• Title/Summary/Keyword: Co-Housing

Search Result 383, Processing Time 0.025 seconds

A Study on the preference and trends about co-housing of Senior citizen Who lives alone in Rural and Fishing Village - A study on the Model of Co-Housing for Senior citizen who lives alone in the rural and fishing village (I) - (농어촌 독거노인의 공동주거 선호 경향에 관한 연구 - 농어촌 독거노인을 위한 친환경 공동주거의 모형개발 연구(1) -)

  • Cho, Won-Seok;Kim, Heung-Gee
    • Journal of the Korean Institute of Rural Architecture
    • /
    • v.13 no.4
    • /
    • pp.107-114
    • /
    • 2011
  • According to the aging society, the housing environments of senior citizens who live alone are faced with social various problems. On the dwelling welfare, development of model for the silver house is necessary at the reducing of social expense. Particularly, the silver housing conditions of rural and fishing villages are poor than urban region. The results of this research are as follows. First, the senior citizens who live alone looked to an negative opinion about cohabitation of the aged, but the senior citizens who don't live alone and preliminary old man group showed a positive opinion to the regarding cohabitation. Second, Most of the aged was in poor health, On this account they expressed an opinion that they were opposite to the cohabitation opinion. Although considering health, simultaneous design of both private life and community life shall be reflected to the preferential design element in co-housing of the aged. Through these co-housing for the aged in rural and fishing village, the senior citizens who lives alone have prevented poor housing surroundings, loneliness, loss of role, uneasiness, gloomy, chronic disease.

A Comparative Analysis on Concentration of Pollutants in Housing Indoor-Air between Winter and Summer (주택 실내 공기중 오염물질 농도의 동절기와 하절기 비교 분석)

  • Nam, Ki-Cheul;Lee, Young-Han;Choi, Bong-Seok
    • KIEAE Journal
    • /
    • v.17 no.3
    • /
    • pp.125-131
    • /
    • 2017
  • Purpose: The study is to measure concentrations of indoor air pollutants in housing and to analyze the characteristics of pollutants in housing indoor-air between summer and winter comparatively. The research result could be used as data for public health through indoor air quality management of existing housing and more as a reference for new housing. Method: It was investigated 24 middle class housings of metropolitan area in winter which have been built for the past 30 years. Concentration of HCHO, TVOC was investigated in living room at morning and night and concentration of $CO_2$ was investigated in living room and master bedroom at morning and night. SKT100-X5 was used for concentration of HCHO, TVOC and ZGm053UK for concentration of $CO_2$. The characteristics of HCHO, TVOC, $CO_2$ concentration in winter were analyzed and then the concentrations in winter were analyzed the concentrations in summer being preceding research comparatively. Result: Average concentration of TVOC in winter was 2.7 times more than that of TVOC in summer, average concentration of HCHO in winter was about 2.0 times more than that of HCHO in summer. Average concentration of $CO_2$ in the morning at living room in winter was 1.3 times more than that of $CO_2$ in summer. Average concentration of $CO_2$ in the morning at master bedroom in winter was 1.1 times more than that of $CO_2$ in summer. Average concentration of TVOC was 1.31 times more than that of HCHO and standard deviation of that was 1.73 times higher. Average concentration of $CO_2$ was almost nearly close or over to 1,000ppm being criteria of the Ministry of Environment.

An Analysis on HCHO, TVOC, CO2 Concentration of Existing-Housing Indoor-Air in Summer (기존 주택의 하절기 실내 공기중 HCHO, TVOC, CO2 농도 실태 조사분석)

  • Nam, Ki-Cheul;Lee, Young-Han
    • KIEAE Journal
    • /
    • v.16 no.6
    • /
    • pp.115-122
    • /
    • 2016
  • Purpose: The study is to measure indoor air pollutants concentration of existing housing and to analyze the causes and assess in accordance with the government's criteria. The research result could be used as data for public health through indoor air quality management of existing housing and more as a reference for new housing. Method: It was investigated 24 middle class housings of metropolitan area in summer which have been built for the past 30 years. Concentration of HCHO, TVOC was investigated in living room at morning and night and concentration of $CO_2$ was investigated in living room and master bedroom at morning and night. SKT100-X5 was used for concentration of HCHO, TVOC and ZGm053UK for concentration of $CO_2$. Result: Average concentration of TVOC was 1.31 times more than that of HCHO and standard deviation of that was 1.73 times higher. Average concentration of $CO_2$ was almost nearly close to 1,000ppm being criteria of the Ministry of Environment.

