• Title/Summary/Keyword: Co-contaminants

Search Result 200, Processing Time 0.022 seconds

Study on a Small-scale Wastewater Treatment System using Biological Aerated Filter (생물학적 호기성필터를 이용한 소규모 하수처리시스템에 관한 연구)

  • Park, Chan G.;Jo, Eun Y.;Kim, Young H.;Park, Sung J.
    • The KSFM Journal of Fluid Machinery
    • /
    • v.17 no.3
    • /
    • pp.41-45
    • /
    • 2014
  • The biological aerated filter (BAF) reactor is regarded as an effective biological wastewater treatment method. It can remove pollutants by carrier filtration and biodegradation. Due to its advantages, which include high biomass retention, tolerance to toxicity, excellent removal efficiency, and slurry separation, BAF has been widely used to remove COD, $NH_4{^+}-N$, phosphorus, and other harmful organic substances. In this study, the BAF reactor was used to remove organic contaminants of domestic wastewater of Korea at both the benchand pilot-scale. The main objectives of this study are to: (i) investigate the removal efficiency of organic contaminants (ex. COD, nitrate, phosphorus) in BAF reactors at both scales; (ii) characterize the small-scale wastewater treatment plant using the BAF reactor. The concentration of COD in the influent increased from 69 to 246 mg/L. During the operation period, the final effluent concentration of COD remained maximum 4.0 mg/L, and the average removal efficiency was above 88%. The present study investigated the removal efficiencies of COD, TN, TP and $NH_4{^+}-N$ from smelting wastewater by BAF system. When treating wastewater in both bench and pilot-scale reactors, the BAF worked well.

Combined Effect of 2,4,6-trinitrotoluene(TNT) and Cadmium on Uptake and Phytotransformation of TNT by Abutilion avicennae (TNT(2,4,6-trinitrotoluene)와 카드물의 복합오염이 어저귀의 TNT 흡수 및 생물학적 전환에 미치는 영향)

  • 이인숙;김선영;배범한;장윤영
    • The Korean Journal of Ecology
    • /
    • v.25 no.2
    • /
    • pp.69-74
    • /
    • 2002
  • Most of army depots contaminated with co-contaminants. 2,4,6-trinitrotoluene(TNT) and heavy metais. In phytormediation for the TNT, heavy metals may inhibit mineralization, transformation and sequestration of TNT by the plant. W studied effect of cadmium on TNT degradation and transformation by Abutilion avicenneae in hydroponic cultures. When cultured in 20 ㎎TNT/L and 1.3 ㎎Cd/L. the plant displayed phytotoxicities; reduction of leaf fresh, leaf roll, chlorosis, leaf loss and fresh weight loss. Phytotoxicity was severer in the combined contaminnts than in single contaminant. Because A. avicennae uptake just a little cadmium, 1.3 ㎎Cd/L induded in the TNT medium did not influece significanfly TNT transformation, translocation and distrivution by A. Therefore, the soil solution containing cadmium would not affect TNT degradation by Abutilion avicennae in Amy depots polluted with TNT.

Evaluation of Cleaning Efficiency of Reverse Osmosis Module Using Micro-bubble (미세기포를 이용한 역삼투 모듈 세정 효율 평가)

  • Kim, Dongjin;Kang, Shingyung;Cho, Hayoung;Lee, Jeawoo;Moon, Ilshik
    • Membrane Journal
    • /
    • v.27 no.1
    • /
    • pp.104-107
    • /
    • 2017
  • Among many methods in solving the organic contamination in the reverse osmosis operation, caustic soda (NaOH) wash method is efficient and commercially affordable. In continuation of our many organic pollution removal works, this study focused mainly on caustic soda wash with micro-bubble to removal the organic contamination of the spent membrane from reverse osmosis process. First, the membrane was forced the pollute using known organic pollutants such as Humic acid, Bovine serum albumin, Sodium alginate drug. The organic contamination on the membrane was monitored flux. The decontamination of organic contaminants was derived flux variation at individual caustic soda was injected micro-bubble methods and combined method as well. the found results explain removal of organic contaminants effective only by combined caustic soda wash with micro-bubble methods.

