• Title/Summary/Keyword: Coagulation test

Search Result 210, Processing Time 0.03 seconds

Influencing Factors on NOM Removal using Blended Coagulants (혼합응집제에 의한 자연유기물질 제거에 미치는 영향 인자)

  • 명복태;우달식;최종헌;문철훈;이윤진;조영태;조관형;남상호
    • Journal of environmental and Sanitary engineering
    • /
    • v.16 no.3
    • /
    • pp.96-103
    • /
    • 2001
  • This study was carried out to investigate the major factors for the removal of NOMs (Natural Organic Matters) by alum ferric chloride and blended coagulants that consisted of alum and ferric chloride. Investigated factors were pH, the dosage of coagulant, alkalinity, hardness and bloc strength. The particle size contained in the test water came from the Han River was also measured. DOC(Dissolved Organic Carbon) removal at pH 6 was two to three times higher than at pH 8.5. The blended coagulant showed 9 to 10 percent higher DOC removal efficiency and 2 to 4 percent higher turbidity under the same condition. Alkalinity consumption of alum, ferric chloride and blended coagulant was 81%, 90% and 86% of theoretical value, respectively. The limit concentration of alkalinity to avoid pin floe was 10 mg $CaCO_3/L$ when alum was used. Hardness had no apparent effect on coagulation. The residual turbidity and $UV_{254}$ showed a tendency of increasing with floc strength($sec^{-1}$) increase. The order of floe strength was the following; alum >blended coagulant > ferric chloride. The particle counter test showed 89 percent of the small particle size(SPS, $1~5{\;}{\mu}textrm{m}$) and 11 percent of the medium to large particle size(M.LPS, $5~125{\;}{\mu}textrm{m}$). At PH7.85, the particle removal efficiencies of SPS($1~5{\;}{\mu}textrm{m}$) and M.LPS($5~125{\;}{\mu}textrm{m}$) in the coagulation process were 81% and 95%, respectively.

  • PDF

Study on the Antiinflammatory, Anticoagulative and Analgesic effects of Sambitang in the experimental animal model (삼비탕(三痺湯)의 항염(抗炎), 항응고(抗凝固) 및 진통효과(鎭痛效果)에 대(對)한 연구(硏究))

  • Rhy, Jun-Kiu;Lee, Young-Goo;Moon, Byung-Soon
    • The Journal of Internal Korean Medicine
    • /
    • v.19 no.2
    • /
    • pp.88-106
    • /
    • 1998
  • This study was designed to elucidate the antiinflammatory, cardiovascular, antithrombotic, and analgesic effect of Sambitang. The antiinflammatory effects was measured by the method of carrageenin induced edema, protein leakage test using CMC-pouch, and the effect of Sambitang on the cardiovascular system was observed by the change of flow rate of Ringer solution in the vascular system in the ear of rabbit, and the contraction and dilatation of rat tail artery. Death rate, platelet aggregation, plasma coagulation activity was observed for the measurement of the anticoagurative effect of Sambitang, and the analgesic effect was measured by the acetic acid method and hot plate method. The result was as follows: 1. Sambitang administration, edema and protein leakage was significantly decreased. 2. The drug increased the auricular blood flow in rabbit. 3. The drug relaxed the artery contraction by pretreated norepinephrine in rat. 4. The drug inhibited the death rate of mouse which was led to thromboembo- lism by serotonin and collagen. 5. The drug inhibited the platelet aggregation in rat. 6. The drug prolonged the prothrombin time and activated partial thromboplastin time on the test of plasma coagulation factor activity in rat, but was not valuable. 7. The slight anagesic effect of Sambitang extract was confirmed by the observation of writhing syndrome, paw licking time, and escape time.

