• 제목/요약/키워드: Co-solvent system

검색결과 148건 처리시간 0.027초

Lipase를 이용한 (S)-3-acetoxy-2-methylpropanol의 제조

  • 서영배;서연찬;이갑득
    • 한국미생물·생명공학회지
    • /
    • 제24권2호
    • /
    • pp.213-216
    • /
    • 1996
  • Optically active carboxylic acid, D-(-)-$\beta$-hydroxyisobutyric acid {(D)-(-)-HIBA} is a useful chiral starting material for the preparation of enantiomerically pure bioactive compounds which have a chiral methyl carbon center in the molecule such as captopril, $\alpha$-tocopherol, erythromycin A, muscone and so on. (S)-3-Acetoxy-2-methylpropanol can be used as the precursor of (D)-(-)-HIBA, that is, chemical oxidation of the hydroxyl group and subsequent hydrolysis of acyl group in (S)-3-acetoxy-2-methylpropanol affords D-(-)-$\beta$-hydroxyisobutyric acid. (S)-3-Acetoxy-2-methyl-propanol was prepared by lipase-catalyzed asymmetric hydrolysis. In the enzymatic hydrolysis system, lipase AY (Candida rugosa) provided the expected (S)-3-acetoxy-2-methylpropanol in 60% e.e. of the enantiomeric purity under the phosphate buffer and organic co-solvent system.

  • PDF

Poly(ethylene-co-octene)과 탄화수소 2성분계 혼합물의 상거동에 대한 고분자 농도 및 용매의 영향 (Effect of Polymer Concentration and Solvent on the Phase Behavior of Poly(ethylene-co-octene) and Hydrocarbon Binary Mixture)

  • 이상호;정성윤;김효준;박경규
    • Elastomers and Composites
    • /
    • 제39권4호
    • /
    • pp.318-323
    • /
    • 2004
  • Poly(ethylene-co-13.8 mol% octene) ($PEO_{13.8}$), Poly(ethylene-co-15.3 mol% octene) ($PEO_{15.3}$)과 분자크기와 분자구조가 각각 다른 탄화수소의 2성분계 혼합물에 대한 cloud-point, bubble-point 압력을 $150^{\circ}C$, 450 bar까지 측정하였다. (PEO+n-프로판), (PEO+n-부탄) 2성분계 혼합물에서 cloud-point 곡선이 측정되었고, (PEO+n-펜탄) 혼합물에서는 cloud-point와 bubble-point 곡선이 모두 측정되었다. (PEO+시클로펜탄), (PEO+시클로헥산), (PEO+시클로 헵탄), (PEO+시클로옥탄) 2성분계 혼합물에서는 bubble-point 곡선이 측정되었다. (PEO+탄화수소) 2성분계의 압력-조성 등온곡선과 온도-조성 등압곡선은 PEO의 농도가 약 5 wt%일 때 각각 최고점과 최저점을 가졌다. (PEO+탄화수소) 2성분계는 PEO 농도가 5 wt%에서 임계조성을 가진다. PEO는 n-알칸과 시클로알칸 용매에서 LCST 유형의 상거동을 보여주며, 탄화수소의 분자크기가 증가할수록 PEO의 녹는 압력은 감소하였고 용해도는 증가하였다.

Polycaprolactone, 디클로로메탄, 이산화탄소로 구성된 3성분계 고압 상거동 측정 (High-Pressure Phase Behavior of Polycaprolactone, Carbon Dioxide, and Dichloromethane Ternary Mixture Systems)

