• Title/Summary/Keyword: Coagulation test

Search Result 210, Processing Time 0.02 seconds

Coagulation Control of High Turbid Water Samples Using a Streaming Current Control System (유동흐름 전류계를 이용한 정수장 고탁도 유입수 응집 제어 방법에 대한 연구)

  • Nam, Seung-Woo;Jo, Byung-Il;Kim, Won-Kyong;Zoh, Kyung-Duk
    • Journal of Environmental Health Sciences
    • /
    • v.38 no.2
    • /
    • pp.128-135
    • /
    • 2012
  • Objectives: This study was aimed at determining the optimum coagulation dosage in a high turbid kaolin water sample using streaming current detection (SCD) as an alternative to the jar test. Methods: SCD is able to optimize coagulant dosing by titration of negatively charged particles. Kaolin particles were used to mimic highly turbid water ranging from 50 to 600 NTU, and polyaluminum chloride (PAC, 17%) was applied as a titrant and coagulant. The coagulation consisted of rapid stirring (5 min at 140 rpm), reduced stirring (20 min at 70 rpm), and settling (60 min). To confirm the coagulation effect, a jar test was also compared with the SCD titration results. Results: SCD titration of kaolin water samples showed that the dose of PAC increased as the pH rose. However, supernatant turbidity less than 1 NTU after coagulation was not achieved for high turbid water by SCD titration. Instead, a conversion factor was used to calculate the optimum PAC dosage for high turbid water by correlating a jar test result with that from an SCD titration. Using this approach, we were able to successfully achieve less than 1 NTU in treated water. Conclusions: For high turbid water influent in a water treatment plant, particularly during summer, the application of SCD control by applying a conversion factor can be more useful than a jar test due to the rapid calculation of coagulation dosage. Also, the interpolation of converted PAC dose could successfully achieve turbidity in the treated water of less than 1 NTU. This result indicates that an SCD system can be effectively used in a water treatment plant even for high turbid water during the rainy season.

Viscoelastic Coagulation Test Guided Therapy for a Strategy to Reduce Transfusions (수혈 감소 전략을 위한 점탄성 응고 검사법의 유용성)

  • Park, Sun Young
    • The Korean Journal of Blood Transfusion
    • /
    • v.29 no.3
    • /
    • pp.240-252
    • /
    • 2018
  • Viscoelastic coagulation tests provide simultaneous measurements of multiple aspects of whole-blood coagulation, including interactions between the plasma components and cellular components of the coagulation cascade. This can be carried out immediately using a point of care technique. Viscoelastic tests could predict the patient's outcome, including mortality, and detect coagulopathy more sensitively, resulted in reduced blood loss. The transfusion strategy based on the viscoelastic parameters rather than a conventional coagulation test has been shown to reduce the transfusion requirements. Although there are concerns about the reliability and accuracy of this method, viscoelastic tests, including ROTEM, would be a useful method to guide patient blood management strategies.

CONTROL OF DIATOM BY PREOXIDATION AND COAGULATION IN WATER TREATMENT

  • Seo, Jeong-Mi;Kong, Dong-Soo;Ahn, Seoung-Koo;Kim, Hyun-Ook
    • Environmental Engineering Research
    • /
    • v.11 no.1
    • /
    • pp.45-53
    • /
    • 2006
  • Conventional coagulation is still the main treatment process for algae removal in water treatment. The coagulation efficiency can be significantly improved by the preoxidation of algae-containing water. Jar test was conducted to determine the optimal condition for the removal of diatoms, especially Cyclotella sp. by preoxidation and the subsequent coagulation. The effects of various concentration of PAC (Polyaluminum chloride) on coagulation with and without preoxidation using chlorine or potassium permanganate at different pHs (7.7 and 9.0) were evaluated. At pH 7.7, preoxidation with 2ppm $Cl_2$ followed by coagulation with 7.5 ppm PAC coagulant could reduce Cyclotella sp. concentration by 86%. At pH 9.0, preoxidation with 1 mg $KMnO_4/L$ followed by coagulation with 12.5 ppm PAC coagulant reduced Cyclotella sp. concentration by 85%. Non-linear regression was applied to determine the optimal condition. At pH 7.7 and 9.0, R was over 0.9, respectively. The pH of algal blooming water is over 9.0. Algae (diatom; Cyelotella sp.) can be controlled in the following ways: preoxidation with 1 mg $KMnO_4/L$ followed by coagulation with 12.5 ppm PAC coagulant can remove 80% algae from water. If water pH is adjusted to 7.7, it was expected that less amount of coagulant (7.5 or 10 mg PAC /L) after preoxidation ($Cl_2$ 2 ppm or $KMnO_4$ 0.33, 1 ppm) would be needed to achieve similar level of algae removal. The oxidation with 0.33ppm $KMnO_4$ followed by coagulation with 7.5 ppm PAC coagulant was preferable due to cost-effectiveness of treatment condition and color problem after treatment.

