• Title/Summary/Keyword: Co-generation system

Search Result 806, Processing Time 0.042 seconds

Localization Development of On-Site High Sodium Hypochlorite Generation (고농도 차아염소산나트륨 발생장치 국산화 개발)

  • Kim, Jung Sik;Shin, Hyun Su;Lee, Eun Kyoung;Jung, Bong Ik
    • Transactions of the KSME C: Technology and Education
    • /
    • v.1 no.1
    • /
    • pp.83-90
    • /
    • 2013
  • The purpose of this study is to replace existing liquid chlorine with localization of on-site high (12%) sodium hypochlorite generation system. On-site high (12%) sodium hypochlorite generation system is higher the current efficiency of 38.7%, 54.6% reduction of salt consumption, and 97.3% lower rate of chlorate than on-site low (0.8%) sodium hypochlorite generation system.

Co-Pilot Agent for Vehicle/Driver Cooperative and Autonomous Driving

  • Noh, Samyeul;Park, Byungjae;An, Kyounghwan;Koo, Yongbon;Han, Wooyong
    • ETRI Journal
    • /
    • v.37 no.5
    • /
    • pp.1032-1043
    • /
    • 2015
  • ETRI's Co-Pilot project is aimed at the development of an automated vehicle that cooperates with a driver and interacts with other vehicles on the road while obeying traffic rules without collisions. This paper presents a core block within the Co-Pilot system; the block is named "Co-Pilot agent" and consists of several main modules, such as road map generation, decision-making, and trajectory generation. The road map generation builds road map data to provide enhanced and detailed map data. The decision-making, designed to serve situation assessment and behavior planning, evaluates a collision risk of traffic situations and determines maneuvers to follow a global path as well as to avoid collisions. The trajectory generation generates a trajectory to achieve the given maneuver by the decision-making module. The system is implemented in an open-source robot operating system to provide a reusable, hardware-independent software platform; it is then tested on a closed road with other vehicles in several scenarios similar to real road environments to verify that it works properly for cooperative driving with a driver and automated driving.

EMTDC Model Development for Control & Protection Analysis of Co-Generation System based on On-site Characteristic Tests (현장 측정에 근거한 열병합 발전 시스템의 제어, 보호 해석용 EMTDC 모델 수립)

  • Kim, Hak-Man;Shin, Myong-Chul
    • Journal of the Korean Institute of Illuminating and Electrical Installation Engineers
    • /
    • v.20 no.5
    • /
    • pp.85-91
    • /
    • 2006
  • Co-generation systems have been spreading rapidly over the past 10 years in Korea and most of these systems are interconnected with electric power systems. However, better control and protection models are still needed for analysis of these systems to ensure stable operation with the grid. This paper proposes improved EMTDC models for control fad protection analysis of grid-connected co-generation systems. Through on-site characteristic testing, the models were developed and the model parameters were determined. The models were applied to a field co-generation system, and analysis of control and protection was performed showing a good match to the simulation results.

Research about composition of protective system in Co-Generation (PSCAD/EMTDC를 이용한 소형열병합발전 설비에서 보호계전시스템의 구성에 관한 연구)

  • Kim, Y.H.;Choi, S.K.;Lee, Bum;Lee, S.J.;Lee, K.S.;Park, N.C.;Lee, Y.S.
    • Proceedings of the KIEE Conference
    • /
    • 2006.07a
    • /
    • pp.458-459
    • /
    • 2006
  • System has to be applied as protection at existent supply of electric power system and link is different from when system is operated individually Co-Generation. When equipment is driven Co-Generation that associate in existent equipment in this paper, displayed operating state of function by duty of protective system.

  • PDF

A study of the effect on variable generation cost by the variation of $CO_2$ emission trading price ($CO_2$ 거래비용 변화에 따른 발전원가(변동비) 영향 분석)

  • Jung, Young-Beom;Lee, Young-Eal;Yoon, Yong-Beum
    • Proceedings of the KIEE Conference
    • /
    • 2007.07a
    • /
    • pp.822-823
    • /
    • 2007
  • It is easily can be expected that Korea cannot be free under the regulation, because Korea is one of the major $CO_2$ emitter in the world. Even though Korea currently doesn't have any obligation to mitigate the carbon emission, power industry needs to study the effect of that. this paper aims to analyze the change of economic loading order for generation dispatch by various carbon price, looking at each plant's or generator's variable generation cost per unit electricity(kWh) that consists of basic generation price calculated by automatic generation system planning model, WASP 4.0, and $CO_2$ price per unit electricity generation.

