• Title/Summary/Keyword: Coagulant Dispersion

Search Result 18, Processing Time 0.024 seconds

Preparation of Mono-dispersed Polyamide 6(Nylon 6) Micro-particle (단분산린 Polyamide 6(Nylon 6) 미세입자의 제조)

  • Cho, Hangu-Gu;Kim, Hyung-Joong
    • Polymer(Korea)
    • /
    • v.31 no.4
    • /
    • pp.322-328
    • /
    • 2007
  • Mono-dispersed polyamide 6(Nylon 6) micro-particles sized in $4{\sim}5\;{\mu}m$ diameter were prepared by dispersion polymerization of ${\varepsilon}-caprolactam$ in liquid paraffin as a dispersion medium. Potassium metal(K) as a catalyst was separately added twice over the anionic ring-opening polymerization of ${\varepsilon}-caprolactam$. The size, shape, and size-distribution of prepared particles were varied with the concentration of anti-coagulant as well as the amount of initiator and catalyst. As the initiator concentration was in the range of $0.97{\sim}1.17\;wt%$ in monomer, about 90.6% of yield was accomplished. In addition, the highest yield of well-spherically shaped micro-particles was achieved by adding about $1.3{\sim}1.4\;wt%$ of catalyst.

Rheological Behavior of Coal-Fly-Ash and Clay Slip (석탄회-점토계 슬립의 유동학적 거동)

  • 이기강;박천주;김유택;김석범;김정환
    • Journal of the Korean Ceramic Society
    • /
    • v.35 no.2
    • /
    • pp.180-184
    • /
    • 1998
  • It was examined that the rheological behaviors of fly ash 70wt%-clay 30wt% slip in which nonplastic fly ash was a major component. We have systematically investigated the effects of deflocculant(Tetrasodium pyrophosphate ; Na4P2O7 nH2O Sodium silicate; Na2SiO3) and coagulant(CaSO4) on the rheological behavior of ash-clay slip. Ash-clay slip have been characterized on the basis of the time dependent rheology which was done out by the gel-curve test. Dispersion mechanism of ash-clay slip is the steric stabilization by the Na2SiO3 coating of cenospheres surface. Coagulated slip seems to have the new network structure and shows the gellation behaviors which makes it possible to direct coagulated casting(DCC).

  • PDF

Evaluation of BR Blending Methods for ESBR/silica Wet Masterbatch Compounds

  • Kim, Woong;Ahn, Byungkyu;Mun, Hyunsung;Yu, Eunho;Hwang, Kiwon;Kim, Wonho
    • Elastomers and Composites
    • /
    • v.52 no.4
    • /
    • pp.242-248
    • /
    • 2017
  • Wet masterbatch (WMB) technology is studied to develop high-content and highly disperse silica-filled compounds. This technology refers to the solidification of surface-modified silica with a rubber solution or latex. Until now, researchs based on styrene butadiene rubber (SBR)/silica WMB has been mainly performed. However, the blending of SBR/silica WMB and BR is not known and is currently under research and development. Therefore, in this study, the BR blending method suitable for emulsion (ESBR)/silica WMB is investigated by measuring their cure characteristics and the mechanical and dynamic viscoelastic properties. As a result, it was confirmed that the blending of ESBR/silica WMB and BR/silica dry masterbatch is most appropriate. However, it showed a disadvantage compared with the conventional mixing method, which was due to the surfactant remained and the sulfuric acid used as the coagulant.

Evaluation of erythrocyte sedimentation rate in racehorse measured by westergren method (경주마(競走馬)에서 Westergren법(法)에 의한 적혈구 침강속도(沈降速度) 측정의 평가(評價))

