• Title/Summary/Keyword: Co-generation system

Search Result 806, Processing Time 0.027 seconds

A study on development of generation expansion planning considering CO2 emission constraints and Emission Trading (CO2 배출량 제약과 배출권거래제를 고려한 설비계획 방법론에 관한 연구)

  • Kim, Yang-Il;Lee, Seung-Hyun;Han, Seok-Man;Chung, Koo-Hyung;Kim, Bal-Ho H.
    • Proceedings of the KIEE Conference
    • /
    • 2006.11a
    • /
    • pp.46-48
    • /
    • 2006
  • WASP which is used to plan generation expansion has disadvantages that can't manage environmental factors and regional supply-demand planning. But with the effectuation of the United Nations Framework Convention on Climate Change (UNFCCC) and Kyoto Protocol, it is expected that reducing greenhouse gases affects power system in its long-term generation expansion planning. Therefore national countermeasures is needed. This paper formulates a mathematical model considering CO2 emission constraints and Emission Trading that will be enforced. This model is based on the ORIRES which was made by ESI, Russia and manages generation expansion planning. And this mathematical model is verified by studying a case system.

  • PDF

Development of Automatic Pipe ISO-Drawing and BOM Generation System (배관 제작, 설치 ISO 도면 및 BOM 정보 자동 생성 시스템 개발)

  • Woo IlGuk;Kim ShinHyung;Heo CheoIEun;Cho YongNam;Gu JaMin;Kim Daejin
    • Special Issue of the Society of Naval Architects of Korea
    • /
    • 2005.06a
    • /
    • pp.127-133
    • /
    • 2005
  • DSME has successfully developed the unified CAD system (DACOS) for the commercial ship based on its design know-how accumulated for several years. Currently, DSME is expanding the unified CAD system to plant and special ship design. In this paper, the development of pipe design, especially, isometric drawing and BOM(Bill of Material) generation will be introduced isometric drawing and BOM generation are major activities of pipe design in shipbuilding. The drawing is used for pipe construction and installation while the BOM is used for purchasing and manufacturing pipe line. These activities are time-consuming and tedious jobs done by designers because the drawing should be generated as a non-scaled symbolized drawing that can be easily understood and the BOM information should be extracted without mistake. Therefore, we implemented automatic isometric drawing and 80M generation system for pipe design. In this paper, the developed system and the used technology will as well be introduced and a design output in a plant project as an applied example will be illustrated.

  • PDF

Development of algorism to optimal operation of Power Generation considering Regional Regulation of CO2 Emission (지역별 CO2 배출량규제를 고려한 발전소 최적운전 알고리즘의 개발)

  • Kim, Yong-Ha;Kim, Young-Gil;Lee, Pyong-Ho;Jo, Hyun-Mi;Woo, Sung-Min
    • The Transactions of The Korean Institute of Electrical Engineers
    • /
    • v.59 no.11
    • /
    • pp.1936-1941
    • /
    • 2010
  • This purpose of this paper is to propose a methodology for optimal generating operation in power system to minimize the cost of generation subject to not only system constraints but also regional $CO_2$ emission constraints. To solve this ELD problem calculated range limit on minimum and maximum power outputs by regional Equal Generator how each regional capacity is connected into one and expressed Equal Fuel Cost Function considering regional $CO_2$ emission constraints. Accordingly, being modified regional load, new power outputs considering regional $CO_2$ emission constraints were calculated by ELD. The proposed model for evaluating availability is tested on IEEE RTS(Reliability Test System)-24 in detail.

