% of the as cast group(820.4MPa). It had stastically significant differences(p<0.05). 2. The % elongation of the experimental group was 6.6 which was lower than the control group(14.3). 3. Fracture of the experimental group occured in the welded surface and showed many voids. In contrast, the fracture surface of the control group was showed rough surfaces without any voids. Conclusion : The tensile strengths of the as-cast joints were higher than those for the laser welded joints, and the % elongation of the experimental group was lower than the control group. Porosity was found in laser-welded joints.

In vitro evaluation of the bond strength between various ceramics and cobalt-chromium alloy fabricated by selective laser sintering

  • Bae, Eun-Jeong;Kim, Hae-Young;Kim, Woong-Chul;Kim, Ji-Hwan
    • The Journal of Advanced Prosthodontics
    • /
    • 제7권4호
    • /
    • pp.312-316
    • /
    • 2015
  • PURPOSE. This study aimed to present the clinical applicability of restorations fabricated by a new method, by comparing the bond strength of between ceramic powder with different coefficient of thermal expansion and alloys fabricated by Selective laser sintering (SLS). MATERIALS AND METHODS. Fifty Co-Cr alloy specimens ($25.0{\times}3.0{\times}0.5mm$) were prepared by SLS and fired with the ceramic ($8.0{\times}3.0{\times}0.5mm$) (ISO 9693:1999). For comparison, ceramics with different coefficient of thermal expansion were used. The bond strength was measured by three-point bending testing and surfaces were observed with FE-SEM. Results were analyzed with a one-way ANOVA (${\alpha}$=.05). RESULTS. The mean values of Duceram Kiss ($61.18{\pm}6.86MPa$), Vita VM13 ($60.30{\pm}7.14MPa$), Ceramco 3 ($58.87{\pm}5.33MPa$), Noritake EX-3 ($55.86{\pm}7.53MPa$), and Vintage MP ($55.15{\pm}7.53MPa$) were found. No significant difference was observed between the bond strengths of the various metal-ceramics. The surfaces of the specimens possessed minute gaps between the additive manufactured layers. CONCLUSION. All the five powders have bond strengths higher than the required 25 MPa minimum (ISO 9693); therefore, various powders can be applied to metal structures fabricated by SLS.

심미보철용 코어재료와 베니어 세라믹 계면의 전단결합강도 비교 (Shear Bond Strength between Veneered Ceramics and Core Materials for Esthetic Restorations)

  • 김기원;박항민;정인성
    • 대한치과기공학회지
    • /
    • 제31권2호
    • /
    • pp.45-52
    • /
    • 2009
  • Esthetic restorations have been widely used in dental practice, although many studies have focused on the development and improvement of all ceramic restorations. The success of esthetic restorations depends primarily on an optimal bond strength between various veneered ceramics and core materials for esthetic restorations. The purpose of this study was to compare the shear bond strength between various veneered ceramics and core materials for esthetic restorations. 30 metal cores and 20 zirconia cores were fabricated and divided into five groups according to veneered ceramic materials such as Creation porcelain powder, Cercon Ceram Kiss, and IPS e.max ZirPress. Thirty spacimens were prepared using Creation porcelain powder, veneered 3mm height and 3mm in diameter, over the metal cores (n=10). Twenty specimens were prepared using Cercon Ceram Kiss and Zirpress, veneered 3mm height and 3mm in diameter, over the zirconia cores (n=10). The shear bond strength test was performed in a universal testing machine with a crosshead speed of 1mm/min. Ultimate shear bond strength data were analyzed with One-way ANOVA and the Scheffe's test (p=.05). Within the limits of this study, the following conclusions were drawn: The mean shear bond strengths (MPa) were: 18.44 for Uni metal VH/Creation (NCUC); 18.72 for Heraenium/Creation (NCHC); 16.23 for Wirobond C/Creation (NCWC); 13.88 for Zirconia core/$110{\mu}m$ $Al_2O_3$ sandblasting/Cercon Ceram Kiss (ZS110P); 14.61 for Zirconia core/No surface treatment/IPS e.max ZirPress (ZNTH). The mean shear bond strength for NCUC (Uni metal VH/Creation), NCHC (Heraenium/Creation) and NCWC (Wirobond C/Creation) were significantly superior to ZS110P (Zirconia core/$110{\mu}m$ $Al_2O_3$ sandblasting/Cercon Ceram Kiss) and ZNTH(Zirconia core/No surface treatment/IPS e.max ZirPress) (p<0.05).

  • PDF

Evaluation of marginal and internal gaps of Ni-Cr and Co-Cr alloy copings manufactured by microstereolithography

  • Kim, Dong-Yeon;Kim, Chong-Myeong;Kim, Ji-Hwan;Kim, Hae-Young;Kim, Woong-Chul
    • The Journal of Advanced Prosthodontics
    • /
    • 제9권3호
    • /
    • pp.176-181
    • /
    • 2017
  • PURPOSE. The purpose of this study was to evaluate the marginal and internal gaps of Ni-Cr and Co-Cr copings, fabricated using the dental ${\mu}-SLA$ system. MATERIALS AND METHODS. Ten study dies were made using a two-step silicone impression with a dental stone (type IV) from the master die of a tooth. Ni-Cr (NC group) and Co-Cr (CC group) alloy copings were designed using a dental scanner, CAD software, resin coping, and casting process. In addition, 10 Ni-Cr alloy copings were manufactured using the lost-wax technique (LW group). The marginal and internal gaps in the 3 groups were measured using a digital microscope ($160{\times}$) with the silicone replica technique, and the obtained data were analyzed using the non-parametric Kruskal-Wallis H test. Post-hoc comparisons were performed using Bonferroni-corrected Mann-Whitney U tests (${\alpha}=.05$). RESULTS. The mean (${\pm}$ standard deviation) values of the marginal, chamfer, axial wall, and occlusal gaps in the 3 groups were as follows: $81.5{\pm}73.8$, $98.1{\pm}76.1$, $87.1{\pm}44.8$, and $146.8{\pm}78.7{\mu}m$ in the LW group; $76.8{\pm}48.0$, $141.7{\pm}57.1$, $80.7{\pm}47.5$, and $194.69{\pm}63.8{\mu}m$ in the NC group; and $124.2{\pm}52.0$, $199.5{\pm}71.0$, $67.1{\pm}37.6$, and $244.5{\pm}58.9{\mu}m$ in the CC group. CONCLUSION. The marginal gap in the LW and NC groups were clinically acceptable. Further improvement is needed for CC group to be used clinical practice.