• 제목/요약/키워드: Coated material

검색결과 1,688건 처리시간 0.027초

지르코늄 코팅공구의 절삭특성 (Cutting Characteristics of the ZrN Coated Tool)

  • 설한욱;김주현
    • 한국공작기계학회논문집
    • /
    • 제15권1호
    • /
    • pp.17-22
    • /
    • 2006
  • Zirconium is widely applied in industrial area. In this study, the exeperiments are performed to investigate the differences in cutting characteristics of zirconium coated material which deposited on cutting tool using physical vapor deposition(PVD). For comparison, TiN coated tool is used to compare with zirconium coated tool. Experimental results were compared for tool wear, surface roughness and cutting force. The tool wear of PVD coated bites is affected by the various cutting conditions. This new stuff 'zirconium coated tool' wears $33\%$ less and improves surface roughness $23\%$ more in various cutting conditions. Cutting force is analyzed by using various workpiece, and the research strongly confirms that 'zirconium' remains better condition than 'titanium'. As a result 'zirconium' coated tool can be performed far better than 'titanium' coated tool on metal cutting.

콘크리트 슬래브 마감재료의 계면부착 거동에 관한 실험적 연구 (An experimental study on the adhesive properties of the top coated materials for concrete slab)

  • 이종열;손형호
    • 한국콘크리트학회:학술대회논문집
    • /
    • 한국콘크리트학회 1995년도 가을 학술발표회 논문집
    • /
    • pp.273-277
    • /
    • 1995
  • This study presents the physical and adhesive properties of the top coated materials for concrete slab. i.e, cement based top coated materials. epoxy mortar. The purpose of this study offers the investigation of construction factors to affect the quality of the coated materials over hardened concrete. The experimental results shows that the water content 3% of sand decline the strength and adhesive properties of epoxy mortar, on the other hand, dry surface and curing for cement based material.

  • PDF

도막재료에 따른 철근의 부착성능에 관한 실험적 고찰 (Experimental Study of Bond Properties Using Coated Bars)

  • 김영진
    • 한국복합재료학회:학술대회논문집
    • /
    • 한국복합재료학회 2003년도 추계학술발표대회 논문집
    • /
    • pp.211-216
    • /
    • 2003
  • Coated bars are protecting reinforcing bars from corrosion and enhancing durabilities of reinforced concrete structures are tested to evaluate corrosion protection properties. Tests are performed based on the relevant standards of ACI and ASTM, such as chemical resistance, salt water spray, salt crack test and chloride permeability test with the main variable of the coating thickness. Three type materials are tested by Polyethylene, epoxy and bare bar. Test results show good chemical protection property and chloride permeability. Polyethylene coated bar is good coating material than any other materials.

  • PDF

SM490B 용접부의 피로균열 성장 거동에 미치는 초고속 용사코팅 효과 (The Effect of High Velocity Oxygen Fuel Thermal Spray Coating on Fatigue Crack Growth Behavior for Welded SM490B)

  • 윤명진;최성종;조원익
    • 한국자동차공학회논문집
    • /
    • 제14권4호
    • /
    • pp.99-106
    • /
    • 2006
  • High velocity oxygen-fuel thermal spray coating of the WC-Co cermet material is a well-established process for modifying the surface properties of the structural components exposed to the corrosive and wear attacks, and also these coating are well-known method to improve the fatigue strength of material. In this study, HVOF coated SM490B are prepared to evaluation of the effect of coating on tension and fatigue crack growth behavior. The pre-crack of the fatigue crack growth test specimens machined at deposited material area, heat affected zone and boundary, respectively. Through these test, the following results are obtained: 1) Tensile strength was about 498 MPa, and fracture occurred on base metal area. 2) The fatigue crack of coated specimens propagated more rapidly than non-coated specimen in all specimens. 3) In the same coating thickness specimens, the specimens with pre-crack at boundary more rapidly propagated than the specimens with pre-crack at HAZ and deposited material area. These results can be used as basic data in a structural integrity evaluation of rolled SM490B weldments considering HVOF coating.