An analysis of the Influencing Factors and Actual State of Indoor Air Quality in Semi-underground Multi-family Housing Units (다가구주택 반지하세대의 실내공기질 실태 및 영향요인 분석)

  • Choi, Yoon-Jung;Kim, Sun-Young;Kim, Ji-Young;Choe, Sol-Ji
    • Korean Journal of Human Ecology
    • /
    • v.20 no.5
    • /
    • pp.1075-1091
    • /
    • 2011
  • The purposes of this study were to investigate the actual state of indoor air quality in semi-underground multi-family housing units in early summer, to analyze the influencing factors, and to make suggestions for improvement. A series of field investigations were conducted in four target units between June 22, 2010, and June 28, 2010. The field investigations included measurements of indoor air quality as well as the observation of architectural characteristics and living conditions. In addition to the field investigation, on-site questionnaire surveys were administrated to residents in 90 units. The findings are summarized as follows: (1) The average $CO_2$ levels in each of the four units ranged from 759ppm to 1885ppm. $CO_2$ levels in three units exceeded the evaluation standard (1000ppm), and one unit was lower than the standard. This unit had smaller number of staying person and a large amount of ventilation than others; (2) the average CO levels in each unit were almost 0ppm, but 0.1~1.1 levels of CO were revealed at several times; (3) the average PM-10 levels ranged from $8{\mu}g/m^3$ to $40{\mu}g/m^3$, which distributes within the standard ($150{\mu}g/m^3$). The influencing factors of PM-10 levels were analyzed as inflow from outside, the use of a gas range, and the residents' activities; (4) therefore, it was evaluated to be necessary to improve ventilation for the indoor air quality of semi-underground housing in aspect of $CO_2$ levels.

Analysis of the Redemption Risk of Renters Using CoLTV (CoLTV 지표를 이용한 임대차주의 상환위험 분석)

  • Lee, Ta Ly;Song, Yon Ho;Hwang, Gwan Seok;Park, Chun Gyu
    • Korea Real Estate Review
    • /
    • v.28 no.1
    • /
    • pp.65-77
    • /
    • 2018
  • This paper analyzes the redemption risk of renters by estimating the LTV and CoLTV with finance market big data (individual credit information) and housing market big data (actual housing transaction data). The analysis showed that when using LTV, the redemption risk was higher in the case of the monthly renter than of the chonsei renter. On the other hand, when using CoLTV, the chonsei renter had a higher redemption risk than the monthly renter. This implies that there is a need to activate a guarantee system, such as risk management using the CoLTV index and the chonsei deposit return guarantee because it is possible for renters to experience losses on their chonsei deposits due to the higher redemption risk. Another implication is that the risk manager should consider the individual characteristics of renters because of the different effects of the redemption risk stemming from the characteristics of the rental contract and the personal characteristics of the renters. CoLTV was just a concept until this study calculated it using housing big data and actual housing transaction information. It helps identify the redemption risk through the characteristics of renters and their contracts.

A Study on the Problems and Improvements of Housing Management - Focused on the Worker's Opinions of Management - (공동주택관리상의 문제점과 개선방안에 관한 연구 - 위탁관리업 종사자의 의견조사를 중심으로 -)

  • Lee, Young-Ae;Kim, Jung-In
    • Journal of the Korean housing association
    • /
    • v.23 no.2
    • /
    • pp.79-87
    • /
    • 2012
  • The purpose of this study was to offer improvements, by deriving practical problems and suggesting ways to improve more realistic solutions in the multi-family housing management industry. This study is conducted in two ways. First, it was performed by reviewing related previous studies and clarifying major issues in the multi-family housing management. Second, it was performed by a questionnaire survey method, focused on the worker's opinions for that matters. The respondents work in an apartment in Seoul and the metropolitan area. A questionnaire distributed via e-mail, and then were collected. And questionnaire did not respond were excluded from the analysis. Finding were as follows -; first, it was possible to clarify four types regarding major issues in the multi-family housing management such as 'management system', 'housing management market conditions', 'management consciousness of resident', 'management performances'. Second, it was found that the competition was fierce in the same kind. And it was quite a high turnover rate of workers because of poor working conditions. Third, the most hard part was that the employee welfare was not good at work.