A Study on Electric Capacity and CO2 by the Roof Top PV System of the Industrial Building in Korea (한국 산업용 건물지붕 적용 PV에 의한 발전량 및 CO2 분석연구)

  • Kim, Ji-Su;Lee, Eung-Jik;Hwang, Jung-Ha
    • Journal of the Korean Solar Energy Society
    • /
    • v.30 no.6
    • /
    • pp.131-136
    • /
    • 2010
  • The purpose of this study is to provide foundational data for expansion of solar generation in building application, a clean energy, by introducing applicability of solar power generation system on roofs of industrial buildings and computing expected amounts of power and carbon dioxides reduction. As methodologies of this study, after reviewing 120,000 domestic factories to verify the BIPV feasibility for industrial building sthrough theoretical considerations of solar generation system, we calculated BIPV application methods and subsequent expected power generation quantity and carbon dioxide reductions through roof type analysis. we analyzed four cases of expected power generation amounts of solar batteries according to application methods, and when considering that the main type of roofs are slant roofs according to the investigation result about roof forms of domestic industrial complexes, we believe that the module angle of a slant roof around $17^{\circ}$(case3) is most suitable for the application. Finally, we came up with 517,944[TOE] as the corresponding petroleum tonnage based on this computed expected power generation amount and the amount of 1,214,836[$tCO_2$] carbon dioxide reductions by calculating them by energy sources.

The Best Generation Mix considering CO2 Air Pollution Constraint ($CO_2$ 배출량제약을 고려한 최적전원구성)

  • Lee, Sang-Sik;Tran, TrungTinh;Kwon, Jung-Ji;Choi, Jae-Seok
    • Proceedings of the KIEE Conference
    • /
    • 2005.07a
    • /
    • pp.149-151
    • /
    • 2005
  • A new approach considering CO2 air pollution constraints in the long-term generation mix is proposed under uncertain circumstances. A characteristic feature of the presented approach in this paper is what effects give the air pollution constraints in long term best generation mix. Best generation mix problem is formulated by linear programming with fuel and construction cost minimization with load growth, reliability (reserve margin rate) and air pollutionconstraints. The proposed method accommodates the operation of pumped-storage generator. It was assumed in this study that the construction planning of the hydro power plants is given separately from the other generation plans. The effectiveness of the proposed approach is demonstrated by applying to the best generation mix problem of KEPCO-system, which contains nuclear, coal, LNG, oil and pumped-storage hydro plant multi-years.

  • PDF

Development and Performance Test of SOFC Co-generation System for RPG (SOFC를 이용한 가정용 열병합 발전시스템 개발 및 성능시험)

  • Lee, Tae-hee;Choi, Jin-Hyeok;Park, Tae-Sung;Choi, Ho-Yun;Yoo, Young-Sung
    • 한국신재생에너지학회:학술대회논문집
    • /
    • 2009.06a
    • /
    • pp.361-364
    • /
    • 2009
  • KEPRI has studied planar type SOFC stacks using anode-supported single cells and kW class co-generation systems for residential power generation. A 1kW class SOFC system consisted of a hot box part, a cold BOP part and a water reservoir. A hot box part contains a SOFC stack made up of 48 cells with $10{\times}10cm^2$ area and ferritic stainless steel interconnectors, a fuel reformer, a catalytic combustor and heat exchangers. Thermal management and insulation system were especially designed for self-sustainable operation. A cold BOP part was composed of blowers, pumps, a water trap and system control units. When a 1kW class SOFC system was operated at $750^{\circ}C$ with hydrogen, the stack power was 1.2kW at 30 A and 1.6kW at 50A. Turning off an electric furnace, the SOFC system was operated using hydrogen and city gas without any external heat source. Under self-sustainable operation conditions, the stack power was about 1.3kW with hydrogen and 1.2kW with city gas respectively. The system also recuperated heat of about 1.1kW by making hot water. Recently KEPRI developed stacks using $15{\times}15cm^2$ cells and tested them. KEPRI will develop a 5 kW class CHP system using $15{\times}15cm^2$ stacks by 2010.