  • PDF

Removal Characteristics of Total Coliforms in a Rotating Activated Bacillus Contactor Process (회전식 부착 바실러스를 이용한 하수고도처리 공정에서의 총대장균군 제거 특성)

  • Kim, Eung-Ho;Cho, Yeon-Je;Park, Seong-Joo;Shin, Kwang-Soo;Yim, Soo-Bin;Park, Hyun-Ju
    • Journal of Korean Society on Water Environment
    • /
    • v.21 no.1
    • /
    • pp.73-78
    • /
    • 2005
  • This study was performed to examine the disinfection capability of a Rotating Activated Bacillus Contactor (RABC) system, in which the predominant species, Bacillus sp. was expected to have a removal or inactivation effect of total coliforms. In a settling test with mixtures of E. coli and Bacillus sp., a high removal of E. coli was observed at $20{\sim}40^{\circ}C$, while insignificant removal at $10^{\circ}C$. In a batch test, a 4.5% addition of Bacillus sp. to activated sludge considerably enhanced the removal effect of total coliforms, indicating Bacillus sp. played an important role in improving the settlability of the sludge and coliforms. In a pilot scale RABC system, the concentration of total colifroms reduced remarkably in the settling tank, suggesting that total coliforms in the RABC process were eliminated through coagulation and precipitation, probably due to extracellular polymeric substance (EPS) of Bacillus sp. The fraction of Bacillus sp. in the total cell count in the RABC process was in the range of 4.5%~6.3%. The majority (75%) of the Bacillus sp. in the RABC process was Bacillus subtilis which is known to enhance coagulation and precipitation by producing EPS. Hence, an adoption of a RABC process might be able to eliminate the disinfection unit process from a wastewater treatment system.

Evaluation of Solids Removal Characteristics on Sewage Treatment Plants Using T-P sludge Return into the Primary Settling Tank (총인슬러지의 1차 침전지 반송에 따른 하수처리장 고형물 제거특성 연구)

  • Kim, Jong-Oh;Jung, Dong-Gi;Kwon, Hye-Jeong;Hwang, Joon-Seok
    • Journal of Korean Society of Water Science and Technology
    • /
    • v.26 no.6
    • /
    • pp.73-80
    • /
    • 2018
  • In this study, the solids removal characteristics using T-P sludge generated from PACl coagulation were analyzed by laboratory scale and full scale experiment. As the amounts of T-P sludge injection into the raw sewage influent increased at the rate of 0, 1, 2, 3, 4 %, the suspended solids concentrations after 20 minutes setting test decreased to 210, 137, 91, 64, 43 mg/L, respectively. The filtration time required for dewatering test of the raw sewage influent decreased to 982, 728, 658, 581, 492 sec for 0, 1, 2, 3, 4% of T-P sludge injection, respectively. As the amounts of PACl coagulant into the effluent from final setting tank increased at 0, 10, 20, 30, 40 mg/L, the required filtration times for T-P sludge increased into 12.3, 41.7, 53.7, 67.2, 79.5 sec and the dewaterability of T-P sludge decreased. After T-P sludge returned into the primary settling tank on J-si sewage treatment plants, the effluent concentrations of COD, SS, T-N and T-P from primary settling tank into bioreactor decreased by 35.9, 27.9, 22.2, and 52.6% due to the coagulation effects of the T-P sludge. Finally, it was found that the return of T-P sludge into the primary settling tank could result into the sludge reduction having a lower water content of 3.03% p than in case of the only T-P sludge dehydration.

Stability Evaluation of National Reference Standards for Blood Products in Korea

  • Park, Tae Jun;Choi, Chan Woong;Oh, Ho Kyung;Kim, Jae Ok;Kim, Byung Kuk;Kang, Hyun Kyung;Kwon, Eun Jeong;Gweon, Eun Jeong;Park, Sang Jin;Kang, Ho Il;Jung, Ki Kyung;Park, Sang Mi;Kim, Ji Hye;Han, Ki Won;Jeong, Ja Young
    • Toxicological Research
    • /
    • v.33 no.3
    • /
    • pp.225-231
    • /
    • 2017
  • National reference standards (NRSs) for biologics are established through potency estimation by a multi-center joint study of standard materials used in the approval process for national lot release and quality control of vaccines, blood products, and other biologics. In this study, a stability evaluation was conducted to determine whether the potency of NRSs for six blood products was being maintained at a consistent level in Korea. The present study conducted real-time stability tests via in-vivo/in-vitro bioassay on NRSs for blood coagulation factor VIII concentrate (2nd standard), antithrombin concentrate, prekallikrein activator, anti-hepatitis B immunoglobulin, blood coagulation factor IX concentrate, and anti-tetanus human immunoglobulin, as well as a trend analysis using cumulative annual results. The real-time stability test results showed that the mean potency of six NRSs was all within the control limit. In the trend analysis, the potency of NRS for blood coagulation factor VIII concentrate (2nd standard) showed a decreasing trend, while the potency of all other products had been stably maintained. The present study confirmed that the mean potency of NRSs for six blood products had been stably maintained in Korea. The findings of the present study establish a foundation that can ensure the quality of NRSs for biologics in Korea, and it is expected to make a major contribution to the supply of high-quality biologics.