Method for contaminant removal from leachate induced by buried livestock carcasses (매몰 사축에 의한 침출수내 오염물질 제거 방법)

  • Haeseong Jeon;Joonkyu Park;Geonha Kim
    • Journal of Korean Society of Water and Wastewater
    • /
    • v.37 no.6
    • /
    • pp.395-408
    • /
    • 2023
  • This study presents a novel method for addressing the issue of high-concentration contaminants (ammonium, phosphate, antibiotics) in leachate arising from decomposing livestock carcasses. Antibiotics, developed to eliminate microorganisms, often have low biodegradability and can persist in the ecosystem. This research proposes design elements to prevent contamination spread from carcass burial sites. The adsorbents used were low-grade charcoal (an industrial by-product), Alum-based Adsorbent (ABA), and Zeolite, a natural substance. These effectively removed the main leachate contaminants: low-grade charcoal for antibiotics (initial concentration 1.05 mg/L, removal rate 73.4%), ABA for phosphate (initial concentration 2.53 mg/L, removal rate 99.9%), and zeolite for ammonium (initial concentration 38.92 mg/L, removal rate 100.0%). The optimal mix ratio for purifying leachate is 1:1:10 of low-grade charcoal, ABA, and zeolite. The average adsorbent usage per burial site was 1,800 kg, costing KRW 2,000,000 per ton. The cost for the minimum leachate volume (about 12.4 m3) per site is KRW 2,880,000, and for the maximum volume (about 19.7 m3) is KRW 4,620,000. These findings contribute to resolving issues related to livestock carcass burial sites and suggest post-management strategies by advocating for the effective use of adsorbents in leachate purification.

Feasibility Study of Microturbine CHP and Greenhouse $CO_2$ Enrichment System as Small Scale LFG Energy Project (소규모 매립가스 자원화를 위한 마이크로터빈 열병합발전 및 유리온실 $CO_2$ 농도 증가 시스템의 타당성 연구)

  • Park, Jung-Keuk;Hur, Kwang-Beom;Rhim, Sang-Gyu;Lee, In-Hwa
    • New & Renewable Energy
    • /
    • v.5 no.2
    • /
    • pp.15-24
    • /
    • 2009
  • As new small scale LFG (landfill gas) energy project model which can improve economic feasibility limited due to the economy of scale, LFG-Microturbine combined heat and power system with $CO_2$ fertilization into greenhouses was proposed and investigated including basic design process prior to the system installation at Gwang-ju metro sanitary landfill. The system features $CH_4$ enrichment for stable microturbine operation, reduction of compressor power consumption and low CO emission, and $CO_2$ supplement into greenhouse for enhancement plant growth. From many other researches, high $CO_2$ concentration was found to enhance $CO_2$ assimilation (also known as photosynthesis reaction) which converts $CO_2$ and $H_2O$ to sugar using light energy. For small scale landfills which produce LFG under $3\;m^3$/min, among currently available prime movers, microturbine is the most suitable power generation system and its low electric efficiency can be improved with heat recovery. Besides, since its exhaust gas contains very low level of harmful contaminants to plant growth such as NOx, CO and SOx, microturbine exhaust gas is a suitable and economically advantageous $CO_2$ source for $CO_2$ fertilization in greenhouse. The LFG-Microturbine combined heat and power generation system with $CO_2$ fertilization into greenhouse gas to enhance plant growth is technologically and economically feasible and improves economical feasibility compared to other small scale LFG energy project model.

  • PDF

Characterization of landfarming for bioremediation of petroleum-contaminated soil in Korea (유류오염토양의 생물학적 복원을 위한 국내 토양경작기술의 적용 특성)

  • Lee Kwang-Pyo;Lee Cheol-Hyo
    • 한국생물공학회:학술대회논문집
    • /
    • 2004.07a
    • /
    • pp.107-125
    • /
    • 2004
  • A bioremediation of petroleum-contaminated soil in Korea was evaluated for the optimization of enhanced biodegradation and the minimization of effects of seasonal variations, The short-term bioremediation in combination of biopile pretreatment and landfarming was performed by lowering contaminated levels and overcoming the inhibiting factors in the rainy and winter seasons. A microbial density was maintained with indigenous microbial addition for bioaugmentation and with fertilizers for biostimulation. A lesser volatile and biodegradable fraction due to their abiotic removals following the biopile pretreatment was effectively removed by the laterally applied landfarming. The optimal temperature in greenhouse was maintained by buffering of the soil temperature even with slight decreases in removal rates during the winter and extensive leaching of nutrients and contaminants was restricted with adjusting the water contents during the Korean rainy season. Although the tilling process was effective for biodegradation with aeration only, the simultaneous treatment due to apparent mixing of nutrients and microbes more favorably degraded the petroleum than the sequential treatment.

