• Title/Summary/Keyword: Coagulation test

Search Result 210, Processing Time 0.033 seconds

General Pharmacology of LB20304a, a New Quinolone Antibiotic (새로운 퀴놀론계 항생제 LB20304a의 일반약리작용)

  • 김희진;오정인;이창호
    • Biomolecules & Therapeutics
    • /
    • v.4 no.2
    • /
    • pp.184-189
    • /
    • 1996
  • General pharmacological studies of LB20304a (a mesylate salt form of a new quinolone antibiotic LB20304 following oral administration of 300 mg/kg and 1000 mg/kg, almost maximum tolerance dose in mice and rat, respectively, were performed in terms of effects on general behaviour, central nervous system, gastrointestinal system, and blood coagulation system in mice and rats. With regards to general behaviour of mice, at oral dose of 300 mg/kg, LB20304a reduced muscle tone and locomotor activity. In terms of CNS, at oral treatment of 300 mg/kg, LB20304a showed some analgesic effects in mice, and oral dose of 1000 mg/kg caused drop in normal body temperature of rat, while it enhanced the pentylenetetrazole-induced clonic convulsion to tonic convulsion and/or death in mice at the doses of unto 300 mg/kg. In addition, LB20304a increased hexobarbital-induced sleeping time two and three times in mice at oral doses of 20 mg/kg and 300 mg/kg, respectively. Rota-rod and traction test in mice were not influenced by the dose of 300 mg/kg and 200 mg/kg, respectively. LB20304a reduced gastric secretion of rat at dose of 1000 mg/kg, and increased intestinal motility of mice at dose of 300 mg/kg. In rats, blood coagulation index, such as PT (prothrombin time) and aPTT (activated partial thromboplastin time) were not affected by the treatment of upto 1000 mg/kg of LB 20304a.

  • PDF

The Effects of Turbidity and pH on the Removal of Cryptosporidium and Giardia by Coagulation Process (원수 탁도와 pH 변화가 혼화응집침전 과정에서 원생동물과 탁질 제거에 미치는 영향)

  • Chung, Hyen-Mi;Park, Sang-Jung
    • Journal of Korean Society of Water and Wastewater
    • /
    • v.20 no.1
    • /
    • pp.71-78
    • /
    • 2006
  • The removal of protozoa in the coagulation process was evaluated under the different pH and turbidity using the jar test after the addition of polyaluminium chloride (PAC) as a coagulant. Two well-known protozoa of Cryptosporidium parvum and Giardia lamblia were tested at the same time with turbidity, the critical water quality parameter of the water treatment process. Both protozoa were removed about 1log (and up to 2log) at the optimum injection of PAC. The source water turbidity and pH affected the removal of protozoa and turbidity. At neutral and alkaline pH, 1.3-1.7log removal of protozoa for low turbid water with 5NTU, and 1.6-2.3log removal for high turbid water with 30NTU were achieved. However, at acidic pH, maximum 0.8-1.0log and 1.1-1.2log were removed for low and high turbid water, respectively, at the optimum PAC injection of 15mg/L. The relation of protozoa and turbidity removals were expressed as the 1st order equation (significantly positive relation) in the most of the tested conditions. In addition, the relation of protozoan removals with residual turbidity were also expressed the 1st order equation (significantly negative relation), although the significance of the equations were reduced at acidic pH. Therefore, residual turbidity could be a good index of efficient protozoan removal in the coagulation process, probably except at the low pH condition.

Improvement of Cooling Water Quality by Coagulation and Sedimentation in Steel Mill (응집침전에 의한 제철공장 냉각수질향상)

  • Jo, Kwan-Hyung;Woo, Dal-Sik;Hwang, Byung-Gi;Lee, Seon-Ju;Park, Duck-Weon
    • Journal of Environmental Health Sciences
    • /
    • v.35 no.5
    • /
    • pp.411-416
    • /
    • 2009
  • This study was initiated to improve the cooling water quality by chemical coagulation and sedimentation in steel mills. Due to the inefficient flocculation in the settling tanks of blast furnace cooling water systems, the solid particles in the cooling water overflow accumulate and clog the cooling system. To protect the cooling water system from such fouling, proper flocculants must be continuously used. Laboratory tests were performed for the indirect cooling water system of a plate mill. The batch test in the gas scrubbing cooling water system of a blast furnace showed that the proposed coagulant was more effective for the improvement of coagulation and sedimentation than the existing one. During the tests, cationic flocculants were more effective than use of only an anionic flocculant. The suggested combination of anionic and cationic flocculants can probably improve the turbidity removal efficiency of the cooling water. Proper control of the overflow rate by the designed residence time would help turbidity removal efficiency in the settling tank. In addition, the settling can be enhanced by adopting rapid and slow mixing alternatively. Scale problems in blast furnace cooling water system were reduced to some extent by efficient settling.