Effects of Citrate-capped Silver Nanoparticles on the Blood Coagulation and Platelet Aggregation in Rats (랫드의 혈액응고 및 혈소판 응집에 미치는 은나노 입자의 영향)

  • Lee, Yeonjin;Park, Kwangsik
    • YAKHAK HOEJI
    • /
    • v.56 no.6
    • /
    • pp.382-389
    • /
    • 2012
  • Effects of citrate-capped silver nanoparticles (AgNPs) on the blood coagulation and platelet aggregation were investigated using whole blood, platelet rich plasma (PRP) and washed platelet obtained from SD male rats. To confirm the stability of AgNPs in the test, size distribution of the nanoparticles was measured in the vehicles including distilled water, serum, and platelet buffers. The average size of AgNPs was 20 nm in the vehicles, which means that the stability was maintained during the whole experimental period. When blood coagulation was monitored by using whole blood impedance aggregometer, coagulation was not observed at the concentration of 1, 10 and 50 ppm. Platelets in plasma or in buffer were not aggregated by AgNPs at the concentration of 1, 2 and 4 ppm, respectively. The test concentration of AgNPs could not be increased because the dark color of the nanoparticles impeded the transmission of light, which is an indicator of aggregation. Although the blood or platelets were pre-activated by collagen, thrombin, or ADP with sub-threshold level, aggregation was not observed at the test concentration. Microscopic observation also supported the result obtained by the aggregometer.

Application of Ultra Rapid Coagulation for Securing Water Resource II: Study of organic, metals, and nutrients removal (수자원 확보를 위한 URC공법의 적용 I: 유기물, 중금속, 영양염의 제거특성에 관한 연구)

  • Park, Se Jin;Yoon, Tai Il;Kim, Jae Hyung;Cho, Kyung Chul
    • Clean Technology
    • /
    • v.6 no.1
    • /
    • pp.27-38
    • /
    • 2000
  • A physicochemical process called Ultra Rapid Coagulation(URC) can dramatically remove organics, metals, and phosphates in wastewater by adding weighted coagulation additive(WCA) and recycling sludge into the coagulation basin to increase the growth rate and adsorption ability of floc. Also this process can improve floc settling rate than conventional coagulation process and reduce the pollutants loaded into the receiving water for securing water source. It was evaluated that WCA and sludge added have effects on the removal efficiency and estimated the possibilities of reusing the effluent from this process.

  • PDF

Characterization of Coagulation on Synthetic Polymerization Al(III) Inorganic Coagulants for Water Treatment (상수처리용 합성 무기고분자 Al(III)계 응집제의 응집특성)

  • Han Seung-Woo;Jung Chul-Woo;Kang Lim-Seok
    • Journal of Environmental Science International
    • /
    • v.8 no.6
    • /
    • pp.717-724
    • /
    • 1999
  • This experiment was performed on three parts with prepared coagulants. (1) The characterization of coagulation for PACI coagulants. (2) Comparison of the characterization of coagulation with PAS and PACI coagulants. And (3) Comparison of the characterization of coagulation for the addition of calcium with PACI. Coagulation experiments were conducted with several dosages and pH for each coagulants. For the characterization of coagulation with PACI coagulants, coagulation of Nakdong river waters with three PACls (r=2.0, 2.2, 2.35) showed that the effectiveness of the three coagulants can be considered as r=2.2 > 2.0 > 2.35 which are also the order of higher polymeric aluminum contents. For the comparison of the characterization of coagulation for PAS and PACI coagulants, PAS (r=0.75) coagulants was more effective than other coagulant for the removal of organic matters by sweep floc mechanism with $A;(OH)_{3(S)}$. For comparison of the characterization of coagulation for the addition of calcium with PACI, the presence of divalent cation like $Ca^{2+}$ was supposed to influence the complex formation of organic anions. From the result of test on coagulation at various pH ranges, the PACI was least affected by the coagulation pH, and the addition of calcium to PACI was very effective for the removal of turbidity and organic materials over broader pH range (pH 4-9).

