• Title/Summary/Keyword: Co-fire

Search Result 935, Processing Time 0.023 seconds

A Numerical Study to Analyze Safety of Pressure Leakage Monitoring System of Gas Extinguishing Agent (가스소화약제 압력누기감시장치의 안전성 분석을 위한 수치적 연구)

  • Go, A-Ra;Lim, Dong-Oh;Son, Bong-Sei
    • Fire Science and Engineering
    • /
    • v.30 no.4
    • /
    • pp.103-110
    • /
    • 2016
  • While the demand for the gas system fire extinguishers increases every year, there are insufficient safety measures for assessing the extinguishing performance, such as system safety and reliability in the preparation of increasing demand, which has emerged as a social problem. One of the most critical causes of accidents occurring with the gas extinguishing system is pressure leakage from the extinguishing agent storage container. This is considered to be one of the critical factors on which the success of fire suppression depends. In this study, its safety measure was studied, Because it was deemed urgently necessary. The newly developed pressure leakage monitoring system is a system monitoring storage condition, pressure, leakage and discharge of the storage container related to agent concentration, which is one of the critical factors for fire suppression. This was developed to be applicable to the $CO_2$ and HFC-23 systems. Therefore, for structural safety analysis, the safety performance was verified by the fluid structure coupling analysis of the safety problems that may occur when the pressure leakage monitoring system is applied to the gas fire extinguisher. For analysis programs, the FloEFD program from Mentor Graphics was used for computational fluid dynamics analysis and ABAQUS from Dassault Systems was used for structural analysis. From the result of numerical analysis, the structure of $CO_2$ did not develop plastic deformation and its safety was verified. However, plastic deformation and deviation issue occurred with the HFC-23 monitoring system and therefore verified the structural safety of pressure leakage monitoring system by data obtained from redesigning and adjusting the condition of numerical interpretation three times.

A Study on Fire Spread between Office Room and Atrium in the Atrium Building

  • Lee, Su-Kyung;Kim, Jong-Hoon;Ko, Han-Mog
    • Proceedings of the Korea Institute of Fire Science and Engineering Conference
    • /
    • 1997.11a
    • /
    • pp.345-352
    • /
    • 1997
  • We could analyse the fire behavior using the developed software for fire safety assessment in a large space such as atrium. But Korean building law hasn't admitted the result of fire risk assessment in atrium. In the legislation fire resistant wall or shutter must be required between atrium and office rooms, That has obstructed development of building design and fire protection technique in Korea. From this point of view, we made scenarios of fire spread between atrium and office rooms, and then computed fire spread and fire phenomena using FASTLite and Breakl. In this study, we can decide that fire compartmentalization between atrium and office rooms doesn't require in Atrium building if the material and fire protection system were reliable. Consequently, Korean Fire Protection Regulations have to consider in direction of increasing freedom of building.

  • PDF

Estimation of non-CO2 Greenhouse Gases Emissions from Biomass Burning in the Samcheok Large-Fire Area Using Landsat TM Imagery (Landsat TM 영상자료를 활용한 삼척 대형산불 피해지의 비이산화탄소 온실가스 배출량 추정)

  • Won, Myoung-Soo;Koo, Kyo-Sang;Lee, Myung-Bo;Son, Yeong-Mo
    • Korean Journal of Agricultural and Forest Meteorology
    • /
    • v.10 no.1
    • /
    • pp.17-24
    • /
    • 2008
  • This study was performed to estimate non-$CO_2$ greenhouse gases (i.e., GHGs) emission from biomass burning at a local scale. Estimation of non-$CO_2$ GHGs emission was conducted using Landsat TM satellite imagery in order to assess the damage degree in burnt area and its effect on non-$CO_2$ GHGs emission. This approach of estimation was based on the protocol of the 2003 IPCC Guidelines. In this study, we used one of the most severe fire cases occurred Samcheock in April, 2004. Landsat TM satellite imageries of pre- and post-fire were used 1) to calculate delta normalized burn ratio (dNBR) for analyzing burnt area and burn severity of the Samcheok large-fire and 2) to quantify non-$CO_2$ GHGs emission from different size of the burnt area and the damage degree. The analysis of dNBR of the Samcheok large-fire indicated that the total burnt area was 16,200ha and the size of the burnt area differed with the burn severity: out of the total burnt area, the burn severities of Low (dNBR < 152), Moderate (dNBR = 153-190), and High (dNBR = 191-255) were 35%, 33%, and 32%, respectively. It was estimated that the burnt areas of coniferous forest, deciduous forest, and mixed forest were about 11,506ha (77%), 453ha (3%), and 2,978ha (20%), respectively. The magnitude of non-$CO_2$ GHGs emissions from the Samcheok large-fire differed significantly, showing 93% of CO (44.100Gg), 6.4% of CH4 (3.053Gg), 0.5% of $NO_x$ (0.238Gg), and 0.1% of $N_2O$ (0.038Gg). Although there were little changes in the total burnt area by the burn severity, there were differences in the emission of non-$CO_2$ GHGs with the degree of the burn severity. The maximum emission of non-$CO_2$ GHGs occurred in moderate burn severity, indicating 47% of the total emission.