A Study on Coagulation and MF Membrane Process for the Reuse of Sewage Effluent (하수처리장 방류수의 응집 및 정밀여과 처리공정에 관한 연구)

  • Paik, Ke-Jin
    • Journal of environmental and Sanitary engineering
    • /
    • v.20 no.3 s.57
    • /
    • pp.36-43
    • /
    • 2005
  • Prior to the study of the sewage treatment methods, water quality for Gwangju sewage of fluent was investigated from January to December, 2004 for sewage water reuse. Monthly mean values of BOD, SS, turbidity, total phosphorus and color were 4.1 mg/L, 2.9 mg/L, 0.8 NTU, 1.3 mg/L, and 27 unit, respectively. Jar-test was performed to investigate the removal efficiency of pollutants under the coagulation conditions of fast mixing for 5 min, slow mixing for 15 min and precipitation for 1hr. Here, alum and polyaluminium chloride (PAC) were used as coagulants to reduce color, turbidity, total phosphorus (TP) and total organic carbon (TOC) in sewage effluents. The results showed that PAC gave better efficiency in removing turbidity and dissolved phosphorus than alum. It was also found from the relative molecular weight (RMW) distribution analysis that organic matter over 1,000 Dalton (Da) was easily removed by coagulation and subsequently MF treatment, while it was not effective for less than 500 Da. Based on tis result, Natural organic matter (NOM) with lower molecular weight (< 500 Da) may cause harmful disinfectant by-product (DBP) after chlorine treatment. Thus, activated carbon adsorption seems to be required for the complete removal of DBP in the hybrid system.

Characteristics of DOC Removal by Coagulation Process in the Water Treatment of Nakdong River (낙동강 수계에 대한 정수처리공정에서 응집공정의 DOC 제거 특성)

  • Hwang, Deok-Heung;Kim, Dong-Young
    • Journal of Korean Society of Water and Wastewater
    • /
    • v.13 no.2
    • /
    • pp.66-73
    • /
    • 1999
  • This study was carried out to derive the removal characteristics of target materials(DOC and turbidity) during the coagulation process after the injection of coagulants(PACl and FeCl3). Used apparatus were a jar test and a pilot plant. A great portion of DOC among the total removed DOC was achieved at the slow mixing process among the coagulation process. The ranges of removed DOC and optimum pH for each coagulant were 0.45~1.47mg/l and 6.0~6.5 by PACl, and 0.97~2.61mg/l. and 5.0~5.5 by FeCl3, respectively. Both of coagulants showed little increase of DOC removal above coagulant dosage 20mg/l Molecular weight distribution(MWD) of removed DOC was measured by get filtration(GF) technique. The MWD variation by gel filtrationin(GF) for removed DOC in the coagulation process were as follows; for raw water, the percentages of each MWD for total area were < MW 6,500 25.5%, MW 6,500~66,000 67.1%, and > MW 66,000 7.4%. For the same coagulant dosage(12mg/l), the percentages of each MWD for total area by PACl were < MW 6,500 20.5%, MW 6,500~66,000 48.7%, and > MW 66,000 9.1%, and those of FeCl3 were MW 66,000 18.2%. For each coagulant, the removal percentage of MW 6,500~66,000 occurred a little, but at a part of

  • PDF

Preservation of Coagulation Efficiency of Moringa oleifera, a Natural Coagulant

  • Katayon, S.;Ng, S.C.;Johari, M.M.N.Megat;Ghani, L.A.Abdul
    • Biotechnology and Bioprocess Engineering:BBE
    • /
    • v.11 no.6
    • /
    • pp.489-495
    • /
    • 2006
  • In recent years, there has been an interest to use Moringa oleifera as the natural coagulant due to cost, associated health and environmental concerns of synthetic organic polymers and inorganic chemicals. However, it is known that M. oleifera as the natural coagulant is highly biodegradable and has a very short shelf life. This research was carried out to investigate the effects of storage temperature, packaging methods, and freeze-drying on the preservation of M. oleifera seeds powders. Non freeze-dried M. oleifera was prepared into different packaging namely open container, closed container and vacuum packing, whilst, freeze-dried M. oleifera was stored in closed container and vacuum packing. Each of the packaging was stored at room temperature ($30\;to\;32^{\circ}C$) and refrigerator ($4^{\circ}C$). The turbidity removal efficiencies of stored M. oleifera were examined using jar test at monthly interval for 12 months. The results indicated that non freeze-dried M. oleifera kept in the refrigerator ($4^{\circ}C$) would preserve its coagulation efficiency. In addition, closed container and vacuum packing were found to be more appropriate for the preservation of non freeze-dried M. oleifera, compared to open container. Freeze-dried M. oleifera retained its high coagulation efficiency regardless the storage temperature and packaging method for up to 11 months. Besides, higher increment in zeta potential values for water coagulated with freeze-dried M. oleifera indicated the higher frequency of charge neutralization and better coagulation efficiency of freeze-dried M. oleifera, compared to non freeze-dried seeds. As a coagulant, M. oleifera did not affect the pH of the water after treatment.

