• Title/Summary/Keyword: Co-fire

Search Result 942, Processing Time 0.029 seconds

Feasibility Analysis of a Wood Bioenergy System in an Apartment Complex (목질계 바이오에너지 시스템의 공동주택 적용성 평가)

  • Ko, Myeong-Jin;Choi, Mi-Young;Choi, Doo-Sung;Chang, Jae-Dong;Kim, Yong-Shik
    • Journal of the Korean Solar Energy Society
    • /
    • v.30 no.6
    • /
    • pp.81-88
    • /
    • 2010
  • This study compared the feasibility of utilizing a wood bioenergy system over a conventional central heating and cooling system and a cogeneration system in an apartment complex. The performance of the three systems were compared in the following areas: energy consumption, environmental impact(output of CO2, CH4, and N2O), and life cycle cost. The results showed that energy performance of the wood bioenergy system was similar to the conventional central system (just a 1% improvement) but the cogeneration system showed a 12% reduction in energy consumption compared to the conventional system. In terms of environmental impact, the bioenergy system reduced pollutants by 50% while the cogeneration system reduced pollutants by 30% compared to the conventional system. Life cycle cost analysis indicated bioenergy and cogeneration to have an 8% and 19% improvement over the conventional system. The findings of the study suggest that it is both economically and environmentally beneficial to use a wood bioenergy system in place of a conventional central heating and cooling system in apartment complexes.

Various modeling approaches in auto insurance pricing (다양한 모형화를 통한 자동차 보험가격 산출)

  • Kim, Myung-Joon;Kim, Yeong-Hwa
    • Journal of the Korean Data and Information Science Society
    • /
    • v.20 no.3
    • /
    • pp.515-526
    • /
    • 2009
  • Pricing based on proper risk has been one of main issues in auto insurance. In this paper, we review how the techniques of pricing in auto insurance have been developed and suggest a better approach which meets the existing risk statistically by comparison. The generalized linear model (GLM) method is discussed for pricing with different distributions. With GLM approach, the distribution of error assumed plays an main role for the best fit corresponding to the characteristics of dependent variables. Tweedie distribution is considered as one of error distributions in addition to widely used Gamma and Poisson distribution. With these different types of error assumption for estimating the proper premium in auto insurance, various modeling approaches are possible. In this paper, various modeling approaches with different assumptions for estimating proper risk is discussed and also real example is given by assuming different.

  • PDF

An Approach to Risk Assessment of City Gas Pipeline (도시가스 배관의 위험평가 방법론 제시)

  • Park Kyo-Shik;Lee Jin-Han;Jo Young-Do;Park Jin-Hee
    • Journal of the Korean Institute of Gas
    • /
    • v.7 no.1 s.18
    • /
    • pp.33-40
    • /
    • 2003
  • In this work, a novel approach was introduced to assess cost of loss resulting from risk as well as to help deciding inspection period through quantifying risk. In order to quantifying risk of city gas pipeline, frequency and consequence analysis were required. The main causes of city gas accident were analyzed to be digging, external corrosion, ground movement, and equipment failure. Tools to evaluate frequency of each cause was also suggested. Among city gas accidents, fire damage is the dominant one and mainly discussed; fatality, burning injury, and damage to building were estimated using the consequence model suggested. By combining frequency and consequence analysis, evaluating cost of risk management together with calculating example. This work could be applicable for city gas companies to plan how to manage risk most effectively.

  • PDF

A Study on the Optimized Design of the Helmets for Fire and Gas Safety (소방.가스안전용 헬멧의 최적설계에 관한 연구)

  • Cho, Seung-Hyun;Kim, Do-Hyun;Kim, Chung-Kyun
    • Journal of the Korean Institute of Gas
    • /
    • v.12 no.3
    • /
    • pp.24-30
    • /
    • 2008
  • In this paper, the stress and strain characteristics of a helmet shell structure have been analyzed by using the finite element method and Taguchi's design method as functions of the material properties, the thickness of a helmet, the thickness and the number of a bead frame. The optimized design of the helmets for a firefighter and a gas worker is very important for increasing the strength safety and an impact energy absorption capacity of a helmet shell due to an impulsive external force. Thus, the optimized design data of the helmet indicated that the uniform thickness of a helmet shell may be reduced for reducing the total weight of a helmet and increasing the strain energy absorption rate, but the thickness and the number of a bead frame would be increased for increasing the impact strength of the helmet.