Al-Si 도금된 보론강과 Zn 도금된 DP강의 TWB 레이저 용접부 미세조직과 경도에 미치는 핫 스탬핑 열처리의 영향 (Effect of Hot-stamping Heat Treatment on Microstructure and Hardness in TWB Laser Joints of Al-Si-coated Boron Steel and Zn-coated DP Steel)

  • 정병훈;공종판;강정윤
    • 대한금속재료학회지
    • /
    • 제50권3호
    • /
    • pp.224-232
    • /
    • 2012
  • In this study, the effect of hot-stamping heat treatment on the microstructure and hardness of TWB(Tailor Welded Blank) laser joints in Al-Si-coated boron steel and Zn-coated DP(Dual Phase)590 steel was investigated. In the TWB joints without heat treatment, hardness profiles showed local hardness deviation near the fusion zone. However, there was no hardness deviation in the heat treated specimen and its hardness was higher than that of the one without the heat treatment, due to a fully martensite microstructure. In the TWB joints of both the boron and DP steels, the maximum hardnesses were observed at the HAZ(Heat Affected Zone) near the base metal, and the hardness decreased gradually to the base metal. In the heat treated joints, the hardnesses of the HAZ and the base metal of the boron steel side were similar to the maximum hardness of the weld, while those of the HAZ and the base metal of the DP steel side were higher than the maximum hardness.

실링이 플라즈마 스프레이 코팅된 알루미나 코팅재의 내부식성에 미치는 영향 (Effect of Sealing on the Corrosion Resistance of Plasma-Sprayed Alumina Coatings)

  • 권의표;김세웅;이종권
    • 한국재료학회지
    • /
    • 제32권10호
    • /
    • pp.442-447
    • /
    • 2022
  • Sealing treatment is a post-surface treatment of the plasma spray coating process to improve the corrosion resistance of the coating material. In this study, the effect of the sealing on the corrosion resistance and adhesive strength of the plasma spray-coated alumina coatings was analyzed. For sealing, an epoxy resin was applied to the surface of the coated specimen using a brush. The coated specimen was subjected to a salt spray test for up to 48 hours and microstructural analysis revealed that corrosion in the coating layer/base material interface was suppressed due to the resin sealing. Measurement of the adhesive strength of the specimens subjected to the salt spray test indicated that the adhesive strength of the sealed specimens remained higher than that of the unsealed specimens. In conclusion, the resin sealing treatment for the plasma spray-coated alumina coatings is an effective method for suppressing corrosion in the coating layer/base material interface and maintaining high adhesive strength.

Coated conductor에서 임계전류의 불균일 (A unhomogeneity of critical current at the long length coated conductors)

  • 이남진;오상수;김호섭;하동우;하홍수;고락길;김태형;문승현;염도준
    • 한국전기전자재료학회:학술대회논문집
    • /
    • 한국전기전자재료학회 2009년도 춘계학술대회 논문집
    • /
    • pp.1-2
    • /
    • 2009
  • The high critical current ($I_c$, A) of SmBCO coated conductor in a magnetic field, the high production rate and the high material yield are promising for applications. The inhomogeneity of Ie at the long length coated conduct is very important problem for electric application. So we researched the reason of inhomogeneity of $I_c$ at long length tape prepared by batch type co-evaporation system called by EDDC. The long length SmBCO coated conductors were developed on $LaMnO_3/IBAD-MgO/Y_2O_3/Al_2O_3$/Hastelloy C276 template. The distribution of $I_c$ are from 0 to 397 A/cm at 77 K and self field. We have studied the microstructures of these films by using SEM, EDS and X-ray diffraction. The XRD and composition by EDS results of SmBCO film reveals subtle difference. But, the microscopic observation by SEM show the microcrack at the sample with low $I_c$.