  • 권정민;신헌용;김수현;김화용
    • Korean Chemical Engineering Research
    • /
    • 제53권2호
    • /
    • pp.193-198
    • /
    • 2015
  • Polycaprolactone, Dichloromethane, 이산화탄소로 구성된 3성분계 고압 시스템의 상거동 측정 실험은 가변 부피 셀 장치를 이용해서 측정했다. 실험의 온도범위는 313.15 K에서 353.15 K, 압력은 약 300 bar까지 측정했으며 실험결과는 Polycaprolactone의 질량 분율이 1.0%, 2.0%, 3.0%일 때 온도와 이산화탄소/Dichloromethane의 질량 분율로 정리했다. 또한 실험 결과는 hybrid 상태방정식 (Peng-Robinson 상태방정식과 SAFT 상태방정식의 혼합형태) 을 이용하여 열역학적으로 검증하였으며, 혼합규칙은 반데르 발스의 단일 유체 혼합규칙을 사용했다. 이 다성분계 시스템에서 이원 상호 작용 파라미터 등, 각종 파라미터는 심플렉스 알고리즘을 통해 최적화했다.

제올라이트 흡착농축 및 촉매연소를 이용한 인쇄공정에서 발생되는 저농도 대풍량 VOCs 가스 제거 (A Treatment of Low-leveled High-volume VOCs Emitted from Printing Process Using Concentrator with Zeolite Adsorptive Honey Rotor and Catalytic Combustion System)

  • 박찬규;유남종;최보경;고광백
    • 한국환경과학회지
    • /
    • 제18권3호
    • /
    • pp.283-288
    • /
    • 2009
  • This is a study on the volatile organic compounds(VOCs) concentrator with zeolite adsorptive honey rotor and catalytic combustion system for abating VOCs emitted from printing industry. VOCs emitted from the printing industry is mainly caused by organic solvent of printing ink. The content of organic solvents in printing ink varies from 40% to 75% and its content in the gravure ink is higher than that in any other ink. The average concentrations of each VOCs are 139 ppm for toluene, 152.1 ppm for MEK, 256.9 ppm for methanol and 42.9 ppm for isopropyl alcohol. We used zeolite honeycomb for absorbent of VOCs concentrator and palladium for catalyst combustion system. This system abated over 96% of emitted total VOCs, 98% of toluene, 100% of MEK, 92% of methanol and, 100% of isopropyl alcohol. It is concluded that the low-leveled high-volume VOCs emitted from printing process were removed almost by concentrator with zeolite adsorptive honey rotor and catalytic combustion system.

액체 이산화탄소 이용한 Monasil PCA 추출에 대한 연구 (A Study on the Extraction of Monasil PCA using Liquid CO2)

  • 조동우;오경실;배원;김화용;이갑수
    • Korean Chemical Engineering Research
    • /
    • 제50권4호
    • /
    • pp.684-689
    • /
    • 2012
  • Poly(acrylic acid) (PAA) 구형 입자는 바이오 분야의 소재에서부터 전자 재료에 이르기까지 다양한 분야에 사용되는 고분자 물질이다. 이를 생산하기 위해서는, 분산제(surfactant)를 이용한 중합 방법으로 합성을 한 후, 사용한 분산제를 제거하기 위한 별도의 Purification 과정을 거치게 된다. 일반 유기 용매를 사용하면 막대한 폐수 발생, 별도의 분리 공정 추가, 잔류 용매의 가능성 등의 문제점이 발생한다. 이에 이러한 문제를 해결하고자, 액체 이산화탄소를 용매로 하여, high-pressure Soxhlet extraction 방법을 개발하였다. 본 연구에서는 compressed liquid dimethyl ether (DME) 상에서 PAA 분산 중합에 사용된 pyrrolidene carboxylic acid-g-poly (siloxane) 계열의 분산제, Monasil PCA 제거하는 연구를 진행하였다. 추출된 PAA 입자의 모양은 field emission scanning electron microscopy (FE-SEM)으로 확인을 하였고, Monasil PCA의 농도는 Inductively Coupled Plasma-Optical Emission Spectrometer (ICP-OES)로 분석하였다. 용매의 효과를 비교하기 위해서, 액체 이산화탄소와 n-hexane과 liquid DME를 대상으로 추출 실험을 하였다. 그 결과 n-hexane의 경우 일부 정제된 PAA 구형 입자를 얻을 수 있었지만, 일부는 n-hexane 증기의 높은 열에 의해서 변형된 형태의 입자를 얻었다. Liquid DME의 경우엔, 추출이 잘 되지 않았다. 액체 $CO_2$를 이용하는 경우에 구형의 형태는 유지하면서 분산제가 제거된 입자를 얻을 수 있었다. 그리고 최적 운전 조건을 알기 위해서 8시간 동안 재비기와 응축기의 온도를 달리하면서 실험을 실시하였다. 그 결과 추출기의 온도가 $19.6{\pm}0.2^{\circ}C$, 압력이 $51.5{\pm}0.5$ bar일 때, 가장 좋은 제거 효율을 보였다.