Effect of 4-hexylresorcinol on Blood Coagulation and Healing of Injured Vessel in a Rat Model

  • Park, Yong-Tae;Park, Si-Yeok;Kim, Min-Keun;Kim, Seong-Gon;Park, Young-Wook;Kwon, Kwang-Jun
    • Maxillofacial Plastic and Reconstructive Surgery
    • /
    • v.35 no.5
    • /
    • pp.284-293
    • /
    • 2013
  • Purpose: For reconstruction of craniomaxillofacial defects caused by tumor, trauma, infection etc, free flap transplantation with microvascular surgery is a very useful method. Thrombus formation at the anastomosis site is the major cause of graft failure. 4-Hexylresorcinol (4-HR) is generally known as an antiseptic and antiparasitic agent. This study was conducted in order to evaluate the effect of 4-HR on blood coagulation in vitro. In addition, we investigated thrombus formation and endothelial repair of an injured vessel in an animal model. Methods: In the in vitro experiment, we compared blood coagulation time between the 4-HR treated group and normal blood. Thirty rats were used for in vivo animal experiments. After exposure of the right femoral vein, a micro vessel clamp was placed and the femoral vein was intentionally cut. Microvascular anastomosis was performed on all rats using 10-0 nylon under microscopy. The animals were divided into two groups. In the experimental group (n=15), 4-HR (250 mg/kg) mixed with olive oil (10 mL/kg) was administered per os daily. Animals in the control group (n=15) were given olive oil only. The animals were sacrificed at three days, seven days, and fourteen days after surgery and rat femoral vein samples were taken. Vascular patency and thrombus formation were investigated just before sacrifice. Histologic analysis was performed under a microscope. Results: Results of an in vitro blood coagulation test showed that coagulation time was delayed in the 4-HR treated group. The results obtained from an in vivo 4-HR administered rat model showed that the patency of all experimental groups was better at thirty minutes, seven days, and fourteen days after microvascular anastomosis than that of the control group at seven and fourteen days after anastomosis, and the amount of thrombus in the experimental groups was much less than that of the control group. Endothelial repair was observed in the histologic analysis. Conclusion: Findings of this study demonstrated that blood coagulation was delayed in the vitro 4-HR treated group. In addition, good vascular patency, anti-thrombotic effect, and repair of venous endothelial cells were observed in the vivo 4-HR administered rat group.

Application of coagulation pretreatment for enhancing the performance of ceramic membrane filtration (세라믹 막여과의 성능향상을 위한 응집 전처리의 적용)

  • Kang, Joon-Seok;Song, Jiyoung;Park, Seogyeong;Jeong, Ahyoung;Lee, Jeong-Jun;Seo, Inseok;Chae, Seonha;Kim, Seongsu;Kim, Han-Seung
    • Journal of Korean Society of Water and Wastewater
    • /
    • v.31 no.6
    • /
    • pp.501-510
    • /
    • 2017
  • In this study, it is estimated that ceramic membrane process which can operate stably in harsh conditions replacing existing organic membrane connected with coagulation, sedimentation etc.. Jar-test was conducted by using artificial raw water containing kaolin and humic acid. It was observed that coagulant (A-PAC, 10.6%) 4mg/l is the optimal dose. As a results of evaluation of membrane single filtration process (A), coagulation-membrane filtration process (B) and coagulation-sedimentation-membrane filtration process (C), TMP variation is stable regardless of in Flux $2m^3/m^2{\cdot}day$. But in Flux $5m^3/m^2{\cdot}day$, it show change of 1-89.3 kpa by process. TMP of process (B) and (C) is increased 11.8, 0.6 kpa each. But, the (A) showed the greatest change of TMP. When evaluate (A) and (C) in Flux $10m^3/m^2{\cdot}day$, TMP of (A) stopped operation being exceeded 120 kpa in 20 minutes. On the other hand, TMP of (C) is increased only 3 kpa in 120 minutes. Through this, membrane filtration process can be operated stably by using the linkage between the pretreatment process and the ceramic membrane filtration process. Turbidity of treated water remained under 0.1 NTU regardless of flux condition and DOC and $UV_{254}$ showed a removal rate of 65-85%, 95% more each at process connected with pretreatment. Physical cleaning was carried out using water and air of 500kpa to show the recovery of pollutants formed on membrane surface by filtration. In (A) process, TMP has increased rapidly and decreased the recovery by physical cleaning as the flux rises. This means that contamination on membrane surface is irreversible fouling difficult to recover by using physical cleaning. Process (B) and (C) are observed high recovery rate of 60% more in high flux and especially recovery rate of process (B) is the highest at 95.8%. This can be judged that the coagulation flocs in the raw water formed cake layer with irreversible fouling and are favorable to physical cleaning. As a result of estimation, observe that ceramic membrane filtration connected with pretreatment improves efficiency of filtration and recovery rate of physical cleaning. And ceramic membrane which is possible to operate in the higher flux than organic membrane can be reduce the area of water purification facilities and secure a stable quantity of water by connecting the ceramic membrane with pretreatment process.

