• 제목/요약/키워드: Coated Bars

검색결과 56건 처리시간 0.02초

섬유복합재봉(FRP ROD)과 고강도 모르터를 이용한 철근 콘크리트 구조물의 휨 보강공법(MFRI) 공법 (Reinforcing System(MFRI) for Concrete Structure using FRP ROD & High-performance Mortar)

  • 배기선;박상훈;이상욱
    • Composites Research
    • /
    • 제18권4호
    • /
    • pp.59-65
    • /
    • 2005
  • This report is on the Reinforcing System(MFRI) for Concrete Structure using FRP ROD & High-Performance Mortar. The main characteristic of this system is as follow. First, the fiber rods in this system have seven times greater tensile strength than general reinforcing steel bars(re-bar) and the weight is a fifth lighter. Camels coated on the fiber rods' surfaces to improve adhesive strength and pull-out strength. Second, high strength shotcrete mortar is has very good workability and low rebound rate. After installing the Fiber Rods, Shotcrete mortar Is applied or sprayed to finish reinforcement. Finally, MFRI system has excellent fire-resisting performance and sogood tolerance against external environment by inserting fiber rods and reinforcing materials into mortar which has high compressive strength. It is applied to bridge slab, utility box and tunnel of civil engineering works, and beam and slab of building structures.

부식촉진시험에 의한 콘크리트 내의 철근의 부식특성에 관한 실험적 연구 (An Experimental Study on the Corrosion Characteristics of Reinforcing Steel in Concrete by the Accelerated Corrosion Test)

  • 배수호;정영수;김년산;권영우;권혁진
    • 한국콘크리트학회:학술대회논문집
    • /
    • 한국콘크리트학회 2000년도 가을 학술발표회논문집(I)
    • /
    • pp.503-507
    • /
    • 2000
  • The corrosion protection methods of reinforcing steel in concrete are the various methods such as increasing thickness of cover concrete, using of reinforcing bars coated with epoxy, dosage of corrosion inhibitor as concrete admixture, cathodic protection method and etc. In this study, the performance of corrosion protection was investigated for the test specimens using corrosion inhibitors and cathodic protection, respectively. For this purpose, the accelerated corrosion tests for reinforcing steel were conducted according to the periodic cycles(140 days) of wetting($65^{\circ}C$, 90% R.H) and drying period($15^{\circ}C$, 65% R.H) for the test specimens. As a result, it can be concluded from the test that the effect of corrosion inhibitor was found to be variable with products, the cathodic protection method was found to be independent of salt concentration in concrete.

  • PDF

방청제에 의한 콘크리트 내의 철근 방식법에 관한 실험적 연구 (An Experimental Study on the Corrosion Protection Method of Reinforcing Steel in Concrete by Using Corrosion Inhibitor)

  • 배수호;정영수;권영우;김년산;권혁진
    • 한국콘크리트학회:학술대회논문집
    • /
    • 한국콘크리트학회 2000년도 봄 학술발표회 논문집
    • /
    • pp.710-713
    • /
    • 2000
  • The corrosion protection methods of reinforcing steel in concrete are the various methods such as increasing thickness of cover concrete, using of reinforcing bars coated with epoxy, dosage of corrosion inhibitor as concrete admixture, cathodic protection method and etc. The most economical method of them will be the corrosion protection method using corrosion inhibitor as concrete admixture. Therefore, the purpose of this research is to investigate the performance of corrosion protection of ordinary strength and high strength concrete using corrosion inhibitor, respectively. For this purpose, after manufacturing ordinary strength and high strength concrete with and without corrosion inhibitor, the accelerated corrosion tests for reinforcing steel were conducted according to the periodic cycles (140 day) of wetting ($65^{\circ}C$, 90% R.H.) and drying period ($15^{\circ}C$, 65% R.H.). As a result, th high strength concrete using corrosion inhibitor showed an excellent performance of corrosion protection.

