• 제목/요약/키워드: Coated materials

검색결과 2,591건 처리시간 0.032초

Electrochemical behavior of Calcium Titanate Coated Ti-6Al-4V Substrate in Artificial Saliva

  • Lee, Byoung-Cheon;Balakrishnan, A.;Ko, Myung-Won;Choi, Je-Woo;Park, Joong-Keun;Kim, Taik-Nam
    • 한국재료학회지
    • /
    • 제18권1호
    • /
    • pp.22-25
    • /
    • 2008
  • In this study, calcium titanate $(CaTiO_3)$ gel was prepared by mixing calcium nitrate and titanium isopropoxide in 2-methoxy-ethanol. $CaTiO_3$ gel was single-layer coated on Ti-6Al-4V using a sol-gel dip-coating technique. The coating was calcined at $750^{\circ}C$ in air by utilizing a very slow heating rate of $2^{\circ}C/min$. The crystalline phases of the coating were characterized by x-ray diffraction using a slow scan rate of $1^{\circ}/min$. The morphology of the coating was analyzed by scanning electron microscopy. The corrosion behavior of Ti-6Al-4V samples coated with $CaTiO_3$ films were tested in an artificial saliva solution by potentiodynamic polarization and were quantified by the Tafel extrapolation method. The electrochemical parameters showed a considerable increase in the corrosion resistance for the $CaTiO_3$-coated Ti-6Al-4V samples compared to bare substrates.

Fabrication and characterization of PCL/TCP-coated PHBV composite multilayer as a bone plate

  • Kim, Yang-Hee;Song, Ho-Yeon;Lee, Byong-Taek
    • 한국재료학회:학술대회논문집
    • /
    • 한국재료학회 2009년도 추계학술발표대회
    • /
    • pp.39.2-39.2
    • /
    • 2009
  • In this work, Poly($\varepsilon$-Caprolactone)(PCL) andpoly(3-hydroxybutyrate-co-3-hydroxyvalerate)(PHBV) mats were fabricated usingelectrospinning process. The electrospinning process is a simple and efficient method to fabricate the nanofibrous mats. PCL and PHBV is a kind of biodegradable polymer but their mechanical properties aren't good. For improving mechanical properties, PHBV mats were coated by TCP. Using PCL mats and TCP-coated PHBV composite mats, a bio-resorbablebone plate were made by pressing. Detailed micro-structural characterization was done by SEM techniques. Tensile strength and bending strength were also evaluated for mechanical properties. The cytotoxicity evaluation ofPCL/TCP-coated PHBV composite multilayer was done by MTT assay. The evidence obtained in this work implies the potential for use as a biodegradable boneplate.

  • PDF

안정화 층을 갖는 YBCO Coated Conductor와 BSCCO 선재의 결합이 과전류 통전 특성에 미치는 영향 (Effect of Transport Current Properties on Connecting of YBCO Coated Conductor having Stabilizer Layer and BSCCO Tape)

  • 두호익;김민주;박충렬;두승규;김용진;한병성
    • 한국전기전자재료학회논문지
    • /
    • 제21권10호
    • /
    • pp.950-953
    • /
    • 2008
  • YBCO coated conductor called the second-generation superconducting tapes have resistance increase significantly more than BSCCO tapes in terms of the speed or amount when quench occurs, they may have different ranges of application. Such characteristics are thought to get different properties by selection of stabilizing materials in manufacturing superconducting tapes. It is important in selecting superconducting tapes which will be applied to power devices in the future. In this study, one kind of BSCCO tapes and two kinds of YBCO CC with different stabilizing materials and one kind of YBCO CC with non stabilizing materials were used to compare and examine transport characteristics in flux-flow state and quench state with each tape joint of HTS tapes.

Effects of HA and TiN Coating on the Electrochemical Characteristics of Ti-6Al-4 V Alloys for Bone Plates

