• Title/Summary/Keyword: Coaxial Line

Search Result 158, Processing Time 0.034 seconds

Residual Voltage Reduction of Coaxial Surge Arrestor Using Ceramic Filler (세라믹 필터를 이용한 동축 서지어레스터의 잔류전압 저감)

  • Eom, Ju-Hong;Cho, Sung-Chul;Lee, Tae-Hyung;Lee, Young-Chul
    • Journal of the Korean Institute of Illuminating and Electrical Installation Engineers
    • /
    • v.21 no.2
    • /
    • pp.46-53
    • /
    • 2007
  • Extension of the mobile communication and the rapidly developing services connected with wireless multimedia(W-CDMA, DMB, Wibro, and so on) need great many base station transceiver systems, antennas, and many signal transmission line to embody these services. The min communication appliances system is exposed always in danger of transient overvoltage by direct stroke or induced lightning surge flowing in through antenna because the antenna of base station transceiver system or relay equipment is combined with expensive communication network equipments through signal transmission line. Now, gas discharge tube(GDT) or narrow band stub arrestor which is used by the surge protector for communication use is exposing limitations as for lightning surge protective means of the communication facility with high speed and wide frequency band. Therefore, for improving performance of surge arrestor, we applied ceramic filter which can reduce lightning surge invading from antenna effectively, and proved that ceramic filter is effective in residual voltage reduction through the experimental research.

A Technique for Broadbanding the CPW-Fed Bow-Tie Slot Antenna

  • Kim Sung-Hak;Wen Lijun;Ko Han-Woong;park Dong-Hee;Ahn Bierng-Chearl
    • Journal of electromagnetic engineering and science
    • /
    • v.5 no.1
    • /
    • pp.14-20
    • /
    • 2005
  • In this paper, a technique is presented for broadbanding the bow-tie slot antenna fed by a CPW(coplanar waveguide). The bandwidth performance of existing bow-tie slot designs is greatly enhanced by optimizing the slot shape and properly adjusting the characteristic impedance of the coplanar waveguide feeding the slot. To connect the 50-ohm input coaxial line to the CPW feed line, a linear taper in the CPW is employed. The designed antenna shows a 3.5 $\~$ 10.0 GHz impedance bandwidth, a 3.5 $\~$ 6.0 GHz pattern bandwidth, and a 5.5 $\~$ 7.5 dBi gain over 3.5 $\~$ 6.0 GHz. Above 6.0 GHz, the antenna radiation pattern appreciably deviates from the typical dipolar pattern.

Analysis of Hydrid Fiber Coaxial technology and Market (HFC 기술 및 시장 분석)

  • Yoo, H.K.;Kim, J.H.;Kang, B.Y.;Park, K.C.
    • Electronics and Telecommunications Trends
    • /
    • v.18 no.6 s.84
    • /
    • pp.34-40
    • /
    • 2003
  • 1998년 시작된 초고속 인터넷 서비스는 약 4년 만에 세계 1위의 보급률을 보이고 있을 정도로 우리 나라의 정보통신 인프라는 급속도로 성장하여 왔다. 최근 유무선 통합 및 통신과 방송이 융합되는 광대역 통합망(BcN) 환경에서 초고속 인터넷 서비스와 디지털방송 서비스를 제공하기 위한 초고속 인프라의 가입자망 형태는 동선 기반의 ADSL(Asymmetric Digital Subscriber Line)/VDSL(Very high-data rate Digital Subscriber Line) 및 광/동축 혼합망인 HFC, 광섬유 기반의 FTTH(Fiber To The Home) 등이 있다. 그 중에서 HFC는 그 동안 주로 케이블 TV 프로그램의 전송망으로 활용되어 오다가 최근 통신. 방송 융합 환경에서 초고속 인터넷 가입자망으로 부각되고 있다. 본 고에서는 HFC 망의 특성과 HFC 망의 핵심장비인 CMTS와 케이블모뎀의 시장 현황 및 전망에 대해서 알아보고, 광대역 통합망의 가입자망으로서의 HFC의 역할에 대해 논의하고자 한다.