  • PDF

압착(壓搾).농축식품(濃縮食品)의 시제(試製) (Development of Nutritionally Defined and Compressed Foods)

  • 조재선;송석훈;이상규;정윤수;권태완
    • 한국식품과학회지
    • /
    • 제7권3호
    • /
    • pp.141-147
    • /
    • 1975
  • 불의(不意)의 사고(事故)나 정상적(正常的)인 취사급식(炊事給食)이 불가능(不可能)한 상황(狀況)에 대비(對備)하여 휴대취식(携帶取食)할 수 있는 압착(壓搾) 농축식품(濃縮食品)을 시제(試製)하였다. 즉, 원료(原料)는 포도당 전분 쌀 보리 카세인소오다 분유 및 식물성식용유등(植物性食用油等)을 사용하였으며, 원료조성(原料組成)에 있어서 구급상황하(救急狀況下)에서 사용될 1,2형은 탄수화물(炭水化物)을 주(主)로 하되 적량(適量)의 단백질(蛋白質)과 지방(脂肪)을 배합(配合)함으로서 체내수분(體內水分)을 절약(節約)할 수 있도록 조정하였다. 이들 시제품의 용적을 축소하기위하여 $4,000{\sim}7,000psi$ 로 압착성형 하였으며, 특히 3,4형은 결착제 로서 카세인소오다를 사용함으로써 취식성(取食性)을 개선(改善)하였다. 또한 제품(製品)의 파손율(破損率)을 줄이고 저장성(貯藏性)을 높이기 위하여 피막제(被膜劑)로 제품표면을 피막(被膜)하였다. 이와같이 만든 제품(製品)은 g 당 열량(熱量)이 $4.0{\sim}4.4Cal$, $1cm^3$$4.2{\sim}4.9\;Cal$ 이었으며 다소 딱딱한 감이 있기는 하나 휴대 취식성이 좋았다.

  • PDF

Impact of aggressive exposure conditions on sustainable durability, strength development and chloride diffusivity of high performance concrete

  • Al-Bahar, Suad;Husain, A.
    • Structural Monitoring and Maintenance
    • /
    • 제2권1호
    • /
    • pp.35-48
    • /
    • 2015
  • The main objective of this study is to evaluate the long-term performance of various concrete composites in natural marine environment prevailing in the Gulf region. Durability assessment studies of such nature are usually carried out under aggressive environments that constitute seawater, chloride and sulfate laden soils and wind, and groundwater conditions. These studies are very vital for sustainable development of marine and off shore reinforced concrete structures of industrial design such as petroleum installations. First round of testing and evaluation, which is presented in this paper, were performed by standard tests under laboratory conditions. Laboratory results presented in this paper will be corroborated with test outcome of ongoing three years field exposure conditions. The field study will include different parameters of investigation for high performance concrete including corrosion inhibitors, type of reinforcement, natural and industrial pozzolanic additives, water to cement ratio, water type, cover thickness, curing conditions, and concrete coatings. Like the laboratory specimens, samples in the field will be monitored for corrosion induced deterioration signs and for any signs of failureover initial period ofthree years. In this paper, laboratory results pertaining to microsilica (SF), ground granulated blast furnace slag (GGBS), epoxy coated rebars and calcium nitrite corrosion inhibitor are very conclusive. Results affirmed that the supplementary cementing materials such as GGBS and SF significantly impacted and enhanced concrete resistivity to chloride ions penetration and hence decrease the corrosion activities on steel bars protected by such concretes. As for epoxy coated rebars applications under high chloride laden conditions, results showed great concern to integrity of the epoxy coating layer on the bar and its stability. On the other hand corrosion inhibiting admixtures such as calcium nitrite proved to be more effective when used in combination with the pozzolanic additives such as GGBS and microsilica.