Characterization of Secondary Exposure to Chemicals and Indoor Air Quality in Fire Station (소방서 실내공간의 화학적 유해인자 2차노출과 실내공기질 특성)

  • Kim, Soo Jin;Ham, Seunghon;Jeon, Jeong Seok;Kim, Won
    • Fire Science and Engineering
    • /
    • v.33 no.4
    • /
    • pp.140-151
    • /
    • 2019
  • It is to assess the indoor air quality of the chemical hazardous materials exposed to the fire after firefighters returned to the fire scene. The research subject randomly selected four fire stations located in Seoul, Korea. Two fire stations were set up as control groups after the return of the firefighting activities at the actual fire scene, and two other fire stations were set up as control groups to measure the air quality of the room at normal levels regardless of the action. We conducted 24-hour monitoring for all fire accidents that occurred in Seoul Metropolitan using fire safety map computer system. Also, indoor air quality was measured immediately after homecoming if the experiment group was to be dispatched due to an accident of intermediate or larger scale. 11 hazardous substance items such as fine dust, formaldehyde, volatile organic compounds, PAH, VCM, acidity, asbestos, CO2, NO2, O3 were measured according to the process test method. Three of 11 types of harmful substances exceeded domestic and foreign standards, and one of them was found to be close to foreign standards. In particular, total volatile organic compounds, carbon dioxide and sulfuric acids were 2.5 times, 2.2 times and 1.1 times higher than the standard. Also, for formaldehyde and sulfuric acid, it was measured higher in the control group than in the case group. This findings could be used in policies to improve indoor air quality in the fire station of the Seoul Metropolitan Government.

Motive for the Fire Resistance Design Guidelines for High-Strength Concrete Structures (고강도콘크리트 구조내화설계 지침의 제정 배경 및 고찰)

  • Kwon, Young-Jin;Lee, Jae-Young;Shin, Yi-Chul;Seo, Dong-Gu;Han, Byung-Chan;Kim, Jae-Hwan
    • Proceedings of the Korea Institute of Fire Science and Engineering Conference
    • /
    • 2007.11a
    • /
    • pp.3-8
    • /
    • 2007
  • 초고층건축물이 증가함에 따라 고강도콘크리트의 사용량이 증가하는 추세이다. 고강도콘크리트는 내구성 및 사용성이 우수한 장점을 가지고 있는 반면 화재시 심각한 폭렬현상을 발생시켜 콘크리트 내역 감소 및 철근의 노출로 인해 건물이 붕괴까지 이르게 되는 원인이 된다. 따라서 고강도콘크리트의 내화특성을 고려한 해석(열응력, 질량 이동, 폭렬) 과정을 거쳐 폭렬 저감방안을 모색하여야 한다. 이러한 폭렬 저감방안을 표층부의 온도상승 온도구배 저감 방안, 수중기압 저감/수분 이동을 용이하게 하는 방안, 폭렬억제형 피복콘크리트 이용방안, 폭렬에 의한 콘크리트의 비산을 방지하는 방안 등이 있으며 각 방안들은 장단점을 내포하고 있어 상황에 따라 탄력적으로 적용하여야 하며, 향후 고강도 콘크리트의 역학적 성상을 고려하여 단점을 보완하고 추가적인 대책용 수립할 수 있도록 많은 연구가 필요 할 것으로 판단된다.