Optimization of Ultrafiltration Process using $MIEX^{(R)}$+Coagulation Process ($MIEX^{(R)}$+응집공정을 이용한 한외여과 공정의 최적화 : 다양한 전처리 공정의 적용에 따른 막 오염 현상 규명)

  • Son, Hee-Jong;Hwang, Young-Do;Roh, Jae-Soon;Jung, Chul-Woo;Kang, Lim-Seok
    • Journal of Korean Society of Environmental Engineers
    • /
    • v.27 no.7
    • /
    • pp.753-761
    • /
    • 2005
  • In this study, pretreatment of organic matters with $MIEX^{(R)}$ was evaluated using bench-scale experimental procedures on four organic matters to determine its effect on subsequent UF membrane filtration. For comparison, coagulation process was also used as a pretreatment of UF membrane filtration. Moreover, the membrane fouling potential was identified using different fractions and molecular weights of organic matters. From the removal property of MW organic matters by coagulation process for the sample water NOM and AOM, the removal efficiency of high MW organic matters were much higher than those of low MW organic matters. It was shown that the removal efficiency of high MW organic matter more than 10 kDa was lower than that of low MW organic matter for $MIEX^{(R)}$ process. For the change of permeate flux by the pretreatment process, $MIEX^{(R)}$+UF process showed high removal efficiency of organic matter as compared with coagulation-UF processes, but high reduction rate of permeate flux was presented through the reduction of removal efficiency of high MW organic matter. From sequential filtration test results in order to examine the effect of MW of organic matter on membrane fouling, it was found that the membrane foulant was occurred by high MW organic matter, and the DOC of organic matter less than 0.5 mg/L was working as the membrane foulant. In the case of sample water composed of low MW organic matter less than 10 kDa, since the low MW organic matter less than 10 kDa has high removal efficiency by $MIEX^{(R)}$, low reduction rate of permeate flux is obtained as compared with coagulation-UF processes. In summary, it is required to conduct the research on physical/chemical characteristic of original water before pretreatment process of membrane process is selected, and a pertinent pre-treatment process should be employed based on the physical/chemical characteristic of original water.

Evaluation of Soil Flushing Column Test for Oil-contaminated Soil Treatment (유류오염토양 처리를 위한 컬럼식 토양세정기술 평가)

  • Kang, Hui-Cheon;Han, Byeong-Gi;Kim, Joung-Dae;Seo, Seung-Won;Shin, Chul-Ho;Park, Joon-Seok
    • Clean Technology
    • /
    • v.23 no.3
    • /
    • pp.302-307
    • /
    • 2017
  • This study was conducted to evaluate the feasibility of in situ soil flushing for TPH-contaminated soil remediation with column test. The soil texture of the soil was sand and the initial TPH concentration was $9,369mg\; kg^{-1}$. 0.1% Tween-80 was selected as surfactant solution. And the acrylic and the glass syringe columns were used as reactors. In the acrylic column test, 35% of the initial TPH was removed in 1 PV of flushing and approximately 40% in 5 PV and finally 7 PV showed about 60%. The glass column test showed 3 ~ 12% higher removal efficiency than that of acrylic test until 5 PV of flushing. However, there was no difference in TPH removal efficiency when 7 PV of surfactant was finally flushed. Both of alum only and alum+polymer mixed surfactants showed also the best coagulation efficiency in $150mg\;L^{-1}$ of concentraion. When Tween 80 was newly dissolved in 0.1% to the recovered solution after the coagulation treatment, the removal efficiency was increased from 32.0% to 41.0% in comparison to the new 0.1% Tween 80 solution without reuse by coagulation treatment.