• Title/Summary/Keyword: Co-contamination

Search Result 447, Processing Time 0.028 seconds

The Analysis of Pressure Relief Technology for ZnO Arrester (ZnO 피뢰기의 Pressure relief 기술 분석)

  • Kim, I.S.;Han, S.W.;Cho, H.G.;Yoo, H.Y.;Kim, H.S.;Park, S.Y.
    • Proceedings of the KIEE Conference
    • /
    • 1998.07d
    • /
    • pp.1450-1452
    • /
    • 1998
  • The chief advantage of polymer arrester, from a handling viewpoint, design of pressure relief, anti-contamination, electrical failuer was reduced by polymer arrester. The life expectancy of polymer arrester depend on a number of design factor. This paper introduced and study : new material housing (silicone composite, EPDM, EPA...), cap type sealing structure, knuckle type electrode, stress relief housing, supporting insulator and sub parts, of polymer arrester.

  • PDF

Advanced Nickel Electroforming Technology for The Regenerative Thrust Chamber of the Rocket Engine

  • Sakaguchi, Hiroyuki;Makino, Takashi;Ishibashi, Toshiyuki
    • Proceedings of the Korean Society of Propulsion Engineers Conference
    • /
    • 2008.03a
    • /
    • pp.427-430
    • /
    • 2008
  • Electroforming is one of the key technologies for the regenerative thrust chamber of the rocket engine. To use nickel electroforming method for the thrust chamber, direct electroforming of nickel on cupper and the welding method between different materials are needed. Minimizing the internal stress is one of the important factor for making thick electroforming,. Also minimizing contamination(ex. Sulfur containing compound) is another important factor for the stability of quality. This paper includes advanced methods for thick nickel electroforming, those of strength test results and EDS/EPMA inspection results. Advanced for electroforming process makes the achievement of Electro-beam welding between Inconel718(Manifold) and Nickel Electroforming. This paper also includes the influence of the electroforming precipitation angle on strength. Thus advanced electroforming improvement processes and the test results make achievement for manufacturing of the regenerative thrust chamber with direct nickel thick electroforming on cupper materials.

  • PDF

Synthesis of TiC/Co Composite Powder by the Spray Thermal Conversion of Metallic Salt Solution (금속염용액의 분무열분해에 의한 TiC/Co복합분말 제조)

  • 이길근;문창민;김병기
    • Journal of Powder Materials
    • /
    • v.10 no.4
    • /
    • pp.228-234
    • /
    • 2003
  • In the present study, the focus is on the synthesis of titanium carbide/cobalt composite powder by the spray thermal conversion process using metallic salt solution as the raw materials. Two types of oxide powders of Ti-Co-O system were prepared by the spray drying of two types of metallic salt solutions : titanium chloride-cobalt nitrate and $TiO_2$ powder-cobalt nitrate solutions. These oxide powders were mixed with carbon black, and then these mixtures were carbothermal reduced under a flowing argon atmosphere. The changes in the phase structure and thermal gravity of the mixtures during carbothermal reduction were analysed using XRD and TG-DTA. In the case of using the titanium chloride-cobalt nitrate solution, it could not be obtained TiC/Co composite powder due to contamination of the impurities during the spray drying of the solution. However, in tile case of using the $TiO_2$ powder-cobalt nitrate scullion, TiC-15 wt. %Co composite powder could be synthesized by the spray thermal conversion process. The synthesized TiC-15 wt. %Co composite powder at 120$0^{\circ}C$ for 2 hours has average particle size of 150 nm.

Highly Conformal Deposition of Pure Co Films by MOCVD Using Co2(CO)8 as a Precursor (Co2(CO)8 (Dicobalt Octacarbonyl) 전구체를 이용한 MOCVD Co 박막의 균일한 증착 특성 및 높은 순도에 관한 연구)

  • Lee, Jeong-Gil;Lee, Jae-Gab
    • Korean Journal of Materials Research
    • /
    • v.16 no.2
    • /
    • pp.106-110
    • /
    • 2006
  • We have investigated the effect of the experimental variables such as temperature and pressure on conformality of Co films deposited over high aspect ratio trenches using $Co_2(CO)_8$ as a precursor. The results show that the conformality of Co films is a strong function of temperature and process pressure. Lowering the pressure and temperature significantly improves the conformality. As the pressure decreases from 0.6 Torr to 0.2 Torr at $50^{\circ}C$, the bottom coverage of Co films over $0.2{\mu}m$ width trenches with an aspect ratio of 13 to 1 significantly increases to 85%. However, further increasing the temperature from 50 to $60^{\circ}C$ at the pressure of 0.2 Torr degrades the bottom coverage to 14%. In contrast, the extremely low pressure of 0.03 Torr allows the excellent conformal deposition of Co films up to $70^{\circ}C$. This can be attributed to the suppression of homogeneous reaction in the gas phase, which can create the intermediate products with high sticking coefficient. In addition, the Co films deposited at $50^{\circ}C$ show the low resistivity with negligible contamination. As a result, the newly developed Co process using MOCVD can be implemented into the next generation devices with complex shapes.

