• 제목/요약/키워드: Coagulation System

검색결과 272건 처리시간 0.028초

혈액응고 기전에 대한 고찰 (Introduction to Coagulation System)

  • 유철주
    • Neonatal Medicine
    • /
    • 제18권1호
    • /
    • pp.1-5
    • /
    • 2011
  • Coagulation involves the regulated sequence of proteolytic activation of a series of proteins to achieve appropriate and timely hemostasis in an injured vessel. In the non-pathological state, the inciting event involves exposure of circulating factor VIIa to extravascularly expressed tissue factor, which brings into motion the series of steps which results in cell based model of coagulation. In the new concepts of coagulation system, initiation, amplification and propagation steps are involved to converse of fibrinogen to fibrin. The precisely synchronized cascade of events is counter-balanced by a system of anticoagulant mechanisms. Developmental hemostasis refers to the age-related changes in the coagulation system that are most marked during neonate and childhood. An understanding of these changes in crucial to the accurate diagnosis of hemostatic abnormalities in neonate and children. This review aims to elucidate the main events within the coagulation cascade as it is currently understood to operate in vivo, and also a short review of the anticoagulants as they relate to this model. Also this paper describes the common pitfalls observed in the clinical data related to the coagulation system in neonate to children.

응집·한외여과 조합공정에서 플럭스와 선속도가 막오염에 미치는 영향에 관한 연구 (A Study on Membrane Fouling by Flux and Linear Velocity in Coagulation/Ultrafiltration Membrane System)

  • 문성용;이상협;김승현;윤조희
    • 상하수도학회지
    • /
    • 제19권4호
    • /
    • pp.429-436
    • /
    • 2005
  • A coagulation/ultrafiltration membrane hybrid system was operated to treat river water with capacity of $0.06m^3/d$. The impact on membrane fouling by flux and linear velocity was investigated. It is known that pressure increase is proportional to flux increase. However, pressure increase was much faster than theoretical value in the pilot plant test. So it was suggested that flux was on important factor in ultrafiltration of continuous operation. Membrane fouling was decreased when linear velocity was increased. This phenomenon was found more obviously without coagulation. With the combination of coagulation and sedimentation, membrane fouling was not reduced conspicuously. Big particles formed during coagulation and sedimentation were destroyed by feed and circulation pumping, which resulted in little effect on membrane fouling reduction. The degree of destruction was similar at various linear velocities. In this study, the hollow fiber membrane was used and the system was operated in pressure type module. In case of the system used in this study, membrane fouling has been affected lightly by linear velocity variation when coagulation pretreatment was applied.

Recovery Increase by Recycling Backwash Residuals in Microfiltration System

  • Yu, Myong-Jin;Pak, Hong-Kyoung;Sung, Il-Wha
    • 환경위생공학
    • /
    • 제23권4호
    • /
    • pp.13-21
    • /
    • 2008
  • With the rise in membrane applications, residuals management has become a growing challenge for membrane system. The primary residuals of MF/UF (microfiltration/ultrafiltration) system results from the wastes generated during backwashing. Many regulatory agencies, utilities, and water process engineers are unfamiliar with the characteristics and methods for treatment and disposal of membrane residuals. Therefore, this study was performed to investigate the backwash residuals water quality from the pressurized system with and without pre-coagulation, and to suggest approaches for the backwash residuals treatment. Pressurized MF system was installed at Guui water intake pumping station and operated with raw water taken from the Han River. We compared performances with and without the recycling backwash residuals at flux conditions, 50 LMH and 90 LMH with and without pre-treatment (coagulation). Based on the results, recycling of backwash residuals in pressurized system with pre-coagulation showed applicability of backwash residuals managements. Moreover, the recovery rate also increased up to over 99%.

인라인 혼화 및 응집 시스템의 성능특성 (Performance characteristics of inline mixing and coagulation system)

  • 김동준;박상규;양희천
    • Journal of Advanced Marine Engineering and Technology
    • /
    • 제38권3호
    • /
    • pp.269-275
    • /
    • 2014
  • 본 연구는 PI 개념에 근거한 수처리용 인라인 혼화 및 응집 시스템의 성능특성에 대한 실험적 연구를 목적으로 한다. 3단 인라인 혼화 및 응집 시스템은 처리 원수 저장조, 응집제 주입 정량펌프, 혼화 및 응집관, 침전조 및 제어 판넬로 구성된다. 동일한 응집제와 응집보조제의 주입량 조건에서 응집제의 증가에 따른 탁도 제거율에 비해 응집보조제의 증가에 따른 탁도 제거율이 약 3배 정도 높게 나타났다. 동일한 혼화 및 응집 시간 조건에서 인라인 방식이 기계식에 비해서 평균적으로 약 4.6배 정도 탁도 제거율이 높게 나타났다.

Manufacture of Precheese Powder by Use of Low-temperature Renneting Made from Raw Milk Using Spray Dryer

  • An, Shuo-Feng;Piao, Jing-Zhu;Chang, Oun-Ki
    • 한국축산식품학회지
    • /
    • 제30권4호
    • /
    • pp.551-559
    • /
    • 2010
  • Among the food constituents, proteins differ in coagulation properties as compared to other constituents in food system. Especially milk protein coagulate through different pathways thus this coagulability can be used for manufacture of various dairy products or as a determinant of dairy product analysis. These milk coagulation methods include organic solvent, isoelectric point, trichloroacetic acid, Ca-sensitive casein, heavy metal ion and rennet coagulation. The coagulation experiment was performed using above parameters at $0^{\circ}C$ and $25^{\circ}C$ to find the dehydration conditions before coagulating for precheese powder making. After different chemical treatments, there was no coagulation at $0^{\circ}C$ rather at $25^{\circ}C$ whatever the mode of coagulation methods was. The appearance of precipitate with coagulation methods was quite different from above mentioned methods of coagulation illustrated by scanning electron microscope. These powders were used for fabrication of camembert cheese by renneting coagulation at $0^{\circ}C$, showing the possibility of cheese materials and of food additives for fabrication of products.