Removal of Phthalate Esters in Advanced Water Treatment Unit Processes (고도정수처리단위공정에서 Phthalate Esters의 제거)

  • Hong, Sung-Hee;Han, Gae-Hee;Lee, Chan-Hyung;Lee, Shun-Hwa
    • Journal of Korean Society of Environmental Engineers
    • /
    • v.27 no.5
    • /
    • pp.461-467
    • /
    • 2005
  • Phthalate esters is recently considered as an environmental pollutant. This study investigated removal methods of phthalate esters in water environment. On tap water treatment condition with batch test, removal efficiency of coagulation precipitation of one oxidation were $26.6{\sim}33.8%$ and $10{\sim}15%$, respectively. Phthalate esters was effectively removed by the activated carbon adsorption process on tap water treatment condition. The operation of raw water with EBCT of 10 minutes on continuous process satisfied the standard of drinking water by the WHO and US EPA when the concentration of phthalate esters was $100\;{\mu}g/L$. On pilot plant test, coagulation precipitation process got $32{\sim}44%$ of removal efficiency, sand filtration process $6{\sim}10%$ and ozone oxidation process $8{\sim}10%$, respectively. DEP, DBP, BBP and DEHP were not detected after the raw water was processed with activated carbon. The actual survey of phthalate esters removal by advanced water treatment showed that $29{\sim}76%$, $3{\sim}29%$ and $17{\sim}22%$ of phthalate esters were removed on coagulation precipitation process, sand filtration and ozone oxidation process, respectively. DEP, DBP, BBP and DEHP were not detected after the raw water was processed with activated carbon.

Production of Alternative Coagulant Using Waste Activated Alumina and Evaluation of Coagulation Activity (폐촉매 부산물로부터 대체 응집제 제조 및 응집성능 평가)

  • Lee, Sangwon;Moon, Taesup;Kim, Hyosoo;Choi, Myungwon;Lee, Deasun;Park, Sangtae;Kim, Changwon
    • Journal of Korean Society of Environmental Engineers
    • /
    • v.36 no.7
    • /
    • pp.514-520
    • /
    • 2014
  • In this study, the production potential of alternative coagulant ($Al_2(SO_4)_3$ solution) having the identical coagulation activity with respect to the commercial coagulant was investigated. The raw material of alternative coagulant was a spent catalyst including aluminium (waste activated alumina) generated in the manufacturing process of the polymer. The alternative coagulant was produced through a series of processes: 1) intense heat and grinding, 2) chemical polymerization and substitution with $H_2SO_4$ solution, 3) dissolution and dilution and 4) settling and separation. To determine the optimal operating conditions in the lab-scale autoclave and dissolver, the content of $Al_2O_3$ in alternative coagulant was analyzed according to changes of the purity of sulfuric acid, reaction temperature, injection ratio of sulfuric acid and water in the dissolver. The results showed that the alternative coagulant having the $Al_2O_3$ content of 7~8% was produced under the optimal conditions such as $H_2SO_4$ purity of 50%, reaction temperature of $120^{\circ}C$, injection ratio of $H_2SO_4$ of 5 times and injection ratio of water of 2.3 times in dissolver. In order to evaluate the coagulation activity of the alternative coagulant, the Jar-test was conducted to the effluent in aerobic reactor. As a result, in both cases of Al/P mole of 1.5 and 2.0, the coagulation activity of the alternative coagulant was higher than that of the existing commercial coagulant. When the production costs were compared between the alternative and commercial coagulant through economic analysis, the production cost reduction of about 50% was available in the case of the alternative coagulant. In addition, it was identified that the alternative coagulant could be applied at field wastewater treatment plant without environmental problem through ecological toxicity testing.