  • PDF

A Study on Membrane Fouling by Flux and Linear Velocity in Coagulation/Ultrafiltration Membrane System (응집·한외여과 조합공정에서 플럭스와 선속도가 막오염에 미치는 영향에 관한 연구)

  • Moon, Seong-Yong;Lee, Sang-Hyup;Kim, Seung-Hyun;Yoon, Cho-Hee
    • Journal of Korean Society of Water and Wastewater
    • /
    • v.19 no.4
    • /
    • pp.429-436
    • /
    • 2005
  • A coagulation/ultrafiltration membrane hybrid system was operated to treat river water with capacity of $0.06m^3/d$. The impact on membrane fouling by flux and linear velocity was investigated. It is known that pressure increase is proportional to flux increase. However, pressure increase was much faster than theoretical value in the pilot plant test. So it was suggested that flux was on important factor in ultrafiltration of continuous operation. Membrane fouling was decreased when linear velocity was increased. This phenomenon was found more obviously without coagulation. With the combination of coagulation and sedimentation, membrane fouling was not reduced conspicuously. Big particles formed during coagulation and sedimentation were destroyed by feed and circulation pumping, which resulted in little effect on membrane fouling reduction. The degree of destruction was similar at various linear velocities. In this study, the hollow fiber membrane was used and the system was operated in pressure type module. In case of the system used in this study, membrane fouling has been affected lightly by linear velocity variation when coagulation pretreatment was applied.

Economical Evaluation Based on Method of Coagulation with GAC Adsorber Operation (활성탄 흡착지의 운영시 응집 방법에 따른 경제성 평가)

  • Hong, Seongho;Sung, Dae-Hyun
    • Journal of Korean Society of Water and Wastewater
    • /
    • v.19 no.4
    • /
    • pp.473-479
    • /
    • 2005
  • Applying enhanced coagulation is not uncommon not only to improve water quality but also to obtain economical advantages in water treatment. In this study, the economical evaluation was investigated with considering dosage of coagulant, produced sludges and usage of activated carbon with two different water sources. To simulate the granular activated carbon(GAC) adsorber mini-column test was adapted. Even if there were some variation according to the source waters, the life time of GAC was extended 60 to 110days with adding 2.5 to 3 times of coagulant in enhanced coagulation. With assumption of changing GAC adsorber at 50% of breakthrough the total treatment cost can be reduced to range from 25% to 44% with adapting the enhanced coagulation. The obtained value can not be generalized because the value can be varied by water quality and cost of the GAC or coagulant. However, the evaluation can be basis starting point to find optimum operation methods for the drinking water treatment which has plan to adapt GAC adsorber.

Screening Test of Titanium Dioxide Nanoparticles on Blood Coagulation and Platelet Aggregation (티타늄 금속나노입자의 혈액응고작용 검색)

  • Park, Kwang-Sik
    • Environmental Analysis Health and Toxicology
    • /
    • v.23 no.4
    • /
    • pp.285-290
    • /
    • 2008
  • Effects of titanium dioxide nanoparticles on blood coagulation and platelet aggregation were investigated using diluted whole blood and platelet rich plasma (PRP) solution prepared from human and rat blood, respectively. Blood coagulation was monitored by using a whole blood impedance aggregometer and titanium dioxide nanoparticle (10, 20, and 40 ppm) did not show any effect on the coagulation both in human and in rat blood. When platelet aggregation was measured by turbidometric method after addition of titanium dioxide nanoparticles to PRP solution with final concentrations of 1, 5 and 10 ppm. no aggregation was observed.

Evaluation of Pilot scale Coagulation system Design for CSOs treatment (CSOs 처리를 위한 실증규모 응집침전시스템의 설계평가)

  • Lee, Seung-Chul;Ha, Sung-Ryong
    • Journal of Wetlands Research
    • /
    • v.15 no.1
    • /
    • pp.1-8
    • /
    • 2013
  • A pilot scale coagulation system, which has a function of physicochemical treatment, was developed to treat Combined sewer overflows(CSOs). This coagulation system requires evaluation of optimum design factors whether it has reflected those of lab scale system, moreover, the pilot scale system can be evaluated differently according to the characteristics of influent CSOs even though it has reflected lab scale's design factors. We conducted an experiment using lab scale system that could treat $1m^3$ of CSOs in a day, and also pilot-scale system with $100m^3/day$ CSOs flowed into the Cheongju sewage treatment plant. Therefore the aim of this study is to evaluate a hydraulic similarity between the design factors of pilot scale and those of lab scale coagulation system, and to evaluate feasibility of the coagulation system for the CSOs treatment with optimum operation conditions. From the result of pilot-test, we drew the optimum operation factors of in line mixer and flocculator having similarities with those of lab scale system as well as the optimum coagulant dose. Finally we confirmed that the coagulation system has feasibility to treat the CSOs with high removal efficiency.