A Study on The Ultra-precision Polishing Method of Co-Cr-Mo alloy Using MR Fluid Polishing (MR Fluid Polishing을 이용한 Co-Cr-Mo alloy의 초정밀 연마 방법)

  • Shin, Bong-Cheol;Kim, Byung-Chan;Song, Ki-Hyeok;Cho, Myeong-Woo
    • Design & Manufacturing
    • /
    • v.11 no.3
    • /
    • pp.8-12
    • /
    • 2017
  • In general, metallic bio-materials is more widely used in solid tissue like bone or tooth than flexible tissue such as skin or muscle. Especially, Cobalt Chrome Molybdenum(Co-Cr-Mo), which is used in tooth surgery, has a great corrosion resistance. Because this bio-material is non-toxic in human body, and has a bio-compatibility that the vital reaction is not occurred with tissue in body. However the chemical reaction is occurred by fatal matter that deteriorate the property of material surface in conventional polishing, and it can affect to fatal disease in human body or decrease the material properties such as hardness, yield strength or bio-compatibility. This surface in poor condition can cause development of corrosion or bacteria. In this study, MR fluid polishing is used to minimize the scratch, pit or surface flaws generated in conventional polishing. Surface roughness is measured according to the polishing condition to obtain fine surface condition.

Evaluation of a metal level in non-precious metal alloys dental casting having beryllium by lactic acid Solution (베릴륨함유 치과 주조용 비귀금속 합금의 젖산용액에 의한 금속 노출수준 평가)

  • Park, Soo-Chul;Jang, Eun-Jin;Han, Sok-Yoon
    • Journal of Technologic Dentistry
    • /
    • v.33 no.2
    • /
    • pp.121-128
    • /
    • 2011
  • Purpose: The purpose of this study is to investigate the level of each metal in non-precious metal alloys dental casting, still used even banned for use and trade by the law, for oral health. Methods: Two kinds of metal alloys were analyzed. One was Ticonium 100 for removable prosthesis and the other was Rexillium V for dental porcelain. Two samples of each metal alloy were made in 0.5g, 1.0g, and 1.5g. Total number of samples were 12. Two kinds of lactic acid Solution, pH7 and pH4.6, were injected into each samples. After injection, each samples had been for 21days ${\pm}$ 1 hour in the water tank of which temperature was $37^{\circ}C$. The level of metal was measured in each sample by inductively couplled plasma-atomic emission spectrometer. Results: In both metal alloys, metals, chrome, nickel, beryllium, and molybdenum, were founded. In Ticonium 1000, the highest level of nickel was 2.531ppm in 1.5g pH4.6 sample while the highest level of nickel was 4.062ppm in 1.5g pH4.6 sample of Rexillium V. In chemical composition of these methal alloys, chrome(14~17%) was much more than beryllium(1.95~1.99%) and molybdenum(5.0~9.0%) but berllium and molybdenum were founded more than chrome in samples. Therefore, chrome showed better anti-corrosion than other metal alloys. In both metal alloys, more metals were founded in higher pH level and more mass. Levels of chrome was significantly different in samples of both metal alloys in each pH level(p<0.05). Levels of nickels was significantly different in samples of both metal alloys in each pH level(p<0.05). Conclusion: For oral health, further studies are needed in nickel-chrome metal alloy and cobalt metal alloy of non-beryllium in addittion to beryllium metal alloy and also long-term studies needed in various period and other non-percious metal alloys for dental casting.