  • Kim, Byoung-jin;Lee, Bang-whan;Lee, Chai-yong
    • Korean Journal of Veterinary Research
    • /
    • v.32 no.3
    • /
    • pp.421-427
    • /
    • 1992
  • The study was basically carried out to establish the appropriate condition for applying the Westergren method for erythrocyte sedimentation rate(W-ESR) in Throughbred racehorses at recess. To do this, we examined the correlationship among some factors including the kind of anticoagulants, optimal ambient temperature and reading time for W-ESR in healthy racehorses. The difference between the blood samples treated with only 3.8% solution of sodium citrate(SC) and both EDTA and SC as a coagulant, there was not recognized any significant difference(p<0.05) in the levels of W-ESR irrespective of the ambient temperature of $20^{\circ}C$ or $30^{\circ}C$. The best optimal ambient temperature for W-ESR in horses was proved at $30^{\circ}C$ resulting from the tendency of the most reduced dispersion in mean values analyaed from repeatly 4 times to the same blood samles compared with those of $10^{\circ}C$ and $20^{\circ}C$. The optimal reading time was determined as 60 minutes(Y=237.2~4.1X, $r^2=0.998$) and 70 minutes(Y=247.8~4.2X, $r^2=0.999$) under the same temperature of $30^{\circ}C$; the latter showed the better result on the basis of the correlation of packed cell volume(PCV) and ESR values. About 13 healthy racehorses, we compared the real values of W-ESR respectively obtained at 60 minutes and 70 minutes at $30^{\circ}C$ with the anticipated values of PCV by means of the analysis of linear regression equitation. As the result of this, the strong correlation between both of them was confirmed. For practical use of W-ESR in Thoroughbred racehorese, we can recommend the condition of 60 or 70 minutes for the optimal reading time as well as $30^{\circ}C$ for the best ambient temperature.

  • PDF

Effect of Orifice Type and Number on the Mixing and Flow Characteristics in In-line Mixer (관내 혼화장치의 오리피스 형상과 개수에 따른 혼화 및 유동특성)

  • Jeong, Seon Yong;Chung, Won Sik;Rhi, Seok Ho;Lee, Kye Bock;Lee, Dae Gyu
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.18 no.2
    • /
    • pp.6-13
    • /
    • 2017
  • This study examines the effect of the type and number of orifices in an in-line mixer to improve the mixing performance and pressure loss. Recently, in-line non-power-consuming mixers have been increasingly used to complement mechanical mixers, which have a long dwell time, noise, excessive energy consumption, and high maintenance costs. An in-line mixer with an orifice for efficient mixing in water treatment was examined by numerical analysis using the commercial code FLUENT. The flow characteristics of pressure loss and velocity distribution within the mixer and the mixing efficiency were compared with and without the orifices. The CFD results show that the mixing efficiency was improved, but the pressure loss was increased by the in-line mixer with an orifice. A sensitivity study was also done on the principal parameters.

A Study on Coagulation Process using Zirconium Silicate as a Coagulation-aid (지르코늄 실리케이트를 응집보조제로 이용한 응집공정에 관한 연구)

  • Cho, Jae-Seung;Yoon, Tai-Il;Jeon, Yu-Jae;Cho, Kyung-Chul
    • Journal of Korean Society of Environmental Engineers
    • /
    • v.31 no.3
    • /
    • pp.203-207
    • /
    • 2009
  • The concern of seriousness and harmful effects of environmental pollution is rising by the various water pollutions, appearances of new micro-noxious substances and increase of sustainable pollutants. The method is suggested that can effectively increase the removal of organic substances and several pollutants using a coagulation process. The experiment for characteristics of $ZrSiO_4$ (zirconium silicate) as a coagulation-aid was carried out for application to coagulation process with domestic wastewater and lake water, and the removal rate of the organic substances depending on a dosage was evaluated by PDA (Photometric Dispersion Analyzer) in this study. Zeta-potential of zirconium silicate solution was -32.22 mv at pH 7 and the lower negative(-) charge was detected in the more acidic conditions. Absorbance on $UV_{254}$ presented higher when zirconium silicate was added than in a domestic wastewater itself. Besides, the results by PDA experiment represented that injection of zirconium silicate could promote growing of floc. Tests for coagulation process were conducted by three ways which are pre-injection, co-injection and post-injection of zirconium silicate with alum. Accordingly, removal efficiency of organic substances increased over 15% in co-injection than in using of alum as a sole reagent. When a 20 mg/L of alum was used with a 10 mg/L of zirconium silicate, the removal efficiency was high up to 90%. Removal efficiency of $COD_{Cr}$ was improved more than 15% in case of dosage of coagulant either PAC (Poly aluminium chloride) or PACS (Poly aluminium chloride Silicate) together with zirconium silicate. As a result, the removal efficiency of $COD_{Cr}$ were 5~10% higher in a co-injection of zirconium silicate with a coagulant than a pre-injection and a post-injection but it of soluble substances was lower in a co-injection.