Effects of Air Void at the Steel-Concrete Interface on the Corrosion Initiation of Reinforcing Steel in Concrete under Chloride Exposure

  • Nam Jin-Gak;Hartt William H.;Kim Kijoon
    • 콘크리트학회논문집
    • /
    • 제17권5호
    • /
    • pp.829-834
    • /
    • 2005
  • A series of reinforced G109 type specimens was fabricated and pended with a 15 weight percent NaCl solution. Mix design variables included 1) two cement alkalinities (equivalent alkalinities of 0.32 and 1.08), 2) w/c 0.50 and 3) two rebar surface conditions (as-received and wire-brushed). Potential and macro-cell current between top and bottom bars were monitored to determine corrosion initiation time. Once corrosion was initiated, the specimen was ultimately autopsied to perform visual inspection, and the procedure included determination of the number and size of air voids along the top half of the upper steel surface. This size determination was based upon a diameter measurement assuming the air voids to be half spheres or ellipse. The followings were reached based upon the visual inspection of G109 specimens that were autopsied to date. First, voids at the steel-concrete interface facilitated passive film breakdown and onset of localized corrosion. Based upon this, the initiation mechanism probably involved a concentration cell with contiguous concrete coated and bare steel serving as cathodes and anodes, respectively. Second, the corrosion tended to initiate at relatively large voids. Third, specimens with wire-brushed steel had a lower number of voids at the interface for both cement alkalinities, suggesting that air voids preferentially formed on the rough as-received surface compared to the smooth wire brushed one.

롤투롤 전자인쇄 건조공정의 공기역학적 특성분석 (Analysis on Aerodynamic Characteristics of Drying Process in R2R Printed Electronics)

  • 서용호;장영배;김창완
    • 한국정밀공학회지
    • /
    • 제27권3호
    • /
    • pp.95-103
    • /
    • 2010
  • Roll to Roll (R2R) is one of the most promising production technologies in the printed electronics such as OLEDs, e-paper, backplanes, RFID because this technology can save production cost and increase production speed. Printed electronics includes various processes such as printing, drying, winding, unwinding, and so on. In printed electronics R2R system, air-flotation oven is employed for drying process. Therefore, it is essential to introduce efficient and fast drying process when printing is finished. This paper considers the analysis of drying process in R2R that involves hot air flow. Air-flotation oven consists of non-contact supports and drying of coated web materials such as plastic films and paper. In this paper, experimental results and numerical analysis of pressure-pad air bar are investigated. The aerodynamic characteristics of pressure-pad air bar are numerically calculated using computational fluid dynamics (CFD) approach. Then the measured values of the aerodynamic forces for air bars are compared with those of CFD analysis.

R-22 냉매 분위기하에서 스크롤 압축기 스러스트 베어링의 윤활특성 평가 (Performance Evaluation of Thrust Slide-Bearing of Scroll Compressors under R-22 Environment)

  • 조상원;김홍석;이재근;이형국;이병철;박진성
    • 대한설비공학회:학술대회논문집
    • /
    • 대한설비공학회 2006년도 하계학술발표대회 논문집
    • /
    • pp.590-595
    • /
    • 2006
  • This paper presents the friction and anti-wear characteristics of nano-oil with a mixture of a refrigerant oil and carbon nano-particles in the thrust slide-bearing of scroll compressors. Frictional loss in the thrust slide-bearing occupies a large part of total mechanical loss in scroll compressors. The characteristics of friction and anti-wear using nano-oil are evaluated using the thrust bearing tester for measuring friction surface temperature and the coefficient of friction at the thrust slide-bearing as a function of normal loads up to 4,000 N and orbiting speed up to 3,200 rpm. It is found that the coefficient of friction increases with decreasing orbiting speed and normal force. The friction coefficient of carbon nano-oil is 0.015, while that of pure oil is 0.023 under the conditions of refrigerant gas R-22 at the pressure of 5 bars. It is believed that carbon nano-particles can be coated on the friction surfaces and the interaction of nano-particles between surfaces can be improved the lubrication in the friction surfaces. Carbon nano-oil enhances the characteristics of the anti-wear and friction at the thrust slide-bearing of scroll compressors.