Effect of Etch Hole Position and Sacrificial Layer Residue on a Novel Half-Coaxial Transmission Line Filter (에치홀의 위치와 희생층의 잔류물이 전송선 필터 응답에 미치는 영향)

  • Kim, Yong-Sung;Baek, Chang-Wook;Kim, Yong-Kweon
    • Proceedings of the KIEE Conference
    • /
    • 2007.07a
    • /
    • pp.284-285
    • /
    • 2007
  • In this paper, we present the effect on a novel transmission line filter response by the etch hole position on the suspended ground and the residue on the resonator under ground plane. We defined the etch hole offset as the distance from the sidewall of the suspended ground to the nearest side of the etch holes. We simulated new filter responses to reflect the real value of the changed etch hole offset caused by characteristics of negative photoresist. Return loss is distorted by the residue on the center conductor remained after sacrificial layer removing. By comparison of simulation and measurements, we concluded the residue on the resonator distorted the RF response worse than etch hole offset variation did.

  • PDF

A Study on the Detection of the Rain Using Open-Ended Coaxial Cavity Resonator (한쪽 면이 열린 동축 공동 공진기를 이용한 빗물 감지에 관한 연구)

  • Lee, Yun-Min;Kim, Jin-Kuk;Hur, Jung
    • The Journal of Korean Institute of Electromagnetic Engineering and Science
    • /
    • v.24 no.9
    • /
    • pp.944-950
    • /
    • 2013
  • This paper is a study of a rain sensor using an open-ended coaxial cavity resonator which senses the amount of rain drops linearly. It shows that it will be used as a sensor to sense the amount of rain dropped on the windshield of an automobile based on the principle of varied resonant frequency and the loss according to the amount and characteristics of an dielectric lied on the open side of a resonator. The input and output ports are built in the both sides of the resonator and the input and output coupling probes are formed like 'ㄱ' shape. The response of rain drops were simulated by the radius of inner conductor of 2 mm, 5 mm, and 10 mm respectively and it showed that the raindrop was sensed most linearly and sensitively when the radius of inner conductor is 5 mm, We have measured that the resonant frequency have varied from 3.55 GHz to 3 GHz and the Q value have varied from 42.38 to 24.3 according to the variation of rain drop amount on the fabricated resonator. Therefore, it shows that the designed resonator can be applied as a rain sensor that measures the amount of rain drops linearly by using the resonant frequency as a measurement parameter.

Development of Monitoring and Control System of Utility-Pipe Conduit (Power Tunnel) using PLC

  • Lee, Tae-Young;Park, Byung-Seok;Ju, Seong-Ho;You, Dong-Hee;Lim, Yong-Hoon;Song, Seok-Young
    • 제어로봇시스템학회:학술대회논문집
    • /
    • 2004.08a
    • /
    • pp.116-119
    • /
    • 2004
  • The existing monitoring and control systems of utility-pipe conduit (power tunnel, cable tunnel etc) have established communication lines using optical fiber, leaky coaxial cable (LCX), and several kinds of control cable. Due to the properties of the used media, the cost of equipment is considerably high and the maintenance of the system is difficult. Also, the term of carrying out is long so that the extension of the system is in difficulty. Now it is desirable to adopt Power Line Communication (hereinafter, PLC) technology in the monitoring and control systems and use the existing low-voltage power-line for lamplight as communication line. This will lead the reduction of the construction cost and the easy maintenance of the system. In this paper, we research the characteristics of PLC in conduit, design and manufacture the field test system, and analyze the performance of the system by field test. Then, we introduce the reliable monitoring and control system of utility-pipe conduit using PLC.