다채널 액상 미세 추출 시스템 설계 및 제작 (Multichannel Liquid Phase Microextraction System)

  • 장신걸;정석;박상범
    • 한국기계가공학회지
    • /
    • 제19권10호
    • /
    • pp.1-7
    • /
    • 2020
  • In this study, a multichannel gas-liquid microextraction system is designed by integrating the automatic elution of extraction line and multichannel gas-purging liquid phase microextraction. The system uses an injection pump and inert gas to push the extraction solvent to a sample bottle of a gas-phase color autosampler and then implements multichannel gas-liquid microextraction and gas chromatography-mass spectrometry. The system also employs a three-way integrated micro-high-temperature heater, syringe pump, and microflow controller to realize the simultaneous processing of multiple groups of samples, thus improving the sample pretreatment speed and reproducibility and reducing human error. Autoinjection experiments were implemented with polycyclic aromatic hydrocarbon standard samples. The experiments show that the average recovery rate of the system exceeds 70%, and the relative standard among the channels is less than 15%.

가용화 조성물과 난용성 약물군을 함유하는 고체분산체의 용출양상 (Dissolution Profiles of Solid Dispersions Containing Poorly Water-Soluble Drugs and Solubilizing Compositions)

  • 김태완;최춘영;;권경애;이범진
    • Journal of Pharmaceutical Investigation
    • /
    • 제32권3호
    • /
    • pp.191-197
    • /
    • 2002
  • Polymer based physical mixtures or solid dispersions containing solubilizing compositions[OA, tween80 and SLS] were prepared using a spray-dryer. Lovastatin(LOS), simvastatin(SIMS), aceclofenac(AFC) and cisapride(CSP) were selected as poorly water-soluble drugs. Dextrin, poly(vinylalcohol) (PVA), poly(vinylpyrrolidone)(PVP) and polyethylene glycol(PEG) were chosen as solubilizing carriers for solid dispersions. The solid dispersions containing solubilizing compositions without drug were prepared without using organic solvents or tedious changes of formulation compositions. This system could be used to quickly screen the dissolution profiles of poorly water-soluble drugs by simply mixing with drugs thereafter. In case of solid dispersion containing drug, organic solvent systems could be used to solubilize model drugs. The dissolution rates of the drugs were higher when mixed with drug and solid dispersions containing solubilizing compositions. However, solid dispersions of LOS, AFC, and CSP simultaneously containing drug and solubilizing compositions in organic solvent systems were more useful than physical mixtures of drug and solid dispersions without drug except SIMS. Based on solubilizing capability of polymer based physical mixtures in gelatin hard capsules, optimal solid dispersion system of poorly water-soluble drugs could be formulated. However, it should be noted that dissolution rate of poorly water-soluble drugs were highly dependent on drug properties, solubilizing compositions and polymeric carriers.

고전압 구동 Li2MnO3-LiMO2(M=Ni, Co, Mn)/graphite 시스템에서의 전지 수명 및 고온 방치 특성 향상에 효과적인 플루오로 화합물계 전해액에 대한 연구 (Improved Cycle Life and Storage Performance in High-Voltage Operated Li2MnO3-LiMO2(M=Ni, Co, Mn)/Graphite Cell System by Fluorine Compounds as Main Electrolyte Solvent)