Comparative Study on Energy Consumption in Steam-Humidification- and Water-Spray-Humidification-Type Outdoor Air-Conditioning Systems for Semiconductor Manufacturing Clean Rooms (반도체 클린룸용 증기가습 및 수분무가습 외기공조시스템의 에너지소비량 비교연구)

  • Kim, Hyung-Tae;Song, Gen-Soo;Kim, Ki-Cheol;Yoo, Kyung-Hoon;Son, Seung-Woo;Shin, Dae-Kun;Park, Dug-Jun;Kwon, Oh-Myung
    • Transactions of the Korean Society of Mechanical Engineers B
    • /
    • v.35 no.12
    • /
    • pp.1249-1255
    • /
    • 2011
  • In modern large-scale semiconductor manufacturing clean rooms, the energy consumed by the outdoor air-conditioning system during heating, humidification, cooling, and dehumidification of the incoming outdoor air represents about 45% of the total air-conditioning load required to maintain a clean-room environment. In particular, the energy required for humidification of the outdoor air in winter is very high. Therefore, evaluation and comparison of the energy consumption in key humidification systems, viz., steam-humidification and water-spray-humidification systems, used in outdoor air-conditioning systems would be useful to reduce the outdoor air-conditioning load in clean rooms. In the present study, an experiment with an outdoor air flow of 1000 $m^3$/h was conducted to compare the air-conditioning process and energy consumption in outdoor air-conditioning systems with electrodeboiler steam humidifiers and air-washer water spray humidification systems. The experimental results showed that the water-spray-humidification-type outdoor air-conditioning system consumed less electrical power than did the steam-humidification-type system and was more energy efficient during winter.

Characteristics of Groundwater Quality in a Riverbank Filtration Area (강변여과수 부지 내 충적층 지하수의 수질특성과 변화)

  • Hyun Seung-Gyu;Woo Nam-C.;Shin Woo-Sik;Hamm Se-Yeong
    • Economic and Environmental Geology
    • /
    • v.39 no.2 s.177
    • /
    • pp.151-162
    • /
    • 2006
  • Characteristics and changes of groundwater qualify were investigated in a riverbank filtration area at Daesan-myeon, Changwon City, Korea. The total dissolved solids (TDS) in groundwater samples collected in October were much less than that in March, indicating the mixing with recharged water from precipitation, as well as the changes of dissolved oxygen profiles at monitoring wells from March to October. Redox processes at depths appeared to trigger Fe and Mn contamination of groundwater in riverbank deposits. Amorphous oxyhydroxides md carbonate minerals such as $MnCO_3$ were probably the reactive phases for dissolved Fe and Mn, respectively. Groundwater contamination by nitrate-nitrogen $(NO_3-N)$ was controlled by the redox processes and subsequent denitrification at the sampled depths. Distribution of $NO_3-N$ concentrations at monitoring wells suggested that the nitrate contaminants were originated from agricultural facilities on the riverbank deposits. Some of monitoring wells, DS-2, D-2, DS-3, SJ-1, and SJ-3, were only partially penetrated into the sand/gravel aquifer, and subsequently, could not fully function to detect the water quality changes for the pumping wells. Proper measures, with regulating agricultural activities in the riverbank deposits, should be carried out to prevent groundwater contamination of the riverbank filtration area.

Development of Horizontal Boring Equipment for Radial Collector Wells (방사형 집수정을 위한 수평천공장치 개발)

  • Park, Geun-Wu;Jeong, Gyeong-Hwan;Lee, Chung-Hun;Kwon, June-Yong;Kim, Jae-Hwan
    • Proceedings of the Korean Geotechical Society Conference
    • /
    • 2008.03a
    • /
    • pp.905-913
    • /
    • 2008
  • The water resource depending on mostly surface water has many problems, such as contaminated and unpredicted contamination event. For this reason, it has been employed highly technical treatment method for them, such as ground water dam and river bank filtration. it has been developed the radial collector wells in kind of bank filtration to increase efficiency for in-taking the water resource insead of the vertical well needed many wells to take more resource. But it has many problems with the incumbent method to bore the horizontal hole for radial collector wells, such as filling with the filter material outside of a strainer by watering, jamming as retrieving the casing tube with the filter material, eccentric boring etc. To reduce the problems of incumbent equipment, it has been developed the horizontal boring equipment and performed the field trial tests several times, which have bits and water jetting system with rotating the cone-shaped front to be excavated easily. In this paper, it was compared the brand-new with the incumbent non-rotating pressing insertion method. Also it was shown the problems of the incumbent method was reduced effectively.