응집-UF 전처리 공정에 의한 잔류 금속염이 역삼투막에 미치는 영향 (Effect of residual metal salt on reverse osmosis membrane by coagulation-UF pretreatment process)

  • 고길현;김수현;강임석
    • 상하수도학회지
    • /
    • 제33권6호
    • /
    • pp.413-420
    • /
    • 2019
  • Pretreatment system of desalination process using seawater reverse osmosis(SWRO) membrane is the most critical step in order to prevent membrane fouling. One of the methods is coagulation-UF membrane process. Coagulation-UF membrane systems have been shown to be very efficient in removing turbidity and non-soluble and colloidal organics contained in the source water for SWRO pretreatment. Ferric salt coagulants are commonly applied in coagulation-UF process for pretreatment of SWRO process. But aluminum salts have not been applied in coagulation-UF pretreatment of SWRO process due to the SWRO membrane fouling by residual aluminum. This study was carried out to see the effect of residual matal salt on SWRO membrane followed by coagulation-UF pretreatment process. Experimental results showed that increased residual aluminum salts by coagulation-UF pretreatment process by using alum lead to the decreased SWRO membrane salt rejection and flux. As the salt rejection and flux of SWRO membrane decreased, the concentration of silica and residual aluminum decreased. However, when adjusting coagulation pH for coagulation-UF pretreatment process, the residual aluminum salt concentration was decreased and SWRO membrane flux was increased.

Alum과 PACl을 이용한 응집처리 (Chemical Coagulation Treatment Using Alum and PACl in Complex Wastewater)

  • 성일화
    • 한국환경보건학회지
    • /
    • 제35권1호
    • /
    • pp.53-57
    • /
    • 2009
  • In order to treat the complex wastewater containing organic compound and solids, pre-treatment system associated with molecular separation process were investigated. The reductions of COD and turbidity were obtained after coagulation processes using Alum (Aluminium sulfate, $Al_2(SO_4)_2{\cdot}18H_{2}O$) and PACl (poly aluminium chloride as 17% $Al_{2}O_{3}$). The results of study were as follows: using variable dosage of Alum, COD removal was highest at 4,000 mg/l, and the reduction of COD and turbidity was 42% and 92%, respectively. The optimum coagulation would be effective at pH 7.3 than pH 9.0 by the addition of alum at a concentration of 6,000 mg/l and PACl was add at 4.25% in raw complex wastewater with 2,000 mg/l alum at pH 7.3, the reduction of COD was reduced by 32%. But coagulation aid experiments indicated that PACl would be more effective in sludge separation ability than COD removal efficiency.

Bimodal 방법을 이용한 하전입자 응집 모델링 (Development of Simple Bimodal Model for Charged Particle Coagulation)

  • 김상복;송동근;홍원석;신완호
    • 한국입자에어로졸학회지
    • /
    • 제10권1호
    • /
    • pp.27-31
    • /
    • 2014
  • A simple bimodal model has been developed to analyze charged particle coagulation by modifying previously suggested bimdal model for evolution of particle generation and growth. In the present model, two monodisperse modes are used and 40 charge nodes are assigned to each mode to account both change of the particle size and charge distribution. In addition, we also implemented the effect of electrostatic dispersion loss in the present model. Based on the developed model, we analyzed coagulation of asymmetric bipolar charged particles by computing evolutions of particle number concentration, geometric mean diameter of particles, charge asymmetric ratio and geometric standard deviation of particle size distribution for various initial charge asymmetric ratios. The number concentration of asymmetric bipolar charged particles decreases faster than that of neutral particles but that does not give faster growth of particles since the electrostatic dispersion loss overwhelms particle growth by coagulation.

응집공정이 세라믹 정밀여과막 파울링에 미치는 영향 (Effect of coagaulation on ceramic microfiltration membrane fouling)

  • 황영진;임재림;최영종;왕창근
    • 상하수도학회지
    • /
    • 제23권4호
    • /
    • pp.459-469
    • /
    • 2009
  • It is well known that coagulation pretreatment can reduce foulants prior to membrane filtration. The purpose of this research was to investigate the effects of coagulation on fouling of ceramic microfiltration membrane($0.1 {\mu}m$) using pilot plant of $150m^3/day/train$ capacity. Train A membrane system has pretreatment process of ozonation and coagulation while train B has only coagulation. Two types of coagulation operation were investigated: back mixer(rapid mixing with or without slow mixing) which is a conventional mechanically stirred mixer and an inline static mixer. Ozone dose rate for train A was 1 mg/L and ozone contact time was 12 min. The coagulation dose(PACl 10% as $Al_2O_3$) rate was changed 20~40 mg/L according to experimental schedule. In this experimental conditions, the coagulation of back mixer type with rapid mixing(GT=72,000) and slow mixing(GT=45,000) was the best effective in reduction of ceramic membrane fouling regardless preozonation. Especially, the effect of inline static mixer was sensitive to change in water quality. Ozonation mainly affected irreversible fouling rather than reversible fouling in accordance with less adsorption of NOM on the membrane surface. Thus, the increase rate of the nomalized TMP(trans membrane pressure) at $25^{\circ}C$ for train A was relatively lower than that of train B under same coagulation process with same coagulant dosage. The best performance of ceramic membrane appeared in case of combined process with ozonation, therefore this integrated process is able to archive less coagulant dosing and secure a stability of ceramic membrane system.