  • PDF

The Development of Quantitative Audit System for Safety Management Systems based on Accident Database (사고 데이터베이스를 활용한 안전 관리 시스템의 정량적 Audit 시스템 개발)

  • Ahn, Sung Joon;Lee, Chang Jun
    • Journal of the Korean Society of Safety
    • /
    • v.28 no.1
    • /
    • pp.40-46
    • /
    • 2013
  • In the chemical process industries, accidents have a high potential and large effects on catastrophic results. Therefore the safety management for accident prevention plays a crucial role to guarantee the process safety. For these reasons, many systematic methods for safety management system have been widely employed in the fields of chemical processes. PSM (Process safety management) is one of most representative methods. The audit system, which is one of PSM system components, evaluates the performance of PMS system. However, most existing safety audit systems are not systematic and these are performed based on knowledges and experiences of various specialist. Moreover, the safety audit is only performed based on each independent technical component. So, the results of safety audit are not a quantitative index but only a series of commentaries. Finally, it is very difficult to obtain the comparison with other plants or industries. In this study, the novel systematic method and index-based accident database of auditing safety management systems for quantitative assessment are proposed. First, the elements of safety audit replace technical methods to categories of accident database. The F-N curve of each category for accident database is employed to derive the index for quantitative assessment. The Accidental Factor Risk Index (AFRI) is suggested for evaluating the effect of each element in accident database and safety audit system. The safety audit can be modified according to the proposed index.

A Study on the CMOS Camera robust to radiation environments (방사선 환경에 강인한 CMOS카메라에 관한 연구)

  • Baek, Dong-Hyun;Kim, Bae-Hoon
    • The Journal of Korea Institute of Information, Electronics, and Communication Technology
    • /
    • v.13 no.1
    • /
    • pp.27-34
    • /
    • 2020
  • Human access is restricted to environment where radiation sources are used, however observation equipment should be radiation-resistant as it is exposed. Therefore, if tungsten with the highest specific gravity and melting point and the lowest lead were selected to reduce the dose to the Cobalt 60 radiation source to 1/8, Tu had a volume of 432.6cm3, a thickness of 2.4cm, and Pb had a volume of 961cm3,, a thickness of 3.6cm. By applying this method, produced a radiation resistant CMOS camera with a camera module using a CMOS Image sensor and a radiation shielding structured housing. As a result of applying the head detachable 2M AHD camera (No. ①) that survived the experiment to select the optimal shielding thickness, when shielding the associated equipment such as cameras, adapters, etc. is achieved, it was confirmed that the design of the structure is appropriate by operating well at doses higher than 1.88×106rad. Therefore, it is expected to secure the camera technology and business feasibility that can be applied to high radiation environments.

Effect of $Al_2O_3$ Particle Size on Thermal Properties of Glass-Ceramics for LTCC Material (저온동시소성용 결정화 유리의 필러 사이즈가 열적 특성에 미치는 영향)

  • Kim, Jin-Ho;Hwang, Seong-Jin;Lee, Sang-Wook;Kim, Hyung-Sun
    • Proceedings of the Korean Institute of Electrical and Electronic Material Engineers Conference
    • /
    • 2007.11a
    • /
    • pp.281-281
    • /
    • 2007
  • Low Temperature Co-fired Ceramic (LTCC) technology has been used in electronic device for various functions. LTCC technology is to fire dielectric ceramic and a conductive electrode such as Ag or Cu thick film below the temperature of $900^{\circ}C$ simultaneously. The glass-ceramic has been widely used for LTCC materials due to its low sintering temperature, high mechanical properties and low dielectric constants. To obtain the high strength, addition of filler, the microstructure should have various crystals and low pores in a composite. In this study, two glass frits were mixed with different alumina size(0.5, 2, 3.7um) and sintered at the range of $850{\sim}950^{\circ}C$. The microstructure, crystal phases, thermal and mechanical properties of the composites were investigated using FE-SEM, XRD, TG-DTA, Dilatomer. When the particle size of $Al_2O_3$ filler increased, the starting temperatures for the densification of the sintered bodies, onset point of crystallization, peak crystallization temperature in the glass-ceramic composites decreased gradually. After sintered at $900^{\circ}C$, the glass frits were crystallized as $CaAl_2Si_2O_8\;and\;CaMgSi_2O_6$. The purpose of our study is to understand the relationship between the $Al_2O_3$ particle size and thermal properties in composites.