  • PDF

The Study of Crude Oil Contaminated Soil Remediation by Indirect Thermal Desorption (간접열탈착방식을 이용한 원유오염토양 정화효율 평가)

  • Lee, In;Kim, Jong-Sung;Jung, Tae-Yang;Oh, Seung-Taek;Kim, Guk-Jin
    • Journal of Soil and Groundwater Environment
    • /
    • v.21 no.3
    • /
    • pp.14-20
    • /
    • 2016
  • Remediation of crude oil contaminated soil is complicate and hard to apply traditional methods because of its persistency, durability, and high viscosity. Therefore, in this study, the efficiency of crude oil contaminated soil remediation was tested by developing a pilot-scale thermal desorption system using the indirect heating method with an exhaust gas treatment. Under optimal condition drawed by temperature and retention time, the remedial efficiency of crude oil contaminated soil and treatability of exhaust gas were analyzed. Total Petroleum Hydrocarbon (TPH) concentration of crude oil contaminated soil was decreased to 69.7 mg/kg on average and the remedial efficiency was measured at 99.60%. Through the exhaust gas, 86.0% of Volatile Organic Compounds (VOC) was degraded and 97.16% of complex malodor was reduced under the suggested optimum operation condition. This study provides important basic data to be useful in scaling up of the indirect thermal desorption system for the remediation of crude oil contaminated soil.

Assessment of Contamination and Geochemical Dispersion by Heavy Metals in Roadside Tree Leaves of Platanus occidentalis and Soils in the City of Seoul (서울시 가로수목 중 플라타너스 잎과 토양의 중금속 원소에 대한 지구화학적 분산과 오염평가)

  • Choo, Mi Kyung;Lee, Jin-Soo;Lee, Jeonghoon;Kim, Kyu-Han
    • Economic and Environmental Geology
    • /
    • v.47 no.4
    • /
    • pp.405-420
    • /
    • 2014
  • To investigate geochemical characteristics of soil and atmospheric environments by anthropogenic source, we have analyzed and determined heavy metal concentrations of the surface soils beneath roadside trees and leaves of Platanus occidentalis from 52 points in Seoul during autumn 2001. For comparison of the contents of heavy metal for the soil and leaf, we have analyzed heavy metal contents of the surface soils beneath roadside trees and leaves from 2 points in rural area of Yesan during the same time period. The composition of heavy metals of soils are relatively high for Cd, Co, Cr and Ni in industrial area (IA, Industrial Area) and high for Cu, Pb and Zn in heavy traffic area (HTA, Heavy Traffic Area). The heavy metal contents of rural area in Seoul are higher than those in Yesan. The differences of chemical compositions between the washed and unwashed leaves are high for Cd, Cu, Pb and Zn in the HTA. The element couples of Cd-Co, Cr-Ni and Pb-Zn for the soils had shown a good correlation and their contamination sources could be similar. The relationship for Pb-Cu and Cu-Zn showed good correlation in Platanus leaves. The relationship between soils and unwashed leaves show a good correlation for Cr, Cu, Pb and Zn but low correlation for Cd, Co, Fe, Mn and Ni. It is thought that the Cr, Cu, Pb and Zn were derived from contaminants of soils, whereas Cd, Co, Fe, Mn and Ni were originated from atmospheric source. From the spatial variations of elements for soils and leaves, Ni and Cr were dominant in the soils of IA and Cd, Cu and Zn were dominant in those of HTA. The Contamination by Cd-Pb and Cu-Zn in unwashed leaves were analyzed to show similar patterns. Using the enrichment factors (EF) of heavy metals in unwashed leaves, the EF sequences were to be Cu, Zn, Pb, Mn, Co, Ni, Cd and Cr. We identified that Cu, Zn, Pb and Mn were most problematic of environmental hazard in Seoul.

An Experimental Study on Internal Decontamination Radiocobalt (Radiocobalt의 체내 오염(汚染)에 대(對)한 제염효과(除染效果))

  • Chung, In-Yong;Kim, Tae-Hwan;Chung, Hyun-Woo;Chin, Soo-Yil;Yun, Taik-Koo
    • Journal of Radiation Protection and Research
    • /
    • v.13 no.1
    • /
    • pp.31-41
    • /
    • 1988
  • In case of the acute intake of radionuclide, an early medical treatment may be necessary, but the little is established the procedures to decontaminate the victims of internal contamination in Korea. The purpose of the present investigation is to study chemical agents to remove radiocobalt from the victims and to provide a more reliable procedure for the treatment. The removals of radiocobalt from the NIH-CGP)mice injected intraperitoneally with $1{\mu}Ci$ of $^{58}Co$ as $CoCl_2$ were investigated with doses of either $CaNa_3$ DTPA 8.4mg/0.2ml saline, $CoNa_3$ DTPA 8.4mg/0.2ml saline, or saline 5ml. The radioactivity was determined by MCA and Ge-detector on 4, 8, 12, 48 hours and 7 days for the whole body, organ distribution and urine excretion. Six mice per each group were sacrificed for the measurement of cobalt retention in the parenchymal tissue. The cobalt trisodium chelate had a pronounced effect on reducing the whole body retention and increasing the excretion rate. Regarding to the systemic protective effects, $CoNa_3$ DTPA, $CaNa_3$ DTPA and saline were effected significantly in order. In conclusion, the extrapolations from these results to human were suggested that the rapid administration of cobalt trisodium chelate and an amount of saline to the contaminated person after internal contamination of radiocobalt were markedly increasing the decontamination effects.

  • PDF