  • 유정이;신우철;이병곤
    • 전기화학회지
    • /
    • 제16권3호
    • /
    • pp.162-168
    • /
    • 2013
  • $Li_2MnO_3-LiMO_2$(M=Ni, Co, Mn) 나노 복합체는 높은 이론 용량을 가지고 있어 전기 자동차용 2차 전지 활물질 재료로 많은 연구가 진행되고 있다. 하지만 $Li_2MnO_3-LiMO_2$(M=Ni, Co, Mn)로부터 250 mAh/g 이상의 용량을 구현하기 위해서는 4.4 V 이상의 구동전압이 필요하며, 이러한 높은 구동 전압은 전지의 수명 및 고온 방치 특성의 저해 요소로 작용하고 있다. 본 연구에서는 이러한 문제점을 개선하기 위해서 FEC (Fluoroethylene carbonate), 플루오로알킬 에테르, $LiPF_6$가 주성분인 신규 전해액(F-based EL)을 설계하였다. F-based EL은 1.3 M $LiPF_6$ EC/EMC/DMC (3/4/3, v/v/v) (STD) 대비 안정한 SEI를 형성하며, 산화 안정성이 뛰어나 $Li_2MnO_3-LiMO_2$(M=Ni, Co, Mn)/graphite 셀의 수명 및 방치 중 가스 저감에 효과가 있음을 확인할 수 있었다.

벤젠과 노말헥산 혼합물의 최소자연발화온도 거동에 관한 연구 (A Study of Minimum Autoignition Temperature Behavior (MAITB) of Benzene and n-Hexane Mixture)

  • 하동명;김규현
    • 한국화재소방학회논문지
    • /
    • 제27권1호
    • /
    • pp.8-13
    • /
    • 2013
  • 최소자연발화온도는 가연성액체의 안전한 취급을 위해서 중요한 지표가 된다. 본 연구에서는 ASTM E659 장치를 이용하여 가연성 혼합물인 Benzene과 n-Hexane 계의 최소자연발화온도와 발화지연시간을 측정하였다. 2성분계를 구성하는 순수물질인 Benzene과 n-Hexane의 최소자연발화온도는 각 각 $583^{\circ}C$, $240^{\circ}C$로 측정되었다. 그리고 측정된 Benzene과 n-Hexane 계의 최소자연발화온도는 제시된 식에 의한 예측값과 적은 평균절대오차에서 일치하였다.

Preparation and Stability Evaluation of Docetaxel-Loaded Oral Liposome

  • Chon, Chong-Run;Kim, Hyun-Mi;Lee, Pung-Sok;Oh, Eui-Chaul;Lee, Ma-Se
    • Journal of Pharmaceutical Investigation
    • /
    • 제40권2호
    • /
    • pp.85-90
    • /
    • 2010
  • Docetaxel-loaded liposomes were prepared by emulsion-solvent evaporation method, then coated with chitosan at room temperature and lyophilized. This system was designed in order to improve solubility and stability of docetaxel in the GI tract for oral drug delivery. The solubilizing effect of some frequently used solubilizers and/or liposome was determined. Among the results docetaxel-loaded liposomes prepared with 0.5% TPGS as a solubilizer showed 100-fold higher solubility than docetaxel. In a stability test, mean particle size of different liposome formulations was measured by a particle size analyzer in simulated gastric fluid (SGF) and in simulated intestinal fluid (SIF). The particle size of uncoated liposomes was significantly increased compared with that of chitosan-coated liposomes in SGF, however, there was no significant difference between coated and uncoated liposome in SIF. It is evident that chitosan-coated liposomes were more stable in GI conditions. The release characteristics of docetaxel-loaded liposomes were also investigated in three buffer solutions (pH 1.2, 4.0, 6.8). Docetaxel release did not occur in pH 1.2 for 4 hrs. However, in pH 4.0 and 6.8 conditions, docetaxel was gradually released over 24 hrs as a sustained release. It seems that aggregation and precipitation of particles by electrostatic interaction might protect docetaxel from being released. In Conclusion, the results from this study show that the chitosan-coated liposomes may be useful in enhancing solubility and GI stability of docetaxel.