  • PDF

다중이용시설의 실내공기질 실태조사 연구

  • 이윤규
    • The Magazine of the Society of Air-Conditioning and Refrigerating Engineers of Korea
    • /
    • v.33 no.6
    • /
    • pp.24-31
    • /
    • 2004
  • 국내의 경우, 2004년 5월부터 시행예정인 다중이용시설 등의 실내공기질관리법에 따라서, 학교 등의 일부 건축물을 제외하고 신축공동주택 및 대부분의 거주용 공간에 대한 실내공기질관리법이 제정되었다. 이러한, 건축물 내에는 다양한 오염원(sources)과 휘발성유기화합물(VOCs), 포름알데히드(HCHO), 라돈(Radon), 석면(Asbestos), 일산화탄소(CO), 이산화탄소($CO_2$), 이산화질소(NO$_2$), 오존(O$_3$), 미세 먼지(PM10), 부유세균 등 유해오염물질(contaminants)이 존재하고 있다. 또한, 실내공기오염은 각 오염원에서의 유해오염물질 방산정도(emission rate)가 실내외 환경조건, 적용 건축자재의 종류 및 공법 , 환기설비의 특성 및 유형 등에 따라 큰 차이를 보이고 있으므로, 이에 대한 정확한 측정방법의 정립과 그에 따른 적절한 실태조사의 실시가 필요하다. (중략)

  • PDF

Investigation of the Characteristics of Lubricant in Computer Hard Disk by Using Surface Analysis Technique (표면 분석을 이용한 컴퓨터 하드디스크용 윤활제의 특성 연구)

  • 조남철;남인탁
    • Journal of the Korean Magnetics Society
    • /
    • v.9 no.5
    • /
    • pp.263-270
    • /
    • 1999
  • The characteristics of lubricant for computer hard disk was investigated by surface analysis technique. The bonding state between carbon and lubricant is analysed to indentify the origin of adhesion. It is found that the thickness of lubricant is increased as pulling-up speed becomes faster and lubricant concentration is increased. The dominant surface contaminants on carbon overcoat are identified with C-OH and CO. The bond strength between carbon and lubricant is enhanced with heat treatment.

  • PDF

Evaluation of Particle Removal Efficiency during Jet Spray and Megasonic Cleaning for Aluminum Coated Wafers

  • Choi, Hoomi;Min, Jaewon;Kulkarni, Atul;Ahn, Youngki;Kim, Taesung
    • Journal of the Semiconductor & Display Technology
    • /
    • v.11 no.3
    • /
    • pp.7-11
    • /
    • 2012
  • Among various wet cleaning methods, megasonic and jet spray gained their popularity in single wafer cleaning process for the efficient removal of particulate contaminants from the wafer surface. In the present study, we evaluated these two cleaning methods for particle removal efficiency (PRE) and pattern damage on the aluminum layered wafer surface. Also the effect of $CO_2$ dissolved water in jet spray cleaning is assessed by measuring PRE. It is observed that the jet spray cleaning process is more effective in terms of PRE and pattern damage compared to megasonic cleaning and the mixing of $CO_2$ in the water during jet sprays further increases the PRE. We believe that the outcome of the present study is useful for the semiconductor cleaning process engineers and researchers.

The Use of Demand Controlled Ventilation in Multi-Purposed Facility (수요기반 환기량 조절법 (DCV)의 다중이용시설 적용방안)

  • Jeong, Jae-Weon;No, Sang-Tae
    • 한국태양에너지학회:학술대회논문집
    • /
    • 2008.04a
    • /
    • pp.111-116
    • /
    • 2008
  • The objective of this paper was to show the possibility of demand-controlled ventilation (DCV) using the current Korean ventilation standard for multi-purposed facilites. Two attractive DCV approaches; $CO_2$-DCV and RFID-DCV were applied to DCV simulations for a theoretical public assembly space served by a dedicated outdoor air system (DOAS) with enthalpy recovery device. A numerical model for predicting realtime occupant number, ventilation rate, and $CO_2$ concentration under given conditions was developed using a commercial equation solver program. It was found that the current ventilation standard causes unstable ventilation system control in DCV applications, especially under $CO_2$-DCV. It is because the ventilation rate (per person) used in Korea is the sum of the outdoor air required to remove or dilute air contaminants generated by both occupant and building itself, and not a pure function of occupant numbers. Finally, it makes DCV control unstable when ventilation flow is regulated only by the number of occupants. In order for solving this problem, current Korean ventilation standard was modified as a form of ASHRAE Standard 62.1-2007 showing good applicability to various DCV approaches. It was found that this modification enhances applicability of the current ventilation standard to DCV significantly.

  • PDF