  • Oh, Jae-Wook;Choe, Han-Cheol;Ko, Yeong-Mu
    • 한국표면공학회지
    • /
    • 제37권5호
    • /
    • pp.249-252
    • /
    • 2004
  • Effects of HA and TiN coating on the electrochemical characteristics of Ti-6AI-4V alloys for bone plates were investigated using various test methods. Ti-6AI-4V alloys were fabricated by using a vacuum induction furnace and bone plates were made by laser cutting and polishing. HA was made of extracted tooth sintered and then tooth ash was used as HA coating target. The TiN and HA film coating on the surface were carried on using electron-beam physical vapor deposition (EB-PVD) method. The corrosion behaviors of the samples were examined through potentiodynamic method in 0.9% NaCI solutions at $36.5\pm$$1^{\circ}C$ and corrosion surface was observed using SEM and XPS. The surface roughness of TiN coated bone plates was lower than that of tooth ash coated plates. The structure of TiN coated layer showed the columnar structure and tooth ash coated layer showed equiaxed and anisotrophic structure. The corrosion potential of the TiN coated specimen is comparatively high. The active current density of TiN and tooth ash coated alloy showed the range of about $1.0xl0^{-5}$ $A\textrm{cm}^2$, whereas that of the non-coated alloy was$ 1.0xl0^{-4}$ $A\textrm{cm}^2$. The active current densities of HA and TiN coated bone plates were smaller than that of non-coated bone plates in 0.9% NaCl solution. The pitting potential of TiN and HA coated alloy is more drastically increased than that of the non-coated alloy. The pit number and pit size of TiN and HA coated alloy decreased in compared with those of non-coated alloy. For the coated samples, corrosion resistance increased in the order of TiN coated, tooth ash coated, and non-coated alloy.

생체내 이식된 흡수성 봉합사들의 물리적 성질 변화와 조직 소견에 관한 연구 (The Mechanical Appearances and Microscopic Tissue Reactions of the Suture Materials in vivo)

  • 김남중;김명철
    • 한국임상수의학회지
    • /
    • 제13권2호
    • /
    • pp.184-194
    • /
    • 1996
  • A comparative study of three absorbable suture materials of chromic catgut, Dexon II (a polyglycolic acid suture with a polycaprolate coating system) and Coated Vicryl (a polyglactin 910 suture with a glycolide-lactide-calcium stearate coating system) was undertaken in terms of tensile strength, breaking elongation, appearances of the suture materials in the subcutaneous layer of rats and of tissue reaction in the intramuscular layer of rats. The initial tensile strength of chromic catgut and the tensile strength after 21 days were about 1.55 kg and 0.19 kg, respectively. Those of Dexon II were about 2.01 kg and 0. 20 kg, respectively. Those of Coated Vicryl were about 2.39 kg and 0.48 kg, respectively. Coated Vicryl showed the highest tensile strength among the three materials during the whole period. On the other hand, Dexon II showed the highest breaking elongation among the three materials during the first week. But the breaking elongation of Dexon II rapidly continuously decreased during the whole period. The appearances of the suture materials in the subcutaneous layer of rats showed that chromic catgut was the fastest among the three materials, whereas it formed comparatively much connective tissue. The intramuscular absorption rate and tissue reaction of Dexon II were similar to those of Coated Vicryl. The intramuscular absorption rate of these was fairly late when compared with chromic catgut. And the tissue reaction appearance of these showed the formation of a granuloma with foreign body giant cells, macrothages and epitheloid cells by the 28th day in the experimental period.

  • PDF

TiN 및 WC코팅된 치과용 어버트먼트 나사의 안정성 (Stability of TiN and WC Coated Dental Abutment Screw)

  • 손미경;이충환;정재헌;정용훈;최한철
    • 한국표면공학회지
    • /
    • 제41권6호
    • /
    • pp.292-300
    • /
    • 2008
  • Dental implant system is composed of abutment, abutment screw and implant fixture connected with screw. The problems of loosening/tightening and stability of abutment screw depend on surface characteristics, like a surface roughness, coating materials and friction resistance and so on. For this reason, surface treatment of abutment screw has been remained research problem in prosthodontics. The purpose of this study was to investigate the stability of TiN and WC coated dental abutment screw, abutment screw was used, respectively, for experiment. For improving the surface characteristics, TiN and WC film coating was carried out on the abutment screw using EB-PVD and sputtering, respectively. In order to observe the coating surface of abutment screw, surfaces of specimens were characterized, using field emission scanning electron microscope(FE-SEM) and energy dispersive x-ray spectroscopy(EDS). The stability of TiN and WC coated abutment screw was evaluated by potentiodynamic, and cyclic potentiodynamic polarization method in 0.9% NaCl solution at $36.5{\pm}1^{\circ}C$. The corrosion potential of TiN coated specimen was higher than those of WC coated and non-coated abutment screw. Whereas, corrosion current density of TiN coated screws was lower than those of WC coated and non-coated abutment screw. The stability of screw decreased as following order; TiN coating, WC coating and non-coated screw. The pitting potentials of TiN and WC coated specimens were higher than that of non-coated abutment screw, but repassivation potential of WC coated specimen was lower than those of TiN coated and non-coated abutment screws due to breakdown of coated film. The degree of local ion dissolution on the surface increased in the order of TiN coated, non-coated and WC coated screws.