  • PDF

Mecrostrip Array Antenna Directly Coupled to E-Plane (E-면으로 직접 결합된 마이크로스트립 어레이 안테나)

  • Kim, Tae-Hyung;Hong, Jae-Pyo;Pak, Chin-Taek;Cho, Young-Ki;Son, Hyon
    • Journal of the Korean Institute of Telematics and Electronics A
    • /
    • v.28A no.1
    • /
    • pp.23-29
    • /
    • 1991
  • In order to improve the radiation characteristics of the microstrip antenna, microstrip array antenna consisting of one center patch fed by a coaxial probe and several patches directly coupled to the E-plane by microstrip line is analyzed. The equivalent circuit of the array antenna is represented by the conventional transmission line and the various parameters, such as the mdicrostrip line length, the patch length and the feed point location are calculated to improve the radiation pattern for 5-patch array antenna which has the equal patch width. The 5-patch array antenna with the radiation pattern which has low sidelobe level and narrow beam width is fabricated and then the measured results are compared with the computed values and the results of the single patch microstrip antenna too.

  • PDF

Generation of Ultrawide Band Electromagnetic Pulse from Blumlein Pulse Forming Line

  • Jin, Yun Sik;Kim, Jong Soo;Cho, Chuhyun;Roh, Young Su
    • Journal of Electrical Engineering and Technology
    • /
    • v.9 no.2
    • /
    • pp.677-681
    • /
    • 2014
  • A high voltage pulse generator was fabricated to radiate ultrawide band electromagnetic pulse. A coaxial type of Blumlein pulse forming line is employed to produce a pulse of high voltage (>300 kV) and short pulse duration (~5 ns). A helical strip/wire type of air-cored pulse transformer was used to charge the Blumlein pulse forming line up to more than 300 kV. A peaking switch is essential to make the pulse rise time as fast as possible. Typically, the rise time is ~500 ps. The output pulse of the generator is radiated into air through an exponentially tapered TEM horn antenna. The electric field intensity of a radiated pulse was measured as a function of the distance from the transmitting horn as well as the output voltage of the peaking switch. The peak-to-peak value of the electric field intensity at 10 m from the TEM antenna was~100 kV/m.

Impedance Characteristics of Overhead Medium-Voltage Power lines for Power Line Communication (전력선통신을 위한 고압 배전선로의 임피던스 특성)

  • Chun Dong-wan;Park Young-jin;Kim Kwan-ho;Shin Chull-chai
    • Journal of the Institute of Electronics Engineers of Korea TC
    • /
    • v.42 no.11
    • /
    • pp.67-78
    • /
    • 2005
  • In this paper, impedance characteristics of overhead medium-voltage (MV) power line for power line communication (PLC) is analyzed. For analysis, a two-port equivalent network model of MV power lines is derived. By applying the equivalent model and basic transmission line theory, input impedance at the signal induction part is calculated. And also calculated input impedance of power line itself that the medium voltage coupler and coaxial cable effect are removed. For verification, impedance of power lines is measured at a test field for an MV PLC. The results show that impedance of MV power line itself is between $200\;{\Omega}\;and\;300\;{\Omega}$ and converges to a half of their characteristic impedance with increasing frequency. And also measured data is very similar to calculated data.

Input Impedance Calculation of the Power Line Communication System (전력선 통신 시스템의 입력 임피던스 계산)

  • Chun, Dong-wan;Lee, Jin-taek;Park, Young-Jin;Kim, Kwan-Ho;Shin, Chull-Chai
    • The Journal of Korean Institute of Communications and Information Sciences
    • /
    • v.29 no.9A
    • /
    • pp.983-990
    • /
    • 2004
  • In this paper, we calculated the input impedance of the power line communication(PLC) networks using medium voltage power line. First of all, we proposed input and output teoninal model of PLC network, and calculated the input impedance applying the attenuation constants by radiation loss, conductor loss, dielectric loss. From the calculation result, we knew that the attenuation by radiation loss was largest, and the input impedance appears like a standing wave fonn with a fixed cycle because the high reflection at the input terminal for the characteristic impedance of the power line is very large. And also the cycle of input impedance depends on the coaxial cable length, and the amplitude depends on the characteristic impedance of power line and losses. From the measurement result, calculated result was very similar to the measured result.