On-line Monitoring of the Flocs in Mixing Zone using iPDA in the Drinking Water Treatment Plant (정수장 응집혼화공정에서의 응집플럭 연속 모니터링)

  • Ga, Gil-Hyun;Jang, Hyun-Sung;Kim, Young-Beom;Kwak, Jong-Woon
    • Journal of Korean Society of Environmental Engineers
    • /
    • v.31 no.4
    • /
    • pp.263-271
    • /
    • 2009
  • This study evaluated the flocs forming characteristics in the mixing zone to increase the coagulation effect in the drinking water plant. As a measuring tool of formed flocs, on-line particle dispersion analyzer (iPDA) was used in Y drinking water plant. To evaluate the forming flocs, many parameters such as poly amine, coagulant dosing amount, raw water turbidity, and pH was applied in this study. During the periods of field test, poly aluminium chloride (PACl) as a coagulant was used. With the increase of the raw water turbidities, poly amine was also added as one of aids for increasing in coagulation efficiency. The turbidity and pH of raw water was ranged from 7 to 9 and from 25 to 140 NTU, respectively. The increasing of raw water turbidity brought the bigger floc sizes accordingly. From a regression analysis, $R^2$ value was 0.8040 as a function of T, raw water turbidity. Floc size index (FSI) was obtained from a correlation equation as follows; FSI = 0.9388logT - 0.3214 Also, polyamine gave the bigger flocs the moment it is added to the coagulated water in the rapid mixing zone. One of parameters influencing the floc sizes was the addition of powdered active carbon(PAC) in the mixing zone. In case of higher turbidity of raw water, $R^2$ value was 0.9050 in the parameters of [PACl] and [PAC]; FSI = $0.0407[T]^{0.324}[PACI]^{0.769}[PAC]^{0.178}$ On-line floc monitor was beneficial to evaluate the flocs sizes depending on the many parameters consisting raw water properties, bring the profitable basic data to control the mixing zone more effectively.

Recovery of Poly(3-hydroxybutyrate) from the Coagulated Cells of Alcaligenes eutrophus. (응집 처리한 Alcaligenes eutrophus 균체로부터 poly(3-hydroxybutyrate)의 회수)

  • 조경숙;홍은화;류희욱;장용근
    • Microbiology and Biotechnology Letters
    • /
    • v.26 no.3
    • /
    • pp.206-212
    • /
    • 1998
  • The effects of the pretreatment with coagulants on the recovery efficiency of poly (3-hydroxybutyrate, PHB) synthesized in Alcaligenes eutrophus were investigated. Al-base or Fe-base coagulants, and the dispersion method of 30% hypochlorite solution and chloroform were used as coagulants and PHB recovery method, respectively The recovery efficiency of PHB from the cells harvested with Al-base coagulants at the range from 0 to 1000 mg-Al/L was similar to that from cells harvested without the coagulants. At these conditions, the concentrations of residual aluminium in the purified PHB were below 250 mg-Al/kg-PHB, indicating the effect of residual aluminum on the characteristics of the purified PHB can be insignificant. When the dosage of coagulants was over 1000 mg-Al/L, the PHB recovery remarkably decreased with increasing the coagulant dosage. However, the PHB recovery could be enhanced by the use of 50% hypochlorite solution instead of 30% hypochlorite solution. Even though the reduction of PHB recovery efficiency was not found by using Fe-base coagulants, the purified PHB was stained pale red due to residual iron, These results suggest that the use of Al-base coagulants did not exert bad influence on neither PHB recovery efficiency and PHB purity.

  • PDF