• Title/Summary/Keyword: Coagulation reaction

Search Result 120, Processing Time 0.032 seconds

The growth of zinc oxide particles by coagulation in aerosol reactor (에어로졸 반응기에서 산화아연 입자의 응집 성장)

  • Lee, Jong Ho;Song, Shin Ae;Park, Seung Bin
    • Particle and aerosol research
    • /
    • v.4 no.2
    • /
    • pp.69-75
    • /
    • 2008
  • Nanosize ZnO particles were prepared by oxidation of zinc vapor and the particle growth was modeled by a coagulation model by assuming that the characteristic time for reaction was much shorter than coagulation time and residence time (${\tau}_{reaction}{\ll}{\tau}_{coagulation}{\ll}{\tau}_{residence}$). Experimental measurement of zinc oxide particles diameter was consistent with the predicted result from the coagulation model. For practical purpose of predicting zinc oxide size in areosol reactor, the constant kernel solution is concluded to be sufficient, Uniqueness of nano-scale property of zinc oxide was confirmed by the higher photocatalytic activity of zinc oxide than nanosize titania particles.

  • PDF

Evaluation of effective process for oxidation and coagulation by ferrous ion and hydrogen peroxide

  • Moon, H.J.;Kim, Y.M.;Lee, S.H.
    • Proceedings of the Korean Environmental Sciences Society Conference
    • /
    • 2003.11b
    • /
    • pp.319-321
    • /
    • 2003
  • This research was carried out to evaluate the removal efficiencies of CODcr and colour for the dyeing wastewater by ferrous solution in Fenton process. The results showed that COD was mainly removed by Fenton coagulation, where the ferric ions are formed in the initial step of Fenton reaction. On the other hand colour was removed by Fenton oxidation rather than Fenton coagulation. The removal mechanism of CODcr and colour was mainly coagulation by ferrous ion, ferric ion and Fenton oxidation. The removal efficiencies were dependent on the ferric ion amount at the beginning of the reaction. However the final removal efficiency of COD and colour was in the order of Fenton oxidation, ferric ion coagulation and ferrous ion coagulation. The reason of the highest removal efficiency by Fenton oxidation can be explained by the chain reactions with ferrous solution, ferric ion and hydrogen peroxide.

  • PDF

Flocculation of Red Tide Organisms in Sea Water by Using an Ignited Oyster Shell Powder and Loess Combination (소성굴패각분말과 황토의 동시 사용에 의한 적조생물의 응집)

  • KIM Sung-Jae
    • Korean Journal of Fisheries and Aquatic Sciences
    • /
    • v.36 no.6
    • /
    • pp.716-722
    • /
    • 2003
  • This study determined the optimum dosage for coagulation reactions of red tide organisms (RTO) using a combination of ignited oyster shell powder (10sp) and loess and examined the electrokinetic and rheological characteristics of their flocs. Two kinds of RTO, Cylindrotheca closterium and Skeletonema costatum, were sampled in Masan Bay and cultured in the laboratory. Coagulation experiments were conducted using various concentrations of IOSP, loess, IOSP+1oess, RTO, and a jar tester RTO cell numbers were counted for both the supernatant and RTO culture solution. The removal rates increased rapidly with increasing IOSP concentrations up to 50 mg/L and loess concentrations up to 800 mg/L. A removal rate of $100\%$ was reached at 400 mg/L of IOSP and 6,400 mg/L of loess. The highest increment $(16.7\%)$ of the rates of coagulation reaction occurred using both IOSP and loess (50+200 mg/L) in comparison with IOSP alone. The rate of coagulation reaction using both IOSP and loess (50+200 mg/L), $90.6\%,$ was similar to employing either IOSP of 150 mg/L or loess of 3,200 mg/L. All of the coagulation liquids for RTO, IOSP (200 mg/L), loess (200 ma/L), and IOSP+1oess (200+200 mg/L) revealed non-Newtonian fluid properties and therefore their shear rate vs. shear stress curves were non-linear. The coagulation liquids revealed elastic body properties at a lower shear rate increasing in the following order: RTO, IOSP (200 mg/L), loess (200 mg/L), and IOSP+1oess (200+200 mg/L. IOSP+1oess (200+200 mg/L) especially demonstrated plastic flow properties at a lower shear rate.

Evaluation of Effective Process Operation for the Texitile Dyeing Wastewater by Ferrous Solution and Hydrogen Peroxide

  • Lee, Sang Ho;Moon, Hey Jin
    • Journal of Environmental Science International
    • /
    • v.13 no.11
    • /
    • pp.987-991
    • /
    • 2004
  • The purpose of this research is to evaluate the removal efficiencies of COD$\_$Cr/ and color for the dyeing wastewater by the different dosages of ferrous solution and H$_2$O$_2$ in Fenton process. In the case of H$_2$O$_2$ divided dosage for the Fenton's reagent 7:3 of H$_2$O$_2$ was more effective than 3:7 to remove COD$\_$Cr/ and color. The results showed that COD$\_$Cr/ was mainly removed by Fenton coagulation, where the ferric ions are formed in the initial step of Fenton reaction. On the other hand color was removed by Fenton oxidation rather than Fenton coagulation. The removal mechanism of COD$\_$Cr/ and color was mainly coagulation by ferrous ion, ferric ion and Fenton oxidation. The removal efficiencies were dependent on the ferric ion amount at the beginning of the reaction. However, the final removal efficiency of COD$\_$Cr/ and color was in the order of Fenton oxidation, ferric ion coagulation and ferrous ion coagulation. The reason of the highest removal efficiency by Fenton oxidation can be explained by the chain reactions with ferrous solution, ferric ion and hydrogen peroxide.