The Study on the Activation of Domestic Co-Housing Module Application (국내 공동주택 모듈러 적용 활성화에 관한 연구)

  • Kim, Chung-Hee;Shim, Un-Jun;Ahn, Yong-Sun
    • Proceedings of the Korean Institute of Building Construction Conference
    • /
    • 2013.11a
    • /
    • pp.141-142
    • /
    • 2013
  • The modular construction method have improved quality, reduction of defects, such as the reduction of air, a number of advantages. It is utilized composite, larger, in skyscraper building already abroad. The domestic, various studies have been conducted on technical matters taller, automation of production, such as process control, but is still inadequate circumstances. Therefore, in this study, is the purpose that you have presented activation measures to investigate and analyze the case of co-housing with a modular construction system of outside, and to make the co-housing of modular construction system of domestic.

  • PDF

Impact of Green Building Rating System on an Apartment Housing CO2 Emission using Multiple Regression Analysis (다중 회귀 분석을 이용한 친환경 건축물 인증제도가 공동주택 CO2 발생량에 미치는 영향 분석)

  • Jung, Jung-Hee;Ryu, Hyeok-Jun;Lee, Jong-Hun;Kim, Ju-Hyung;Kim, Jae-Jun
    • Proceedings of the Korean Institute of Building Construction Conference
    • /
    • 2013.05a
    • /
    • pp.111-112
    • /
    • 2013
  • Architecture has a large influence in the environment and human health. Therefore eco-friendly concept and sustainable development are important in Architectural field. This study aims to analyze impact of green building rating system on an apartment housing CO2 emission using multiple regression analysis. But in this result, green building rating system has no effect on CO2 emission. So, future study is required to analyze factors of green building rating system on the CO2 emission.

  • PDF

A Study on the Optimization of Photovoltaic System for the ZEB Certification in Detached Housing (단독 주택의 제로에너지건축물 인증을 위한 태양광시스템 최적화에 관한 연구)

  • Shin, Jee-Woong;Yun, Jae-Hyun;Ko, Jeong-Lim
    • Journal of the Korean Solar Energy Society
    • /
    • v.39 no.3
    • /
    • pp.1-7
    • /
    • 2019
  • As part of the government's energy policy, Zero Energy Building certification was launched on January of 2017. However, the three passive-housing rental housing projects are the only ZEB-certified detached housing since the certification's launch. The reason is that, in order for a detached housing to earn ZEB certification, it has to secure self-reliance in energy, and a photovoltaic system is the only viable renewable energy system. Therefore, conducting an analysis to optimize the photovoltaic system in an early design stage is strongly recommended. This study aimed to propose an optimal photovoltaic system design for a detached housing after analyzing through the ECO2 energy simulation of 44 cases, varying in a module type and efficiency, inclination and azimuth. As a result, 15 cases out of 44 cases were analyzed to satisfy ZEB evaluation criteria, and it is thought that these data could contribute greatly to the expansion of ZEB certification dissemination.

A Study on Quantity of CO2 Emission about Remodeling Cycle at High-rise Apartment housing (초고층 공동주택 세대내 개보수 주기에 따른 이산화탄소 배출량 연구)

  • Kim, Dayoo;Kang, Seungyi;Je, Haeseong
    • KIEAE Journal
    • /
    • v.10 no.3
    • /
    • pp.75-80
    • /
    • 2010
  • The goal of this study is to figure out the remodeling cycle at high-rise apartment housing and to analysis on quantity of $CO_2$ emission about remodeling cycle. The process of research is as follow; 1) Estimate the remodeling cycle through survey targeting residents at high-rise apartment building. 2) Simulate conditions on the high-rise apartment housing. 3) Calculate quantity of energy consumption and $CO_2$ emission 4) Derive elements that are on high level of environmental load evaluation. The main results of this study is as follow; 1) The cycle of finishing such as wallpaper is shorter than the cycle of building equipment such as elements in a toilet. 2) According to result of calculating $CO_2$ emission, fabric wallpaper and mortar are main factors that impact on the environment. The results is important to show reference points on quantitative measuring evaluation for the environmental-friendly extent.