  • PDF

콜라겐을 첨가한 폴리우레탄 코팅직물의 물성 (Physical properties of PU coated fabric with collagen)

  • 백천의;유효선
    • 한국의류학회지
    • /
    • 제23권6호
    • /
    • pp.800-808
    • /
    • 1999
  • The demand for PU coated synthetic leather is increasing as a high fashion material. But it has some faults of water vapor permeability surface tacky property and static electricity. Therefore the purpose of this study was the produce of PU coated fabric added collagen with hydrophilic property and soft touch. In the PU coated fabric water vapor permeability water vaper absorption and frictional electronic voltage were investigated surface bending and compression properties were also examined by the use of KES-FB System. The followings were the results of this study. 1. There was no Cr in the collagen so that Cr was not treated in the collagen. 2. The surface and cross sectional layer of PU coated fabric with collagen were highly developed by micro porous structure. 3. The water vapor permeability of PU coated fabric was increased as collagen concentration increased. 4. The water vapor absorption of PU coated fabric was increased as collagen concentration increased. 5. The frictional electronic voltage of PU coated fabric was decreased in accordance with the increase of collagen concentration. Especially it effectively decreased by the use of only 5% collagen concentration. 6,. The bending and compression properties of PU coated fabric were increased in accordance with the increase of collagen concentration so that it became stiff. 7. The Value of MIU, SMD was decreased in accordance with the increase of collagen concentration so that the PU coated fabric became smooth.

  • PDF

Stabilizer-free 초전도 선재를 이용한 한류 소자 제작 및 특성 시험 (Fabrication and characterization of fault current limiting devices made of stabilizer-free coated conductors)

  • 임성우;박충렬;유승덕;김혜림;현옥배
    • 한국전기전자재료학회:학술대회논문집
    • /
    • 한국전기전자재료학회 2009년도 하계학술대회 논문집
    • /
    • pp.371-371
    • /
    • 2009
  • For the application of superconducting wires to fault current limiting devices, it is required that they have a high rated voltage when a fault occurs. Stabilizer-free coated conductors, particularly, shows a good performance for the high rated voltage, which is beyond 0.6 V/cm. In this study, using the stabilizer-free coated conductors, we made fault current limiting devices and examined their characteristics. Fault current limiting devices were fabricated with a shape of the cylinder of a mono-filar coil winding. Stabilizer-free coated conductors were wound along the mono-filar coil line and the terminal parts between the wire and metal were soldered using In solder. Two kinds of devices were fabricated by a different method in the terminal joint, one was made by a soldering and the other was made by a soldering-free joint. Critical currents and resistance at the joint parts were measured. In addition, long-time current flowing tests were also carried out for the characterization of the fault current limiting devices.

  • PDF

고온초전도 coated conductor의 임계전류 측정 표준화 연구 I (A study of standardizing Critical-Current Measurements for coated conductor I)

  • 오상수;이남진;김호섭;염도준
    • 한국전기전자재료학회:학술대회논문집
    • /
    • 한국전기전자재료학회 2009년도 하계학술대회 논문집
    • /
    • pp.363-364
    • /
    • 2009
  • 본 연구는 IEC/TC 90 규격을 참조하여 Cu stabilizer/Ag/$LaMnO_3$/IBAD-MgO/$Y_2O_3$/$Al_2O_3$/Hastelloy C276/Cu stabilizer의 구조를 가지는 coated conductor의 DC 임계 전류의 결정에 대한 사전 연구를 위해 (1) 시편의 냉각시간, (2) 전류 선의 용량을 변화하여 임계 전류의 변화를 관찰하여 다음과 같은 결과를 얻었다. (1) 5분 이상의 시편 냉각시간은 COV가 약 0.4% 정도로 거의 임계 전류 결정에 영향을 주지 않았으며, 냉각 시간이 길면 길수록 임께 전류 이하에서 전압의 기저면이 낮아지는 경향을 보였다. (2) 전류 선의 용량이 클수록 임계 전류 이하에 전압의 기저면이 낮아지는 경향을 보였다.

  • PDF