  • PDF

Development of the Information Display Device for Photovoltaic Power Conditioning System (태양광 발전용 전력변환장치의 정보표시장치 개발)

  • Lee, Hyun-Doo;Jeon, Se-Bong;Kim, Jong-Gyu;Woo, Myung-Hoo;Ryu, Seung-Pyo;Lee, Se-Hyun
    • Proceedings of the KIPE Conference
    • /
    • 2008.06a
    • /
    • pp.601-603
    • /
    • 2008
  • The main purpose of this study is to design and develop the information display device for power conditioning system of photovoltaic power generation system. The function of this device is to display the information, communicate with PCS controller and store the special information. The developed device is tested to verify the performance and experimental results show the excellent performance. An actual running test is being carried out to verify the reliability of the device including PCS by applying it to 10kW level photovoltaic power generation system established in Ulsan College.

  • PDF

A Research on Energy Reduction Effect of Cogeneration System of Apartment Houses (공동주택 열병합발전시스템도입에 의한 에너지 절감효과에 관한 연구)

  • Jeon, Min-Kyung;Kim, Ju-Young;Hong, Won-Hwa
    • Proceeding of Spring/Autumn Annual Conference of KHA
    • /
    • 2006.11a
    • /
    • pp.484-487
    • /
    • 2006
  • Today, the age of high oil prices is continued, due to the energy demand is on the increase and human principlal energy sorce, fossil fuel. As an alternative plan of energy saving, co-generation system that produces power and thermal energy at the same time has actively developed. In 1960s, co-generation system was introduced to Korea and since 2000 it has diffused throughout the apartment house. Therefore, objectives of this study are to analyze the energy reduction effects in the region 4 apartment houses of Daegu and Kyungbuk regionand set up a plan for its expansion in the future.

  • PDF

SAR Processing Software for Ground Station

  • Kwak, Sung-Hee;Lee, Young-Ran;Shin, Dong-Seok;Park, Won-Kyu
    • Proceedings of the KSRS Conference
    • /
    • 2003.11a
    • /
    • pp.634-636
    • /
    • 2003
  • Satrec Initiative (Si) is developing a ground processing system for Synthetic Aperture Radar (SAR) data. SAR provides its own illumination and is not dependent on the light from sun, thus permitting continuous day/night operation and all-weather imaging. The system is capable of producing standard level products from SAR signal. Hence, the system should be able to perform matched filtering, range compression, azimuth compression, multi-look image generation, and geocoded image generation. This paper will describe the processing steps including algorithms, design, and accuracy of the Si's SAR processing system by comparing with commercial software.

  • PDF

Influence of $CO_2$ Removal on the Performance of IGCC plant (IGCC 플랜트에서 $CO_2$ 제거가 성능에 미치는 영향)

  • Cha, Kyu-Sang;Kim, Young-Sik;Lee, Jong-Jun;Kim, Tong-Seop;Sohn, Jeong-Lak;Joo, Young-Jin
    • 한국신재생에너지학회:학술대회논문집
    • /
    • 2008.10a
    • /
    • pp.242-245
    • /
    • 2008
  • In the power generation industry, various efforts are needed to cope with tightening regulation on carbon dioxide emission. Integrated gasification combined cycle (IGCC) is a relatively environment friendly power generation method using coal. Moreover, pre-combustion $CO_2$ removal is possible in the IGCC system. Therefore, much effort is being made to develop advanced IGCC systems. However, removal of $CO_2$ may affect the system performance and operation through reduction of fuel gas supplied to the gas turbine. This study predicts system performance change due to $CO_2$ capture by pre-combustion process from the normal IGCC performance without $CO_2$ capture and presents results of design parametric analysis.

  • PDF