  • PDF

Development of Emergency Response System by Risk Assessment Methodology in Energy Facility (에너지 시설물의 위험성 평가에 따른 비상대응 시스템 구축)

  • Lee, Heon-Seok;Kang, Seung-Gyun;Jung, In-Hee;Kim, Bum-Su;Yoo, Jin-Hwan;Park, Chul-Hwan;Kim, Dae-Heum;Ko, Jae-Wook
    • Journal of the Korean Institute of Gas
    • /
    • v.12 no.2
    • /
    • pp.118-123
    • /
    • 2008
  • There are many facilities, such as facilities for high pressure gas storage and systems related to high pressure pipes, to handle hazardous materials in energy industries. Because the foundation of the proper risk analysis and management system has not been established, there is the possibility of an accident and Korea has met higher accident rate than developed countries. These accidents in energy facilities could cause great damage to facilities including the surrounding area, We have conducted the present research in order to systematize the emergency response system (ERS) using a lot of information on the degree of damage in an accident by consequence analysis.

  • PDF

TRANSFORMER EXPLOSION AND FIRE PREVENTION (변압기 폭발/화재 방지 기술)

  • Kim, Hyung-Seung;Magnier, Philippe
    • Proceedings of the KIEE Conference
    • /
    • 2007.07a
    • /
    • pp.93-94
    • /
    • 2007
  • An essential step for SERGI is to show the TRANSFORMER PROTECTOR (TP) efficacy for all transformers and all types of rupture of insulation. Its research program philosophy is thus to maintain a strong connection between experiments and the theoretical developments. Up to now, two TP test campaigns have been performed, both under the worst conditions by creating low impedance faults leading to electrical arcs inside the transformer tank dielectric oil. In 2002, Electricite de France performed 28 TP tests. Then, in 2004, a second campaign of 34 TP tests was carried out by CEPEL, the Brazilian independent High Voltage Laboratory. For the 62 tests, each transformer was equipped with the TP, which reacts directly to the moving dynamic pressure peak, shock wave, caused by the low impedance fault. When an electrical arc occurs, only one pressure peak is generated. The initial energy transfer is almost instantaneous, and so is the phase change. Because of the oil inertia, the gas is very quickly pressurised. As it is more difficult to vaporise a liquid than to crack oil-vapour into smaller molecules, the arc location would mainly remain in the gaseous phase after and less gas will be produced. As a result, when comparing tests for which pressure peaks are respectively equal to 8 bar (116 psi) and 8.8 bar (127 psi), the corresponding arc energies vary by an order 10 of magnitude (0.1 MJ and 1 MJ respectively). The correlation of the results obtained between arc energy and dynamic pressure demonstrates that the arc energy is not the key parameter during transformer tank explosion, which is in opposition with the common electrical engineers belief.

  • PDF

Fabrication and Biocompatibility of Rutin-containing PHBV Nanofibrous Scaffolds (천연 항균물질 루틴을 함유하는 PHBV 나노섬유의 제조 및 생체적합성)

  • Chae, Won-Pyo;Xing, Zhi-Cai;Kim, Yong-Jin;Sang, Hie-Sun;Huh, Man-Woo;Kang, Inn-Kyu
    • Polymer(Korea)
    • /
    • v.35 no.3
    • /
    • pp.210-215
    • /
    • 2011
  • Rutin (R) exhibits a wide range of biological activities including anticarcinogenic, antiinflammatory and antiviral actions. The purpose of this study is to investigate the effect of rutin concentrations (1 and 3 wt%) on the antibacterial activity of poly(3-hydroxybutylate-co-hydroxyvalerate) (PHBV) scaffolds. Antibacterial activity was evaluated by using Staphylococcus aureus and Klebsiella pneumoniae. Furthermore, the qualitative ongrowth of human KB endothelial cells was done to study in vitro cytotoxicity of the scaffolds. As the results, PHBV scaffolds containing 3 wt% rutin completely inhibited the proliferation of Staphylococcus aureus and Klebsiella pneumoniae. In addition, the PHBV/R scaffolds used in this study did not show any cytotoxicity when evaluated them with KB endothelial cells.