The Effect of Titanium on the Castability of Cobalt-Chrome Alloy (코발트 크롬 합금의 주조성에 미치는 타이타늄의 효과)

  • Ryu, Su-Kyoung;Chung, Hee-Jeong;Vang, Mong-Sook;Yang, Hong-So;Lim, Hyun-Pil;Yun, Kwi-Dug;Park, Sang-Won
    • Journal of Dental Rehabilitation and Applied Science
    • /
    • v.27 no.1
    • /
    • pp.73-79
    • /
    • 2011
  • Purpose of this experiment is to evaluate the effect of titanium on the castability when the titanium is added to the Co-Cr alloy. Raw materials Cobalt, Chrome, Molybdenum, Silicon, Manganase, Carbon, Nitrogen, Titanium were weighted and prepared. $Biosil^F$ (Degudent, Germany) was the control group. To the experimental group, different weight percent of titanium was added from 1 wt% to 4 wt%. The wax pattern is $30{\times}40$ cm in size, rectangular in shape and has total of 160 grids. Centrifugal machine (Neutrodyne Easy Ti: Manfredy) was used for casting. For evaluation of the castability, the number of complete grids was counted by visual inspection and X-ray inspection. The test showed similar castability with the control group in the titanium addition of 1 wt% to 3 wt%. The titanium addition of 4 wt% showed poor result. With titanium lower than 4 wt%, the experiment metals showed proper castability with high expectation of successful clinical use.

The Biocompatibility Of Cultured Bone Marrow Cells And Gingival Fibroblasts On The Titanium Surfaces (티타늄 배양에 대한 배양골수와 치은 섬유아세포의 생체적합성)

  • Oh, Choong-Young;Park, Joon-Bong;Kwon, Young-Hyuk;Lee, Man-Sup
    • Journal of Periodontal and Implant Science
    • /
    • v.26 no.1
    • /
    • pp.143-160
    • /
    • 1996
  • The purpose of this study was to evaluate the response in aspect of attachment and growth rate of osteoblasts and growth rate of osteoblasts and human gingival fibroblasts to the commercially pure titanium(CP titanium)and titanium alloy(Ti-6AI-4V) that are used widely as implant materials, and to obtain the basic information to ideal implant materials. In the studly, commercially pure titanium in first test group, titanium alloy(Ti-6AI-4V) in second test group, cobalt-chrome-molybdenum alloy(Co-Cr-Mo alloy) in positive control group, and tissue culture polystyrene plate in negative control group were used. The results of this study were as follows. 1. Bone marrow cells cultured on CP titanium and Ti-6Al-4V showed significantly greater attachment and growth rate(p(0.05) compared to Co-Cr-Mo alloy in each time. 2. There were no significant differences(p>0.05) in attachment and growth rate of bone marrow cells cultured on CP titanium and Ti-6AI-4V or tissue culture plate. 3. Most bone marrow cells cultured on CP titanium, Ti-6Al-4V and tissue culture plate were attached well to each substratum in first 2days, and then, grew at higher growth rate. On the other hand, some cells cultured on Co-Cr-Mo alloy failed to attach in first 2 days, and then, attached cells grew at lower growth rate than other groups. 4. Attachment and growth rates of gingival fibroblasts cultured on CP titanium and Ti-6Al-4V showed no significant differences(p>0.05) compared to Co-Cr-Mo alloy in 2 days, but significantly greater increase(p<0.05) in 5 and 9 days. 5. There were no significantly differences(p>0.05) between growth rates on gingival fibroblasts cultured on CP titanium, Ti-6Al-4V and tissue culture plate in 2 and 5days, but a significant lower growth rate(p<0.05) on CP titanium and Ti-6Al-4V versus tissue culture plate. 6. Some gingival fibroblasts cultured on all specimen groups failed to attach, but attached cells grew well, especially on CP titanium, Ti-GAl-4V and tissue culture plate. 7. There were no significant differences(P>0.05) between growth rates of both bone marrow cells and gingival fibroblasts cultured on CP titanium and Ti-6AI-4V. As a result of this study, both commercially pure titanium and Ti-6AI-4V showed excellent biocompatibility and there was no significant difference in the cellular response to the both metals. Bone marrow cells cultured on each substratum showed significantly greater growth rate and responded sensitively to cytotoxic effects of metal surfaces compared to gingival fibroblasts. Considering cell response to the substrate, it was likely that the composition itself of titanium metals have no significant effect on the biocompatibility. Further study need to be done to evaluate the influence of surface characteristics on cellular responses.