  • PDF

An Experimental Study on the Development of Fire-retardant Treated Wood for Construction (건축용 난연 목재 개발에 대한 실험 연구)

  • Seo, Hyun Jeong;Kim, Nam Kyun;Jo, Jeong Min;Lee, Min Chul
    • Journal of the Korean Society of Safety
    • /
    • v.32 no.5
    • /
    • pp.149-156
    • /
    • 2017
  • This study investigates fire-retardant performances and combustion/thermal characteristics of fire-retardant treated wood by comparing them with those of fire-retardant untreated wood from the expreimental resutls of cone calorimeter and thermo-gravimetric(TG) analyzer. Hazardousness of combustion product gases for fire-retardant treated wood and untreasted wood were also observed from the results of internal finish material incombustibility test according to the Korea standard code of KS F 2271. In this study, we also tried to improve the fire retardant performance of wood by applying fire-retardant chemical composites, and to secure the fire safety performance in buildings. Red pine (Pinus densiflora) was selected as a test specimen because it is mostly used as a building material in Korea. Fire retardant chemical composites (FRCs) were prepared by mixing boron, phosphorous, and nitrogen species and treated by press-impregnation method. Water-based FRCs were composed of 3% boric acid($H_3BO_3$), 3% borax decahydrate($Na_2B_4O_7$), 8% ammonium carbonate($(NH_4)_2CO_3$), diammonium phosphate ($(NH_4)_2HPO_4$) varied from 10-30% and potassium carbonate($K_2CO_3$) varied from 10-30%. From the test results of cone calorimeter, TG analysis and gas hazard assessments, newly proposed were the optimal composition and production methods of FRCs which can sufficiently meet fire-retardant level 3 based on Korea law of construction. Thus, the FRCs, developed in this study, are anticipated to contribute to the improvement of fire safety and widespread of usage in wood as building materials.

New Input Keyword Extraction of Equipments Involved in Ignition Using Morphological Analysis (형태소 분석을 이용한 발화관련 기기의 새로운 입력 키워드 추출)

  • Kim, Eun Ju;Choi, Jeung Woo;Ryu, Joung Woo
    • Fire Science and Engineering
    • /
    • v.28 no.2
    • /
    • pp.91-97
    • /
    • 2014
  • New types of fire accidents appear or the existing types disappeared because of rapidly changing society. We proposed a methodology of extracting new nouns from fire investigation data each of which is an accident report producted by fire investigators. The new nouns could be used in modifying the existing categories for classifying fire accidents. We analysed morphology of the product names and the ignition summaries using the proposed method for the fire accidents classified as the etc sub-category of the category of equipments involved in ignition. In this paper, we found "dryer" as a new sub-category of the agricultural equipment category and "boiler" in the seasonal appliance category from the product names of the fire accidents. We also extracted the new input keywords of "aquarium" and "monitor" in the commercial facilities category and the video, audio apparatus category from the ignition summaries respectively. Using the four subcategories, we reclassified 548 (14.39%) of 3,808 fire accidents assigned to the etc sub-category.

Study on Post-Fire Safe Shutdown Analysis using an Imaginary Plant for Training (교육용 가상원전을 이용한 화재안전정지분석에 관한 연구)

  • Lee, Jaiho;Kim, Jin Hong
    • Fire Science and Engineering
    • /
    • v.32 no.1
    • /
    • pp.57-65
    • /
    • 2018
  • In this study, a post-fire safe shutdown analysis (PFSSA) including multiple spurious operation (MSO) treatments for cables was conducted with an imaginary nuclear power plant for training using a deterministic fire analysis code. The imaginary nuclear power plant for the training consisted of a reactor containment building and an auxiliary building, including a total of 22 fire areas. The equipment including valves, pumps, emergency diesel generators, switch gears, motor control centers, and logic controllers were located in each fire area of the imaginary plant. It was assumed that each equipment is connected with two cables and that each cable passes through the fire areas along the cable trays. A database containing the information on the equipment and cables for the imaginary plant was constructed for the fire area analysis. The fire area analysis was performed for several assumed MSO scenarios, equipment logics, and cable logics. A mitigation measure using a three hour rated wrap was applied to the failed cables and cable trays after the fire area analysis.