  • PDF

A Study of Power Quality Monitoring System Using Web Technology (웹 기술을 이용한 전기품질 감시시스템 연구)

  • Lee, K.S.;Lim, S.I.;Lee, S.J.;Lee, D.W.;Park, D.H.;Kim, J.H.
    • Proceedings of the KIEE Conference
    • /
    • 2003.07a
    • /
    • pp.148-150
    • /
    • 2003
  • A meaning of power quality has changed, which affects on an environmental change of existing electricity supply markets. Today, it should take both consumers and suppliers into consideration to develop information and communication technology and to increase the use of power and electronic equipments. As a result, it is necessary to develop a system to monitor power quality and to display data. In this paper, a system, as a power quality monitoring equipment, which can use protective replays with progress of microprocessor technology and provide information in the intranet/internet circumstances using web-based architecture is described.

  • PDF

Fuel cell system for SUAV using chemical hydride - I. Lightweight hydrogen generation and control system (화학수소화합물을 이용한 소형 무인항공기용 연료전지 시스템 연구 - I. 경량 수소 발생 및 제어 장치)

  • Hong, Ji-Seok;Jung, Won-Chul;Kim, Hyeon-Jin;Lee, Min-Jae;Jeong, Dae-Seong;Jeon, Chang-Soo;Sung, Hong-Gye;Shin, Seock-Jae;Nam, Suk-Woo
    • Journal of the Korean Society for Aeronautical & Space Sciences
    • /
    • v.41 no.3
    • /
    • pp.226-232
    • /
    • 2013
  • A compact hydrogen generation device of fuel cell system using chemical hydride storage technique was designed to fit the propulsion device requirement of a small unmanned aerial vehicle(SUAV). For high efficient, compact, and lightweight hydrogen generation control device, the Co-B catalyst hydrogen conversion rate by $NaBH_4$ aqueous solution flux is measured so that the proper amount of Co-B catalyst for maximum hydrogen generation of 100W stack was proposed. A compact hydrogen generation device is controlled by pump's on/off using its own internal pressure and consumes fuel in high efficiency through a dead-end type fuel cell. The fuel cell system has stable operation for a planed flight profile. The system operates up to maximum 7 hours and at least 4 hours for tough flight profiles.

Development of a Highly Efficient Boiler System Using a Diesel Engine

  • Lee, D.-H;Lee, D.-Y;Jo, M.-C;Cho, H.-N;Kim, Y.-S
    • Journal of Advanced Marine Engineering and Technology
    • /
    • v.28 no.2
    • /
    • pp.367-375
    • /
    • 2004
  • We have developed a highly efficient boiler system using the 2,600cc Diesel engine. In this system, the co-generation concept is utilized in that the electric power is produced by the generator connected to the engine, and waste heat is recovered from both the exhaust gases and the engine itself by the shell-and-tube heat exchangers. The heat exchanger connected to the engine outlet is specially designed such that it not only recovers waste heat effectively from the exhaust gases, but significantly reduces an engine noise. It is found that the total efficiency(thermal efficiency plus electric power generation efficiency) of this system reaches maximum 96.3% which is about 15% higher than the typical Diesel engine boiler system currently being used worldwide.

A web-based power quality monitoring system in the Substation Automation System (변전소 자동화 환경에서 웹 기반 전기품질 감시 시스템)

  • Park D. H.;Lim S. J.;Shin J. H.;Lim S. I.;Lee S. J.
    • Proceedings of the KIEE Conference
    • /
    • summer
    • /
    • pp.378-380
    • /
    • 2004
  • Along with the increase of the importance of power quality, many various systems are dedicated in the analysis of power quality nowadays. But there still exists the same problems for realizing such kind of analysis systems well. One is the customization of the power quality measure devices; The other is an economic problem. This paper presents the usefulness and the advantage of the ICD (Intelligent Electronic Device) as the measure device of power quality And this paper detailedly describes the development procedure of web-based power quality monitoring system through ActiveX controls. Now this power quality monitoring system is already applied to the substation automation system.

  • PDF