  • PDF

하이브리드형 방식 폴리머 시멘트 슬러리의 인장특성 및 접착성 (Tensile Properties and Adhesion of Hybrid-Type Anti-Corrosion Polymer Cement Slurry)

  • 조영국
    • 콘크리트학회논문집
    • /
    • 제20권5호
    • /
    • pp.635-642
    • /
    • 2008
  • 건설구조물에서 보통철근의 부식을 방지하기 위하여 에폭시 도장 철근이 널리 사용되고 있다. 그러나 에폭시 도장철근은 성능과 코스트 면에서 불리하며, 특히 취성적이고, 부착성 및 현장 가공성 등의 취약점 때문에 현장에서 사용상의 제약을 받고 있다. 본 연구는 에폭시 도장 철근을 대체할 수 있는 도장재료로서 유기계 폴리머와 시멘트의 무기계를 혼합한 하이브리드 (hybrid)형 폴리머 시멘트 슬러리를 개발하기 위한 것으로서, 특히 인장특성과 접착성에 관한 연구이다. 폴리머 시멘트 슬러리는 4종류의 폴리머 디스퍼션과 혼화재로서 플라이애쉬와 실리카퓸을 혼입하여 제작되었으며, 도장두께, 인장특성, 접착성 및 내굴곡성 시험을 실시하였다. 연구결과, 폴리머 시멘트 슬러리의 점도는 폴리머 디스퍼션의 종류에 따라 크게 영향을 받았으며, 플라이애쉬를 혼입함에 따라 약간 감소하였다. 또한 폴리머-결합재비 100%에서 폴리머 시멘트 슬러리의 적정 도장두께가 확보되었으며, 도장두께는 물-결합재비와 폴리머-결합재비에 의해 다양화 할 수 있었다. 철근의 도장을 위한 적정 도장 두께는 부착강도, 접착성 및 내굴곡성을 고려할 때, 보통 $150{\sim}250{\pm}50{\mu}m$ 범위였다. 본 연구에서 폴리머 시멘트 슬러리의 인장특성 및 접착성, 그리고 도장강의 내굴곡성은 양호하게 평가되어, 향후 에폭시 도장철근을 대체할 수 있는 재료로 사용가능성을 확인하였다.

GFRP Rebar 보강 콘크리트 보의 급속노화환경에서의 휨 거동에 관한 연구 (Flexural Behaviors of GFRP Rebars Reinforced Concrete Beam under Accelerated Aging Environments)

  • 박연호;최열
    • 콘크리트학회논문집
    • /
    • 제25권2호
    • /
    • pp.137-144
    • /
    • 2013
  • 철근콘크리트(reinforced concrete) 구조부재에서 철근의 부식으로 인한 문제점을 개선하고자 섬유보강 복합재료(FRP) 보강근(rebar)을 사용하는 것에 대한 연구가 꾸준히 진행되어져 오고 있다. 하지만 이러한 FRP 보강근을 사용한 콘크리트 부재의 환경에 대한 장기거동에 대한 연구가 아직도 미흡한 수준이다. 이 연구는 GFRP(glass fiber reinforced polymer) 보강근을 사용한 콘크리트 부재를 온도 약 $46^{\circ}C$와 습도가 80%인 인위적인 실험실에서 최대 300일까지 노출시킨 후의 장기 거동에 대한 실험적 연구를 제시하였다. 비교를 위하여 두가지 서로 다른 GFRP 보강근과 철근을 보강한 콘크리트 보 시험체를 제작하였다. 실험 결과, 장기 노출환경에서도 GFRP 보강근을 보강한 콘크리트 보 시험체의 파괴형태는 철근 보강 콘크리트 보시험체와 매우 유사한 파괴형태를 나타내었으며, 노출 시간에 따른 하중저항 감소값은 철근이 보강된 경우가 GFRP 보강근이 보강된 경우보다 하중저항 감소값이 크게 일어났다. 또한 GFRP 보강근 보강 콘크리트 보 시험체를 설계할 시에는 철근 보강보다 취성파괴에 대한 충분한 대비가 요구됨을 알 수 있었다. 그리고 압축파괴에 대한 변형도 계수(deformability factor)는 모든 경우에서 노출시간에 관계없이 큰 변화가 없음을 알 수 있었다.