Polycarbosilane이 코팅된 SiC와 Cu 혼합분말의 상압소결에 의한 Cu-30 vol% SiC 복합재료의 제조 (Fabrication of Cu-30 vol% SiC Composites by Pressureless Sintering of Polycarbosilane Coated SiC and Cu Powder Mixtures)

  • 김연수;권나연;정영근;오승탁
    • 한국재료학회지
    • /
    • 제26권6호
    • /
    • pp.337-341
    • /
    • 2016
  • Cu-30 vol% SiC composites with relatively densified microstructure and a sound interface between the Cu and SiC phases were obtained by pressureless sintering of PCS-coated SiC and Cu powders. The coated SiC powders were prepared by thermal curing and pyrolysis of PCS. Thermal curing at $200^{\circ}C$ was performed to fabricate infusible materials prior to pyrolysis. The cured powders were heated treated up to $1600^{\circ}C$ for the pyrolysis process and for the formation of SiC crystals on the surface of the SiC powders. XRD analysis revealed that the main peaks corresponded to the ${\alpha}$-SiC phase; peaks for ${\beta}$-SiC were newly appeared. The formation of ${\beta}$-SiC is explained by the transformation of thermally-cured PCS on the surface of the initial ${\alpha}$-SiC powders. Using powder mixtures of coated SiC powder, hydrogen-reduced Cu-nitrate, and elemental Cu powders, Cu-SiC composites were fabricated by pressureless sintering at $1000^{\circ}C$. Microstructural observation for the sintered composites showed that the powder mixture of PCS-coated SiC and Cu exhibited a relatively dense and homogeneous microstructure. Conversely, large pores and separated interfaces between Cu and SiC were observed in the sintered composite using uncoated SiC powders. These results suggest that Cu-SiC composites with sound microstructure can be prepared using a PCS coated SiC powder mixture.

Corrosion Behavior of Hard Coated Ti-Zr-N Film on the Tool Steels

  • Eun, Sang-Won;Choe, Han-Cheol
    • Corrosion Science and Technology
    • /
    • 제9권6호
    • /
    • pp.289-293
    • /
    • 2010
  • To investigate the corrosion behavior of tools steel surface in various coating film, the surface of hard coated Ti-Zr-N film on the tool steel by using magnetron-sputtering methods was researched using various experimental methods. STD 61 steels were manufactured by using vacuum furnace and solutionized for 1hr at $1050^{\circ}C$. Steel surface was coated with Ti-Zr-N film at $150^{\circ}C$ and 100W for 1h by using DC-sputtering equipment. Surface characteristics of Ti-Zr-N film coated specimens were investigated by OM, XRD, FE-SEM and nano-scratch tester. And corrosion behaviors of the coated specimen were investigated by polarization test and electrochemical impedance spectroscopy(EG&G Co, PARSTAT 2273. USA). It was found that Ti-Zr-N film coated sample had a thick coated layer and showed a good wear resistance and corrosion resistance of surface compared with ZrN and TiN coated sample. The corrosion resistance and mechanical property of Ti-Zr-N film coated STD 61 alloy increased as sputtering time increased.

PEG 물질을 도포한 QCM 가스센서의 열화특성 (Degradation Properties in the QCM Gas Sensors Coated with the PEG Materials)

  • 장경욱;김명호;이원재;김상걸;정동회;이준웅;이호식;김태완
    • 한국전기전자재료학회:학술대회논문집
    • /
    • 한국전기전자재료학회 2002년도 춘계학술대회 논문집 유기절연재료 전자세라믹 방전플라즈마 일렉트렛트 및 응용기술
    • /
    • pp.218-222
    • /
    • 2002
  • In the recognition of the gases using the quartz crystal microbalance (QCM) coated with the PEG film materials, it is important to obtain the recognition ability of gases, and the stability of PEG film coated above the QCM. Especially, the thickness of PEG film coated above the QCM is decreased according with the using circumstance and time of QCM gas sensor. Therefore, the sensing characteristics of PEG film is changed with these. In this paper, we coated the PEG materials varing with the blended amount of PVC(Poly Vinyl Chloride) and chloroform above QCM to obtain the sensitive and the stability of PEG film. We measured the degradation characteristics of QCM gas sensor in the ethyle acetate 50[%] concentration to show the properties of stability.

  • PDF