  • PDF

A Study on Heavy Metal Concentrations in Waste Water Produced in the Casting Pickling Process at Dental Technical Laboratories (치과기공소 주조체 산세척과정에서 발생하는 폐수내 중금속 농도)

  • Jeong, Da-i;Sakong, Joon
    • Journal of Environmental Health Sciences
    • /
    • v.44 no.1
    • /
    • pp.55-62
    • /
    • 2018
  • Objectives: This study set out to measure the heavy metal concentrations in waste water produced in the casting pickling process at dental technical laboratories and examine the actual state of its treatment. Methods:The investigator measured the concentrations of each heavy metal at 55 dental technical laboratories using an inductively coupled plasma optical emission system. Results: The annual usage of electrolytes was under 10 L in 50 (90.9%), and was 10L or more in five (9.1%) laboratories. Among the laboratories, 15 (27.3%) commissioned the treatment of waste,12 (21.8%) treated the waste with general sewage,and 28 (50.9%) treated the waste in aseptic tank. The arithmetic $mean{\pm}standard$ deviation and the geometric mean of chrome(Cr) were $75.3{\pm}50.9$ and 58.3 mg/L; those of cobalt (Co) were $112.3{\pm}106.7$ and 66.1 mg/L; those of nickel (Ni) were $62.9{\pm}83.5$ and 8.9 mg/L; those of molybdenum (Mo) were $17.1{\pm}13.4$ and 12.0 mg/L; those of iron (Fe) were $31.5{\pm}44.1$ and 6.2 mg/L; those of lead (Pb) were $0.3{\pm}0.3$ and 0.3 mg/L; those of beryllium (Be) were $3.6{\pm}3.6$ and 2.0 mg/L. The hydrogen ion concentration was under pH 2 across all the samples. Conclusions: The findings show that the dental technical laboratories were not doing well with the separation, storage, collection, and treatment of the electrolytes they discarded, and that most of the electrolytes were introduced through the general sewage or aseptic tank. The causes of this include alack of perception among the practitioners at dental technical laboratories and contracted companies avoiding collection for economic reasons. There is a need for education to improve the perceptions of waste water treatment among the practitioners at dental technical laboratories. Environment-related departments should be stricter with legal applications in the central and local governments. It is also required to provide proper management of commissioned treatment.

Analysis of Changes in Trade Structure of the Raw Materials of Rare Metals in Korea (국내 희유금속 원재료 교역구조 변화 분석 연구)

  • Hwa Suk Lee;Yu Jeong Kim
    • Resources Recycling
    • /
    • v.32 no.6
    • /
    • pp.67-78
    • /
    • 2023
  • The rare metals used as raw materials in high-tech industries undergo changes in demand structures and supply chains following domestic industrial structural shifts and technological advancements, exhibiting high price volatility. Therefore, it is necessary to periodically analyze changes in the demand structures of rare metals. Since domestic demand for most rare metals relies on imports in Korea, the changes in domestic demand for rare metals can be identified by analyzing changes in their trade structure. In the present study, we analyze the changes in trade volume, trade growth rate, trade rankings, and trading countries from 2000 to 2022 for 35 rare metals, categorized into five types-ores, metals, alloys, compounds, and scrap. The trade of the raw materials of rare metals in Korea has generally increased since the 2000s, except for a significant decline in 2009 and 2016. The total trade volume, encompassing both exports and imports, has increased by approximately tenfold in 2022 compared to 2001. Until the mid-2010s, the trade of the raw materials of rare metals was primarily focused on those used in steel-manufacturing such as silicon, nickel, chrome, molybdenum, manganese, and others. However, after that period, there has been an increase in the trade of platinum group metals like palladium, rhodium, platinum, and the raw materials of rare metals for secondary battery-manufacturing such as lithium and cobalt. Particularly in 2022, lithium has become the largest share in trade of the raw materials of rare metals in Korea, due to the price surge and increase in demand.