Characteristics of coagulants dispersion within In-Line Orifice Mixer (In Line Orifice Mixer에서의 응집제 확산분포 특성)

  • Lim, Kyeong-Ho;Park, Young-Oh;Park, Dae-Jin;Park, No-Suk;Ko, Tae-Kon
    • Journal of Korean Society of Water and Wastewater
    • /
    • v.22 no.6
    • /
    • pp.689-696
    • /
    • 2008
  • In a water treatment process a complete and homogeneous dispersion of the coagulants in the raw water could be most important factor. This research was performed to evaluate coagulation performance of the in-line-orifice mixer which was recently introduced as a rapid mixing device. The test was to determine the actual coagulant dispersion distribution on the overall cross-section at a distance of 1.6~3D from the chemical injection point by measuring zeta potential. From the results of zeta potential test, it was shown that the coagulant dispersion within the in-line orifice mixer was occurred very unevenly. The results have confirmed that it is necessary to increase the velocity of coagulants injection or pressurized water rates, in order to reduce nonuniform distribution of chemicals.

Potency Assay of Factor Ⅷ : C Concentrates using the Chromogenic and Clotting Assay (합성기질 및 응고시간을 이용한 혈액응고 제 8인자 역가측정법)

  • 강혜나;김순남;허숙진;홍성화
    • YAKHAK HOEJI
    • /
    • v.45 no.5
    • /
    • pp.476-483
    • /
    • 2001
  • The clotting assay was replaced by the chromogenic substrate assay which is recommended by the European Pharmacopoeia (EP) and the Scientific and Standardization Committee of the International Society on Thrombosis and Haemostasis based on the reliability convenience and simplicity of the chromogenic assay, A correlation study was carried out with a one-stage factor Ⅷ : C clotting assay and the performance of the chromogenic assay was evaluated using two test kits that fulfilled the requirements of EP for factor Ⅷ concentrates test. Although chromogenic assay has partly differences in measurement principle and standardization, this assay has a high correlation with clotting assay in various types of factor Ⅷ concentrates and factor Ⅷ standard. We conclude that the chromogenic assay for factor Ⅷ : C concentrates correlates well with the clotting assay and shows good analytical performance.

  • PDF

Needs of Preoperative Blood Sample Test in Surgical Extraction: Suggestion of New Policy (치아 외과적 발거 전 혈액검사의 필요성과 이의 정책적 제시)

  • Seo, Mi Hyun;Kim, Soung Min;Oh, Jin Sil;Myoung, Hoon;Lee, Jong Ho
    • Maxillofacial Plastic and Reconstructive Surgery
    • /
    • v.34 no.5
    • /
    • pp.332-336
    • /
    • 2012
  • Purpose: The third molar extraction is one of the mostly performed procedures in the department of oral and maxillofacial surgery. In most of dental clinic or hospital, the third molar extraction used to be frequently performed in an office-based surgery, and most patients did not have specific medical history with young ages. Medical history taking are dependent on the only way by asking to the patients about their individual conditions. Therefore, as the specialists of the oral and maxillofacial surgery in the field of dentistry, we suggest a new policy that the preoperative lab must be performed routinely before extraction of the third molar. Methods: This study is based on 1,096 patients who have been managed with third molar extractions, from March 2008 to September 2011 by a single surgeon. The preoperative lab, including complete blood count, coagulation panel, chemistry and serology, was performed before any surgical procedures. The results were informed to the patients regardless of their abnormalities, and any abnormalities related to the surgical procedures, such as platelet count and coagulation factors, were checked and corrected safely. Results: Through the preoperative blood test, systemic diseases that the patients had not recognized before, such as anemia, leukopenia, fatty liver and chronic renal disease, were identified. Patients with acute or chronic leukemia, Hepatitis B, and HIV positive, were also detected as a small number. Also, the possibilities of the cross-infection between dentists and patients or between patients and patients, and any other emergency situations can be prevented; as well as the public health condition can be improved, too. The patients were satisfied with low cost preventive blood test and high quality of medical services. Conclusion: Therefore, routine medical lab testing, including history taking are needed before an office-based minor surgery, such as third molar extractions, and these results were suggested as a new policy in the field of dentistry.