A Study on the Reduction of Color in Dye Wastewaters by Physico-chemical Processes (물리, 화학적 처리방법에 의한 염색폐수의 색도제거에 관한 연구)

  • 이준석;김민호;김영규
    • Journal of Environmental Health Sciences
    • /
    • v.19 no.3
    • /
    • pp.29-35
    • /
    • 1993
  • This study was performed to obtain optimal conditions for reduction of color in dye wastewaters using coagulation-sedimentation processes with redox reactions. The reduction of color as well as organic matters variation was observed after coagulation-sedimentation processes using FeSO$_4$ $\cdot$ 7H$_2$O and NaOCl. Coagulation-redox reaction was done with the dose of Coagulant and oxidant at various pH values. Redox reaction was done through jar-mixing and aeration. The results of study were as follows: 1. In the coagulation-sedimentation processes using FeSO$_4$ $\cdot$ 7H$_2$O, color reduction was heigher at pH 3. With variance of dosage of FeSO$_4$ $\cdot$ 7H$_2$O, color reduction was higher at 250 mg/l. When coagulation-sedimentation using FeSO$_4$ $\cdot$ 7H$_2$O 250 mg/l was added at pH 3, the reduction of color, COD$_{Mn}$, and COD$_{Cr}$ showed 47.6%, 21.3% and 22.1%, respectively. 2. When NaOCI was added at level of 100 ppm in raw wastewater at pH 3, the reduction of color, COD$_{Mn}$, and COD$_{Cr}$ showed 30.2%, 5.5% and 6.2%, respectively. 3. After coagulation-sedimentation processes by addition of FeSO$_4$ $\cdot$ 7H$_2$O, when NaOCl was added at level of 250 mg/l in supernant, color reduction was 47.8% in aeration and 37.5% in jar-mixing. 4. Color reduction by aeration was higher than that by jar-mixing.

  • PDF

Synthesis of \$alpha-Al_2O_3/SiO_2$ Composite Powders for Reaction-Sintered Mullite and its Properties (반응소결 물라이트를 위한 \$alpha-Al_2O_3/SiO_2$ 복합분말의 합성 및 그 특성)

  • Kim, Hye-Soo;Lee, Jong-Kook;Kim, Hwan
    • Journal of the Korean Ceramic Society
    • /
    • v.32 no.8
    • /
    • pp.909-914
    • /
    • 1995
  • From alumina powder and TEOS, $\alpha$-Al2O3/SiO2 composite powder for reaction-sintered mullite was synthesized by heterogeneous coagulation and surface coating, and investigated the mullitization reaction and sintering behavor of these powders. In $\alpha$-Al2O3/SiO2 composite powder prepared by heterogeneous coagulation, each alumina particles were surrounded by silica particles of 50~60 nm in size. And the alumina particles in composite powder prepared by surface coating were coated by uniform silica layer with thickness of 50 nm. In both methods, mullitization reaction was completed at 1$650^{\circ}C$ for 3h, and specimen sintered above 145$0^{\circ}C$ was about 95% fo the theoretical relative density. Mullite grains formed from the reaction with composite powders showed spherical shape with a size of 1~2${\mu}{\textrm}{m}$.

  • PDF

Astudy on Treatment of Livestock Wastewater using Coagulation and Fenton Oxidation Process (응집 및 fenton 산화공정을 연계한 축산폐수처리에 관한 연구)

  • Cho, Chang-Woo;Ryou, Jae-Woong;Chung, Paul-Gene
    • Journal of Korean Society on Water Environment
    • /
    • v.20 no.6
    • /
    • pp.610-614
    • /
    • 2004
  • The objective of this study was to remove organics and color in livestock wastewater using coagulation and Fenton oxidation process. After coagulation process as $1^{st}$ treatment, organics in $1^{st}$ treatment water were removed by using OH radical produced in Fenton oxidation process. Removal efficiencies of $COD_{Mn}$ and color were 87.2% and 95.7% separately. At that time, the ratio of $Fe^{2+}/H_2O_2$ was 0.8~1.0, and range of reaction pH was effective at the pH of 3.5~3.8. The Reaction time of 120min more than 60min or 90min was sufficient in Fenton process. Removal efficiency of organics was higher two- or multi-stage treatment than one-stage treatment.

The Study of Advanced Treatment of Sewage Wastewater by the Electro Coagulation and Oxidation System (전기응집산화를 이용한 하수처리장의 고도처리방안 연구)

  • Lim, Jin-Hwan
    • Journal of the Korean Society for Environmental Technology
    • /
    • v.19 no.6
    • /
    • pp.556-562
    • /
    • 2018
  • Due to the enforcement of effluent water regulation the advance sewage treatment system is needed to retrofit and remodelling. In this case the most important issue is the effluent concentrations of TP and there are a lot of system to reduce its concentration. But biological treatment processes have many restrictions to enhance the removal efficiency of TP. In this study the efficient ECO operating condition to improve and retrofit biological sewage wastewater treatment system is as follow; 1) The treatment efficiency of BOD, TN and TP at the current density of $15mA/cm^2$ was higher than the treatment efficiency at $5mA/cm^2$ in the electrodes arranged with Al-SUS(Stainless Steel) regardless of the reaction time, The TP concentration was 0.1 mg/L or less. Especially, when the reaction time was maintained at 10 min, the TP concentration was 0.06 mg/L or less irrespective of the current density. 2) The change of TP concentration is not influenced by the change of current density and rather the concentration of treated water changes according to the reaction time. In the case of electro coagulation reaction, a few seconds to several minutes are required. However, the reaction time of electro coagulation and oxidation was studied to be more than 10 minutes. 3) As a result, it has been studied that the economical current density of the electro coagulation oxidation process for TN and TP treatment of domestic wastewater is $15mA/cm^2$ or less and the reaction time is 10 minutes.

Enhanced total phosphorus removal using a novel membrane bioreactor by sequentially alternating the inflow and by applying a two-stage coagulation control based on pre-coagulation (유입흐름 변경 및 전응집 기반 이단응집 제어 적용 MBR을 통한 총인처리 개선 연구)

  • Cha, Jaehwan;Shin, Kyung-Suk;Park, Seung-Kook;Shin, Jung-Hun;Kim, Byung-Goon
    • Journal of Korean Society of Water and Wastewater
    • /
    • v.31 no.1
    • /
    • pp.103-114
    • /
    • 2017
  • A membrane bioreactor by sequentially alternating the inflow and by applying a two-stage coagulation control based on pre-coagulation was evaluated in terms of phosphorus removal efficiency and cost-savings. The MBR consisted of two identical alternative reaction tanks, followed by aerobic, anoxic and membrane tanks, where the wastewater and the internal return sludge alternatively flowed into each alternative reaction tank at every 2 hours. In the batch-operated alternative reaction tank, the initial concentration of nitrate rapidly decreased from 2.3 to 0.4 mg/L for only 20 minutes after stopping the inflow, followed by substantial release of phosphorus up to 4 mg/L under anaerobic condition. Jar test showed that the minimum alum doses to reduce the initial $PO_4$-P below 0.2 mg/L were 2 and 9 mol-Al/mol-P in the wastewater and the activated sludge from the membrane tank, respectively. It implies that a pre-coagulation in influent is more cost-efficient for phosphorus removal than the coagulation in the bioreactor. On the result of NUR test, there were little difference in terms of denitrification rate and contents of readily biodegradable COD between raw wastewater and pre-coagulated wastewater. When adding alum into the aerobic tank, alum doses above 26 mg/L as $Al_2O_3$ caused inhibitory effects on ammonia oxidation. Using the two-stage coagulation control based on pre-coagulation, the P concentration in the MBR effluent was kept below 0.2 mg/L with the alum of 2.7 mg/L as $Al_2O_3$, which was much lower than 5.1~7.4 mg/L as $Al_2O_3$ required for typical wastewater treatment plants. During the long-term operation of MBR, there was no change of the TMP increase rate before and after alum addition.

The Removal of Heavy Metals and Anion in Mining Wastewater by Silica Matrix Coagulation (Silica계 응집제를 이용한 광산폐수의 중금속 및 음이온 제거)

  • 이해승;이영신;현근우
    • Journal of environmental and Sanitary engineering
    • /
    • v.16 no.3
    • /
    • pp.80-86
    • /
    • 2001
  • This research was carried out to investigate the effect of microscopic silica matrix coagulation on heavy metals and anion removal in mining wastewater. pH and alkalinity played an important role to coagulate heavy metals such as Al, and Fe and an anion such as ${SO_4}^{2-}$ with silica matrix as well as NaOH. However, the efficiency to form coagulates was much greater in silica matrix-treated wastewater than NaOH-treated one. Fe in wastewater formed coagulation with both silica matrix and NaOH treatments resulting in lowering Fe content in wastewater at above pH 9. For Al removal in wastewater, silica matrix-treated wastewater at above pH 12.3 formed stable coagulate with Al, while NaOH-treated one did not. Alkalinities of 89 and 220 mg/L were required to stabilize silica matrix treated coagulate with Fe and Al, respectively. Reaction time of ten minute was required to provide enough reaction for coagulation between heavy metals and silica matrix. Heavy metals and anion leachates were much lower in coagulate with silica matrix than that with NaOH, which indicates that silica matrix could be used to remove heavy metals efficiently.

  • PDF